Cyclic fatigue life of Tango-Endo, WaveOne GOLD, and Reciproc NiTi instruments

  • Yilmaz, Koray;Ozyurek, Taha
    • Restorative Dentistry and Endodontics
    • /
    • v.42 no.2
    • /
    • pp.134-139
    • /
    • 2017
  • Objectives: To compare the fatigue life of Tango-Endo, WaveOne GOLD, and Reciproc NiTi instruments under static model via artificial canals with different angles of curvature. Materials and Methods: Reciproc R25, WaveOne GOLD Primary, and Tango-Endo instruments were included in this study (n = 20). All the instruments were rotated in artificial canals which were made of stainless steel with an inner diameter of 1.5 mm, $45^{\circ}$, $60^{\circ}$, and $90^{\circ}$ angles of curvatures and a radius of curvature of 5 mm until fracture occurred, and the time to fracture was recorded in seconds using a digital chronometer. The data were analyzed using Kruskal-Wallis and post-hoc Dunn tests were used for the statistical analysis of data in SPSS 21.0 software. Results: Tango-Endo files were found to have significantly higher values than WaveOne GOLD and Reciproc files in terms of fatigue life (p < 0.05). However, there was no statistically significant difference between fatigue life of Reciproc and WaveOne GOLD files (p > 0.05). It was determined that increasing the angle of curvature of the stainless canals caused significant decreases in fatigue life of all of three files (p < 0.05). Conclusions: Within the limitations of the present study, the cyclic fatigue life of Tango-Endo in canals having different angles of curvature was statistically higher than Reciproc and WaveOne GOLD.

Cyclic fatigue resistance of the WaveOne Gold Glider, ProGlider, and the One G glide path instruments in double-curvature canals

  • Kirici, Damla;Kustarci, Alper
    • Restorative Dentistry and Endodontics
    • /
    • v.44 no.4
    • /
    • pp.36.1-36.6
    • /
    • 2019
  • Objectives: The aim of this study was to compare the cyclic fatigue resistance of the WaveOne Gold Glider, ProGlider and One G glide path instruments in artificial doublecurvature canals. Materials and Methods: This study included 15 WaveOne Gold Glider (size 15/0.08), 15 ProGlider (size 16/0.08), and 15 One G (size 16/0.06) nickel titanium files. The files were used in accordance with the manufacturer's instructions until they were broken in artificial double-curvature canals made of stainless steel. The time to fracture was recorded via a digital stopwatch and the number of rotations until fracture was also calculated. The data were statistically analyzed via the Kruskal-Wallis test. Results: The highest average number of rotations until fracture of the files was found for the WaveOne Gold Glider, followed by ProGlider and One G in order. Statistically significant differences were present between all groups of files (p < 0.05). Conclusions: In our study, the resistance of the WaveOne Gold Glider nickel-titanium (Ni-Ti) file to cyclic fatigue in S-shaped curved canals was found to be higher than that of the ProGlider and One G Ni-Ti files.

Comparison of the shaping ability of novel thermally treated reciprocating instruments

  • Keskin, Cangul;Demiral, Murat;Sariyilmaz, Evren
    • Restorative Dentistry and Endodontics
    • /
    • v.43 no.2
    • /
    • pp.15.1-15.7
    • /
    • 2018
  • Objectives: The present study aimed to evaluate the shaping ability of 2 thermally treated nickel-titanium reciprocating systems in simulated curved canals. Materials and Methods: Forty simulated canals were prepared to apical size 25 using Reciproc Blue R25 (VDW) and WaveOne Gold Primary (Dentsply Sirona) instruments. Standard pre- and post-preparation images were taken and superimposed. The removal of resin material was measured at 5 standard points: the canal orifice, halfway between the canal orifice and the beginning of the curve, the beginning of the curve, the apex of the curve, and the end-point of the simulated canal. The data were analysed using the independent sample t-test with a 5% significance threshold. Results: The canals in which Reciproc Blue R25 was used showed a significantly greater widening than those in which WaveOne Gold was used at 4 of the 5 measurement points (p < 0.05). The Reciproc Blue R25 instrument removed significantly more resin from the inner aspect of the curve at 2 of the 5 points and similar amounts at the remaining 3 points. At the 2 apical points, there was no significant difference between the Reciproc Blue R25 and WaveOne Gold Primary instruments. Conclusion: Both instruments respected the original canal anatomy; however, WaveOne Gold resulted in a more conservative shape with less transportation.

The effect of root canal preparation on the surface roughness of WaveOne and WaveOne Gold files: atomic force microscopy study

  • Ozyurek, Taha;Yilmaz, Koray;Uslu, Gulsah;Plotino, Gianluca
    • Restorative Dentistry and Endodontics
    • /
    • v.43 no.1
    • /
    • pp.10.1-10.8
    • /
    • 2018
  • Objectives: To examine the surface topography of intact WaveOne (WO; Dentsply Sirona Endodontics) and WaveOne Gold (WOG; Dentsply Sirona Endodontics) nickel-titanium rotary files and to evaluate the presence of alterations to the surface topography after root canal preparations of severely curved root canals in molar teeth. Materials and Methods: Forty-eight severely curved canals of extracted molar teeth were divided into 2 groups (n = 24/each group). In group 1, the canals were prepared using WO and in group 2, the canals were prepared using WOG files. After the preparation of 3 root canals, instruments were subjected to atomic force microscopy analysis. Average roughness and root mean square values were chosen to investigate the surface features of endodontic files. The data was analyzed using one-way analysis of variance and post hoc Tamhane's tests at 5% significant level. Results: The surface roughness values of WO and WOG files significantly changed after use in root canals (p < 0.05). The used WOG files exhibited higher surface roughness change when compared with the used WO files (p < 0.05). Conclusions: Using WO and WOG Primary files in 3 root canals affected the surface topography of the files. After being used in root canals, the WOG files showed a higher level of surface porosity value than the WO files.

Effect of number of uses and sterilization on the instrumented area and resistance of reciprocating instruments

  • Victor de Ornelas Peraca ;Samantha Rodrigues Xavier ;Fabio de Almeida Gomes ;Luciane Geanini Pena dos Santos;Erick Miranda Souza ;Fernanda Geraldo Pappen
    • Restorative Dentistry and Endodontics
    • /
    • v.46 no.2
    • /
    • pp.28.1-28.10
    • /
    • 2021
  • Objectives: This study evaluated the effect of repeated uses and autoclaving in the instrumented area, fracture resistance, and time of instrumentation of thermally treated nickel-titanium reciprocating systems. Materials and Methods: Two hundred simulated canals were instrumented using Reciproc Blue and WaveOne Gold. Each file was used up to 10 times or until fracture. The instrumented area was measured in pre- and post-operative images, using ImageJ software. Kaplan-Meier survival analysis evaluated the number of uses of instruments before fracture. Instrumented area and time of instrumentation were analyzed by Mann-Whitney U test and Kruskal-Wallis. Correlations among the number of uses and instrumented area were measured. The level of statistical significance was set at p < 0.05. Results: Reciproc Blue presented a higher estimated number of uses in comparison with WaveOne Gold (p = 0.026), but autoclaving did not affect the resistance to fracture of instruments (p > 0.05). The instrumented area was different among the evaluated groups (p = 0.039), and the instrumented area along the uses of both tested instruments was reduced. With the time of instrumentation, there was also a significant difference among the evaluated groups; the groups without sterilization cycles were faster, in comparison to those submitted to autoclaving (p = 0.010). Conclusions: Reciproc Blue was more resistant than WaveOne Gold, suffering later fracture. Additionally, the sterilization cycles did not influence the estimated number of uses of thermally treated reciprocating instruments, but the instrumented area of root canals was reduced along with the repeated uses of both instruments.

Effects of Dynamic Soil Behaviour on Wave-Induced Seabed Response

  • Cha, D.H.;Jeng, D.S.;Rahman, M.S.;Sekiguchi, H.;Zen, K.;Yamazaki, H.
    • International Journal of Ocean Engineering and Technology Speciallssue:Selected Papers
    • /
    • v.5 no.1
    • /
    • pp.1-13
    • /
    • 2002
  • In this paper, an analytical solution for the wave-induced seabed response in a porous seabed is derived. Unlike previous investigations with quasi-static soil behaviour, dynamic soil behaviour is considered in the new solution. The basic one-dimensional framework proposed by Zienkiewicz et al (1980) is extended to two-dimensional cases. Based on the analytical solution derived, the effects of dynamic soil behaviour on the wave-induced seabed response are examined. The boundary of quasi-static soil behaviour and dynamic soil behaviour is clarified, and formulated for engineering practice.

  • PDF

Comparison of vibration characteristics of file systems for root canal shaping according to file length

  • Seong-Jun Park;Se-Hee Park ;Kyung-Mo Cho ;Hyo-Jin Ji ;Eun-Hye Lee ;Jin-Woo Kim
    • Restorative Dentistry and Endodontics
    • /
    • v.45 no.4
    • /
    • pp.51.1-51.10
    • /
    • 2020
  • Objectives: No studies have yet assessed vibration characteristics according to endodontic file length. Accordingly, the objective of the present study was to examine the vibration characteristics according to nickel-titanium file length and to compare these characteristics between different file systems. Materials and Methods: A total of 45 root canal models were divided into 3 experimental groups (n = 15 each) based on the file system used (ProTaper Gold [PTG], ProTaper Next, or WaveOne Gold [WOG]). Each experimental group was further divided into 3 subgroups according to file length (21, 25, or 31 mm). An electric motor (X-SMART PLUS) was used in the experiment. For each file system, vibrations generated when using a size 25 file were measured and used to calculate the average vibration acceleration. The differences in vibrations were analyzed using 1-way analysis of variance and the Scheffé post hoc test with a confidence interval of 95%. Results: In the PTG file system, significantly lower vibration acceleration was observed when using a 21-mm file than when using a 31-mm file. In the WOG file system, significantly stronger vibration acceleration was observed when using a 31-mm file than when using 21- or 25-mm files. Regardless of the file length, the WOG group exhibited significantly stronger vibration acceleration than the other 2 experimental groups. Conclusions: In clinical practice, choosing a file with the shortest length possible could help reduce vibrations. Additionally, consideration should be given to vibrations that could be generated when using WOG files with reciprocating motion.

The Effect of Non-ivasive Baihui($GV_{20}$) Point Stimulus by 'Dong Chu Gold Chim' on Electroencephalogram (동추금침(東樞金鍼)에 의한 비침습적 백회혈(百會穴) 자극이 뇌파에 미치는 영향)

  • Ma, Jeung-Hun;Han, Chang-Hyun;Park, Soo-Jin;Choi, Woo-Suk;Lee, Sang-Nam;Park, Ji-Ha
    • Journal of Acupuncture Research
    • /
    • v.27 no.1
    • /
    • pp.87-100
    • /
    • 2010
  • Background : Recently a discussion about Qi including a study about the effect or the theory of acupuncture is getting prevailing in various angles. In most of studies about acupuncture stimulus, 'Filiform acupuncture'(毫鍼) is used. A study about Nine kinds of acupuncture(九鍼), except 'Filiform acupuncture'(毫鍼) has not been reported yet, and there is no study about using a special acupuncture made for controling Qi either. Objectives : 'Dong Chu Gold Chim(DCG-chim, 東樞金鍼)' can be used for patients who are scared of a pain because it is a medical Qi-gong tool and non-invasive stimulus one. To assess a effect of Qi-gong operation using DCG-chim objectively Methods : The present study was performed to elucidate the effects of DCG-chim stimulation of an acupuncture point Baihui($GV_{20}$) on the Electroencephalogram(EEG). Twenty healthy subject were treated with DCG-chim one time accompanied by the light and vertical pressure and EEG were measured during five minutes for three times (before, during and after treatment). The EEG results of DCG-chim treatment were compared with those of 'Filiform acupuncture(毫鍼)'. Results : EEG power spectra changed significantly after both kind of acupuncture stimulation. Significant increase of $\alpha$ wave and decrease of $\beta$ wave were observed but interestingly, Mid-$\beta$ and SMR of $\beta$ wave which mean the state of concentration were increased with statistically significant. According to these results, DCG-chim stimulation of Baihui($GV_{20}$) seems to lead to relaxation with antianxietic effect and improvement of concentration at the same time. Conclusions : It would be expected that the doctor can apply DCG-chim for treating anxiety, tension, symptom caused by stress and also can use it clinically for patients who have needlphopia or children as a non-invasive procedure. It is suggested that additional studies about the effect of DCG-chim on other acupuncture points and comparison study about the effect of DCG-chim with those of the finger-pressure treatment using other tool should be done in the future.

Assessment of postoperative pain after single-visit root canal treatment using rotary and reciprocating file systems: an in vivo study

  • Shaik, Reshma Parveen;Chukka, Ram Sunil;Bandlapally, Anila;Vemuri, Sayesh;Bolla, Nagesh;Basam, Ram Chowdary;Tammineedi, Sravanthi
    • Journal of Dental Anesthesia and Pain Medicine
    • /
    • v.22 no.4
    • /
    • pp.267-275
    • /
    • 2022
  • Background: Various instrument kinematics used in single-visit endodontics influence the occurrence of pain after endodontic therapy. This study aimed to evaluate the occurrence of pain after mechanical instrumentation with Hyflex EDM (HEDM) and WaveOne Gold (WOG) during single-visit endodontic therapy. Methods: Sixty patients diagnosed with asymptomatic irreversible pulpitis and normal apical tissues in mandibular premolar teeth were included in the study for single-visit root canal therapy. The patients were divided into two groups (n = 30) according to the rotary instrument used during root canal preparation (group A [HEDM] and group B [WOG]). Pain was evaluated after endodontic therapy at 8, 24, and 48 h intervals using the visual analog scale (VAS). Data obtained were analyzed using the chi-square test, independent t-test, MannWhitney U test, and Wilcoxon matched-pairs test. Results: Statistically significant differences were observed between the two groups (P < 0.001) at 8, 24, and 48 h, with WOG exhibiting less pain than HEDM files. Conclusion: Postoperative pain was lower in the WOG file system than in the HEDM file system after single-visit root canal therapy at 8, 24, and 48 h.

Comparative analysis of torsional and cyclic fatigue resistance of ProGlider, WaveOne Gold Glider, and TruNatomy Glider in simulated curved canal

  • Pedro de Souza Dias;Augusto Shoji Kato;Carlos Eduardo da Silveira Bueno;Rodrigo Ricci Vivan;Marco Antonio Hungaro Duarte ;Pedro Henrique Souza Calefi ;Rina Andrea Pelegrine
    • Restorative Dentistry and Endodontics
    • /
    • v.48 no.1
    • /
    • pp.4.1-4.10
    • /
    • 2023
  • Objectives: This study aimed to compare the torsional and cyclic fatigue resistance of ProGlider (PG), WaveOne Gold Glider (WGG), and TruNatomy Glider (TNG). Materials and Methods: A total of 15 instruments of each glide path system (n = 15) were used for each test. A custom-made device simulating an angle of 90° and a radius of 5 millimeters was used to assess cyclic fatigue resistance, with calculation of number of cycles to failure. Torsional fatigue resistance was assessed by maximum torque and angle of rotation. Fractured instruments were examined by scanning electron microscopy (SEM). Data were analyzed with Shapiro-Wilk and Kruskal-Wallis tests, and the significance level was set at 5%. Results: The WGG group showed greater cyclic fatigue resistance than the PG and TNG groups (p < 0.05). In the torsional fatigue test, the TNG group showed a higher angle of rotation, followed by the PG and WGG groups (p < 0.05). The TNG group was superior to the PG group in torsional resistance (p < 0.05). SEM analysis revealed ductile morphology, typical of the 2 fracture modes: cyclic fatigue and torsional fatigue. Conclusions: Reciprocating WGG instruments showed greater cyclic fatigue resistance, while TNG instruments were better in torsional fatigue resistance. The significance of these findings lies in the identification of the instruments' clinical applicability to guide the choice of the most appropriate instrument and enable the clinician to provide a more predictable glide path preparation.