• Title/Summary/Keyword: Waveform analysis

Search Result 748, Processing Time 0.026 seconds

Analysis of the Causes of Errors in Sound Wave Phase Meter (음파위상측정기의 오차 원인에 대한 분석)

  • Kim, So-Hee;Lee, Ki-Won
    • Journal of Sensor Science and Technology
    • /
    • v.28 no.5
    • /
    • pp.323-328
    • /
    • 2019
  • Recently, a sound wave phase meter (SWPM) that can directly measure the pressure waveform of sound waves in free space has been reported, and the development of educational experimental equipment using this meter is in progress. One of the main advantages of using this meter is that wavelengths can be obtained directly from the crests and troughs of the measured pressure waveforms in space without expensive equipment. However, there are times when the measurement wavelength does not exactly match the actual wavelength value, and the pressure waveform differs from the actual shape. This study was conducted to identify and analyze the causes of such errors occurring in SWPM. As a result, it was found that wavelength errors occur when the propagation direction of sound waves and the measurement direction of SWPM do not coincide. It has also been found that an error in the pressure waveform is generated when the induction and sound wave signal outputs from the SWPM interfere with each other to produce a composite signal. We have shown that we can develop educational experimental equipment by suggesting ways to reduce such errors.

A Study on the Blasting Dynamic Analysis using the Measurement Vibration Waveform (실측진동파형을 이용한 발파 동해석 기법에 관한 연구)

  • 최성웅;박의섭;선우춘;정소걸
    • Tunnel and Underground Space
    • /
    • v.14 no.2
    • /
    • pp.108-120
    • /
    • 2004
  • Dynamic analysis has been increased recently to analyze the effect of the blasting vibration on the rock mass as well as the surrounding structures. The major input parameter far the general dynamic analysis, however, is merely the blasting pressure which can be obtained from the blasting pressure-time history curves. But in case of the complicate geological condition it is not simple to apply the blasting pressure on the numerical analysis because e ground vibration characteristics should be obtained considering the complexity of ground condition. Therefore the authors tried to use the blasting vibration waveform as an input data This vinylation frequency could be obtained from the test blasting in the Pasir mine, Indonesia. Through the dynamic numerical analysis on the slopes in Pasir, the current situation of this slope could be simulated precisely.

Influence of Current Waveform on Anode Erosion in Wire Electric Discharge Machining (와이어 방전가공에서 전류파형이 양극침식에 미치는 영향)

  • Cho, Sung-San;Oh, Jin-Hyuk
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.18 no.7
    • /
    • pp.127-133
    • /
    • 2001
  • The effects of triangular and rectangular discharge current waveforms on anode erosion in wire electric discharge machining is investigated based on heat transfer analysis of half-space subject to time and space-dependent heat flux. The thermal load on the anode is simulated by a hear flux that is calculated from time-dependent discharge channel radius and energy. Evolution of the melting front during discharge, the molten volume at the experimental result for qualitative verification of the analysis. It is demonstrated that the triangular current waveform is more efficient in eroding the anode than the rectangular one.

  • PDF

A Study on the Characteristics of Cooperating Charge considering Dominant Frequency (주 주파수를 고려한 협동장약 특성에 관한 연구)

  • Kim Jong-In;Kang Choo-Won
    • Tunnel and Underground Space
    • /
    • v.15 no.4 s.57
    • /
    • pp.316-323
    • /
    • 2005
  • As a result of waveform analysis, the separation of waveform found that high frequency well accomplishes but low frequency doesn't accomplish that. The data which measured less than 60 Hz and more than 60 Hz was analysed to examine the relation between cooperating charge and frequency. The measured data of more than 70 Hz was also analysed to consider the characteristics of high frequency.

The Analysis of Arc Waveform for determing Surface Ageing of Polymeric Insulator for Out Door (옥외용 고분자 절연물의 표면 열화진단을 위한 아크파형 분석)

  • Moon, J.S.;Seo, K.S.;Kim, J.H.;Lee, J.H.;Song, W.C.;Park, Y.G.
    • Proceedings of the KIEE Conference
    • /
    • 1999.07e
    • /
    • pp.2405-2407
    • /
    • 1999
  • In recent, the application of polymeric insulators for outdoor is significantly increasing. These materials have shown good performance in service, but had disadvantages under long-term exposure to contamination and moisture, resulting in some problems. Thus, this study concentrated on the development of technique evaluating the insulating status. Experiment was referred to lEC publ. 587, with data aquisition system to monitor leakage current. The components of leakage current investigated were waveform and 3rd harmonic. FFT was conducted for the analysis of harmonic components. The distortion of waveform with application time of voltage was evident, and so the 3rd harmonic component.

  • PDF

Analysis and simulation of Cascaded H-bridge 7 level inverter for eliminating typical harmonic waveforms (특정 고조파 제거를 위한 Cascaded H-bridge 7레벨 인버터의 특성해석 및 시뮬레이션)

  • Jin, Sun-Ho;Oh, Jin-Suk;Jo, Kwan-Jun;Kwak, Jun-Ho;Lim, Myoung-Kyu;Kim, Jang-Mok
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2005.06a
    • /
    • pp.1022-1028
    • /
    • 2005
  • This paper is presented the analysis results and simulation results of cascaded H-bridge 7 level inverter with various modulation index. Stepped waveform having number of switching was used to eliminate harmonic components. Switching angles according to modulation index are calculated numerically. Therefore, 3 times of switching with 7 level topology and QWS(Quarter Wave Symmetry) could eliminate 5th and 7th harmonics. The harmonic characteristics are compared to those of space vector modulation method which known as common modulation method in industrial field. Stepped waveform method showed higher ability to reduce, especially lower order of harmonics.

  • PDF

Design and Implementation of a Multi Level Three-Phase Inverter with Less Switches and Low Output Voltage Distortion

  • Ahmed, Mahrous E.;Mekhilef, Saad
    • Journal of Power Electronics
    • /
    • v.9 no.4
    • /
    • pp.593-603
    • /
    • 2009
  • This paper proposes and describes the design and operational principles of a three-phase three-level nine switch voltage source inverter. The proposed topology consists of three bi-directional switches inserted between the source and the full-bridge power switches of the classical three-phase inverter. As a result, a three-level output voltage waveform and a significant suppression of load harmonics contents are obtained at the inverter output. The harmonics content of the proposed multilevel inverter can be reduced by half compared with two-level inverters. A Fourier analysis of the output waveform is performed and the design is optimized to obtain the minimum total harmonic distortion. The full-bridge power switches of the classical three-phase inverter operate at the line frequency of 50Hz, while the auxiliary circuit switches operate at twice the line frequency. To validate the proposed topology, both simulation and analysis have been performed. In addition, a prototype has been designed, implemented and tested. Selected simulation and experimental results have been provided.

Pulse Waveform Simulation of Partial Discharges for HV XLPE Cable Joints (초고압 XLPE 케이블 접속함의 부분방전 펄스파형 시뮬레이션)

  • Kim, Jeong-Tae
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.67 no.1
    • /
    • pp.75-81
    • /
    • 2018
  • In this study, the simulation of partial discharge pulse waveform have been performed for the typical joints such as EBA and PMJ in the HV underground transmission XLPE cable system in order to improve the understanding of partial discharge pulse waveform and the on-site measurement accuracy of partial discharges. FDTD simulation technique was adopted for the simulation and has been shown to be suitable for partial discharge simulation of power cables in terms of pulse propagation characteristics and waveform formation. The simulation results for the EBA showed that the second not-so-large opposite polarity peak appeared after the first negative polarity peak and the measurement sensitivity was the highest near the bottom of the EBA copper box. In the analysis results for PMJ, the magnitude of the second opposite polarity peak was large enough to compare with the first peak, and the measurement sensitivity at the end of the PMJ copper box was the highest. These simulation results show considerable similarity with the on-site measurement, and it would be very useful for the partial discharge measurement of HV XLPE cable systems.

Analysis of Volatage and Current Waveform Distortion Characteristics at Office Buildings (사무용 빌딩에서의 전압 및 전류파형 왜곡특성 분석)

  • Yoo, Jae-Geun;Lee, Sang-lck;Jeon, Jeong-Chay;Jeong, Jong-Wook;Lim, Young-Bae
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.19 no.1
    • /
    • pp.155-161
    • /
    • 2005
  • Nonlinear electronic loads used at office buildings distort the voltage and current waveform that cause the overheating of transformer losses, ELB(Electrical Leakage Breaker) tripping, and so on. This paper analyzed waveform distortion characteristics at several once buildings by comparing with magnitude of voltage and current harmonics, crest factor of voltage and current, phase voltage and current unbalance. As a consequence, severe current waveform distortion in phase and neutral line by harmonics and high current unbalance rates by unbalanced using of single loads among the three phases are investigated. The results of the study can be used in making decisions regarding reasonable and economical operating of loads at office buildings.

The Properties of Waveform and Plug Formed by Poor Contact of Power Cord Sets (전원코드의 접촉 불량에 의해 형성된 파형 및 플러그의 특성)

  • Choi Chung-Seog;Kim Hyang-Kon;Kim Dong-Ook;Kim Young-Seok
    • Journal of the Korean Society of Safety
    • /
    • v.20 no.1 s.69
    • /
    • pp.87-93
    • /
    • 2005
  • In this paper, we analyzed ignition characteristics of combustible material and the waveform of power dissipation, voltage and current by poor contact. And the surface structure of plug by poor contact was analyzed. In the results of experiment, the heat generated by poor contact and ignited the combustible material on power cord sets. The insulation material was molten and carbonized by the heat conduction though plug pit and voids were formed inside of insulation material. The waveform of voltage and power dissipation distorted because of a growth of oxidation by poor contact. In particular, in case that load was big load, the waveform of voltage and power dissipation severely distorted as with the passage of time. The surface of plug pin was changed from erosion mark to welding mark according to big load. The results will be applied to the cause analysis of electrical disaster.