• 제목/요약/키워드: Water-cooling

검색결과 2,260건 처리시간 0.034초

선박용 수냉식 디젤엔진의 개발 및 성능평가 (A Design for Water Cooling of a Marine Diesel Engine with Verification of Improvement)

  • 심한섭;전종오
    • 한국기계가공학회지
    • /
    • 제15권6호
    • /
    • pp.58-63
    • /
    • 2016
  • This paper presents a study of heat dissipation away from the fuel combustion of a marine diesel engine. These engines are operated for long periods under high load conditions: so cooling systems are necessary for radiation and control of the high temperature levels. In the study, each component of the water cooling system was developed to achieve improvements in cooling and safety. Heat transfer considerations and arrangement design for the components were important and an intercooler and exhaust manifold incorporated. An optimization of the cooling water's flow path was achieved subject to the need for convenient maintenance. The 750Ps marine diesel engine was used for performance testing of the cooling system. The test results showed adequate cooling performance improvement.

증발냉각에 의한 공랭 응축기의 성능향상 가능성에 관한 연구 (Cooling Enhancement Potential of an Air-Cooled Condenser by Evaporative Cooling)

  • 이대영;백영진;김영일
    • 설비공학논문집
    • /
    • 제16권3호
    • /
    • pp.203-210
    • /
    • 2004
  • This paper describes the potential advantages in applying evaporative cooling to air-cooled condensers. The cooling characteristics of an air-cooled condenser with its surface fully covered with thin water film are investigated and compared with that of an air-cooled condenser with usual dry surface. By applying the evaporative cooling, the cooling performance of the condenser is shown to improve enormously. When the outdoor air is 35$^{\circ}C$ and 40% in relative humidity, the condensing temperature of the refrigerant is decreased by 2$0^{\circ}C$. Even when the incoming air is fully saturated with water vapor, the evaporation from the wet surface occurs to cause a decrease in the condensing temperature by 1$0^{\circ}C$. The main reason for this improvement is assessed as the addition of an efficient cooling mechanism which is the water evaporation resulting in latent heat absorption.

베어관을 이용한 30RT급 하이브리드 밀폐형 냉각탑의 성능특성에 관한 실험적 연구 (An Experimental Study on Performance Characteristic of 30RT Closed-Type Hybrid Cooling Tower using Bare Tube)

  • 전철호;이호생;문춘근;김재돌;윤정인
    • 한국마린엔지니어링학회:학술대회논문집
    • /
    • 한국마린엔지니어링학회 2005년도 전기학술대회논문집
    • /
    • pp.1096-1101
    • /
    • 2005
  • In this study, the experiment of thermal performance about closed-type hybrid cooling tower was conducted. A closed type cooling tower is a device similar to a general cooling tower, but with cooling tower replaced by a heat exchanger. The test section for this experiment has the process that the cooling water flows from top part of heat exchanger to bottom side in the inner side of tube, and spray water flows gravitational direction in the outer side of it. Air contacts of tube outer side are counterflow. The heat transfer pipe used in this experiment is a bare type tube having an outside diameter of 15.88mm. In this experiment, heat performances of the cooling tower are calculated such as overall heat transfer coefficient of between the process fluid and air, cooing capacity and pressure drop.

  • PDF

순간냉각식 정수기 냉수조의 설계변수에 따른 성능 특성에 관한 해석적 연구 (Analytical Study on the Performance Characteristics of an Instant Cooling Type Water Purifier with the Design Parameters of the Cooling Tank)

  • 전용석;박홍희;이주성;김용찬
    • 설비공학논문집
    • /
    • 제24권7호
    • /
    • pp.545-552
    • /
    • 2012
  • The objective of this study is to analyze the effect on the energy consumption of an instant cooling type water purifier by the design parameters of the cooling tank. Initially, the simulation program was developed and verified. The simulation results showed that the energy consumption was reduced by replacing the shape of the cooling tank from a rectangular to a cube, increasing the evaporator length, decreasing the volume of the cooling tank, and increasing the performance of the insulator. The order of the effect magnitude on the energy consumption was as follows; volume of the cooling tank, conductivity and thickness of the insulator, shape of the cooling tank, length of the evaporator, and length of the water tube.

Performance Analysis of Water-Water Heat Pump System of 100 kW Scale for Cooling Agricultural Facilities

  • Kang, Youn Ku;Ryou, Young Sun;Jang, Jae Kyung;Kim, Young Hwa;Kim, Jong Goo;Kang, Geum Chun
    • Journal of Biosystems Engineering
    • /
    • 제39권1호
    • /
    • pp.34-38
    • /
    • 2014
  • Purpose: In this study, the performance of cooling system with the water-water heat pump system of 100kW scale made for cooling agricultural facilities, especially for horticultural facilities, was analyzed. It was intended to suggest performance criteria and performance improvement for the effective cooling system. Methods: The measuring instruments consisted of two flow meters, a power meter and thermocouples. An ultrasonic and a magnetic flow meter measured the flow rate of the water, which was equivalent to heat transfer fluid. The power meter measured electric power in kW consumed by the heat pump system. T-type thermocouples measured the temperature of each part of the heat pump system. All of measuring instruments were connected to the recorder to store all the data. Results: When the water temperature supplied into the evaporator of the heat pump system was over $20^{\circ}C$, the cooling Coefficient Of Performance(COP) of the system was higher than 3.0. As the water temperature supplied into the evaporator, gradually, lowered, the cooling COP, also, decreased, linearly. Especially, when the water temperature supplied into the evaporator was lower than $15^{\circ}C$, the cooling COP was lower below 2.5. Conclusions: In order to maintain the cooling COP higher than 3.0, we suggest that the water temperature supplied into evaporator from the thermal storage tank should be maintained above $20^{\circ}C$. Also, stratification in the thermal storage tank should be formed well and the circulating pumps and the pipe lines should be arranged in order for the relative low-temperature water to be stored in the lower part of the thermal storage tank.

500MW급 화력 발전기 냉각수 온도에 따른 고정자 권선 절연재의 흡습 특성에 관한 실험적 연구 (An Experimental Study on Water Absorbtion Characteristics of Generator Stator Bar Insulation by Cooling Water Temperature in 500MW Capacity Power Plant)

  • 배용채;김희수;이두영;이욱륜
    • 전기학회논문지
    • /
    • 제57권8호
    • /
    • pp.1392-1397
    • /
    • 2008
  • The mechanical integrity of generator stator windings is one of the critical point because the electric power is generated and conducted to power system through these windings. De-mineralized water is used to cool stator bars during the normal operation of generator in large power plants because the water cooled method has highest cooling efficient. Water absorption of bar insulation is progressed by several causes such as generation of water leak path by corrosion, delamination of insulation by vibration, and inadequate water treatment, etc.. Reliable water absorption diagnostics of generator stator bar is important to ensure the availability of power plant and to reduce maintenance cost by generator accident. It is described that the water absorption characteristics for generator stator bar insulation used in 500MW capacity standard fossil power plant by cooling water temperature. It is verified that the management of stator cooling water temperature is one of the important factors to decrease water absorption rate of generator stator bars.

열적외선 자료에 의한 고리 원자력발전소의 냉각수 확산에 대한 연구 (Dispersion Pattern of CoolingWater of Kori Atomic Power Station Using Thermal Infrared Data)

  • 姜必鍾;智光薰
    • 대한원격탐사학회지
    • /
    • 제3권2호
    • /
    • pp.81-87
    • /
    • 1987
  • The study was to analysis the dispersion of the cooling water of Kori atomic power station using thermal infrared data. The dispersion pattern of the cooling water analysis clearly on the LANDSAT TM band 6. It was changed due to tidal current, that is, the cooling water disperses north-eastern direction during the low tide and southweatern direction during the high tide. The relative temperature distribution was mapped through the density slicing method on the images.

비상시 열원중단에 따른 데이터센터의 냉각시스템 열성능 평가에 관한 사례연구 (A Study on Thermal Analysis for a Data Center Cooling System under Fault Conditions at a Chilled Water Plant)

  • 조진균;강호석
    • 설비공학논문집
    • /
    • 제28권5호
    • /
    • pp.178-185
    • /
    • 2016
  • This study describes the analysis of a 20 MW chilled water plant used for the IT cooling of a recently constructed data center in Korea. The CFD model was developed with the aim of evaluating the impact of problems such as chiller failure on the water and air temperatures in the cooling system. The numerical model includes the chilled water hydraulic network and individual water-to-air CRAC units. The coupling between the IT server room air temperature levels and the cooling plant has enabled a full assessment of the cooling system design in response to system fault conditions to be performed. The paper examines an emergency situation involving the failure of the cooling plant, and shows how the inherent thermal inertia of the system along with additional inertia achieved through buffer systems allowed a suitable design to be achieved.

진공 예냉장치 내에서의 야채류의 온도 변화 특성에 관한 연구 (A study on the characteristic of vegetables temperature in the pre-cooling vacuum unit)

  • 원종호;박상균;윤석훈;오철
    • 한국항해항만학회지
    • /
    • 제31권10호
    • /
    • pp.879-884
    • /
    • 2007
  • 진공예냉장치에서 상대습도변화 및 냉각온도변화에 따른 야채류의 온도변화에 대하여 고찰한 논문이다. 실험장치는 진공챔버, 이젝트펌프, 냉동기장치, 계측장치 및 냉각수 계통으로 구성되어 있다. 실험결과 야채류의 냉각속도는 야채류의 함수율에 크게 의존하고 있으며, 함수율이 높은 야채가 낮은 야채에 비하여 냉각속도가 증가하는 것을 알 수 있다.

지역의 경관을 고려한 도막방수재의 색채별 사계절 차열 및 축열 성능에 관한 연구 (A Study on the Four-Season Cooling Performance by Color of Water Proofing Membrane Materials Considering the View of Area)

  • 고진수;김병윤
    • 한국농촌건축학회논문집
    • /
    • 제17권2호
    • /
    • pp.9-16
    • /
    • 2015
  • This study comparatively analyzed thermal characteristics of the green color, which is currently used the most, and other various colors of a rooftop urethane water proofing sheet. This study also analyzed the cooling performance by color of the water proofing sheet that fused cooling paints, and presented the effective water proofing sheet color for building energy savings. The experimental results are as follows: (1) The value of L (brightness) diminished, and brilliance also became lower from the white color to the black color, and thus, it was confirmed that relatively more heat was absorbed. In a and b chromaticity, which is the color attribute that ignores brightness, no special relationship was identified. (2) Considering that the cooling performance effect is bigger in summer than winter, due to heat reflection, the white water proofing sheet is more effective in building energy savings than the green water proofing sheet that is currently used the most. (3) The water proofing sheet's color has an impact more on cooling performance than the color of the background side of a structure on which water proofing sheet is installed. The experiment object of gray, of which background side is similar to cement mortar, was lower by $5.7^{\circ}C$ than the white background side.