• Title/Summary/Keyword: Waveform Interpolation

Search Result 20, Processing Time 0.023 seconds

Implementation of Wideband Waveform Interpolation Coder for TTS DB Compression (TTS DB 압축을 위한 광대역 파형보간 부호기 구현)

  • Yang, Hee-Sik;Hahn, Min-Soo
    • MALSORI
    • /
    • v.55
    • /
    • pp.143-158
    • /
    • 2005
  • The adequate compression algorithm is essential to achieve high quality embedded TTS system. in this paper, we Propose waveform interpolation coder for TTS corpus compression after many speech coder investigation. Unlike speech coders in communication system, compression rate and anality are more important factors in TTS DB compression than other performance criteria. Thus we select waveform interpolation algorithm because it provides good speech quality under high compression rate at the cost of complexity. The implemented coder has bit rate 6kbps with quality degradation 0.47. The performance indicates that the waveform interpolation is adequate for TTS DB compression with some further study.

  • PDF

Time-Domain Quantization and Interpolation of Pitch Cycle Waveform

  • Kim, Moo-Young
    • The Journal of the Acoustical Society of Korea
    • /
    • v.27 no.1E
    • /
    • pp.11-16
    • /
    • 2008
  • In this paper, a pitch cycle waveform (PCW) is extracted, quantized, and interpolated in a time domain to synthesize high-quality speech at low bit rates. The pre-alignment technique is proposed for the accurate and efficient PCW extraction, which predicts the current PCW position from the previous PCW position assuming that pitch periods evolve slowly. Since the pitch periods are different frame by frame, the original PCW is converted into the fixed-dimension PCW using the dimension-conversion method, and subsequently quantized by code-excited linear predictive (CELP) coding. The excitation signal for the linear predictive coding (LPC) synthesis filter is generated using the time-domain interpolation and interlink of the quantized PCW's. The coder operates at 4.2 kbit/s and 3.2 kbit/s depending on the pitch period. Informal listening test demonstrates the effectiveness of the proposed coding scheme.

Wavelet-based Pitch Detector for 2.4 kbps Harmonic-CELP Coder (2.4 kbps 하모닉-CELP 코더를 위한 웨이블렛 피치 검출기)

  • 방상운;이인성;권오주
    • The Journal of the Acoustical Society of Korea
    • /
    • v.22 no.8
    • /
    • pp.717-726
    • /
    • 2003
  • This paper presents the methods that design the Wavelet-based pitch detector for 2,4 kbps Harmonic-CELP Coder, and that achieve the effective waveform interpolation by decision window shape of the transition region, Waveform interpolation coder operates by encoding one pitch-period-sized segment, a prototype segment, of speech for each frame, generate the smooth waveform interpolation between the prototype segments for voiced frame, But, harmonic synthesis of the prototype waveforms between previous frame and current frame occur not only waveform errors but also discontinuity at frame boundary on that case of pitch halving or doubling, In addtion, in transition region since waveform interpolation coder synthesizes the excitation waveform by using overlap-add with triangularity window, therefore, Harmonic-CELP fail to model the instantaneous increasing speech and synthesis waveform linearly increases, First of all, in order to detect the precise pitch period, we use the hybrid 1st pitch detector, and increse the precision by using 2nd ACF-pitch detector, Next, in order to modify excitation window, we detect the onset, offset of frame by GCI, As the result, pitch doubling is removed and pitch error rate is decreased 5.4% in comparison with ACF, and is decreased 2,66% in comparison with wavelet detector, MOS test improve 0.13 at transition region.

Fully Analog ECG Baseline Wander Tracking and Removal Circuitry using HPF Based R-peak Detection and Quadratic Interpolation

  • Nazari, Masoud;Rajeoni, Alireza Bagheri;Lee, Kye-Shin
    • Journal of Multimedia Information System
    • /
    • v.7 no.3
    • /
    • pp.231-238
    • /
    • 2020
  • This work presents a fully analog baseline wander tracking and removal circuitry using high-pass filter (HPF) based R-peak detection and quadratic interpolation that does not require digital post processing, thus suitable for compact and low power long-term ECG monitoring devices. The proposed method can effectively track and remove baseline wander in ECG waveforms corrupted by various motion artifacts, whereas minimizing the loss of essential features including the QRS-Complex. The key component for tracking the baseline wander is down sampling the moving average of the corrupted ECG waveform followed by quadratic interpolation, where the R-peak samples that distort the baseline tracking are excluded from the moving average by using a HPF based approach. The proposed circuit is designed using CMOS 0.18-㎛ technology (1.8V supply) with power consumption of 19.1 ㎼ and estimated area of 15.5 ㎟ using a 4th order HPF and quadratic interpolation. Results show SNR improvement of 10 dB after removing the baseline wander from the corrupted ECG waveform.

A New Variable Bit Rate Scheme for Waveform Interpolative Coders (파형보간 코더에서 파라미터간 거리차를 이용한 가변비트율 기법)

  • Yang, Hee-Sik;Jeong, Sang-Bae;Hahn, Min-Soo
    • MALSORI
    • /
    • no.65
    • /
    • pp.81-91
    • /
    • 2008
  • In this paper, we propose a new variable bit-rate speech coder based on the waveform interpolation concept. After the coder extracted all parameters, the amounts of the distortions between the current and the predicted parameters which are estimated by extrapolation using past two parameters are measured for all parameters. A parameter would not be transmitted unless the distortion exceeds the preset threshold. At the decoder side, the non-transmitted parameter is reconstructed by extrapolation with past two parameters used to synthesize signals. In this way, we can reduce 26% of the total bit rate while retaining the speech quality degradation below 0.1 PESQ score.

  • PDF

Reconstruction of the Undersampled Photoplethysmogram with Various Interpolation Methods (보간 방법에 따른 언더샘플링된 광용적맥파 복원 가능성 평가)

  • Shin, Hangsik;Kim, Hoon
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.8
    • /
    • pp.1418-1423
    • /
    • 2016
  • The purpose of this research is to investigate the effect of sampling frequency on the photoplethysmography (PPG) and to evaluate the performance of interpolation methods for under-sampled PPG. We generated down-sampled PPG using 10 kHz-sampled PPG then evaluated waveshape changes with correlation coefficient. Correlation coefficient was significantly decreased at 50 Hz or below sampling frequency. We interpolated the down-sampled PPG using four interpolation method-linear, nearest, cubic spline and piecewise cubic Hermitt interpolation polynomial - then evaluated interpolation performance. As a result, it was shown that PPG waveform that was sampled over 20 Hz could be reconstructed by interpolation. Among interpolation methods, cubic spline interpolation showed the highest performance. However, every interpolation method has no or less effect on 5 Hz sampled PPG.

Enhanced source controlled variable bit-rate scheme in a waveform interpolation coder (Source controlled variable bit-rate scheme을 이용한 파형 보간 부호화기의 음질 개선 기법)

  • Cho, Keun-Seok;Yang, Hee-Sik;Jeong, Sang-Bae;Hahn, Min-Soo
    • Proceedings of the KSPS conference
    • /
    • 2007.05a
    • /
    • pp.315-318
    • /
    • 2007
  • This paper proposes the methods to enhance the speech quality of source controlled variable bit-rate coder based on the waveform interpolation. The methods are to estimate and generate the parameters that are not transmitted from encoder to decoder by the repetition and extrapolation schemes. For the performance evaluation, the PESQ(Perceptual Evaluation of Speech Quality) scores are measured. The experimental results shows that our proposed method outperforms the conventional source controlled variable bit-rate coder. Especially, the performance of the extrapolation method is better than that of the repetition method.

  • PDF

ISAR Imaging Using Rear View Radars of an Automobile (후방 감시 차량용 레이다를 이용한 ISAR 영상 형성)

  • Kang, Byung-Soo;Lee, Hyun-Seok;Lee, Seung-Jae;Kang, Min-Suk;Kim, Kyung-Tae
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.25 no.2
    • /
    • pp.245-250
    • /
    • 2014
  • This paper introduces the inverse synthetic aperture radar(ISAR) imaging technique for rear view target of an automobile, which uses both linear frequency modulation-frequency shift keying(LFM-FSK) waveform and monopulse tracking. LFM-FSK waveform consists of two sequential stepped frequency waveforms with some frequency offset, and thus, can be used to generate ISAR images of rear view target of an automobile. However, ISAR images can often be blurred due to non-uniform change rate of relative aspect angle between radar and target. In order to address this problem, one-dimensional(1-D) Lagrange interpolation technique in conjunction with angle information obtained from the monopulse tracking is applied to generate uniform data across the radar's aspect angle. Simulation results show that the proposed method can provide focused ISAR images.

ECG Data Compression Using Adaptive Fractal Interpolation (적응 프랙탈 보간을 이용한 심전도 데이터 압축)

  • 전영일;윤영로
    • Journal of Biomedical Engineering Research
    • /
    • v.17 no.1
    • /
    • pp.121-128
    • /
    • 1996
  • This paper presents the ECG data compression method referred the adaptive fractal interpolation algorithm. In the previous piecewise fractal interpolation(PFI) algorithm, the size of range is fixed So, the reconstruction error of the PFI algorithm is nonuniformly distributed in the part of the original ECG signal. In order to improve this problem, the adaptive fractal interpolation(AEI) algorithm uses the variable range. If the predetermined tolerance was not satisfied, the range would be subdivided into two equal size blocks. large ranges are used for encoding the smooth waveform to yield high compression efficiency, and the smaller ranges are U for encoding rapidly varying parts of the signal to preserve the signal quality. The suggested algorithm was evaluated using MIT/BIH arrhythmia database. The AEI algorithm was found to yield a relatively low reconstruction error for a given compression ratio than the PFI algorithm. In applications where a PRD of about 7.13% was acceptable, the ASI algorithm yielded compression ratio as high as 10.51, without any entropy coding of the parameters of the fractal code.

  • PDF

Finite Element Analysis of Magnetostriction Force in Transformer Based on an Anisotropic Magnetostriction Model (이방성 자왜 모델을 기반으로 한 변압기 자왜력의 유한요소 해석)

  • Zhu, Lixun;Jeong, Gilgyun;Koh, Chang-Seop
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.772-773
    • /
    • 2015
  • This paper presents a dynamic model of 2-D magnetostriction in electrical steel sheet (ESS) under rotating flux magnetization conditions and its implementation in finite element method (FEM). For an arbitrary waveform of magnetic flux density (B), the corresponding magnetostriction waveform can be predicted by the model. In order to apply the model to FEM easily, the model is based on trilinear interpolation method. As an example, the model is applied to a three-phase transformer constructed by highly grain-oriented electrical steel sheets and the numerical results by the magnetostriction model are discussed.

  • PDF