• 제목/요약/키워드: Wavelength shifting

검색결과 36건 처리시간 0.022초

Three-key Triple Data Encryption Algorithm of a Cryptosystem Based on Phase-shifting Interferometry

  • Seok Hee Jeon;Sang Keun Gil
    • Current Optics and Photonics
    • /
    • 제7권6호
    • /
    • pp.673-682
    • /
    • 2023
  • In this paper, a three-key triple data encryption algorithm (TDEA) of a digital cryptosystem based on phase-shifting interferometry is proposed. The encryption for plaintext and the decryption for the ciphertext of a complex digital hologram are performed by three independent keys called a wavelength key k1(λ), a reference distance key k2(dr) and a holographic encryption key k3(x, y), which are represented in the reference beam path of phase-shifting interferometry. The results of numerical simulations show that the minimum wavelength spacing between the neighboring independent wavelength keys is about δλ = 0.007 nm, and the minimum distance between the neighboring reference distance keys is about δdr = 50 nm. For the proposed three-key TDEA, choosing the deviation of the key k1(λ) as δλ = 0.4 nm and the deviation of the key k2(dr) as δdr = 500 nm allows the number of independent keys k1(λ) and k2(dr) to be calculated as N(k1) = 80 for a range of 1,530-1,562 nm and N(dr) = 20,000 for a range of 35-45 mm, respectively. The proposed method provides the feasibility of independent keys with many degrees of freedom, and then these flexible independent keys can provide the cryptosystem with very high security.

위상천이법을 이용한 삼차원 형상측정에서 위상오차 보정 (Phase error compensation for three-dimensional shape measurement based on a phase-shifting method)

  • 박윤창;안성준;강문호;권영철;안승준
    • 한국산학기술학회논문지
    • /
    • 제10권11호
    • /
    • pp.3023-3030
    • /
    • 2009
  • 고속 삼차원 형상측정에서는 충분한 위상이송 스텝 수를 적용할 시간을 확보할 수 없기 때문에, 스텝 수를 축소하게 되면서 위상측정에서의 잡음이 증가되게 된다. 본 논문에서는, 다파장 PMP법에 있어서 두 파장의 비례관계를 이용하여 측정된 위상에 포함되어 있는 위상오차를 예측하고, 이를 보정하는 방법을 제안하였으며, 제안된 보정방법의 효용성을 확인하기 위한 실험이 진행되었다. 위상천이법에서 통상적으로 사용되는 스텝 수에 비해 월등히 많은 스텝의 위상 이송으로 측정하였으며, 또한 동일한 대상물을 고속 삼차원측정에서 적용되는 3-3 step의 위상 이송으로 측정하여, 두 경우에서의 측정결과를 비교하여 고속측정에서의 측정잡음을 산출하였다. 그리고, 본 논문에서 제안하고 있는 보정 방법을 측정된 맥놀이 위상과 절대위상에 적용한 결과, 각각에 있어서 90%와 17.2%의 잡음감소가 이루어지는 것으로 확인되었다.

거친 표면 형상측정을 위한 큰 등가파장 회절격자 간섭계 (Diffraction grating interferometer of large equivalent wavelength for flatness testing of rough surfaces)

  • 황태준;김승우
    • 한국광학회지
    • /
    • 제15권1호
    • /
    • pp.56-62
    • /
    • 2004
  • 거친 표면의 형상을 측정하기 위해서 큰 등가파장 회절격자간섭계를 구성하였다. 제안된 시스템은 두 개의 투과회적격자를 사용해서 두 광을 측정물체에 각각 다른 각으로 경사지게 입사시켜서, 그 입사각에 따른 큰 등가파장의 간섭무늬를 얻는다. 이런 등가파장 간섭계는 기존의 광학 간섭계보다 넓은 영역에 걸쳐서 거친 표면을 빠른 시간에 측정할 수 있다. 제안된 시스템은 편광광속분할기와, 광속분할기, 프리즘을 사용해서, 불필요한 광을 제거하는 부분을 설계하여, 회절격자의 불필요한 회절광을 최소화하고, 회절격자의 형상으로 인한 시스템 오차를 줄였다. 뿐만 아니라, 큰 작동거리를 가지며 정렬이 쉽다. 측정정밀도를 향상시키기 위하여 위상편이법을 도입하였고, 등가파장보정법을 제안하였다. 실험을 통해서 측정시스템을 평가해보았다.

3-D Surface Profile Measurement Using An Acousto-optic Tunable Filter Based Spectral Phase Shifting Technique

  • Kim, Dae-Suk;Cho, Yong-Jai
    • Journal of the Optical Society of Korea
    • /
    • 제12권4호
    • /
    • pp.281-287
    • /
    • 2008
  • An acousto-optic tunable filter based 3-D micro surface profile measurement using an equally spaced 5 spectral phase shifting is described. The 5-bucket spectral phase shifting method is compared with a Fourier-transform method in the spectral domain. It can provide a fast measurement capability while maintaining high accuracy since it needs only 5 pieces of spectrally phase shifted imaging data and a simple calculation in comparison with the Fourier transform method that requires full wavelength scanning data and relatively complicated computation. The 3-D profile data of micro objects can be obtained in a few seconds with an accuracy of ${\sim}10nm$. The 3-D profile method also has an inherent benefit in terms of being speckle-free in measuring diffuse micro objects by employing an incoherent light source. Those simplicity and practical applicability is expected to have diverse applications in 3-D micro profilometry such as semiconductors and micro-biology.

고단차 불연속 형상의 3차원 측정을 위한 이중파장 위상천이 영사식 무아레 (Two-Wavelength Phase-Shifting Projection $Moir\acute{e}$ Topography for Measurement of Three-Dimensional Profiles with High Step Discontinuities)

  • 김승우;오정택;정문식;최이배
    • 대한기계학회논문집A
    • /
    • 제23권7호
    • /
    • pp.1129-1138
    • /
    • 1999
  • [$Moir\acute{e}$] technique is now being extensively investigated as a fast non-contact means of three-dimensional profile measurement especially for reverse engineering. One problem with $moir\acute{e}$ technique is so called $2\pi$-ambiguity problem that limits the maximum step height difference between two neighboring sampling points to be less than half the equivalent wavelength of $moir\acute{e}$ fringes. In this investigation, a new two-wavelength scheme of projection $moir\acute{e}$ topography is proposed and tested to cope with the $2\pi$-ambiguity problem. Experimental results are discussed to assess the new method in measuring large objects with high step discontinuities.

위상이동법과 시간평균법의 면내변위 측정 비교 (Comparison of In-Plane Measurement of Phase-Shifting with Time-Average Method)

  • 김경석;김동일;정현철;강기수;이찬우;양승필;장순석
    • 한국정밀공학회지
    • /
    • 제16권10호
    • /
    • pp.53-58
    • /
    • 1999
  • Even I the Electronic Speckle Pattern Interferometry(ESPI) method that measure the strain of object within wavelength of light is less visibility than Holographic Interferometry(HI) method, the merits of application, convenience and time-save have made the method practical in industry. However, the existing ESPI methods that are based on dual-exposure, real-time and time-average method have difficulties for accurate measurement, due to irregular intensity and shake of phase. Recently, in order to solve this problem, phase shifting method have been proposed. In this method, the path of reference light in interference is shifted to make improvement in distinction and precision. But this method includes too many noise, caused by the problem of relationship between object and phase. Therefore, a method to reduce noise muse be introduced. In this paper, least square fitting method is proposed. As results, the phase-map is influenced by precise phase shifting and current of notes and speckle pattern obtained by phase shifting method is improved on the existing method driven from time-average method.

  • PDF

비선형 광신호의 간섭현상 연구 (Study on the Interference Phenomena of Nonlinear Optical Signals)

  • 이은성;한재원;박승남;이충희
    • 한국광학회지
    • /
    • 제3권4호
    • /
    • pp.239-243
    • /
    • 1992
  • KDP 결정에서 2차 고조파가 발생될 때와 질소기체에서 CARS신호가 발생될 때 나타나는 간섭현상을 조사하였다. 비선형 신호들의 위상차이를 주기 위하여 광학유리를 이용하여 제작된 위상변이장치와 고압기체셀을 사용하였으며 각 매질에 대한 가간섭길이를 측정하였다. 특정한 스톡스광의 파장에서 CARS신호가 상쇄간섭을 일으키도록 위상변이장치의 두께를 조정한 후, 넓은 파장영역에서 상쇄간섭된 질소 CARS 스펙트럼을 얻었다. 위상변이장치의 두께를 바꾸면서 상쇄간섭정도의 변화를 관찰하였다.

  • PDF

Design and Simulation of Depth-Encoding PET Detector using Wavelength-Shifting (WLS) Fiber Readout

  • An, Su Jung;Kim, Hyun-il;Lee, Chae Young;Song, Han Kyeol;Park, Chan Woo;Chung, Young Hyun
    • IEIE Transactions on Smart Processing and Computing
    • /
    • 제4권5호
    • /
    • pp.305-310
    • /
    • 2015
  • We propose a new concept for a depth of interaction (DOI) positron emission tomography (PET) detector based on dual-ended-scintillator (DES) readout for small animal imaging. The detector consists of lutetium yttrium orthosilicate (LYSO) arrays coupled with orthogonal wavelength-shifting (WLS) fibre placed on the top and bottom of the arrays. On every other line, crystals that are 2 mm shorter are arranged to create grooves. WLS fibre is inserted into these grooves. This paper describes the design and performance evaluation of this PET detector using Monte Carlo simulations. To investigate sensitivity by crystal size, five types of PET detectors were simulated. Because the proposed detector is composed of crystals with three different lengths, degradation in sensitivity across the field of view was also explored by simulation. In addition, the effect of DOI resolution on image quality was demonstrated. The simulation results proved that the devised PET detector with excellent DOI resolution is helpful for reducing the channels of sensors/electronics and minimizing gamma ray attenuation and scattering while maintaining good detector performance.