A Study on the Diagnosis for Water Absorption of Generator Stator Windings (발전기 고정자 권선의 흡습 진단)

  • Bae Y.C.;Kim H.S.;Lee D.Y.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.297-298
    • /
    • 2006
  • Water leak for the water-cooled generator stator windings affects seriously the availability and the reliability of power plants. Generally, water absorption test is conducted in the power plant during outage in order to confirm if leak part is in the bars or not. In this paper, it is described that the capacitance of winding bars is measured by using the developed water absorption instrument system and the water absorption of winding bars is evaluated by using the stochastic methods. The good results by proposed diagnosis technique can be got. It is expected that the reliability of diagnosis for water absorption is increased if the proposed methods are applied to evaluate the water absorption of stator winding bars.

  • PDF

Test Result Analysis of a 1MW HTS Motor for Industry Application

  • Baik, S.K.;Kwon, Y.K.;Kim, H.M.;Lee, E.Y.;Kim, Y.C.;Park, H.J.;Kwon, W.S.;Park, G.S.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.11 no.2
    • /
    • pp.33-36
    • /
    • 2009
  • A 1 MW class HTS (High-Temperature Superconducting) synchronous motor has been developed. This motor is aimed to be utilized for industrial application such as large motors operating in large plants. The HTS field coil of the developed motor is cooled by way of neon thermo siphonmechanism and the stator (armature) coil is cooled by water through hollow copper conductor. This paper also describes evaluation of some electrical parameters from performance test results of our motor, which was conducted at steady state in generator mode and motor mode. Open and short circuit tests were conducted in generator mode while a 1.1 MW rated induction machine was rotating the HTS machine. Electrical parameters such as mutual inductance and synchronous inductance are deduced from these tests. Load test was done upto rating torque during motor mode and efficiency was measured at each load torque.

Health prognostics of stator Windings in Water-Cooled Generator using Fick's second law (Fick's second law 를 이용한 수냉식 발전기 고정자 권선의 건전성 예지)

  • Youn, Byeng D.;Jang, Beom-Chan;Kim, Hee-Soo;Bae, Yong-Chae
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2014.10a
    • /
    • pp.533-538
    • /
    • 2014
  • Power generator is one of the most important component of electricity generation system to convert mechanical energy to electrical energy. I t designed robustly to maintain high system reliability during operation time. But unexpected failure of the power generator could happen and it cause huge amount of economic and social loss. To keep it from unexpected failure, health prognostics should be carried out In this research, We developed a health prognostic method of stator windings in power generator with statistical data analysis and degradation modeling against water absorption. We divided whole 42 windings into two groups, absorption suspected group and normal group. We built a degradation model of absorption suspected winding using Fick's second law to predict upcoming absorption data. Through the analysis of data of normal group, we could figure out the distribution of data of normal windings. After that, we can properly predict absorption data of normal windings. With data prediction of two groups, we derived upcoming Directional Mahalanobis Distance (DMD) of absorption suspected winding and time vs DMD curve. Finally we drew the probability distribution of Remaining Useful Life of absorption suspected windings.

  • PDF

Thermal Analysis and Optimum Design of Water-Cooled, Series-Flow Type, Double-Effect Absorption Heat Pump (수냉형 직렬방식 2중효용 흡수식 냉방기의 열해석과 최적 설계)

  • Oh, M.D.;Kim, Y.L.;Kim, S.C.;Kim, Y.I.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.4 no.4
    • /
    • pp.332-341
    • /
    • 1992
  • An absorption heat pump cycle has been modeled and simulated to analyze the system performance of water-cooled, series-flow, double-effect absorption heat pump, which can be applied to a direct gas fired cooling system with the medium range of cooling capacity (15RT level). Effect of absorption cooling system parameters, such as concentration difference, inlet temperature of cooling water, 1st generator temperature, leaving temperature differences of condenser and evaporator and efficiency of solution heat exchanger, has been investigated in the view of system cooling performance.

  • PDF

Electrical characteristics of class-F groundwall insulation tapes for stator windings (고정자 권선용 F종 주절연 테이프의 전기적 특성)

  • Kim, Tae-Hee;Kang, Myung-Guk;Lee, Jai-Kwun;Son, Sam-Young
    • Proceedings of the KIEE Conference
    • /
    • 2004.07c
    • /
    • pp.1679-1681
    • /
    • 2004
  • Class-F and B resin-rich type insulating tapes are generally used for the ground wall insulations of respective air-cooled and water-cooled stator windings in larger turbine generators. In this paper, their electrical properties coupled with aging times in higher temperature than designed one in normal condition were experimentally investigated and the results of two comparative tests were presented on the existing class-F resin-rich type tape and a developed one after curing. The resin-rich tapes currently used arc composed of six and a half 3-layer sheets that arc structured with mica paper, the top and bottom supports of it respectively, and the epoxy resin to bind them tightly. The results for breakdown voltage and strength on the cured specimens were presented, which were composed of the unaged, the aged accelerated for one, two, and three thousand hours at 180 $^{\circ}C$. The surface and volume resistivities on them were measured and the results are also presented to make a comparative test for the initial electrical characteristics.

  • PDF

A Study on the Water Absorption Test of Generator Stator Windings Using Probability Distributions (여러 가지 확률분포를 이용한 발전기 고정자 권선의 흡습 시험에 관한 연구)

  • Kim, Hee-Soo;Bae, Y.C.;Kim, Hee-Jeong;Na, Myung-Hwan
    • The Korean Journal of Applied Statistics
    • /
    • v.22 no.5
    • /
    • pp.961-969
    • /
    • 2009
  • Water absorption in water-cooled generator stator windings can cause serious accidents such as insulation breakdown and it brings a generator to the unexpected sudden outage. Accordingly, it is important to diagnose the water absorption of them in the effective operation of power plant. Especially, the capacitance value which is measured for diagnosis is very small so the special diagnosis methods like stochastic theory are needed. KEPRI developed the water absorption test equipment and diagnosis technology for them. In this paper we propose that water absorption test of generator stator windings using probability distributions. The proposed diagnosis technology is applied to the real system and the results of water absorption test for stator windings are agreed to them of water leak test.

Analysis of On-Line Partial Discharge in Air-Coolded Gas Turbine Generator (공랭식 가스터빈 발전기의 운전중 부분방전 분석)

  • Lee, Eun-Chun;Kong, Tae-Sik;Kim, Jae-Chul;Kim, Hee-Dong
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.28 no.7
    • /
    • pp.41-47
    • /
    • 2014
  • The on-line partial discharge (PD) in stator windings of air-cooled gas turbine (GT) generator (119.2MVA, 13.8kV) is measured and analyzed in this paper. This generator was designed by global vacuum pressure impregnation (VPI). The generator failed two times at top bar (16T) of phase B in the stator slot. Six epoxy-mica capacitors were installed in three phases of GT generator. On-line PD test was performed on GT generator using turbine generator analyzer (TGA). TGA showed that the normalized quantity number (NQN) and the PD magnitude($Q_m$) were high in phase B. Internal discharges were generated in phases A, B and C. The trend analysis of NQN and $Q_m$ value are obtained in order to monitor the insulation condition in GT generator stator windings. Phases A and C were in good condition. But phase B had deteriorated significantly

Magnetic Flux Leakage (MFL) based Defect Characterization of Steam Generator Tubes using Artificial Neural Networks

  • Daniel, Jackson;Abudhahir, A.;Paulin, J. Janet
    • Journal of Magnetics
    • /
    • v.22 no.1
    • /
    • pp.34-42
    • /
    • 2017
  • Material defects in the Steam Generator Tubes (SGT) of sodium cooled fast breeder reactor (PFBR) can lead to leakage of water into sodium. The water and sodium reaction will lead to major accidents. Therefore, the examination of steam generator tubes for the early detection of defects is an important requirement for safety and economic considerations. In this work, the Magnetic Flux Leakage (MFL) based Non Destructive Testing (NDT) technique is used to perform the defect detection process. The rectangular notch defects on the outer surface of steam generator tubes are modeled using COMSOL multiphysics 4.3a software. The obtained MFL images are de-noised to improve the integrity of flaw related information. Grey Level Co-occurrence Matrix (GLCM) features are extracted from MFL images and taken as input parameter to train the neural network. A comparative study on characterization have been carried out using feed-forward back propagation (FFBP) and cascade-forward back propagation (CFBP) algorithms. The results of both algorithms are evaluated with Mean Square Error (MSE) as a prediction performance measure. The average percentage error for length, depth and width are also computed. The result shows that the feed-forward back propagation network model performs better in characterizing the defects.

Cycle Analysis of Air-Cooled Double-Effect Absorption Cooling System Using H2O/LiBr+HO(CH2)3OH (H2O/LiBr+HO(CH2)3OH계 공냉형 이중효용 흡수식 냉방시스템의 사이클 해석)

  • Kwon, Oh-Kyung;Moon, Choon-Geun;Yoon, Jung-In
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.23 no.2
    • /
    • pp.272-280
    • /
    • 1999
  • A cycle analysis was achieved to predict the characteristics by comprehensive modeling and simulation of an air-cooled, double-effect absorption system using a new $H_2O/LiBr+HO(CH_2)_3OH$ solution. The simulation results showed that the new working fluid may provide the crystallization limit 8% higher than the conventional $H_2O/LiBr$ solution. With a crystallization margin of 3wt%(weight%), the optimal solution distribution ratio was found in the range of 36 to 40%. Variation of cooling air Inlet temperature has a sensitive effect on the cooling COP and corrosion problem. The simulation of heat exchangers with UA value revealed that the absorber and the evaporator are relatively important for an air-cooled system compared with the condenser and the low temperature generator. The effect of cooling air flow rate, circulation weak solution flow rate and chilled water inlet temperature were also examined. The new working fluid may provide the COP approximately 5% higher than the conventional $H_2O/LiBr$ solution.

Subscale high altitude simulation test using solid propellant gas generator (고체추진제 가스발생기를 이용한 축소형 고공환경모사 시험)

  • Kim, Yong-Wook;Lee, Jung-Ho;Yu, Byung-Il;Cho, Sang-Yeon;Oh, Seung-Hyub
    • Aerospace Engineering and Technology
    • /
    • v.7 no.1
    • /
    • pp.136-141
    • /
    • 2008
  • Cylindrical supersonic exhaust diffuser, which utilizes the momentum of high temperature gas exhausted from nozzle, provides simple methods for obtaining stable and low pressure around the propulsion system. Hot zone on which exhausted gas from nozzle exit impinges directly should be cooled to avoid melting of diffuser. This paper describes method and result of subscale high altitude simulation test with water cooling. Subscale gas generator with solid propellant was used for hot gas source and tap water for coolant.

  • PDF