• Title/Summary/Keyword: Waterproof operation

Search Result 19, Processing Time 0.025 seconds

Studies on the Control of AtoN Charge and Discharge Controller (항로표지 충·방전조절기의 제어에 관한 연구)

  • Ye, Seong-hyeon;Han, Soonhee
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2014.10a
    • /
    • pp.654-657
    • /
    • 2014
  • In this paper, we proposed a short distance control method of AtoN charge and discharge regulator. The proposed control measures, was constructed by applying the communication standards NEMA018 of AtoN and control function analysis of the charge and discharge regulator that has been operating in the country. By using the control method is proposed, while maintaining the waterproof without product degradation, there is an advantage that can communicate control wired or wireless. Also, it is possible to ensure the accessibility of the charge and discharge regulator in operation, it is effective for maintenance. In this paper, installed the application to control the charge and discharge regulator to the smart-phone. by using a PC and Blue-tooth communication, to examine the effectiveness of the control information. Future, control method of power controller, can provide a national standard.

  • PDF

A modified shell-joint model for segmental tunnel dislocations under differential settlement

  • Jianguo Liu;Xiaohui Zhang;Yuyin Jin;Wenyuan Wang
    • Geomechanics and Engineering
    • /
    • v.35 no.4
    • /
    • pp.411-424
    • /
    • 2023
  • Reasonable estimates of tunnel lining dislocations in the operation stage, especially under longitudinal differential settlement, are important for the design of waterproof gaskets. In this paper, a modified shell-joint model is proposed to calculate shield tunnel dislocations under longitudinal differential settlement, with the ability to consider the nonlinear shear stiffness of the joint. In the case of shell elements in the model, an elastoplastic damage constitutive model was adopted to describe the nonlinear stress-strain relationship of concrete. After verifying its applicability and correctness against a full-scale tunnel test and a joint shear test, the proposed model was used to analyze the dislocation behaviors of a shield tunnel in Shanghai Metro Line 2 under longitudinal differential settlement. Based on the results, when the tunnel structure is solely subjected to water-earth load, circumferential and longitudinal joint dislocations are all less than 0.1 mm. When the tunnel suffers longitudinal differential settlement and the curvature radius of the differential settlement is less than 300 m, although maximum longitudinal joint dislocation is still less than 0.1 mm, the maximum circumferential joint dislocation is approximately 10.3 mm, which leads to leakage and damage of the tunnel structure. However, with concavo-convex tenons applied to circumferential joints, the maximum dislocation value reduces to 4.5 mm.

A study on the data transmission performance for the development of the telesounder based on LTE communication system (LTE 통신 시스템 기반의 원격 어군탐지기 개발을 위한 데이터 전송 성능에 관한 연구)

  • HEO, Gyeom;HWANG, Doo-Jin;KANG, Tae-Jong;SHIN, Hyeon-Ok
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.58 no.2
    • /
    • pp.153-158
    • /
    • 2022
  • A telesounder is a device that can monitor the appearance of fish in the sea on land and store fish detection data. This study was conducted to monitor the appearance of fish resources in coastal or near seas by using LTE communication for data transmission of the telesounder. The purpose of this study was to develop a prototype telesounder that can monitor the appearance of fish groups in the waters about 50 km away from the coast and store fish detection data. In this study, the prototype telesounder including a fish finder, communication device and battery for stable operation at sea was developed. The stability of telesounder buoy, data transmission/reception and expected use time were investigated. The expected use time of the telesounder using LTE communication with a lithium battery (12 V, 120 Ah) was about 274 hours under the conditions of 10 minutes off and 10 minutes on, about 520 hours under the conditions of 30 minutes off and 10 minutes on, and about 142 hours under continuous conditions. As a result of the sea test, it was found that the telesounder can be used in the sea area moved about 34 km from the land and the telesounder buoy was evaluated to have secured basic stability (buoyancy balance, waterproof, antenna strength, etc.) for operation in a marine environment.

A study of Double Sheet Multi-forming Equipment (2겹 판재 멀티포밍 장치에 관한 연구)

  • Yun, Jae-Woong;Son, Ok-Jong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.3
    • /
    • pp.49-55
    • /
    • 2017
  • Most motor cases adopt deep drawing products, which are excellent in waterproof functions, concentricity, right angle, and quality. In addition, the blower motor and seat motor, which are installed in the car interior and do not require waterproof function, adopts a multi-forming manufacturing method. The deep drawing process requires an expensive transfer press that can digest approximately 12 processes, such as drawing, trimming and piercing. On the other hand, products can be produced with low investment because the multi-forming method is composed of one multi-forming machine or one multi-forming machine and one press. The multi-forming machine is a high-priced facility that is mostly imported and a bending / shearing process multi-foaming machine, which was developed by domestic small and medium-sized enterprises, is not enough to reduce the production cost. An integral multi - forming machine is used as a limited working method for thin material and small products. A large product and thick material has a high shear load. A large product and thick material has a high shear load and uses a single crank press. After blanking, the worker manually feeds the material to a multi-forming machine. When the bending operation is performed in the multi-forming machine, it is transferred to the press again to calibrate the dimensions. This variance in work processes has resulted in lower cost competitiveness due to the lower productivity, quality issues, and excessive operator input. The aim of this study was to establish a stable and cost - effective production system through bending / shearing process separation and facility automation.

An Empirical Study on the Standard Re-establishment of Water Discharge Performance for the Fire Engine Pump (소방차 펌프의 방수성능 기준 재정립을 위한 실증적 연구)

  • Min, Se-Hong;Kwon, Yong-Joon
    • Fire Science and Engineering
    • /
    • v.26 no.5
    • /
    • pp.85-91
    • /
    • 2012
  • This paper analyzed firefighting officers' use situations such as the use time, maximum working pressure, hose diameter, etc. of fire pumps at fire sites and carried out various performance tests by pressures, hose diameters and quantities of fire pumps based on its results because the waterproof performance criterion for a fire pump installed in a fire engine is different from the operation situations at the site and is not clearly prescribed. As a result of site survey, the site uses a higher pressure than the standard water discharge pressure (0.85 MPa) or the high-pressure water discharge pressure (1.4 MPa) prescribed by the approval Standard of the fire pump performance on fire truck. In addition, as a result of pump performance test, the discharged water flow rate, water discharge pressure, etc. was measured to be very different from the currently prescribed the approval standard depending on the hose diameter and firefighting nozzle, so the result of this study proposes a new standard.

A Study on the Investigation of Demander's Consciousness for Standardization and Information of Construction Materials (건설자재 표준화 및 정보활용에 대한 수요자 의식 조사 연구)

  • Choi, Young-Jun;Cho, Young-Keun;Kwon, Ki-Jun;Chae, Seong-Tae
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.7 no.2 s.25
    • /
    • pp.7-12
    • /
    • 2007
  • This study has been conducted to present reform recommendations for Standardization of Construction Materials, based on a study on the Investigation of Demander's Consciousness for Construction Materials Quality and Information Standardization in Korea. Upon investigation, it was found that the quality of Korea Industrial Standards (KS) was given 67 points (out of 100) by respondents. In addition, 38% of the respondents showed that they had problems with a lack of Standardized Information. Good examples were found to be non-standardized materials, e.g. admixtures, waterproof agents, reinforcing fibers, concrete, aggregates, adhesives, wood, temporary materials, thermal-insulating materials, etc. Upon results from the investigation of demander's consciousness for infrastructure of standardization of information, 71.2% of respondents thought that it is necessary to informatize construction materials. They made following demands on the informatization to be, in order: Quality, Standard, Price (Cost), Operation, Drawing, Law, and Information.

A Study on the Institutional Improvement for the Employment Stability of Foreign Workers in the Construction Industry (건설업의 외국인 근로자 고용안정을 위한 제도적 개선방안 도출 연구)

  • Cho, Jae-Hwan
    • Journal of the Society of Disaster Information
    • /
    • v.15 no.4
    • /
    • pp.514-523
    • /
    • 2019
  • Purpose: This study was designed to provide necessary institutional improvements for job security for foreign workers in the domestic construction sector. Method: I analyzed the National Statistical Office and related reports to investigate the status of foreign workers. Based on this, the government came up with measures to improve the system. Results: Based on the current comparative advantage index (RCA) analysis, the technology standard of foreign workers compared to Korean workers was evaluated, and the results were analyzed in order of moldwork, rebar, concrete work, stone work, and waterproof work. Conclusion: A foreign worker's work system was introduced to solve the problem of local Lunar New Year's Day field manpower. To ensure stable implementation of the system, there is a need to improve the operation of the employment permit system at construction sites and limit the size of the construction industry that introduces the employment permit system.

Development of New Ocean Radiation Automatic Monitoring System (새로운 해양 방사선 자동 감시 시스템의 개발)

  • Kim, Jae-Heong;Lee, Joo-Hyun;Lee, Seung-Ho
    • Journal of IKEEE
    • /
    • v.23 no.2
    • /
    • pp.743-746
    • /
    • 2019
  • In this paper we proposed a new ocean radiation automatic monitoring system. The proposed system has the following characteristics: First, using NaI + PVT mixed detectors, the response speed is fast and precision analysis is possible. Second, the application of temperature compensation algorithm to scintillator-type sensors does not require additional cooling devices and enables stable operation in the changing ocean environment. Third, since cooling system is not needed, electricity consumption is low, and electricity can be supplied reliably by utilizing solar energy, which can be installed at the observation deck of ocean environment. Fourth, using GPS and wireless communications, accurate location information and real-time data transmission function for measurement areas enables immediate warning response in the event of nuclear accidents such as those involving neighboring countries. The results tested by the authorized testing agency to assess the performance of the proposed system were measured in the range of $5{\mu}Sv/h$ to 15mSv/h, which is the highest level in the world, and the accuracy was determined to be ${\pm}8.1%$, making normal operation below the international standard ${\pm}15%$. The internal environmental grade (waterproof) was achieved, and the rate of variation was measured within 5% at operating temperature of $-20^{\circ}C$ to $50^{\circ}C$ and stability was verified. Since the measured value change rate was measured within 10% after the vibration test, it was confirmed that there will be no change in the measured value due to vibration in the ocean environment caused by waves.

Electric Circuit Analysis for PV Array on Short-Circuit Failure of Bypass Diode in PV Module (PV모듈의 바이패스 다이오드 단락 고장 시 태양광어레이 회로 특성분석)

  • Lee, Chung-Geun;Shin, Woo-Gyun;Lim, Jong Rok;Hwang, Hye-Mi;Ju, Young-Chul;Jung, Young-Seok;Kang, Gi-Hwan;Chang, Hyo-Sik;Ko, Suk-Whan
    • Journal of the Korean Solar Energy Society
    • /
    • v.39 no.6
    • /
    • pp.15-25
    • /
    • 2019
  • As the installation of photovoltaic systems increases, fire accidents of PV system grow every year. Most of PV system fires have been reported to be caused by electrical components. The majority of fire accidents occurred in combiner box, which is presumed to be short-circuit accidents due to dustproof and waterproof failures or heat deterioration of blocking diode. For this reason, the blocking diode installation became optional by revised PV combiner regulation. In this paper, according to the revised regulation, reverse current that generated by voltage mismatch was measured and analyzed in PV array without a blocking diode. The factors that cause voltage mismatch in array are assumed to be shaded PV module and short circuit failure of bypass diode. As the result of experiment, there is no reverse current to flow under shading condition in module, but reverse current flows on the failure of bypass diode in module. According to the module's I-V characteristic curve analysis, open voltage was slightly reduced due to operation of bypass diode in shading. However, it showed that open circuit voltage has decreased significantly in the failure of bypass diode. This indicates that the difference in open voltage reduction of voltage mismatch factor causes reverse current to flow.