• 제목/요약/키워드: Wave heat exchanger

검색결과 37건 처리시간 0.041초

맥동관 냉동기 열교환기에 관한 실험적 연구 (An Experimental Study on the Heat Exchangers in the Pulse Tube Refrigerator)

  • 남관우;정상권;정은수
    • 설비공학논문집
    • /
    • 제12권3호
    • /
    • pp.284-291
    • /
    • 2000
  • A basic pulse tube refrigerator has been constructed with extensive instrumentation to study the characteristics of the heat exchanger experimentally under the oscillating pressure and the oscillating flow. This paper describes the sequential experiments with the basic pulse tube refrigerator. The experiments were performed for various cycle frequencies under the square pressure wave forms. First, the heat flux was measured through the cycle at the both cold and warm end heat exchangers without the regenerator. In order to enhance the thermal communication capability of the heat exchanger with the gas at low operating frequencies, a unique design of the triangular shape radial fin concept was applied to the heat exchangers. For the fin heat exchanger, the measured heat flux and the calculated heat flux from the two well-known oscillating heat transfer correlations were compared and discussed. Second, the regenerator was added to the pulse tube to make a basic pulse tube refrigerator configuration. The experiment showed the great impact of the regenerator on the temperature and the heat flux profiles. At the warm-end, the cyclic averaged heat flux had its maximum value at the specific operating frequency. The paper presents the explanation of the surface heat pumping effect as well as the experimental data.

  • PDF

발전소 열교환기에서의 유동유발 진동저감 (Reduction of Flow Induced Vibration in the Heat Exchanger of Thermal Power Plant)

  • 장한기;김승한
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2000년도 춘계학술대회논문집
    • /
    • pp.633-638
    • /
    • 2000
  • This paper reports an example of flow-induced vibration in a very large plant and the whole procedure of reducing the vibration. During the operation of flue gas desurfurization unit of the thermal power plant, serious vibration occurred at all around the unit. The worst vibration was recorded on the heat exchanger surface, which weighed 180 tones, as 17.8 m/$s^2$ in vibration amplitude at 34Hz. To identify the vibration, frequency analysis on the response vibration, the expected excitation force and the system resonance was executed. This investigation revealed that the cause of the vibration was vortex shedding from the circular pipes in the heat exchanger. Vortices from the pipes excited acoustic resonance in the heat exchanger room, which, in turn, made the structure vibrate. Through inserting the baffles between the pipes, which had an effect of cutting the acoustic wave at resonance frequency, the vibration was eliminated dramatically.

  • PDF

순 티타늄 박판의 파이버 레이저 용접시 결함 억제를 위한 연속의 출력 파형제어 특성(II) - 중첩부 길이변화에 따른 영향 - (The Characteristics of Continuous Waveshape Control for the Suppression of Defects in the Fiber Laser Welding of Pure Titanium Sheet (II) - The Effect According to Control of Overlap Weld Length -)

  • 김종도;김지성
    • Journal of Welding and Joining
    • /
    • 제34권6호
    • /
    • pp.69-74
    • /
    • 2016
  • Because the pure titanium has superior corrosion resistance and formability compared with different material, it is widely used as material of welded heat exchanger. When the welding of heat exchanger is carried out, certain area in which welding start and end are overlapped occurs. The humping of back bead is formed in the overlap area due to partial penetration. Thus in this study, the experiments were carried out by changing the length and wave shape of overlap area, and then the weldabiliay was evaluated through the observation of microstructure, the measurement of hardness and tensile-shear strength test in the overlap area. When overlap length was 9.8mm, humping bead was suppressed. The microstructure of overlap area coarsened and its hardness increased due to remelting. As a result of tensile-shear strength test in the overlap area according to applying the wave shape control, it was confirmed that the overlap area applied wave shape control had more excellent yield strength and ductility.

성능 예측 상관식에 따른 쉐브론 형태 판형 열교환기 성능 특성 비교 (Comparison of Performance Characteristics in the Chevron Type Plate Heat Exchanger with Performance Correlation)

  • 배경진;안성국;조현욱;남상철;조홍현
    • 설비공학논문집
    • /
    • 제23권8호
    • /
    • pp.535-542
    • /
    • 2011
  • The performance of a plate heat exchanger for using liquid solution in the absorption chiller-heater was analyzed. The model was developed by using the various performance prediction correlations. The performance characteristics of the plate heat exchanger with the mass flow rate ratio was verified by using experimental data. To investigate performance of plate heat exchanger with geometry variables, the chevron angle, corrugated wave length, and corrugation depth were changed. As a result, the capacity of Kim and Martin correlation models was similar with the experimental data, and the capacity difference was less than 2%. Besides, the pressure drop of Marin correlation model showed a similar variation with experimental data, and the difference of pressure drop was less than 1.5 kPa.

사인 웨이브 핀과 타원관으로 구성된 핀-관 열교환기의 공기측 습표면 성능 (Wet Surface Air-Side Performance of Fin-and-Tube Heat Exchangers Having Sine Wave Fins and Oval Tubes)

  • 김내현
    • 한국산학기술학회논문지
    • /
    • 제16권4호
    • /
    • pp.2415-2423
    • /
    • 2015
  • 본 논문은 12.7mm 원관을 변형하여 만든 세장비 0.6(짧은 직경 10.0mm, 긴 직경 16.5mm)의 타원관이 적용된 사인 웨이브 핀-관 열교환기의 습표면 공기측 성능실험에 관한 것이다. 핀 핏치와 열 수를 변화시켜 총 12개의 시료에 대하여 실험을 수행하였다. 타원관에서 핀 핏치 변화에 따른 j, f 인자의 영향은 미미 하였으나, 열수에 따라서는 1row에서 j인자가 가장 낮았다 (가장 높은 2row의 81%). 하지만 원관에서는 1row에서 가장 높게 나타나는 차이점을 보였다. 이는 타원관에 적용된 사인 웨이브 채널의 유동 특성에 기인한 것으로 판단된다. 원관 열교환기와 $j/f^{1/3}$값을 비교한 결과 1열을 제외하고는 타원관 열교환기의 전열성능이 우수함을 알 수 있다. 즉, 타원관 열교환기의 $j/f^{1/3}$값이 원관의 값보다 2열에서 1.6~2.5 배, 3열에서 1.4~2.4 배, 4열에서 1.2~1.8배 크게 나타났다.

2상 극저온 열전달 과정 계산에서의 CFD 응용 (Application of CFD to tile Calculation of 2 Phase Cryogenic Heat Transfer Processes)

  • 유걸;악해파;정모;배철호
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2011년 춘계학술대회논문집
    • /
    • pp.141-147
    • /
    • 2011
  • A two-phase numerical model for plate-fin heat exchangers with plain fins and wave fins is studied incorporating the thermodynamic properties and the characteristics of fluid flow. The numerical simulations for the two fins in cryogenic conditions are earned out by employing a homogenous two-phase flow model with the CFD code ANSYS CFX. The heat transfer coefficients and the friction factor for nitrogen saturated vapor condensation process inside two types of plate fin heat exchanger are evaluated including the effects of saturation temperature (pressure), mass flow rate and inlet vapor quantity. The convective heat transfer coefficients and friction factors will be used for design of plate-fin type heat exchangers operating under cryogenic conditions.

  • PDF

헬륨을 냉매로 사용한 1/2파장 열음향 냉동기의 실험 및 성능평가 (The construction and performance Investigation of 1/2 Wavelength Thermoacoustic Refrigerator with Helium Refrigerant)

  • 최두원;김동혁
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2006년도 하계학술발표대회 논문집
    • /
    • pp.471-476
    • /
    • 2006
  • Thermoacoustic refrigerators are operated with acoustic power to pump heat. The acoustic standing wave displaces the gas In the channels of the stack while compressing and expanding. The thermal interaction between the osillating gas he surface of the stack generates an acoustic heat pumping. in this study, a thermoacoustic refrigerator is composed of a resonator of 4cm diameter, stack of plates, heat exchangers and cooling part. Length of the hot heat exchangers, the stack of plates and the cold heat exchanger are 9mm, 8mm and 6mm respectively. Using helium as a coolant at frequency of 516Hz, the cold-part temperature of exchanger fell to $-19.0^{\circ}C$ after 1hours.

  • PDF

Reduction of the Wet Surface Heat Transfer Coefficients from Experimental Data

  • Kim, Nae-Hyun;Sim, Yong-Sub
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제12권1호
    • /
    • pp.37-49
    • /
    • 2004
  • Four different data reduction methods for the heat transfer coefficients from experimental data under dehumidifying conditions are compared. The four methods consist of two heat and mass transfer models and two fin efficiency models. Data are obtained from two heat exchanger samples having plain fins or wave fins. Comparison of the reduced heat transfer coefficients revealed that the single potential heat and mass transfer model yielded the humidity-independent heat transfer coefficients. Two fin efficiency models-enthalpy model and humidity model-yielded approximately the same fin efficiencies, and accordingly approximately the same heat transfer coefficients. The heat transfer coefficients under wet conditions were approximately the same as those of the dry conditions for the plain fin configuration. For the wave fin configuration, however, wet surface heat transfer coefficients were approximately 12% higher. The pressure drops of the wet surface were 10% to 45% larger than those of the dry surface.

사인 웨이브 휜-관 열교환기의 공기측 성능에 관한 실험연구 (An Experimental Investigation on the Airside Performance of Fin-and-Tube Heat Exchangers Having Sinusoidal Wave Fins)

  • 김내현;조진표;윤백
    • 설비공학논문집
    • /
    • 제16권4호
    • /
    • pp.355-367
    • /
    • 2004
  • The heat transfer and friction characteristics of the heat exchangers having sinusoidal wave fins were experimentally investigated. Twenty-nine samples having different waffle heights (1.5 mm and 2.0 m), fin pitches (1.3mm to 1.7mm) and tube rows (one to three) were tested. Focus was given to the effect of the waffle configuration (herringbone or sinusoidal) on the heat transfer and friction characteristics. Results show that the sinusoidal wave geometry provides higher heat transfer coefficients and friction factors than the herringbone wave geometry, and the difference increases as the number of row increases. The i/f ratios of the herringbone wave geometry, however, are larger than those of the sinusoidal wave geometry. Compared to the herringbone wave geometry, the sinusoidal wave geometry yielded a weak row effect, which suggests a superior heat transfer performance at the fully developed flow region. Possible explanation is provided considering the flow characteristics in wavy channels. Within the present geometric range, the effect of the waffle height on the heat transfer coefficient was not prominent. The effect of the fin pitch was also negligible. Existing correlations highly overpredicted both the heat transfer coefficients and friction factors. A new correlation was developed using the present data.

Airside Performance of Convex Louver Fin-and-Tube Heat Exchangers

  • Kim, Nae-Hyun;Oh, Wang-Kyu
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제16권3호
    • /
    • pp.100-107
    • /
    • 2008
  • The heat transfer and friction characteristics of heat exchangers having convex louver fins are experimentally investigated, and the results are compared with those of wave fin counterparts. Eighteen samples (nine convex louver fin samples and nine wave fin samples) which had different fm pitches (1.81 mm to 2.54 mm) and tube rows (one to four) were tested. The convex angle was $11.7^{\circ}$. The j factors are insensitive to fin pitch, while f factors increase as fin pitch increases. The effect of fin pitch on f factor is more significant for the wave fin compared with the convex louver fin. It appears that the complex fin pattern of the convex louver fin induces intense mixing of the flow, and thus reduces the effect of fin pitch. Both the j and f factors decrease as the number of tube row increases. However, as the Reynolds number increases, the effect of tube row diminishes. Comparison of the convex louver fin j factors with those of wave fin reveals that convex louver fin j factors are 18% to 29% higher than those of wave fin. The f factors are 16% to 34% higher for the convex louver fin. The difference increases as fin pitch decreases. Existing correlation fails to adequately predict the present data. More data is needed for a general correlation of the convex louver fin geometry.