• Title/Summary/Keyword: Waterworks development

Search Result 33, Processing Time 0.019 seconds

Korea waterworks intergration promotion plan based on case analysis (수도사업 통합 사례 분석을 통한 수도사업 통합 추진 방안)

  • Kim, Kyunglok;Kim, Younghee
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.36 no.5
    • /
    • pp.275-287
    • /
    • 2022
  • In order to overcome the small scale of Korea waterworks and to achieve comprehensive improvement and innovation transformation, the waterworks integration was reviewed. The effect of consolidation was confirmed by the integration of the water supply business in the southern Gangwon region and the western Gyeongnam region in Korea, such as an increase in the flow rate and a decrease in the production unit cost. After facing management and service limitations overseas, more than 1,000 small-scale waterworks projects in the UK were integrated into 27 waterworks providers, and Japan also revised the Waterworks Act in December 2019 and is in the process of integrating waterworks. It is considered appropriate to promote the integration of waterworks projects in Korea by respecting the autonomy of local governments, but using a participatory method, a win-win method, and a linkage method. For the integration of waterworks projects, three strategies are proposed: First creating a national foundation for integration (revision of the Waterworks Act), Second establishing a waterworks integration strategy led by local governments, Third forming an external consensus and providing incentives for participation.

Development of BIM models and management of BIM data for waterworks maintenance (상수도시설물의 유지관리를 위한 BIM모델 개발 및 BIM 데이터 관리방안)

  • Park, Jaehyun;Lee, Hyundong;Kwak, Pilljae
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.28 no.6
    • /
    • pp.669-679
    • /
    • 2014
  • 3D-based BIM(Building Information Modeling) technologies can be utilized effectively as a means of systematic management of facility information for safety assurance and effective maintenance of waterworks facilities. In this study, BIM models of water treatment facilities that can be used as basic data for BIM-based maintenance of waterworks facilities were developed. Information exchange and generality of the developed BIM models were evaluated by conducting interoperability analysis of IFC(Industry Foundation Classes) conversion models. In addition, the application of COBie(Construction Operations Building information exchange) was recommended as an effective countermeasure to deal with technical limitation regarding exchange and utilization of facilities-related information through current IFC models. The results of this study can contribute to the development of BIM-based maintenance system for waterworks facilities.

A Study on the Development of Hoist Balance Controller (권양기의 밸런스제어장치 개발에 관한 연구)

  • Yoon, Jong-Beom;Lee, Jong-Chan;Choi, Jang-Geon;Lee, Jae-Hoon;Goo, Do-Hyeong
    • Proceedings of the KIEE Conference
    • /
    • 2005.07d
    • /
    • pp.2591-2593
    • /
    • 2005
  • 본 연구는 물체의 좌우측 상단에 연결된 와이어로프를 모터 및 드럼을 통하여 감아 올리거나 내려 놓는 과정에서 물체가 수평상태를 유지하여 이동될 수 있도록 Two Motor-Two Drum 형식의 권양기를 제어 하는 권양기의 밸런스제어장치에 관한 것이다. 본 연구에 Two Motor-Two Drum 형식의 권양기 제어장치에 있어서, 물체의 상단에 연견된 일측 와이어로프와 타측 와이어로프의 이동길이를 실시간으로 검출하는 와이어로프 이동길이검출부와, 이 와이어로프 이동길이검출부를 통하여 검출되는 일측 와이어로프와 타측 와이어로프의 이동길이를 비교하여 물체의 기울어진 좌 우 편차를 검출하는 편차검출부와, 이 편차검출부를 통해 검출되는 좌우 편차를 제거하기 위하여 일측 또는 타측 와이어로프가 감겨있는 드럼을 회전시키는 모터의 구동속도를 조절하여 물체를 수평상태로 보정하는 밸런스제어부로 구성 되어 있다.

  • PDF

Development of the LBS-based Water Service Information Service System (LBS 기반의 수도정보서비스시스템 개발)

  • Hwang, Eui Ho;Lee, Geun Sang
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.29 no.4D
    • /
    • pp.535-544
    • /
    • 2009
  • Even though Korea's national project - NGIS(National Geographic Information System) has been built since 1995 and the GIS database for underground facilities has also been built, not so many systems are utilizing those databases currently. Also, the waterworks GIS developed and operated by K-Water is not used effectively in supporting field works. In order to manage and operate the waterworks pipelines effectively, systematic supporting strategy must be established by adopting the state-of-the-art technology. In this research, a ubiquitous-based strategy for managing waterworks facilities is proposed to increase the usability of the existing related databases and to ensure the systematic way of distributing information. The current status of the existing waterworks GIS and GIS database were analyzed to achieve the goal. By studying the state-of-the-art technology, we found that importing the LBS technology to the databases is necessary. The results of these efforts are exclusive waterworks-mobile-terminals and LBS system supporting them. Furthermore, the applicability of the ubiquitous technology to waterworks has been examined to realize the real-time waterworks management.

Development of Water Management System for Optimal Operation and Control in Wide-area Waterworks (광역상수도의 최적운영 및 제어를 위한 수운영시스템 개발)

  • 남의석;우천희;김학배
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.9 no.7
    • /
    • pp.489-497
    • /
    • 2003
  • A water management system is developed to reduce the unit cost of production in wide-area waterworks. Improving productivity in waterworks is to save power rate. We suggest a method to schedule the supply of water according to the time-varying power rate and pump control scheme. Water pipeline analysis package (SynerGEE Water) is utilized to obtain optimal pump control solution adaptation to water demand. Our evaluation results show that developed scheme is more efficient than the conventional.

Development of Alarm System Using Fault Tree Analysis for Pumping Station and Reservoir of Waterworks (Fault Tree 분석에 의한 상수도 가압장과 배수지의 경보시스템 구축)

  • Ahn, Yong-Po;Song, Moo-Geun;Lee, Dong-Ik
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.25 no.6
    • /
    • pp.847-859
    • /
    • 2011
  • This paper presents an alarm system for the integrated monitoring and control station of waterworks in Daegu City. An alarm system informs the operator or other responsible individuals about the abnormality in the process so that an appropriate action can be taken. In practice, operators receive far more false and nuisance alarms than valid and useful alarms. Too many false and nuisance alarms can distract the operator from operating the plant, and thus critical alarms may be ignored. This problem can lead to the point that the operator no longer trusts the alarms or even shuts down the whole monitoring system. This paper proposes an efficient method to reduce false and nuisance alarms by prioritizing every fault using the Fault Tree Analysis (FTA) technique. The effectiveness of the proposed method is evaluated with a set of computer simulation under various faulty conditions.

Study on Introduction to Predicting Indicator of Cyanobacteria Dominance in Algae Bloom Warning System of Hangang Basin (한강유역 조류경보제에 남조류 우점 예측인자 도입에 관한 연구)

  • Kim, Tae Kyun;Choi, Jae Ho;Lee, Kyung Ju;Kim, Young Bae;Yu, Sung Jong
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.36 no.5
    • /
    • pp.378-385
    • /
    • 2014
  • The chlorophyll-a concentration in algae bloom warning system of Hangang basin did not predict the cyanobacteria dominance. In this study, suggest the predicting indicator of cyanobacteria dominance through analyzing the environmental factors affecting on the cell count of cyanobacteria. Firstly, the dominance of algae was analyzed with seasonal variation during Jan. 2012~Sep. 2013. The diatom dominated phytoplankton communities during the period of January~April. In the May~June, the green algae dominated. And, the dominance of algae was changed to cyanobacteria in the July~August. Also, the environmental factors affecting to cyanobacteria blooms ; nutrients (TN, TP), temperature, precipitation, dam-discharge were evaluated during the study period. Rather than temperature factor, relatively low dam discharge causes cyanobacteria to grow rapidly and create a blooms. The low dam-discharge may increase the water retention time. Finally, it is proved that a low ratio of TN to TP (<29:1) can favour the development of cyanobacteria blooms. Thus, the predicting indicator (TN:TP) have need to apply to the alarm bloom warning system of Hangang basin.

A Study of Filtralite Media Applicability for Development F/A Process of Membrane Filtration Pre-treatment Process in the Water Purification Plant (정수장에서 막여과 전처리용 F/A 공정 개발을 위한 Filtralite 여재의 적용성 연구)

  • Kim, JUN-Hyun;Jun, Yong-sung;Kwak, Young-ju;Jang, Jung Woo
    • Membrane Journal
    • /
    • v.25 no.6
    • /
    • pp.503-514
    • /
    • 2015
  • In this study, water purification system without coagulant was consisted of F/A and membrane to produce purified water which only uses physical treatment without coagulant. Because the use of coagulant has a possibility remaining of hazardous aluminum with our health. Especially, the Filtralite was reviewed the possibility to remove turbidity and organic material. It was found that the turbidity removal rate of Filtralite was 83~84%. It show that Filtralite has similar efficiency to sand-filter. But Filtralite has higher 50% removal rate of organic material than sand-filter due to well-developed pore on the surface of it. So, Filtralite could be used to substitute the sand-filter for the F/A process due to higher removal rate. And also coupled with activated carbon in F/A process, TMP was increased by TOC value. To prevent increasing TMP, media that has outstanding organic adsorption ability should be used.

The Development of Corrosion Standard System of Water and Wastewater in Soil Environment (상·하수도 배관재의 토양환경에서의 부식표준시스템 개발)

  • Park, Kyeong-Dong;Shin, Yeong-Jin;Lee, Ju-Yeong
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.5 no.4
    • /
    • pp.7-12
    • /
    • 2006
  • Galvanized steel pipe, copper pipe and stainless steel pipe, which is being used in waterworks piping materials. In case of galvanized steel pipe, the precipitation of a product is being generated due to the pollution of the tap water, a white water phenomenon, and various corrosion reaction because a zinc ion is melted by tap water. And in case of a cupper pipe, many problems which is harm in sanitation appeared because of a inflow of harmfulness substance by a frequent accident of a water leakage. So, to prevent these problems, it is substituted for stainless steel pipe. However, those problems is still occurring because of badness of welding, a problem of a water leakage in connection part, and a increment of construction expenses. Therefore, this research has examined the laying period according to each piping thickness and a corrosion shape according to each laying depth after laying in various soils(sandy loam, loamy, clay loam, clay) using galvanized steel pipe, copper pipe, and stainless steel pipe. That is, we has studied the data which is necessary for a rational method of preserving the quality of water by examining the corrosion properties of piping materials in the soil environment which waterworks piping materials is being used.

  • PDF