• 제목/요약/키워드: Water-purifier tank

검색결과 11건 처리시간 0.025초

대규모 아파트 단지주변 하수관로의 악취 발생과 대책 II: 주거지역 하수관로의 악취원인과 대책 (The Foul Smelling from Sewer Pipe near Large Apartment Complexes and its Countermeasures II: The Cause for Foul Odors of Sewer Pipes in Residential Areas)

  • 이장훈;강선홍
    • 상하수도학회지
    • /
    • 제21권5호
    • /
    • pp.631-639
    • /
    • 2007
  • This study investigated the construction and operation status of sewer pipes and water-purifier tanks near densely populated areas like large apartment complexes, in order to find out cause for offensive orders. The study results revealed that the main cause arose from the water-purifier tank and public sewer pipes near ordinary residential areas. First, in case of independent water-purifier tanks, the air is forced into the rotten part of large tanks nearby which should be operated in an anaerobic state, so that the tank changes into an aerobic state, or dirty water, which is returned during the sludge return process, falls on the top of the rotten tank, preventing scum from forming within the tank. Such problems cause incompletely purified water in the purifier tank to be discharged, which in turn results in filthy water. Second, in case of public sewer pipes, deteriorated or aging pipes, or the mixture of rain water and dirty water by mixing up combined and separated sewers system can cause foul odors in residential areas. Therefore, offensive odors in residential areas can be radically reduced through the appropriate construction and management of facilities including water-purifier tanks. As well, if more separate sewers are installed as part of an improvement project for public sewer pipes, complaints about foul smell can be minimized.

순간냉각식 정수기 냉수조의 설계변수에 따른 성능 특성에 관한 해석적 연구 (Analytical Study on the Performance Characteristics of an Instant Cooling Type Water Purifier with the Design Parameters of the Cooling Tank)

  • 전용석;박홍희;이주성;김용찬
    • 설비공학논문집
    • /
    • 제24권7호
    • /
    • pp.545-552
    • /
    • 2012
  • The objective of this study is to analyze the effect on the energy consumption of an instant cooling type water purifier by the design parameters of the cooling tank. Initially, the simulation program was developed and verified. The simulation results showed that the energy consumption was reduced by replacing the shape of the cooling tank from a rectangular to a cube, increasing the evaporator length, decreasing the volume of the cooling tank, and increasing the performance of the insulator. The order of the effect magnitude on the energy consumption was as follows; volume of the cooling tank, conductivity and thickness of the insulator, shape of the cooling tank, length of the evaporator, and length of the water tube.

고용량 방사성옥소 치료병실의 오.폐수 저감화를 위한 연구 (On decrease program of Radioactive Wastewater and Sewages in High Dose Radioiodine Therapy Ward)

  • 류재광;정우영;신상기;조시만
    • 핵의학기술
    • /
    • 제12권1호
    • /
    • pp.19-26
    • /
    • 2008
  • 목적: 방사성옥소 치료병실로부터 발생한 오 폐수는 반드시 전용 정화조에서 일정시간 자연 감쇄(decay)시켜 수중 방사능 농도치가 $8.1{\times}10^{-13}$ Ci/ml 이하가 될 때에만 비로소 방류를 하여야 한다. 현재까지 서울아산병원에서는 60 ton 용량의 전용정화조 3개를 구비하여 운영하고 있었지만 2005년 10월부터 방사성옥소 치료병실을 2병상에서 4병상으로 증설 운영함에 따라 급격히 늘어난 방사성 오.폐수량으로 인하여 본원의 정화조 용량으로는 충분한 감쇄(약 125일 이상)여력이 부족하게 되었다. 따라서 본 연구에서는 치료병실 정화조의 오 폐수 유입유량에 기여하는 원인 및 요인들을 밝혀내어 합리적인 개선 조치를 함으로써 정화조 용량 부족 문제를 해결하여 1차적으로는 엄청난 병원의 경제적 손실을 유발시키는 새로운 정화조의 증설을 피하고 방사성 물질의 인위적 배출로 인한 사회적 문제 유발에 따른 대형의료기관의 신뢰도 추락의 예방에 큰 목적이 있다. 대상 및 방법: 2006년 1월부터 10월까지 고용량 옥소 치료 환자 중 150~200 mCi 이상을 투여 받고 2박3일간 입원치료를 하는 환자 402명을 대상으로, 환자 1인당 평균 물 사용량 (변기사용량, 샤워량, 세면량, 기타 등등)을 측정하였으며, 본원의 정화조 60 ton 3개의 만수 후 배출까지의 감쇄 기간을 측정하였다. 또한 본원의 치료 업무 절차를 단계별로 분석하여 정화조 유입유량의 증가 요인을 찾아보았다. 결과: 다음과 원인에 대한 개선을 통하여 본원의 방사성 오 폐수 보관일수를 정화조 1개당 84일에서 2005년 12월말 현재 약 130일로 증가시킬 수 있었다. (1) 기존 변기의 과다한물 소모량 개선 $\rightarrow$ 절수형 변기로 교체 (2) 불필요한 샤워 및 세탁 방지 $\rightarrow$ 샤워 노즐 사용 자제 및 세면대 이용 교육 (3) 치료기간 중 잦은 배뇨를 유발하는 이뇨제 복용 중지 (4) 수분 섭취량과 퇴원시 체내 잔류선량과의 상관관계 분석 (5) 입실 후 치료 전까지의 대기시간에는 외부 화장실 사용 교육 (6) 정화조 만수위 용량 한계치를 최대 85%에서 90%로 증대 운용 결론: 근래에 들어 급격하게 증가된 갑상선질환 관련 환자로 인하여 전국적으로 거의 모든 의료기관에서 방사성옥소치료의 대기일 수가 크게 증가되고 있다. 이러한 시점에 발생된 방사성 오 폐수 관련 문제는 비단 어느 한 의료기관의 문제가 아닌 관련 우리 모두가 해결해야 하는 큰 과제임에 틀림 없을 것이다. 따라서 본 개선 활동은 그 시작을 알리는 신호탄이 될 것이라 생각되며 방사성 치료병실을 운영하고 있는 타 의료기관에서도 이와 관련된 유사상황이 발생된다면 합리적인 정화조운영의 모델방안으로 제시 될 수 있을 것으로 기대된다.

  • PDF

개인하수처리시설의 제도개선에 관한 연구 (The System Improvement of the Individual Sewage Treatment System)

  • 장효주;이장훈;강선홍
    • 상하수도학회지
    • /
    • 제24권1호
    • /
    • pp.33-40
    • /
    • 2010
  • Individual sewage treatment system is classified into a sewage treatment system which treats all the domestic sewage and a water-purifier tank which treats only effluent flushing from the toilet. The number of registered manufacturers has increased rapidly since 2001. As a result, price competition has increased among the manufacturers and has caused the problems such as the inappropriate production of individual sewage treatment system, the unreasonable permit for building completion and the shortage of the professional technology of the community's public officials in charge. This study collected the problem cases that are related with existing individual sewage treatment system and operation. Efficient improvement plan for the stable supply, installation, maintenance of individual sewage treatment system were suggested.

UV/TiO2 수처리 공정에서의 살균에 관한 연구 (A Study on the matter of Disinfection in UV/TiO2 Water Treatment process)

  • 이규환;이상진;이용재;이동석
    • 산업기술연구
    • /
    • 제27권A호
    • /
    • pp.15-18
    • /
    • 2007
  • This study investigated disinfection effect by general water purifier and water purifier with UV light disinfection. The results are as follows : (i) The general bacteria existed plentifully in a storage tank before treatment (ii) Water treated in water purifier did not meet the water treatment regulation standard since the presence of bacteria, whereas with UV light application the regulation standard is totally satisfied. (iii) Photocatalytic disinfection process with UV light in the presence of $TiO_2$ more effectively killed general bacteria than UV light only.

  • PDF

대규모 아파트 단지주변 하수관로의 악취 발생과 대책 1: 주거지역 하수관로의 악취 발생 특성 (The Foul Smelling from Sewer Pipe near Large Apartment Complexes and its Countermeasures I: Characteristics of the Foul-Smelling Sewer Pipe in Residential Areas)

  • 이장훈;강선홍
    • 상하수도학회지
    • /
    • 제21권5호
    • /
    • pp.621-629
    • /
    • 2007
  • This study intends to investigate the characteristics of the foul smell of sewer pipes near large apartment complexes as complaints about offensive odors have drastically increased in urban residential areas. Targeting apartments where people actually complained about foul orders, the study result revealed that components in the smell of the water-purifier tank of the target apartment were very similar to those of sewage treatment plants and night soil treatment plants. Measuring components of odors inside the management layer of tank showed that the concentration of hydrogen sulfide was 10ppm, which is approximately 160 times the safety standard of 0.06ppm; the concentration of mercaptan was 0.9ppm, which is about 220 times the safety standard of 0.004ppm. The source materials of foul odors were discharged outside through ducts, and those households living near outlets producing bad smell complain that it gets worse depending on the air pressure or wind direction and strength, and they could not even open windows. As well, these source materials were transferred by discharge pumps to public sewer pipes outside the apartment complex. While discharge pumps starts operating, they remain on the sewer pipe and then begin to spread over to roads through small openings of manholes on the road. Then, the smell offends passers-by and residents near the road, leading to a lot of complaints. The study results suggest that, among the sources of foul odors in sewer pipes of residential areas, especially those from the water-purifier tank of large apartments, hydrogen sulfide should be the main target for follow-up treatment.

후발기업의 전략 모델에 대한 탐색적 연구 : LG전자의 사례를 중심으로 (The Strategic Model for the Late Mover: Evidence from the Defiance Case of LG Electronics)

  • 최규성;신호상
    • 유통과학연구
    • /
    • 제14권10호
    • /
    • pp.81-91
    • /
    • 2016
  • Purpose - This study proposes a strategic model for the late mover to effectively penetrate an industry that is dominated by a leading company. Thus, this study presents strategic implications for several late movers in overcoming the advantages of the leading company. Research design, data, and methodology - This study begins with a literature review followed by the formation of a strategic model that consists of: Repositioning, Utilization of Competence, Strategic Leadership, and Innovation. Specifically, this research analyzes LG Electronics (LG) as an example and investigates how LG infiltrates and grows in the water purifier market, overcoming the advantages of the powerful leading company. Results - The major steps taken by LG are summarized into four. First, LG studied the market, which had been conventionally treated as a single market. To penetrate the market, LG founded a new, special market segment. Subsequently, LG further segmented the market, executing a marketing strategy for each segment. Second, the unbending will of top managers was a key factor that addressed the challenge persistently. Third, even though LG was the late mover in the water purifier market, it had several technology competences such as compressor, refrigeration cycles, and algorithms. LG had profound knowledge in technology and used it effectively. Fourth, LG created a premium market through three innovative and distinguished factors such as the stainless water tank, sterilization service, and luxury design. Conclusions - This research draws four key findings from the example of the late mover in the water purifier industry: the reestablishment of a strategic position based on environmental change is an effective strategy for the late mover; strategic leadership is an important motive to generate late mover performance; and the late mover can utilize its existing knowledge and resources to overcome the first mover, such as presenting new added value compared to existing products as an effective catch-up strategy. Consequentially, through the study of performance determinants and the market penetration strategy of the late mover, this research has significance in providing basic material for companies trying to penetrate the market.

정수기 냉온수 탱크 원통형 드로잉 제품의 재질 변화에 따른 두께 변화에 관한 연구 (A study on the change of thickness according to material change of water purifier cold and hot water tank cylindrical drawing products)

  • 장은정;이춘규
    • Design & Manufacturing
    • /
    • 제15권3호
    • /
    • pp.13-18
    • /
    • 2021
  • In plate forming technology, cylindrical drawing process is widely used in industry due to technological development. In this study, we used stainless steel 3042B and stainless steel 304J1, which are the most commonly used materials in the production of cold and hot water tanks for water purifiers, among cylindrical drawing products. Under the same conditions, the thickness of the sidewall of the product formed by drawn experiment was studied. As a result of the experiment, the bottom thickness of stainless steel 304J1 was considered to be thick. It is judged that the defect rate can be reduced by changing the breaking phenomenon of the floor surface of the cold and hot water bottles to the material of stainless steel 304j1. Stainless steel 304 2B material shows a sharp change in thickness from punch corner R to sidewall position, while stainless steel 304J1 material showed a uniform change from punch corner R to sidewall position. Stainless steel 304J1 material is considered to improve the clamping of the product in the process of extracting the product after hand drawing. The appearance of stainless steel 3042B products is considered to produce more wrinkles in the flange, which exerts greater tensile force on the sidewall during molding, resulting in uneven sidewall thickness.

고용량 방사성옥소 치료 병실의 최대치 산출 (Maximum Value Calculation of High Dose Radioiodine Therapy Room)

  • 이경재;조현덕;고길만;박영재;이인원
    • 핵의학기술
    • /
    • 제14권1호
    • /
    • pp.28-34
    • /
    • 2010
  • 갑상선암 환자가 증가함에 따라 고용량 방사성옥소 치료환자 또한 적체되고 있는 추세이다. 따라서 현재 시설의 수용 능력을 고려하여 치료할 수 있는 병실의 최대치를 산출해 보고자 한다. 본원에 입원하는 고용량 방사성옥소 치료 환자의 방출 오 폐수량과 오 폐수의 방사능을 측정하고 고용량 방사성옥소 치료 병실에서 대기 중으로 방출하는 공기 중의 방사능 농도를 측정한다. 측정된 오 폐수의 방사능과 방출하는 공기 중의 농도가 교육과학기술부에서 고시하는 기준인 배수 중의 배출 관리 기준 30 Bq/L 및 배기 중의 배출관리기준 3 $Bq/m^3$을 만족할 때 치료 가능한 병실의 최대치를 계산한다. 가장 보수적인 수치로 계산하여 환자 1명을 치료할 경우 배출되는 오 폐수의 평균 방사능의 농도는 8 MBq/L였으며, 정화조에서 117일의 감쇠 시간을 거친 후의 평균 방사능의 농도는 29.5 Bq/L였다. 환자 2명을 치료할 경우 배출되는 오 폐수의 평균 방사능의 농도는 16 MBq/L였으며, 정화조에서 70일의 감쇠 시간을 거친 후의 평균 방사능의 농도는 29.7 Bq/L였다. 또한 같은 조건일 경우 치료 병실에서 RI 배기 filter를 통과하여 방출된 공기 중의 방사능 농도는 0.38 $Bq/m^3$였다. 수용 능력을 고려하여 치료할 수 있는 고용량 방사성옥소 치료 병실의 최대치를 산출하여 현재의 시설에 적용하고 병실 내 구조개선 등으로 2인실로 운영한다면 적체되어 있는 환자의 치료 대기 기간을 단축할 수 있으리라 사료된다.

  • PDF

대안학교의 생태중심주의 환경교육 실태 조사 (Survey on the Current Status of Ecocentric Environmental Education in Korean Alternative Schools)

  • 김영주;차정호;정철;이정호
    • 과학교육연구지
    • /
    • 제34권2호
    • /
    • pp.320-326
    • /
    • 2010
  • 이 연구에서는 대안학교의 생태중심주의적인 환경 교육의 실태를 조사하였다. 전국 42개 대안학교의 홈페이지와 학교 안내책자를 통해 각 학교의 교육목표와 교육과정, 그리고 환경 활동을 조사하였다. 또한 추가적인 정보를 조사하기 위하여 대안학교 교사를 대상으로 면담도 실시하였다. 연구 결과 생태주의를 지향하는 학교의 비율은 상대적으로 낮았지만 42개 대안학교 중 36개교(85.7%)의 교육 목표에 생태주의를 직 간접적으로 포함하고 있었다. 39개교에서 환경 관련 교과를 편성하고 있었는데, 이 과목들은 평균적으로 주당 3시간씩 운영되었다. 대안학교에서 가장 빈번하게 사용되는 환경 활동은 분리수거였고, 다음으로는 일회용품 사용 줄이기와 친환경 및 재활용 용품 사용하기였다. 자체 정화조 사용하기와 대체 에너지 사용하기도 환경 활동으로 실천되고 있었다. 이에 대한 교육적 함의를 논의하였다.

  • PDF