• Title/Summary/Keyword: Water-Fluidized-Bed

Search Result 137, Processing Time 0.02 seconds

Fluidized Bed Drying Effect on the Aerogel Powder Synthesis

  • Hong, Seong-Hoon;Lee, Dong-Kyu;Oh, Chang-Sup;Kim, Yong-Ha
    • Journal of Energy Engineering
    • /
    • v.21 no.1
    • /
    • pp.43-46
    • /
    • 2012
  • A fluidized bed drying approach was utilized to the synthesis of water glass based silica aerogel powders. The effects of the fluidized bed drying conditions such as the superficial velocity and temperature of hot air and bead size as well as bead/wet-gel ratio, on the physical properties such as tapping density and productivity of the aerogel powders were systematically investigated. The experimental results showed that the amount of beads mixed with wet-gels in the fluidized bed column has the most profound impact on the fluidization efficiency, greatly enhancing the yield of the aerogel powders up to 98% with a proper bead/wet-gel weight ratio as compared to 72% without using beads. No significant change was observed in the tapping density over a wide range of the fluidized drying condition. Consequently the fluidized bed drying approach shows a good promise as an alternative route for the large-scale production of the aerogel powders.

A Study on the Heat Recovery Performance of Water Fludized-Bed Heat Exchanger (물유동층 열교환기의 열회수성능 연구)

  • 김한덕;박상일;이세균
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.15 no.8
    • /
    • pp.690-696
    • /
    • 2003
  • This paper presents the heat recovery performance of water fluidized-bed heat exchanger. Temperature and humidity ratio of waste gas are considered as important parameters in this study. Therefore, the heat recovery rate through water fluidized-bed heat exchanger for exhaust gases with various temperatures and humidity ratios can be estimated from the results of this study. Mass flow ratio (the ratio of mass flow rate of water to that of gas) and temperature of inlet water are also considered as important operating variables. Increase of heat recovery rate can be obtained through either high mass flow ratio or low temperature of inlet water with resultant low recovered temperature. The heat recovery performance with the mass flow ratio of about up to 10 has been investigated. The effect of number of stages of water fluidized-bed on the heat recovery performance has been also examined in this study.

An Experimental Study on Heat Transfer Performance of Fluidized Bed Heat Exchanger for Heat Recovery from Multi-Heat Sources (다중열원 열회수형 유동층 열교환기의 전열성능에 대한 실험적 연구)

  • Park, Sang-Il;Ko, Chang-Bok;Lee, Young-Soo
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.29 no.2
    • /
    • pp.57-62
    • /
    • 2017
  • The heat transfer performance of a multi-heat-source fluidized bed heat exchanger was analyzed. The fluidized bed heat exchanger examined in this study can simultaneously recover the waste heat from gas, water vapor, and hot water. The effects of waste water flow rate, gas flow rate, and cooling water flow rate were examined to find their experimental correlations with the heat transfer coefficient. A computer program using the correlations was developed in this study to predict the thermal performance of the fluidized bed heat exchanger. The calculated heat transfer rates of gas, water vapor, waste water, and cooling water were compared with the measured values. It was found that the error of the calculated values was less than 12%.

Water Treatment of Seawater Recirculating Aquaculture System by Using Three Phase Fluidized Bed Reactor (삼상 유동층 반응조를 이용한 해수 순환 여과 시설의 수처리)

  • Lee, Byung-Hun;Choi, Hyeok;Ryu, Jong-Soo
    • Journal of Aquaculture
    • /
    • v.13 no.2
    • /
    • pp.137-145
    • /
    • 2000
  • Capacity of water treatment of the three phase fluidized bed reactor as a biofilter in the seawater recirculating system was evaluated. The water treatment system consists of fluidized bed reactor for ammonia removal, cartridge filter for solid removal and ozone contactor for disinfection. Mean concentration of water quality parameters: COD, TAN, $NO_2$-N, $NO_3$-N, SS and alkalinity were 9.0, 0.22, 0.05, 20.0, 9.5 and 70.0 mg/l, respectively; the relevant values were 7.6 for pH and 3.64 NTU for turbidity. These indicate the maintenance of good water quality by the treatment system. The influent TAN loading rate in to the fluidized bed reactor ranged from 4.3 to 32.9 g/$m^3$/day, and averaged to 20 g/$m^3$/day. TAN removal efficiency of each phase of the fluidized bed reactor was 47-60%, indicating the effective ammonia removal. During operation the effluent of fluidized bed reactors also maintained the unionized ammonia nitrogen level below 0.002 mg/l.

  • PDF

Improved Flowability and Wettability of Whey Protein-Fortified Skim Milk Powder via Fluidized Bed Agglomeration

  • Seo, Chan Won
    • Food Science of Animal Resources
    • /
    • v.42 no.6
    • /
    • pp.915-927
    • /
    • 2022
  • Recently, protein-fortified milk powders are being widely consumed in Korea to prevent sarcopenia, and the demand for high-protein food powders is continuously increasing in the Korean market. However, spray-dried milk proteins have poor flowability and wettability owing to their fine particle sizes and high inter-particle cohesive forces. Fluidized bed agglomeration is widely used to improve the instant properties of food powders. This study investigated the effect of fluidized bed agglomeration on whey protein isolate (WPI)-fortified skim milk powder (SMP) at different SMP/WPI ratios. The fluidized bed process increased the particle size distribution, and agglomerated particles with grape-like structures were observed in the SEM images. As the size increased, the Carr index (CI) and Hausner ratio (HR) values of the agglomerated WPI-fortified SMP particles exhibited excellent flowability (CI: <15) and low cohesiveness (HR: <1.2). In addition, agglomerated WPI-fortified SMP particles exhibited the faster wetting time than the instant criterion (<20 s). As a result, the rheological and physical properties of the WPI-fortified SMP particles were effectively improved by fluidized bed agglomeration. However, the fluidized bed agglomeration process led to a slight change in the color properties. The CIE L* decreased, and the CIE b* increased because of the Maillard reaction. The apparent viscosity (ηa,10) and consistency index (K) values of the rehydrated solutions (60 g/180 mL water) increased with the increasing WPI ratio. These results may be useful for formulating protein-fortified milk powder with better instant properties.

Analysis of the clinker formed in circulating fluidized bed boiler (유동층 보일러에 생성된 크링커에 대한 분석)

  • Kim, Kyeong-Sook;Park, Hyun-Joo;Lee, Tae-Won;Jeong, Nyeon-Ho
    • Analytical Science and Technology
    • /
    • v.13 no.1
    • /
    • pp.5-11
    • /
    • 2000
  • During the commissioning period in Tonghae thermal power plant which is the largest circulating fluidized bed boiler in the nation, a considerable amount of clinker was formed at FBAC and seal pot. Various attempts, for example, concentration analysis, surface phenomena, thermal characterization, and crystal structure of ash, bed sand, limestone, clinker, and mixture of each gradients have been studied to identify the causes of clinker formed in circulating fluidized bed boiler. As the results, the characterization of black particles in which separated from the clinker is more similar to that of bed sand, on the other hand, white particles are more similar to ash. In addition, the sintering temperature of sand is over $1,200^{\circ}C$ and this temperature was decreased as limestone is added to bed material. The cause of clinker was proved that ash was sticked to molten or sintered sand or limestone in the area of high temperature in the circulating system.

  • PDF

Comparative Study of Fluidized Bed-type and Assmann Psychrometer (유동층습도계와 아스만습도계의 비교 연구)

  • 강희찬;강민철
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.15 no.9
    • /
    • pp.779-785
    • /
    • 2003
  • The present work proposed a newly developed fluidized bed-type psychrometer that could be applicable to the high temperature and contaminant gases. The psychrometer is a device that test gas passes through the water in a glass bottle as a bubbly flow to obtain the adiabatic saturation temperature. A fluidized bed-type psychrometer was made and its characteristics were compared with the Assmann Psychrometer. The characteristic time was in the order of a hundred seconds, and decreased for the decrease of the mass of water and the increase of the air flow rate. The air flow rate and the insulation of the glass bottle were definitely important in the accurate measurement of the wet bulb temperature. The error in wet bulb temperature became less than 5 percent of the difference of dry and wet bulb temperatures if the air velocity in the glass bottle was greater than 1.5m/s.

Reaction Characteristics of WGS Catalyst for SEWGS Process in a Pressurized Fluidized Bed Reactor (가압 유동층 반응기에서 SEWGS 공정을 위한 WGS 촉매의 반응특성)

  • Kim, Ha-Na;Lee, Dong-Ho;Lee, Seung-Yong;Hwang, Taek-Sung;Ryu, Ho-Jung
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.23 no.4
    • /
    • pp.337-345
    • /
    • 2012
  • To check effects of operating variables on reaction characteristics of WGS catalyst for SEWGS process, water gas shift reaction tests were carried out in a pressurized fluidized bed reactor using commercial WGS catalyst and sand(as a substitute for $CO_2$ absorbent) as bed materials. Simulated syngas(mixed with $N_2$) was used as a reactant gas. Operating temperature was $210^{\circ}C$ and operating pressure was 20 bar. WGS catalyst content, steam/CO ratio, gas velocity, and syngas concentration were considered as experimental variables. CO conversion increased as the catalyst content and steam/CO ratio increased. CO conversion at fluidized bed condition was higher than that of fixed bed condition. However, CO conversion were maintained almost same value within the fluidized bed condition. CO conversion decreased as the syngas concentration increased. The optimum operation condition was confirmed and long time water gas shift reaction test up to 24 hours at the optimum operating conditions was carried out.

Electrolytic recovery of metals from the plating rinse water with fluidized bed electrode reactor (유동층전극 반응기를 이용한 폐수내의 중금속 회수)

  • Lee, Jea-Keun;Chun, Hai-Soo
    • Journal of the Korean institute of surface engineering
    • /
    • v.17 no.1
    • /
    • pp.1-6
    • /
    • 1984
  • The fluidized bed electrode reactor(FBER) with conducting particles has been made use of the removal of metals from dilute electroplating rinse water. The electrolysis was carried out under the conditions of diaphragm current density with 2~28A/$dm^2$ and bed expansion with 20~50%. Recirculating batch operations have been shown that the metal concentration dropped exponentially and may be taken down to 10 ppm. And then, the current efficiency at a concentration of 10 ppm copper was 37% under the conditions of 30% bed expansion and 6 A/$dm^2$, and at concentrated electrolyte (2000ppm copper) was over 80% in the range of 8~28A/$dm^2$ and 20~50% bed expansion. One of the technical possibilities of fluidized bed electrolysis is the separation of copper and nickel from a mixed solution of copper and nickel.

  • PDF

Biofilm Processes for Volume Decrease in Recirculating Water Treatment Systems for Aquaculture

  • Kim Jeong-Sook;Yoon Gil-Ha;Ghim See-Jun;Kang Lim-Seok;Lee Byung-Hun
    • Fisheries and Aquatic Sciences
    • /
    • v.1 no.2
    • /
    • pp.242-249
    • /
    • 1998
  • The engineering aspect of water treatment processes in the recirculating aquaculture system was studied. To recycle the water in the aquaculture system, a wastewater treatment process was required to maintain high water quality for the growth and health of the cultured fish. In this study, three different biofilm processes were used to reduce the concentration of organic matters and ammonia from the recirculating water - two phase fluidized bed, three phase fluidized bed, and trickling filter. The objectives of this research were to evaluate the optimum treatment conditions of the biofilm processes for the recirculating aquaculture system, and thereby reduce the volume of biofilm processes, which are commonly used for the recycle water treatment processes for aquaculture. The result of this study showed that the removal efficiency of organic matters by trickling filter was found to be lower than that of the fluidized bed. In the trickling filter system, anthracite showed better organic removal efficiency than crushed stone as a media. In the two phase fluidized bed, the maximum removal efficiency of either organics or ammonia was obtained when both the packing rate of media was maintained to $40\%$ of total reactor depth excepting sediment zone and the bed expansion rate was maintained to $100\%$. When 100 tilapia (Oreochromis niloticus) of each average 200g was reared, the pollutant production rate was 0.07g $NH_4\;^+-N/kg$ fish/day and 0.06g P04-3-P/kg fish/day, and sludge production rate was 0.39 g SS/kg fish/day. In the two phase and three phase fluidized bed, the volume of water treatment tank could be calculated from an empirical equation by using the relationship between the influent COD to $NH_4\;^+-N$ ratio (C/N, -), media concentration (Cm, g/L), influent ammonia nitrogen concentration (Ni, mg/L), effluent ammonia nitrogen concentration (Ne, mg/L), bed expansion rate $(E,\;\%)$, and influent flowrate $(Q,\;m^3/hr)$. The empirical equation from this study is $$V_2\;=\;10^{3.1279}\;C/N^{3.5461}\;C_m\;^{-3.7473}\;N_i\;^{4.6477}\;E^{0.0326}\;N_e\;^{-0..8849}\;Q\;(Two\;Phase\;FB) V_3\;=\;10^{11.7507}\;C/N^{-1.2330}\;C_m\;^{-6.5715}\;N_i\;^{1.5091}\;N_e\;^{-1.8489}\;Q (Three\;Phase\;FB)$$

  • PDF