• Title/Summary/Keyword: Watt

Search Result 442, Processing Time 0.031 seconds

A Study on the Anesthetic Effects of Pulsed Nd:YAG Laser Irradiation to the Oral Mucosa and the Teeth (Nd:YAG 레이저 조사에 의한 치아 및 구강점막의 마취효과)

  • 최재갑
    • Journal of Oral Medicine and Pain
    • /
    • v.23 no.1
    • /
    • pp.1-9
    • /
    • 1998
  • The aim of the study was to evaluate the anesthetic Effecs of pulsed Nd:YAG laser irradiation to the oral mucosa and the teeth. Twenty subjects who didn't have a history of significant systemic or current oral disease were included in this study. All the subjects were divided randomly into the experimental group and the control group with 10 for each group. Pain thresholds were measured with Weighted Needle Pinprick Sensory Threshold Test for the mucosal surface of lower lip and with electric pulp test for the upper right central incisor respectively, before and immediately after pulsed Nd:YAG laser irradiation in the condition of 2 watt, 20pps for 2 minute at 10mm distance. The experiment was double-blinded clinical trial. The results were as follows : 1. The mean pain threshold of the mucosal surface of lower lip for Weighted Needle Pinprick Sensory Threshold Test was 2.94(1.00g for the contral group respectively, and there was no statistical difference between two groups. 2. The mean pain threshold of the mucosal surface of lower lip was significantly increased immediately after pulsed Nd:YAG laser irradiation. 3. The mean pain threshold of the upper right central incisor for eledtric pulp test was 34.50(4.97V in the experimental group and 34.00(13.08V in the control group respectively, and there was no statistical difference between two groups. 4. The mean pain threshold of the upper right central incisor was significantly increased immediately after pulsed Nd:YAG laser irradiation.

  • PDF

AFSO: An Adaptative Frame Size Optimization Mechanism for 802.11 Networks

  • Ge, Xiaohu;Wang, Cheng-Xiang;Yang, Yang;Shu, Lei;Liu, Chuang;Xiang, Lin
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.4 no.3
    • /
    • pp.205-223
    • /
    • 2010
  • In this paper, we analyze the impact of different frame types on self-similarity and burstiness characteristics of the aggregated frame traffic from a real 802.11 wireless local area network. We find that characteristics of aggregated frame traffic are affected by both mean frame size and the proportion of specified frame types. Based on this new knowledge, an adaptative frame size optimization (AFSO) mechanism is proposed to improve the transmission efficiency by adaptively adjusting data frame size according to the proportions of different frame types. Simulation results show that our proposed mechanism can effectively regulate the burstiness of aggregated frame traffic and improve the successful delivery rate of data frames when a fixed throughput target is set for 802.11 wireless networks.

Life Time Characteristics of OLED Device with AlOx Passivation Film Deposited by RF Magnetron Sputtering (RF 마그네트론 스퍼터링으로 증착된 AlOx 봉지 박막을 갖는 OLED 소자의 수명 특성)

  • An, O-Jin;Ju, Sung-Hoo;Yang, Jae-Woong
    • Journal of the Korean institute of surface engineering
    • /
    • v.43 no.6
    • /
    • pp.272-277
    • /
    • 2010
  • We investigated the life time characteristics of OLED device with aluminium oxide ($AlO_x$) passivation film on glass substrate and polyethylene terephthalate (PET) substrate by RF magnetron sputtering for the transparent barrier film applied to flexible OLED device. Basic buffer layer was determined as $Alq_3$(500 nm)-LiF(300 nm)-Al(1200 nm), and the most suitable aluminium oxide ($AlO_x$) film have been formed when the partial volume ratio of oxygen was 20% and the sputtering power was 100 watt and the minimum thickness of buffer was $2\;{\mu}m$. $AlO_x$/epoxy hybrid film was also used as a effective passivation layer for the purpose of improving life time characteristics of OLED devices with the glass substrate and the plastic substrate. Besides, the simultaneous deposition of $AlO_x$/epoxy film on back side of PET could result in better improvement of life time.

THE EFFECT OF ND : YAG LASER ON DENTINAL TUBULE SEAL AFTER ROOT END RESECTION (치근단절제시 노출된 상아세관의 밀폐효과에 대한 Nd : YAG 레이저의 효과)

  • Shin, Kwang-Chul;Hong, Chan-Ui
    • Restorative Dentistry and Endodontics
    • /
    • v.21 no.1
    • /
    • pp.311-320
    • /
    • 1996
  • If root and resection is done during surgical endodontic treatment, newly exposed dentinal tubules form pathways between the canal and the peripheral tissue. Nd : YAG laser was used to block this phenomenon, and its effect was studied with dye penetration and SEM techniques. 40 intact single rooted teeth were divided into 4 groups(10 each) : control group and test groups, in which retrograde cavity surface, cutting surface, retrograde cavity surface & cutting surface were treated with laser(1 watt 15pps) and finally retrograde filling with IRM was conducted. After that, they were stained with 2 % methylene blue, sectioned and evaluated by the maximum infiltration depth. And to observe surface change, they were prepared for SEM. The results were as follows ; 1. All experimental groups showed microleakage with variation in amount. 2. The 2nd group which treated both the retrograde cavity and cutting surface showed significantly less microleakage than the other groups(p<0.05). There was no significant difference between groups treated on one side only. 3. As a result of SEM observation of dentin surface, obstruction of dentinal tubules with marble shaped granules, which were different from normal dentin could be seen. Cracks could be seen also. 4. In summary of this experiment, it is thought that effort to obstruct the exposed dentinal tubules as well as retrograde cavity after root end resection is needed.

  • PDF

A Study of Exhaust Air Flow for Cooling Load Reduction from Interior Lighting (조명기구의 발열부하 저감을 위한 배기풍량 연구)

  • Oh, Byung-Kil;Chung, Min-Ho;Kim, Hway-Suh
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.23 no.9
    • /
    • pp.604-609
    • /
    • 2011
  • The increased quality of life requires indoor illumination environment to have illumination with higher intensity. The increase in indoor illumination goes hand in hand with increase in indoor heat load. Of late, the internal heat in the cooling load has been growing gradually and the proportion of the lighting load has been bigger in the cooling load. The objective of the experiment here is to estimate the proper exhaust air flow displacement to remove heat from different types of lighting equipment. The heat causing the cooling load in lighting equipment is the ratio of heat per watt and the ratio of space for heat. Experimental measurements of the constant temperature and humidity in chambers that exhaust air flow by changing the exhaust calorific value was measured. Using the Airflow exhaust heat from lighting fixture of this study should help to reduce House cooling load.

KTP-532 Laser Microlaryngeal Phonosurgery (KTP-532 레이저를 이용한 후두미세음성수술의 임상적 적용 결과)

  • Choi, Jong-Ouck;Chu, Hyung-Ro;Jung, Kwang-Yoon
    • Archives of Reconstructive Microsurgery
    • /
    • v.2 no.1
    • /
    • pp.62-69
    • /
    • 1993
  • Recently, conservative and bloodless operative procedures have been focused, so that endoscopic laser have been used. However application of endoscopic laser surgery for laryngeal lesion is capable for followings: (1)capability of delivery through an operating microscope, (2) vaporization of ultraspot. $CO_2$ laser which has been used, has limitations for voice improvement because of 700 micron beam spot. KTP-532 laser which is capable of delivery through an operating microscope vapore 200 micron ultraspot has developed and applied to microlaryngeal surgery. We have experienced 60 cases who were contracted with hoarseness(53 cases of benign lesions vocal nodule 13, vocal polyp 13, bilateral diffuse polyposis of vocal cords 11, intracordal cyst 8, vocal papilloma 5, laryngocele 1, laryngeal stenosis 2 and 7 cases of malignant lesions : laryngeal carcinoma stage I and II) since 1991. We operated them with KTP-532 Laserscope(3 Watt/0.05 sec., pulsed or continuous. San Jose, Calif, USA). Forty eigh cases(90.6%) of 53 bengin laryngeal lesions and 4 cases(57.1%) of malignant lesions were significantly improved in their voices. There were a few complications and technical problems, but laser surgery alone had a limitation to eradicate the disease.

  • PDF

A Study on Programmable Logic-based Smart Peak Power Control System (프로그램 로직 기반의 스마트 최대 전력 관리 시스템에 관한 연구)

  • Lee, Woo-Cheol;Kwon, Sung-Hyun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.28 no.2
    • /
    • pp.92-99
    • /
    • 2014
  • The paper is related to smart maximum power system based on program logic. Especially, this system compares the total demand power with the target power by using the signal from the digital kilo watt meter. Based on the power information by the maximum power control equipment the consumed future power is anticipated. In addition, through consumed future power the controllable target power is set, and it applies on the maximum power control equipment. User or manager would control the load efficiently through the simple programming which could control load based on the control sequence and relay. To begin with the conventional maximum power control algorithm is surveyed, and the smart maximum power control system based on program logic is used, and the new algorithm from full load to proportion shut down is proposed by using PLC program. the validity of the proposed control scheme is investigated by both simulation results.

High Efficient Energy Recovery Circuit for AC Plasma Display Panel (AC Plasma Display Panel 구동 장치의 고효율 전력 회수 회로에 관한 연구)

  • 윤원식;강필순;김철우
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.6 no.6
    • /
    • pp.481-488
    • /
    • 2001
  • The sustaining driver for color AC Plasma Display Panel should provide alternating high voltage pulses and recover the energy discharged from the intrinsic capacitance between the scanning and sustaining electrodes inside the panel In this paper a novel efficient energy recovery circuit employing boost-up function is proposed to achieve a faster rise-time and in order to obtain a stable sustain voltage The principle of operation. features simulated results and experiment results are illustrated and verified on a 7.5-inch-panel with 200[kHz]switch frequency.

  • PDF

Design of Amplifier Pallet for DPD Using Gallium Nitride Device (질화갈륨 소자를 이용한 DPD용 Amplifier Pallet 개발)

  • Oh, Seong-Min;Park, Jung-Hoon;Cho, Sam-Uel;Lee, Jae-Hoon;Lim, Jong-Sik
    • Proceedings of the KAIS Fall Conference
    • /
    • 2010.11a
    • /
    • pp.76-79
    • /
    • 2010
  • 본 논문에서는 고 효율 및 고 출력 특성을 가지는 질화갈륨(GaN) 소자를 이용하여 WiMAX 및 LTE System에 사용될 수 있는 DPD용 Pallet Amplifier를 제작하였다. 제작된 Pallet Amplifier는 Pre-drive로써 저 전류의 MMIC를 채택하고, Drive 단과 Main 단에 15W 급과 30W 급의 질화갈륨 소자를 사용 하였으며, 추가적인 효율 개선을 위해 PCB상에 Doherty Structure를 적용함으로써 보다 높은 효율을 구현하였다. 제작된 Pallet Amplifier는 음 전원 Bias 제어 회로, 온도에 따른 Gain 보상회로, Sequence 회로 및 Main 전원 Drop에 따른 보호 회로를 구현하였다. WiMAX Signal을 이용한 Modulation Power 10Watt Test에서 약 36.8~38.3%의 Pallet 효율과 DPD Solution인 TI GC5325SEK DPD Board 사용 시 ACLR은 약 46dBc 이상을 가지는 것으로 측정되었다. 본 논문에서 제작된 Pallet Amplifier는 Upper Band와 Lower Band로 나누어 제작되었던 기존 Pallet Amplifier와 달리 하나의 Pallet Amplifier로 2496~2690MHz에서 모두 사용하면서 종전에 사용되고 있는 Pallet Amplifier에 비해 Size가 최소 10% 이상 축소되어 효율 및 크기 면에서 종전 Pallet Amplifier보다 큰 이점을 갖는다.

  • PDF

Removable shear connector for steel-concrete composite bridges

  • Suwaed, Ahmed S.H.;Karavasilis, Theodore L.
    • Steel and Composite Structures
    • /
    • v.29 no.1
    • /
    • pp.107-123
    • /
    • 2018
  • The conception and experimental assessment of a removable friction-based shear connector (FBSC) for precast steel-concrete composite bridges is presented. The FBSC uses pre-tensioned high-strength steel bolts that pass through countersunk holes drilled on the top flange of the steel beam. Pre-tensioning of the bolts provides the FBSC with significant frictional resistance that essentially prevents relative slip displacement of the concrete slab with respect to the steel beam under service loading. The countersunk holes are grouted to prevent sudden slip of the FBSC when friction resistance is exceeded. Moreover, the FBSC promotes accelerated bridge construction by fully exploiting prefabrication, does not raise issues relevant to precast construction tolerances, and allows rapid bridge disassembly to drastically reduce the time needed to replace any deteriorating structural component (e.g., the bridge deck). A series of 11 push-out tests highlight why the novel structural details of the FBSC result in superior shear load-slip displacement behavior compared to welded shear studs. The paper also quantifies the effects of bolt diameter and bolt preload and presents a design equation to predict the shear resistance of the FBSC.