• 제목/요약/키워드: Water-cooling

검색결과 2,260건 처리시간 0.03초

얼음과 냉각수를 이용한 콘크리트의 프리쿨링에 관한 연구 (Study on Precooling of Concrete Using Ice and Cooling Water)

  • 정철헌;박장호;이순환
    • 콘크리트학회논문집
    • /
    • 제12권3호
    • /
    • pp.95-102
    • /
    • 2000
  • Crack control due to temperature is an important factor for the mass concrete structure. Pre-cooling is the effective system to reduce the highest temperature of mass concrete. In this study, for pre-cooling, cooling water, cooling water with ics flake are used. The results of a series of experimental studies indicate that the changes in properties of fresh concrete after cooling are of low degree, and compressive strength of concrete is changed very little by cooling. The adiabatic temperature rise is also measured with pre-cooling concrete specimens. It is shown that hydration heat characteristics of cement and concrete were largely affected by pre-cooling.

가정용 흡수식 냉온수기용 냉각탑의 성능특성 (Performance Characteristics of Cooling Tower on Small Absorption Chiller)

  • ;김은필;정석권;민경현;김재돌;윤정인
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제28권7호
    • /
    • pp.1145-1151
    • /
    • 2004
  • The experiment of thermal performance about cross flow type cooling tower was conducted in this study. Generally the ambient air condition can affect the thermal performance of cooling tower to improve or not. However it is hard to control the cooling water temperature that we want under bad air condition or during rainy season. In this paper, the effect of variables, which the ambient air have. especially wet-bulb temperature, are experimentally investigated for controlling the cooling water temperature more successfully. The result is that there is appropriate air flow rate in respective air condition to preserve the cooling performance in the cooling tower and the maximum air flow rate can't overcome the approach under bad air condition.

주행하는 고온 강재의 상하부 동시 냉각 과정 수치해석 (Numerical Analysis of Simultaneous Cooling Process of Upper and Lower Side of Running Hot Steel Strip)

  • 권면재;박일석
    • 대한기계학회논문집B
    • /
    • 제38권12호
    • /
    • pp.1051-1056
    • /
    • 2014
  • 열간 압연을 거친 $800^{\circ}C$ 이상의 고온 철강 판재는 일반적으로 다중 봉상 수분류(multiple circular water jets)에 의해서 급속 냉각된다. 이 과정은 소재의 온도가 냉각수의 끓는점보다 훨씬 높기 때문에 소재 표면과 냉각수 사이에 막비등 열전달 현상이 발생하며 소재 표면에 매우 얇은 증기층이 형성되며, 이 증기층은 소재와 냉각수의 열교환을 방해하는 중요한 열저항으로 작용한다. 본 문제에는 비등 열전달 이외에도 소재 표면에 쌓이는 체류수의 자유표면 유동, 소재의 고속 주행 등 복잡한 물리현상들이 복합적으로 작용하고 있다. 본 논문에서는 이 모든 물리현상들을 동시에 고려할 수 있는 해석 절차를 적용하여 일정한 속도로 주행하는 고온 철강 판재의 상하부 동시 냉각 과정을 3 차원 수치해석 하였으며, 소재 상부 및 하부 면의 냉각 특성을 비교하였다.

회전형 마그네트론 음극의 냉각수 유동 및 열전달 해석 (Flow and Heat Transfer Analysis of Cooling Water in a Rotating Magnetron Cathode)

  • 주정훈
    • 한국표면공학회지
    • /
    • 제52권3호
    • /
    • pp.171-179
    • /
    • 2019
  • We have developed a numerical model to analyze flow dynamics and heat transfer characteristics of the cooling water in a circular rotating magnetron cathode by a moving boundary grid method realized in a commercial multiphysics package, CFD-ACE+. The numerical model is composed of a target, dual mass rotating cathode and cooling water connections. When the inlet and outlet of the cooling water are offset by the same distance from the rotation axis, the temperature at the center is higher by $50^{\circ}C$ at maximum. At 5 mm away from the target surface, the temperature profile showed typical center high characteristic. At heat input of 30 kW, the maximum temperature change of the cooling water hits $6^{\circ}C$ within 0.5 sec under 60 rpm. With a cooling water configuration of center in/edge out, the temperature of the center region of the target gets lowered. Within 100 seconds of plasma operation time, the cooling water temperature keeps getting higher.

물-물 수온차 히트펌프 시스템의 원수온도에 따른 성능 특성 분석 (Analysis on Cooling and Heating Performance of Water-to-Water Heat Pump System for Water Source Temperature)

  • 박태진;조용;박진훈
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2010년도 춘계학술대회 초록집
    • /
    • pp.169.2-169.2
    • /
    • 2010
  • The research assesses the performance of the water-to-water heat pump system installed in Cheongju water treatment plant for cooling and heating ventilation. In summer season monthly averaged COP is ranged from 3.85 to 4.56 according to the water source temperature, and the performance is increased as the raw water temperature is dropped. While, heating performance is increased for the high temperature water source, and the monthly averaged COP is changed from 2.92 to 3.82. The correlation of the water source temperature and the heat pump performance shows a linear tendency by the simple regression of average data. In heating, the COP of heat pump system linearly rises according to the water source temperature. In comparison, the COP in cooling linearly reduces as the raw water temperature is raised. The goodness of fit at the simple regression shows the coefficient of determination 82% in cooling, 46% in heating. The electric cost of water-to-water heat pump is reduced by 40% compared to that of air source heat pump.

  • PDF

농업용(農業用) 소형(小型)디젤기관(機關) 냉각(冷却)시스템의 개선(改善)에 관(關)한 연구(硏究) (Improvement of Water Cooling System of a Small Diesel Engine)

  • 김성래;명병수
    • Journal of Biosystems Engineering
    • /
    • 제18권1호
    • /
    • pp.3-14
    • /
    • 1993
  • This study was conducted to obtain basic data which affected engine performance of the power tiller being widely used in the rural area. Among the various factors being influenced engine performance, factors of radiator, of capacity of cooling water, and of efficiency of cooling fan were considered as the major factors in this study. Because diesel engine being used to power tiller are scarce of cooling water, it is over-heated in time of rated power. Therefore, a experiment was performed to determine the capacity of cooling water of engine with circuit system of cooling water adhered.

  • PDF

건물냉방시스템에 해양심층수 적용의 경제성 분석 (Economic Feasibility Assessment of a Deep Sea Water District Cooling System)

  • 김삼열;조수
    • 한국태양에너지학회 논문집
    • /
    • 제29권2호
    • /
    • pp.14-21
    • /
    • 2009
  • Recently, alternative energy resources have emerged considerably due to the high oil prices and environment problems. Deep sea water that is one of the natural energy sources can be one of the attractive solutions to reduce the environment problems, and there are already a few examples in some developed countries. In this study, cooling system of deep sea water using heat exchangers of two hotels, located in near Haeundae Bay in Busan, have been analyzed on the quantity of electricity and gas use comparison between existing cooling system and deep seawater cooling system by using E-Quest simulation program. The results of the study showed that the Hotel A approximately saves 370 millions won per year, and the Hotel B saves 248 millions won per year. It means that the cooling system by using deep sea water has great worth to reduce the ratio of fuel sources.

로켓엔진 고공환경 모사용 디퓨져의 냉각 채널 열 해석 (Thermal Analysis of Exhaust Diffuser Cooling Channels for High Altitude Test of Rocket Engine)

  • 조기주;김용욱;강선일;오승협
    • 항공우주기술
    • /
    • 제9권2호
    • /
    • pp.193-197
    • /
    • 2010
  • 로켓엔진 고공 환경 모사용 디퓨져에는 연소가스의 고열로부터 디퓨져를 보호하기 위해 물을 이용한 냉각시스템이 사용되며 냉각수의 유량 및 압력은 냉각 채널 내부에서 냉각수의 비등이 발생하지 않도록 결정된다. 따라서 냉각수 유량의 변화에 따른 냉각 채널 벽면의 최고온도 예측은 냉각시스템의 운용 압력을 결정하는데 주요한 변수가 된다. 본 연구에서는 열평형 이론에 근거하여 유량 변화에 따른 채널 벽면의 최고온도를 예측하는 방법을 기술하였다.

전자제어 장치를 이용한 용광로 냉각관 누수 지동 감지장치 개발에 관한 연구 (A Study on Automatic Sensing Device for Water Leakage of Cooling Pipe at Blast Furnace by Use The Electronic System)

  • 강창수;강기성
    • 전자공학회논문지 IE
    • /
    • 제46권4호
    • /
    • pp.25-30
    • /
    • 2009
  • 용광로는 외피 부분에 내부 내화물의 온도를 낮추기 위하여 냉각수를 공급하는 냉각판 또는 스테이브를 사용하고 있다. 주변 조업 조건의 열악으로 냉각수를 공급하는 배관의 부식으로 냉각수가 내화물에 침투하여 내화물의 수명을 떨어뜨리고, 노황을 악화시키는 원인이 되고 있다. 이에 본 연구는 용광로 냉각설비장치에 이상 현상이 발생하였을 때 위치를 정확히 확인함에 따라 신속하게 누수된 부위를 파악하여 대처할 수 있는 기능을 갖춘 냉각관 누수 자동감지장치를 개발하였다. 주된 연구는 전자제어 장치인 마이크로프로세서를 응용한 전자변 제어장치를 이용하여 냉각설비의 파손으로 발생되는 누수현상으로 인한 고열과 분진 일산화탄소 등의 산출로 작업환경의 재해를 자동방지 하고자 하였으며, 작업환경이 친환경적이며 작업의 가치를 재창출할 수 있는 방법들이 연구되고 있다. 용광로 분위기의 일산화탄소 자동 감지장치와 그에 따른 출력신호를 자동 전송하는 무선중계기 장치를 개발함으로 용광로 냉각설비 장치의 분위기 작업환경을 수동방식에서 무인자동화방식으로 개선하였다.

냉각된 복사천장패널의 열전달 특성에 관한 연구 (A Study on the Heat Transfer Characteristics of the Radiant Chilled Ceiling Panel for Space Cooling)

  • 이태원;황인주
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 춘계학술대회논문집D
    • /
    • pp.164-169
    • /
    • 2001
  • There is a chilled ceiling panel which carries out the air conditioning by radiation and convection between the room and cold ceiling panel surface. In order to verify heat transfer characteristics between them in cooling system with radiant chilled ceiling panel, analytical and experimental studies were performed for various design and operating parameters such as tube space and diameter, inlet water temperature, mass flow rate, cooling load, and so on. In this study, we found that the tube space and inlet water temperature were more important elements than the tube diameter and water flow rate for the performance of radiant chilled ceiling panel. The cooling capacity of the radiant chilled ceiling panel had the maximum value of $65W/m^{2}$ because the highest cooling capacity was limited by the condensation on the panel surface. The results of comparison between numerical analysis and experiment showed a resonable agreement qualitatively, especially for low cooling capacity.

  • PDF