• Title/Summary/Keyword: Water washing treatment

Search Result 265, Processing Time 0.021 seconds

Effect of Washing and Subsequent Heat Treatment on Water Repellency of Silk Fabric Treated with Fluorocarbon Resins

  • Park, Hyei-Ran;Lee, Mun-Cheul
    • Textile Coloration and Finishing
    • /
    • v.24 no.3
    • /
    • pp.173-179
    • /
    • 2012
  • Silk fabric treated with fluorocarbon resins (Asahi Guard AG-7005 and AG-E061) were washed and subsequently heat treated varying the washing cycles and the temperature. After the processing, the water and oil repellencies, and contact angle to water were evaluated. The water and oil repellencies decreased by the washing and recovered by following heat treatment. Also ESCA measurement was carried out to investigate the surface chemical composition of the treated fiber. The $F_1s$ intensity of the treated fabric decreased by the washing and recovered by the subsequent heat treatment. On the other hand, the $O_1s$ intensity increased by the washing and decreased by following heat treatment. From the results, it is clear that change of the water and oil repellencies of the silk fabric treated with fluorocarbon resin occurred by the washing and subsequent heat treatment. Considering a change of the water repellency of the silk fabric treated with fluorocarbon resin, it seems likely that the fluoroalkyl group of the fluorocarbon resin rotates from surface to inside of the fiber by the washing to adapt to the hydrophilic circumstance, and the orientation of the fluoroalkyl groups of the resin disturbed by the washing recovers the orientation to the fiber surface after the subsequent heat treatment.

Effect of Washing and Subsequent Heat Treatment on Water Repellency and Mechanical Properties of Nylon 6, Triacetate and Silk Fabrics Treated with Hydrocarbon Resins

  • Park, Hyei-Ran;Lee, Mun-Cheul;Nishi, Kenji;Wakida, Tomiji
    • Textile Coloration and Finishing
    • /
    • v.20 no.6
    • /
    • pp.87-91
    • /
    • 2008
  • It is commonly known that water repellency of the fabric treated with fluorocarbon resin brings about a decrease by the washing and recovers by the subsequent heat treatment. In this article, effect of the water repellency was investigated on the nylon 6, triacetate and silk fabrics treated with hydrocarbon and silicon resins. Hydrocarbon and silicon resins have been widely used in the textile finishing as the softening and water proofing agents. The fabrics were treated with hydrocarbon resins, Paragium JQ and RC (Ohara Paragium Chemical Co.) and a silicon resin, Poron MR (Shinetsu Chemical Co.), and then washed and subsequently heat treated. Although the water repellency increased by the resin treatment, it decreased by the washing apparently and recovered a little by the heat treatment. The effect of the heat treatment was small comparing with that of the fluorocarbon resin. Furthermore, as a mechanical property of the treated fabric, KES shearing and bending hysteresis parameters, modulus and hysteresis width of the hydrocarbon resin-treated nylon 6, triacetate and silk fabrics decreased by the heat treatment after washing. Therefore, the treatment is effective at improving the softening of the fabric in water repellent finish.

Effect of Washing Treatment of Aged Paper Materials for Better Conservation (열화된 종이자료의 보존성 개선을 위한 세척처리 특성)

  • Lee, Kwi-Bok;Seo, Yung-Bum;Park, So-Yeon;Jeon, Yang;Shin, Jong-Soon
    • Journal of Korea Technical Association of The Pulp and Paper Industry
    • /
    • v.38 no.4 s.117
    • /
    • pp.53-60
    • /
    • 2006
  • Paper materials for long term conservation suffer slowly mechanical and chemical deterioration, the extent of which may depend upon their conservation environment. Those deterioration includes discoloring, low moisture content, acidification, and brittleness. To slow deterioration, washing treatment, deacidification, and polymer reinforcement on paper materials are usually used. One easy and simple method of fixing low moisture content and acidification was an washing method, and we used both distilled and alkali water in washing method in this study. Alkali water is electrolyzed cathode water of high pH, and has no alkali metal ions in it. Experiment showed that washing treatment with both distilled and alkali water gave improvement in raising moisture content, pH, and mechanical strength of paper materials even after severe accelerated aging test. Advantageous effect of alkali water over distilled water on preventing deterioation was also shown clearly.

Full-scale Soil Washing and Non-discharged Washing Water Treatment Process of Soil Contaminated With Petroleum Hydrocarbon (현장규모의 유류오염 토양세척 및 무방류 세척 유출수 처리 공정)

  • Seo, Yong-Sik;Choi, Sang-Il;Kim, Jong-Min;Kim, Bo-Kyung;Kim, Sung-Gyoo;Park, Sang-Hean;Ju, Weon-Ha
    • Journal of Soil and Groundwater Environment
    • /
    • v.14 no.1
    • /
    • pp.61-67
    • /
    • 2009
  • A non-discharged system of sequentially physico-chemical water treatment was used to treat the contaminated water produced from washing system of soils according to full-scale soil washing. After washing the TPH contaminated soils, the remaining concentrations of COD$_{Mn}$, SS, and n-hexane were analyzed for each compartment to estimate the treatment efficiencies of non-discharged system. Three times of sampling events were conducted for 4 different compartments (sediment tank, flocculation tank, oil/water separator, and process-water tank). In addition, soil washing efficiencies and concentrations of each parameter (COD$_{Mn}$, SS, and n-hexane) for process-water tank were analyzed for about 8 months. As results, the average efficiency of soil washing was high to have 95.9%, regardless of the condition of TPH contamination level for soils, as well as the concentrations of COD$_{Mn}$, SS, and n-hexane in the process-water tank were below the regulation limits of the Water Environmental Conserveation Act. Accordingly, the full-scale washing treatment system in this study could make the washing water 100% recycled which lead the system to be environmentally-friendly and economical.

The Study on Mordant Absorption and Mordanting Treatment Condition of Natural Dyeing (천연염색의 매염제 흡착 및 매염조건에 관한 연구)

  • Chu Young-Joo
    • Journal of the Korean Society of Costume
    • /
    • v.55 no.5 s.95
    • /
    • pp.101-107
    • /
    • 2005
  • In this article, mordant absorption rate by the Change of temperature and fabric, discharge level by water washing, mordant density and method in mordant dye are going to be handled. Besides, how treatment method will have an effect on absorption rate and color, is also going to be covered. An atom extinction photometer was used to measure the amount of mordant absorbed in fabric at each temperature and mordant type. It turned out that absorption rate differs according to the type of mordant and sample or temperature. Also it turned out that the mordant input amount has little influence on absorption rate, that is to say, if though you use more mordants, just tiny amount of mordant is going to be absorbed in cloth. It is true that the higher temperature goes up, the better mordant absorption gets. It is found that the type of mordant and sample, treatment period affects the discharge rate. Normally $15{\~}98\%$ mordant comes off the fabric by water washing, to be specific, $17{\~}47\%$ Iron by water washing and it has better performance on cotton and nylon than silk, $1\%{\~}52\%$ Aluminum by water washing and better absorption on silk, $36{\~}89\%$ Chrome by water washing and better absorption on silk, $50{\~}89\%$ copper by water washing and better absorption on silk, poor on cotton. The examination of the K/S values and colors between before and after soaping has been conducted under the circumstance that the test fabrics had been treated at $80^{\circ}C$ for 30 minutes with $0.2\%$ soaping solution. In case of pre-mordanted fabrics, the K/S value nosedived after soaping, meanwhile densely mordanted fabric's K/S value soared but after soaping, it dropped sharply. It turned out that soaping treatment deteriorates absorption much more than water washing. It's considered that $0.1 \%$ (W/V) of mordant density is appropriate.

Total Waste Water at Rice Washing for Rice Cooking, its Composition and Cost Analysis (취반시 쌀씻는 물의 양과 발생한 뜨물의 구성 및 처리비용분석)

  • Shin, Dong-Hwa
    • Journal of the Korean Society of Food Culture
    • /
    • v.12 no.4
    • /
    • pp.419-421
    • /
    • 1997
  • Washing water volume of rice for cooking and rice weight for one person per meal in one household were surveyed for confirming pollution by the washing water and total losses by rice washing procedures. The mean size of a family was 4.64 persons and the mean consumption weight of rice per capital per meal was 138.43g. It is used 0.782 L of water for washing the rice per capital share. The washing water of rice was composed of 0.32% of total solid, 0.11% of soluble solid and 1.65% of solid loss to rice, and COD and BOD of it were 2.400 and 3.564 ppm respectively. Based on total population in Korea, 41 miliion, excepting age below 4, total cost for washing water of rice summed up about 1,495 billion won including 8.8 billion won for tap water cost, 11.7 billion won for waste water treatment, and 129 billion for solid loss of rice.

  • PDF

Effect of Seed Coat Softening, Washing and Drying on Seed Germination of Gourd (종피의 연화처리, 세척 및 건조가 박 종자의 발아에 미치는 영향)

  • 강진호;강신윤;전병삼;이상우
    • Journal of Life Science
    • /
    • v.12 no.6
    • /
    • pp.694-699
    • /
    • 2002
  • The present experiment was carried out to determine the effect of seed-coat softening by various chemicals, washing, chilling, and light treatment alone and in combination during desiccation of seeds on germination of gourd (Lagenaria siceraria Standl.) seeds. Potassium hydroxide, sodium hydroxide, acetone, acetonitrile, and acetamide were used as chemicals for the softening. Washing, prechilling, drying and light treatment of the softened seeds were done for a hour with tap water, for one or three weeks at 3$^{\circ}C$, 12 hr at 35$^{\circ}C$, and 14 hr a day at 3$0^{\circ}C$ with red light illumination or darkness, respectively. FR-yongjadaemok and FR-kunghap were used as test cultivars. Seed-coat softening with 10% acetone and acetonitrile for 1 hour enhanced and accelerated seed germination compared to the other chemicals and water imbibition. KOH treated for the softening was necessary to increase the germination rate of seeds for following chilling, but acetone did not influence their germinability regardless of chilling. Washing the softened seeds in tap water increased the germination rate in comparison with no-washing. During desiccation of the seeds sequentially treated with the softening, washing and chilling, red light treatment showed higher germination rate than dark one, suggesting that red light treatment are necessary during desiccation.

Changes in the Quality Characteristics of Yuzu (Citrus Junos Sieb.) after Ozone Water Washing Treatment, Sterilization and Storage Period (오존수 세척 처리에 의한 유자의 품질 특성 변화 및 저장기간별 살균 효과)

  • Bo-Bae Lee;Min-Hwan Kim;Chang-Yong Yoon;Youn-sup Cho;Seung-Hee Nam
    • The Korean Journal of Food And Nutrition
    • /
    • v.36 no.4
    • /
    • pp.236-243
    • /
    • 2023
  • The purpose of this study was to investigate the effects of sterilization, storage period and washing yuzu, according to the washing method, during the storage period. The results showed that the fungus size increased as the storage period increased, and no mold occurred in the yuzu washed with ozone water until 20 days. After 30 days of storage, a mold of 124.1±13.9 mm2 was observed. The no-treatment sample had a fungus of 814.5±72.8 mm2 in size on day 0 and the fungus the largest fungus was 6,362±636.7 mm2 on day 30. In the case of water treatment, the fungus was 286.4±31.5~4,836.4±484.6 mm2 in size. The results of the study confirmed that washing yuzu with ozone water has a sterilizing effect.

A Study on the Rotating Jet Nozzle for Washing Sand Filter in Water Purification Plant (정수장에서 회전 분사 노즐을 사용한 여과사 세척에 관한 연구)

  • 이주호;박승헌
    • Journal of the Korea Safety Management & Science
    • /
    • v.4 no.3
    • /
    • pp.177-187
    • /
    • 2002
  • The contamination problem is getting worse now a day because of the industrial activities. Recently it has been announced that there's environmental hormone in river and lake which produces clean water, also there's too many of algae reproduces under the water and some virus in the drinking water. The quality of water is very important. pure and clean water is not only a precondition for human being to live but a basic factor to improve the quality of life. so a water purification system must be developed. This study is about the surface washing treatment technique. We tried to use a rotary nozzle to get a tush degree of efficiency, for it was not enough with present way of washing. The nozzle is run by water pressure. The results of the experiment are as follows. We got a clean and equal surface after washing. After washing, the water's maximum consistency was 330NTU and it shows that this way is better than before one with 215NTU. Clean level of the filter was 6$^{\circ}$and it's 2.8 times higher than 17$^{\circ}$with the old way. We can see the results that the new way of washing is more effective than old way based on this study.

Establishment of Washing Conditions for Salad to Reduce the Microbial Hazard (샐러드의 미생물학적 위해 감소를 위한 세척 조건 확립)

  • Kim, Jeong-Weon;Kim, Soo-Hee
    • Korean journal of food and cookery science
    • /
    • v.21 no.5
    • /
    • pp.703-708
    • /
    • 2005
  • The purposes of this study were to establish washing conditions for vegetable salad to reduce the microbial hazard by using sodium hypochlorite solution and eventually to implement HACCP for salad processing. By using the salad production line of Shinkeum Co. located in Gwacheon, Gyunggi-do, salad samples were washed under several washing conditions (chlorine dip period, chlorine concentration, rinse time, etc.) to determine the most effective conditions. The original washing line consisted of 3 baths (100 ppm chlorine water dip, water rinse, and water rinse), each with a capacity of 100 L of tap water and 5 kg of salad. First, the salad samples were washed with 100 ppm of sodium hypochlorite solution for various dip times (3, 6, 9, 12 min); however, only a 1 log- or less-reduction in total microbial counts was achieved in all groups and the time of chlorine water dip was not a significant factor in reducing the microbial hazard. When another water bath was added before the chlorine water dip (4-bath washing), a 2 log-reduction in total microbial counts was achieved. This result suggested the importance of pre-dipping salad materials in water before chlorine treatment to reduce the organic load on the surface of the vegetables. Coliforms were not detected at all after washing. As the concentration of chlorine $(50{\sim}150\;ppm)$ and rinse time $(0.5{\sim}2\;min)$ increased, greater microbial reduction was achieved; however, physical damage of the salad was observed. Finally, the optimum washing conditions for salad were determined as 3 min-water dip, 3 min-chlorine (100 ppm) dip, 2 min-rinse, and 2 min-rinse.