A Study on the Effects of Absorptive Treatments for the Highway Noise Barriers (도로교통소음의 방음벽 흡음효과에 관한 연구)

  • 김재석;루이스칸;김갑수
    • Journal of KSNVE
    • /
    • v.8 no.1
    • /
    • pp.146-156
    • /
    • 1998
  • To mitigate excessive noise from highways, and high speed rail road, it is often necessary to construct a noise barrier. Absorptive barroer attenuation solution is obtained for the problem of diffration of a plane wave sound source by a semi-infinite plane. A finite region in the vicinity of the edge has an highly absorbing boundary condition ; the remaining portion of the half plane is rigid. The problem which is solved is a mathematical model for a hard barrier with an absorbing edge. If the wavelength of the sound is much smaller than the length scale associated with the barrier, the diffraction process is governed to all intents and purpose by the solution to a standard problem of diffraction by a semi-infinite hard plane with an absorbent edge. It is concluded that the absorbing material that comprises the edge need only be of the order of a wavelength long to have approximately the same effect, on the sound attenuation in the shadow side of the barrier. Traffic noise is composed of thousands of sources with varying frequency content. To simplify noise predictions when barriers are present, an effective frequency of 550Hz may be used to represent all vehicles. The wavelength of sound at f=550Hz for traffic noise is about 2 feet. According to the above conclusion, an absorptive highway noise barrier is only needed to cover to cover approximately a 2 foot length of absorbing material. It would be more economical to cover only the region in the immediate vicinity of the edge with highly sound obsorbent material.

  • PDF

Study on the Shape of Appendage for the Reduction of Motion of Floating Wind Turbine Platforms (부유식 풍력 하부구조물의 운동 저감을 위한 부가물 형상 연구)

  • Dae-Won Seo;Jaehyeon Ahn;Jungkeun Oh
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.28 no.7
    • /
    • pp.1201-1208
    • /
    • 2022
  • In general, to maximize the supply and efficiency of floating offshore wind power generation energy, the motion caused by wave attenuation of the substructure must be reduced. According to previous studies, the motion response was reduced due to the vortex viscosity generated by the damping plate installed in the lower structure among the waves. In this study, a 5 MW semi-submersible OC5 platform and two platforms with attenuation plates were designed, and free decay experiments and numerical calculations were performed to confirm the effect of reducing motion due to vortex viscosity. As a result of the model test, when the heave free decay tests were conducted at drop heights of 30 mm, 40 mm, and 50 mm, compared with the OC5 platform, the platform with two types of damping plates attached had relatively improved motion damping performance. In the model test and numerical calculation results, the damping plate models, KSNU Plate 1 and KSNU Plate 2, were 1.1 times and 1.3 times lower than OC5, respectively, and the KSNU Plate 2 platform showed about two times better damping performance than OC5. This study shows that the area of the damping plate and the vortex viscosity are closely related to the damping rate of the heave motion.

A New Technique for Improved Positioning Accuracy Employing Gaussian Filtering in Zigbee-based Sensor Networks (지그비 기반의 센서 네트워크에서 Gaussian Filtering 기법을 적용한 위치 추적 향상 기법)

  • Hur, Byoung-Hoe;Kim, Jeong-Gon
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.34 no.12A
    • /
    • pp.982-990
    • /
    • 2009
  • The IEEE 802.15.4 wireless sensor network is composed of the unique sensor devices to monitor and collect physical or environmental conditions. The interests in a positioning technology, which is one of the environment monitoring technologies, are gradually increased according to the development of the sensor technology and IT infrastructure. Generally, it is difficult for the positioning system using RSSI (Received Signal Strength Indication) based implementation to get accurate position because of obstacles, RF wave's delay and multipath. Therefore, in this paper, we investigate the improved positioning technologies for RSSI-based positioning system. This paper also proposes the enhanced scheme to improve the accuracy of positioning system by applying the Gaussian Filter algorithm, which is widely used for enhancing the performance of image processing system. For the implementation of proposed scheme, we firstly make a look-up tables, which represent the distance between target node and master node and corresponding RSSI value of each target node which are recorded as an average value after investigating the characteristics of attenuation of transmitted signal By applying the pre-determined look-up tables and Gaussian Filtering in the proposed scheme, we analyzed the positioning performance and compared with other conventional RSSI-based positioning algorithms.

Exploiting W. Ellison model for seawater communication at gigahertz frequencies based on world ocean atlas data

  • Tahir, Muhammad;Ali, Iftikhar;Yan, Piao;Jafri, Mohsin Raza;Jiang, Zexin;Di, Xiaoqiang
    • ETRI Journal
    • /
    • v.42 no.4
    • /
    • pp.575-584
    • /
    • 2020
  • Electromagnetic (EM) waves used to send signals under seawater are normally restricted to low frequencies (f) because of sudden exponential increases of attenuation (𝛼) at higher f. The mathematics of EM wave propagation in seawater demonstrate dependence on relative permeability (𝜇r), relative permittivity (𝜀r), conductivity (𝜎), and f of transmission. Estimation of 𝜀r and 𝜎 based on the W. Ellison interpolation model was performed for averaged real-time data of temperature (T) and salinity (S) from 1955 to 2012 for all oceans with 41 088 latitude/longitude points and 101 depth points up to 5500 m. Estimation of parameters such as real and imaginary parts of 𝜀r, 𝜀r', 𝜀r", 𝜎, loss tangent (tan 𝛿), propagation velocity (Vp), phase constant (𝛽), and α contributes to absorption loss (La) for seawater channels carried out by using normal distribution fit in the 3 GHz-40 GHz f range. We also estimated total path loss (LPL) in seawater for given transmission power Pt and antenna (dipole) gain. MATLAB is the simulation tool used for analysis.

Electromagnetic Interference Shielding Effectiveness of a Corrugated Rectangular Waveguide for an Open-Type Microwave Conveyor-Belt Dryer (개방형 마이크로파 컨베이어 벨트 건조기의 요철 직사각형 도파관 차폐효과)

  • Kim, Sung-Yeon;Bae, Sang-Hyeon;Lee, Wang-Sang
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.29 no.6
    • /
    • pp.424-432
    • /
    • 2018
  • We herein analyze and study the shielding effectiveness characteristic of an open conveyor-belt-type microwave dryer that is widely used in industry. In particular, the electromagnetic wave leakage problem of the open-type conveyor belt dryer using a general-purpose 2.45-GHz magnetron was improved by applying the corrugated rectangular waveguide. We conducted the electromagnetic simulation of the optimal shielding effectiveness characteristic with regard to the proposed waveguide structure to analyze the attenuation characteristics of the corrugated rectangular waveguide. To verify the shielding effectiveness characteristic of the fabricated corrugated rectangular waveguide by IEEE standard 299, we achieved the shielding effectiveness of more than 30 dB in the practical microwave dryer with the proposed corrugated rectangular waveguide.

A Study on Selection of Ultrasonic Transducer and Contact Material for Surface Irregularities of Stone Cultural Heritage (석조문화유산의 표면 요철도에 적합한 초음파 탐촉자 및 접촉매질 선정 연구)

  • Jo, Young Hoon;Lee, Chan Hee
    • Journal of Conservation Science
    • /
    • v.31 no.3
    • /
    • pp.267-278
    • /
    • 2015
  • In this study, the elastomer cover, a new contact material, was developed to establish the customized ultrasonic measurement considering surface irregularities of stone cultural heritages. The cover exhibits high elastic force and wear resistance because it has tensile strength of 17MPa and elongation of 625%. In addition, as a result of comparative experiments for the seven types according to transducers and contact materials including the elastomer cover, rock surface irregularities significantly affect attenuation of ultrasonic velocity. The phenomenon was more noticeable in the chiseling finish and indirect transmission measurement rather than the dabbed finish and direct transmission measurement. However, the Type F using the exponential transducer and elastomer cover showed stable P-wave velocity and high amplitude regardless of the surface irregularities. This because the elastomer cover sufficiently sticks to surface irregularities and removes pores between a transducer and a rock specimen. Therefore, the Type F should be used for the ultrasonic measurement of stone cultural heritages with surface irregularities.

Gaseous Fuel Level Measurement of Ultrasonic Wave based on Gauss Algorithm (가우스알고리즘에 의한 초음파의 가스연료레벨 계측)

  • Kim, Hong-Ju;Choi, Doo-Seuk
    • Journal of the Korea Convergence Society
    • /
    • v.9 no.4
    • /
    • pp.161-167
    • /
    • 2018
  • The amount of CNG was measured using a pressure sensor in the case of CNG vehicles. However, the current measurement method causes anxiety to the driver because it is difficult to measure the detailed amount of CNG according to various environmental conditions. This study was performed to measure the amount of CNG in CNG fuel system, and presented the method of measurement by simulating the detection system of CNG. In this experiment, a detection simulator with an ultrasonic sensor in CNG tank of Type-3 was designed, and the reception signal of the ultrasonic sensor was verified by reducing the pressure from 100 bars to 0 bars (increment=5 bars) using compressed air. As a result, the output signal voltage of the ultrasonic sensor decreased as the pressure in the tank decreased, and the it was verified that the shape of the graph was linearity.

Study on RF characteristics of voltage-controlled artificial transmission line employing periodically arrayed diodes for application to highly miniaturized wireless communication systems (초소형 무선 통신 시스템에서의 응용을 위한 주기적으로 배열된 다이오드를 이용한 전압제어형 전송선로의 RF 특성에 관한 연구)

  • Kim, Soo-Jeong;Kim, Jeong-Hoon;Jeong, Jang-Hyeon;Yun, Young
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.41 no.1
    • /
    • pp.70-75
    • /
    • 2017
  • In this paper, we studied the RF characteristics of a voltage-controlled artificial transmission line employing periodically arrayed diodes for application to highly miniaturized wireless communication systems on an MMIC (monolithic microwave integrated circuit). According to the results, the novel voltage-controlled artificial transmission line employing periodically arrayed diodes exhibited a short wave length, which was only 35.2% that of the conventional transmission line, owing to increasing capacitance. In addition, it's effective permittivity and effective propagation constant exhibited considerably higher values than those of the conventional transmission line. Furthermore, attenuation constant of the voltage-controlled artificial transmission line was far higher than that of the conventional transmission line. Using the closed-form equation, we theoretically analyzed the equivalent circuit of the voltage-controlled artificial transmission line.

The Theoretical Investigation of Phased Array Guided Waves (위상배열 유도초음파 검사의 이론적 고찰)

  • Lee, Jae-Sun;Cho, Youn-Ho;Achenbach, Jan D.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.31 no.4
    • /
    • pp.367-373
    • /
    • 2011
  • Guided waves inspection techniques that are different with inspection technique by bulk waves are widely used in pipe line evaluation due to advantages of long distance inspection. However, most of pipe lines at industrial fields are buried and/or coated. In this case, due to the attenuation effect from soil and/or coating material, there are a lot of difficulty on inspection by conventional ultrasonic technique. In this paper, guided waves propagating patterns are calculated with respect to excitation mode by Normal Mode Expansion(NME). Guided waves patterns based on excited by single transducer and guided wave focusing technique have employed to analyze focusing pattern on a pipe. A longitudinal mode and high order flexural modes are used with various number of transducers to determine sensitivity. Guided waves energy excited by multi transducer with focusing algorithm was successfully focused at a desired point.

Influence of Inner-hole Priming Location on Ground Vibration (발파공내 기폭위치가 지반진동에 미치는 영향)

  • Kim, Jae-Woong;Kang, Choo-Won;Ko, Chin-Surk
    • Explosives and Blasting
    • /
    • v.30 no.1
    • /
    • pp.29-36
    • /
    • 2012
  • In this study, the influence of priming location inside a blast hole on the ground vibration has been studied. In most of the previous studies dealing with the ground vibration, the effect of priming location in a blast hole was usually considered in a limited way. Thus, it seems that the results of the studies can be applicable only to the relevant sites. Considering the fact that the mechanism of ground vibration caused by blasting is quite complex, the priming location can have a considerable effect on the ground vibration in certain situations and be an important parameter in a blasting design. To identify the characteristics of the wave propagation according to priming locations, total 72 test blasts were carried out with different spacing, burden, drilling length, and charge, and prediction equations were derived. The characteristics of ground vibration, which was changed according to the priming location, was analyzed by using the nomogram of peak particle velocity (PPV) record. Attenuation relations, which were also dependent on the priming location, were analyzed. In this case, four different amounts of charge, that is, 0.5, 1.6, 5, and 15 kg, were used for the test. This criterion of charge amount is specified in the "Blasting design and construction guidelines to road construction" by the Ministry of Land, Transport and Maritime Affairs of Korea.