• Title/Summary/Keyword: Water-filling method

Search Result 152, Processing Time 0.058 seconds

Efficacy and Safety of Topical Application of Epidermal Growth Factor (EGF) for Korean Acne Patient (한국인 여드름 환자에서 표피성장인자가 함유된 외용제의 피부 적용에 대한 유효성 및 안전성 평가)

  • Suh, Joon Hyuk;Hyun, Moo Yeol;Jang, Seong Eum;Choi, Sun Young;Kim, Myeung Nam;Kim, Beom Joon
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.42 no.2
    • /
    • pp.111-118
    • /
    • 2016
  • Acne vulgaris is a chronic inflammatory condition characterized by comedo, papule, cyst, nodule and postinflammatory hyperpigmentation. Meanwhile, it is also induced by adverse event of drugs. Among them, acneiform folliculitis is a side effect of epidermal growth factor receptor (EGFR) inhibitor, which is an anticancer agent, and its incidence may occur in upward of 75 ~ 100% of cases. The main method of acne vulgaris treatment is oral antibiotics, retinoids, topical medication and so on. However, it is limitation that teratogenicity caused by retinoids and antibiotic resistance increased by using antibiotics. In this study, we aimed to evaluate the clinical efficacy and safety of topical recombinant human (rh) EGF in treating facial acne vulgaris. Twenty three Koreans (age: 10 ~ 29 years) with mild to moderate acne vulgar participated in the study and applied topical rhEGF cream (trouble control EGF) with 3 products (trouble control clarifying cleansing foam, trouble control all-clear filling toner, redroll calming moisture) on their face twice daily for four weeks. Several assessment methods were applied: Acne lesion counts score by investigator's global assessment, efficacy and satisfaction score by subjects. Skin sebum output level, hydration level and redness level were also measured at each visit. At the final visit, skin sebum level, transepidermal water loss, skin redness statistically decreased and acne lesions (comedone, papule) were statistically reduced. No severe side effects were observed during the study. In conclusion, topical rhEGF seems to be an effective and safe adjuvant treatment option for mild acne vulgaris.

Variation on Estimated Values of Radioactivity Concentration According to the Change of the Acquisition Time of SPECT/CT (SPECT/CT의 획득시간 증감에 따른 방사능농도 추정치의 변화)

  • Kim, Ji-Hyeon;Lee, Jooyoung;Son, Hyeon-Soo;Park, Hoon-Hee
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.25 no.2
    • /
    • pp.15-24
    • /
    • 2021
  • Purpose SPECT/CT was noted for its excellent correction method and qualitative functions based on fusion images in the early stages of dissemination, and interest in and utilization of quantitative functions has been increasing with the recent introduction of companion diagnostic therapy(Theranostics). Unlike PET/CT, various conditions like the type of collimator and detector rotation are a challenging factor for image acquisition and reconstruction methods at absolute quantification of SPECT/CT. Therefore, in this study, We want to find out the effect on the radioactivity concentration estimate by the increase or decrease of the total acquisition time according to the number of projections and the acquisition time per projection among SPECT/CT imaging conditions. Materials and Methods After filling the 9,293 ml cylindrical phantom with sterile water and diluting 99mTc 91.76 MBq, the standard image was taken with a total acquisition time of 600 sec (10 sec/frame × 120 frames, matrix size 128 × 128) and also volume sensitivity and the calibration factor was verified. Based on the standard image, the comparative images were obtained by increasing or decreasing the total acquisition time. namely 60 (-90%), 150 (-75%), 300 (-50%), 450 (-25%), 900 (+50%), and 1200 (+100%) sec. For each image detail, the acquisition time(sec/frame) per projection was set to 1.0, 2.5, 5.0, 7.5, 15.0 and 20.0 sec (fixed number of projections: 120 frame) and the number of projection images was set to 12, 30, 60, 90, 180 and 240 frames(fixed time per projection:10 sec). Based on the coefficients measured through the volume of interest in each acquired image, the percentage of variation about the contrast to noise ratio (CNR) was determined as a qualitative assessment, and the quantitative assessment was conducted through the percentage of variation of the radioactivity concentration estimate. At this time, the relationship between the radioactivity concentration estimate (cps/ml) and the actual radioactivity concentration (Bq/ml) was compared and analyzed using the recovery coefficient (RC_Recovery Coefficients) as an indicator. Results The results [CNR, radioactivity Concentration, RC] by the change in the number of projections for each increase or decrease rate (-90%, -75%, -50%, -25%, +50%, +100%) of total acquisition time are as follows. [-89.5%, +3.90%, 1.04] at -90%, [-77.9%, +2.71%, 1.03] at -75%, [-55.6%, +1.85%, 1.02] at -50%, [-33.6%, +1.37%, 1.01] at -25%, [-33.7%, +0.71%, 1.01] at +50%, [+93.2%, +0.32%, 1.00] at +100%. and also The results [CNR, radioactivity Concentration, RC] by the acquisition time change for each increase or decrease rate (-90%, -75%, -50%, -25%, +50%, +100%) of total acquisition time are as follows. [-89.3%, -3.55%, 0.96] at - 90%, [-73.4%, -0.17%, 1.00] at -75%, [-49.6%, -0.34%, 1.00] at -50%, [-24.9%, 0.03%, 1.00] at -25%, [+49.3%, -0.04%, 1.00] at +50%, [+99.0%, +0.11%, 1.00] at +100%. Conclusion In SPECT/CT, the total coefficient obtained according to the increase or decrease of the total acquisition time and the resulting image quality (CNR) showed a pattern that changed proportionally. On the other hand, quantitative evaluations through absolute quantification showed a change of less than 5% (-3.55 to +3.90%) under all experimental conditions, maintaining quantitative accuracy (RC 0.96 to 1.04). Considering the reduction of the total acquisition time rather than the increasing of the image acquiring time, The reduction in total acquisition time is applicable to quantitative analysis without significant loss and is judged to be clinically effective. This study shows that when increasing or decreasing of total acquisition time, changes in acquisition time per projection have fewer fluctuations that occur in qualitative and quantitative condition changes than the change in the number of projections under the same scanning time conditions.