데이터센터의 외기도입 냉방시스템 적용에 따른 경제성 평가 (Economic Evaluation of Air-side Economizer System for Data Center)

  • 박성현;서장후
    • 설비공학논문집
    • /
    • 제26권4호
    • /
    • pp.145-150
    • /
    • 2014
  • Many studies are being conducted with the aim of reducing the energy consumption in data centers, which are one of the highest consumers of energy. The use of an air-side economizer system that uses external air during intermediate and winter seasons is being considered for reducing the energy consumption of air conditioners. In this study, using the energy simulation, we evaluated the energy performance of a central chilled water cooling system and air-side economizer system in domestic data centers. Further, the cost-effectiveness of the air-side economizer was analyzed through Life-Cycle Cost Analysis. The results showed that with the use of air-side economizer systems, the energy costs increased as the applied filter grade increased; however, unlike existing central chilled water systems, it would break even within 2 years.

고밀도 내부부하 중심 건물의 에너지 절약적 공조방식에 대한 연구 (Viability of HVAC System for Energy Conservation in High Density Internal-load Dominated Buildings)

  • 조진균;정차수;김병선
    • 설비공학논문집
    • /
    • 제22권8호
    • /
    • pp.530-537
    • /
    • 2010
  • With the advancement of technology, the density of IT equipment, heat load and power consumption continue to increase in high density internal-load dominated buildings as datacenters. To improve the HVAC system's energy performance and efficiency, there is a need to find methods of using outside air. Through cooling tower control that is based on outside wet-bulb temperature, the water-side economizer made it possible to achieve a maximum energy performance improvement of about 16.6% over the basic chilled water system, whereas the air-side economizer, through control based on outdoor air enthalpy, made it possible to achieve about 42.4% improvement.

데이터센터에 적용된 외기도입 냉방시스템에서 필터유형별 에너지 소비량 변화 (Energy Consumption Analysis based on Filter Differential Pressure when Adopting an Air-side Economizer System for a Data Center)

  • 박성현;서장후;정용호;장현재;황석호
    • 설비공학논문집
    • /
    • 제25권7호
    • /
    • pp.371-376
    • /
    • 2013
  • Recently, many studies related to reducing the energy consumption in data centers have been conducted. These studies have mainly focused on the air intake and exhaust system of a computer room air handling unit (CRAH) in the server room, diffuser type, suppression and discharge of the heat generated from the server, and the air-side economizer system. In this study, the energy consumption of the conventional central chilled water cooling system is compared with the energy consumption of the air-side economizer system. We also examined how changes of differential pressure by each filter have influenced energy consumption, using the power usage effectiveness (PUE). Results show that the PUE was improved, and energy consumption decreased, by applying the air-side economizer system.