• Title/Summary/Keyword: Water turbine

Search Result 543, Processing Time 0.022 seconds

A Feasibility Study on Adopting Sliding Pressure Operation for Drum Type Boiler

  • Baek, SeHyun;Kim, HyunHee;Park, SangBin;Kim, YoungJoo;Park, Hoyoung
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.2 no.3
    • /
    • pp.403-407
    • /
    • 2016
  • In general, drum-type boilers are designed for base load duty and applied under constant pressure operation mode. Recently, however conditions often occur that even drum-type boilers have to operate at partial load conditions. A feasibility study on adopting the sliding pressure operation for drum-type boiler was conducted, and corresponding performance changes and effects on the equipment were analyzed by utilizing a process simulation model. As a result, the conclusion was reached that drum type boilers are able to adopt the sliding pressure operation and can improve of net efficiency at part load operation in spite of the Rankine cycle efficiency reduction due to the decreases in main steam pressure. Because of thank to improvement of high pressure turbine stage-1 internal efficiency and power savings of boiler feed water pump. The sliding pressure operation is advantageous in terms of stress level relief for boiler tube as well as maintaining the rating steam temperature at part load condition. However, cautions are required because the drum boilers have poor dynamic response characteristics which may get worse during the sliding pressure operation.

A Study on the Determination of Starting Head by Comparing The Generating Power in Single Action Tidal Power Plant (발전량 비교를 통한 창조식 조력발전의 기동낙차 결정에 관한 연구)

  • Kim, Hyun-Han;Kim, Kwang-Ho
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.67 no.5
    • /
    • pp.680-687
    • /
    • 2018
  • Because of its predictability of the energy cycle and huge scale power output, the ocean energy from tidal power utilization has always received attention as a great energy source, even though its development cost, including the embankment construction, is so much higher than that of any other energy source. Nevertheless, nowadays many projects are being planned on account of institutional support from the government and the recent advance of construction technology. In Korea, the new industry field operating and managing the tidal power plant has already opened. But we are facing a number of problems for optimal operation of tidal power plant that are a lack of operation experience and a skill of professional management and others. This paper suggests a novel way to determine the starting head of power generation by generating power comparison method For this new method, the paper discusses many factors including changing the volume of the basin, the number of operating turbines and gates and forecasting the tidal amplitude and the characteristic curve of turbine and gate. Finally we verified that it can increase about 2% an annual power generation compared with the conventional method using the original operational function made in the plant design process.

A Study of Optimum Design of Impulse Turbine for 500kW Class OWC-type Wave Energy Conversion (500kW급 OWC형 파력발전장치 설계를 위한 임펄스터빈 최적 직경 산출에 대한 연구)

  • Moon, Jae-Seung;Hong, Key-Yong;Shin, Seung-Ho;Hyun, Beom-Soo;Kim, Gil-Won
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2007.12a
    • /
    • pp.123-124
    • /
    • 2007
  • 파력발전은 파랑에너지를 이용하여 유용한 에너지를 얻어내는 것인데, 본 논문에서는 그 가운데 진동수주 (Oscillating Water Column)형을 연구 대상으로 취하였다. 이는 외해에서의 파랑에너지를 공기실에 유입 집중시켜 공기실 내 수면의 승강운동을 증폭시키고 이로 인해 발생한 공기실 내의 공기 흐름을 터빈의 구동력으로 사용하는 것을 말한다. 적지 선정과정에서 채택된 곳의 설계파고를 바탕으로 원하는 정격출력인 500kW를 얻어낼 수 있도록 유량과 임펄스 터빈의 최적 직경을 산출하고자 하였는데 개념설계된 파력발전장치의 덕트가 쌍동형 형태를 취하고 있으므로 한 터빈당 250kW급을 목표 발전용량으로 하였다. 지난 연구를 통해서 기 작성된 터빈 성능도표를 활용하여, 본 연구에서는 1차적으로 임펄스 터빈의 개략적인 직경 및 유량을 구하고, 터빈의 자기 기동 특성을 고려하여 최종적인 형상을 구체적으로 도출하였다.

  • PDF

Numerical analysis of a hybrid substructure for offshore wind turbines

  • Park, Min-Su;Jeong, Youn-Ju;You, Young-Jun;Lee, Du-Ho;Kim, Byeong-Cheol
    • Ocean Systems Engineering
    • /
    • v.4 no.3
    • /
    • pp.169-183
    • /
    • 2014
  • For the reliable design of substructure supporting offshore wind turbines it is very important to reduce the effects of wave forces. Since the substructure is strongly influenced by the effects of wave forces as the size of substructure increases. In the present study, the hybrid substructure with multi-cylinder is newly suggested to reduce the effects of wave forces. Using diffraction theory the scattering waves in a fluid region are expressed by an Eigenfunction expansion method with three dimensional potential theory to calculate the wave force acting on the hybrid substructure. The wave force and wave run-up acting on the hybrid substructure is presented to examine the water wave interaction according to the variation of cylindrical size and the distance among cylinders. It is found that the suggested hybrid substructure with multi-cylinder is very useful to reduce the effects of wave forces acting on the substructure for offshore wind turbines.

A Development of Digital Control System for FWPT In Nuclear Power Plant (원전 급수펌프 구동용 터빈 제어시스템 개발)

  • Choi, In-Kyu;Jeong, Chang-Ki;Kim, Byoung-Chul;Kim, Jong-An;Woo, Joo-Hee
    • Proceedings of the KIEE Conference
    • /
    • 2006.07d
    • /
    • pp.1885-1886
    • /
    • 2006
  • The thermal energy from nuclear fission is transferred to the steam generator which is a kind of a large heat exchanger. After the feedwater is injected into the steam generator and absorbs the thermal energy, it is converted into the steam. This steam goes into the turbine. The balance between the generated energy and the consumed energy is required for the nuclear power plant to be stable. For the purpose of which, the feed water, a parameter for energy transfer, should be controlled in stability. Usually, the nuclear power plants are operated in base load in the view of power system for the stability of fission system. Therefore, though there will be almost no unbalance, there can be some instability from unbalance in case of startup/shutdown or disturbance. In this case, the controllability of feedwater pump is very important for the quick recover of stability.

  • PDF

Bubble size characteristics in the wake of ventilated hydrofoils with two aeration configurations

  • Karn, Ashish;Ellis, Christopher R;Milliren, Christopher;Hong, Jiarong;Scott, David;Arndt, Roger EA;Gulliver, John S
    • International Journal of Fluid Machinery and Systems
    • /
    • v.8 no.2
    • /
    • pp.73-84
    • /
    • 2015
  • Aerating hydroturbines have recently been proposed as an effective way to mitigate the problem of low dissolved oxygen in the discharge of hydroelectric power plants. The design of such a hydroturbine requires a precise understanding of the dependence of the generated bubble size distribution upon the operating conditions (viz. liquid velocity, air ventilation rate, hydrofoil configuration, etc.) and the consequent rise in dissolved oxygen in the downstream water. The purpose of the current research is to investigate the effect of location of air injection on the resulting bubble size distribution, thus leading to a quantitative analysis of aeration statistics and capabilities for two turbine blade hydrofoil designs. The two blade designs differed in their location of air injection. Extensive sets of experiments were conducted by varying the liquid velocity, aeration rate and the hydrofoil angle of attack, to characterize the resulting bubble size distribution. Using a shadow imaging technique to capture the bubble images in the wake and an in-house developed image analysis algorithm, it was found that the hydrofoil with leading edge ventilation produced smaller size bubbles as compared to the hydrofoil being ventilated at the trailing edge.

화력발전소 CWD(Cooling Water Discharge)를 활용한 해양소수력 개발의 기술적인 고찰(화력발전소 CWD와 조위특성과의 Harmony)

  • Eom, Bok-Jin
    • 열병합발전
    • /
    • s.69
    • /
    • pp.15-20
    • /
    • 2009
  • 소수력 계획 시 개발지점에 대하여 수많은 자료와 정보 등을 필요로 하게 되는데 특히 해당지역내의 유량분포에 대한 유황자료는 개발의 판단여부를 결정케 하는 중요한 요소이다. 소수력발전소의 설비용량에 직접 관계되는 설계유량의 결정과 재해방지를 위한 유출의 예측을 가능케 하고 발전소운영 시 가동률 및 경제성에도 직접적인 영향을 미치는 중용한 요소이나 여기서 논하는 소수력개발은 하천이나 댐과 같은 유형이 아니라 일정한 유량을 확보하여 배출하기 때문에 문제는 없다. 그러나 계절별 부하에 따른 냉각수량의 변화 및 소수력 발전유량의 변동, 조위(해수면) 변화 등에 따라 달라진다. 그러므로 수위조절을 위한 수문은 이들의 변화에 따라 자동운전이 가능해야 하지만 운전시 발전정격수위를 맞출 수 있도록 수문을 조절한 다음 Turbine Governor에 의해 유량 및 수위를 제어할 수 있도록 설계하여 냉각수 순환수 계통에 영향이 미치지 않게 언제나 적정수위를 유지시킬 수 있는 운전모드로 구축하는 것이 안정이라 볼 수 있다. 소수력발전설비 및 수문의 오작동 및 고장이 발생할 때 수위가 상승하여 냉각계통에 손실수두 증가, 취수펌프의 양정고 증가와 Surge 발생 등으로 발전소의 정상 운전에 미치는 영향이 없어야 하므로 세밀한 검토가 필요하기 때문에 폐쇄시간과 수압상승 값 등 요인 분석후 설계하여야 한다. Figure A와 같이 국내 화력발전단지에서 냉각수로 사용되고 방류되는 해수는 발전소에 따라 ca.70~150 CMS로 ca.2,000~5000 kW 이상의 수력에너지(H=4m 형성 기준)를 보유하고 있으나, 현재 활용되지 못하고 그대로 해양으로 방류되고 있어 이 수력에너지의 개발 방안을 오래전부터 검토하여 왔다. 발전소 온배수의 원활한 배수를 위한 설계 낙차와 함께 남서해안의 조위변화에 따른 낙차를 이용하는 것으로 소수력 발전 방식과 조력발전 방식의 특징을 동시에 활용할 수 있다.

  • PDF

Influence of the Number of Runner Vanes on Tubular-type Hydroturbine (소형 튜블러수차의 러너베인 깃 수의 영향)

  • Nam, Sang-Hyun;Kim, You-Taek;Choi, Young-Do;Lee, Young-Ho
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.32 no.6
    • /
    • pp.908-914
    • /
    • 2008
  • The world is facing a serious energy problem which destroying the environment. In addition, fossil fuel such as oil and coal that caused global warming and the environmental problems due to acid rain had been gradually exhausted. To solve this problem that has crisis of energy, it is necessary time and effort for research and development of renewable energy in the future. As alternative energy, small hydropower generation which has output of less or equal to 100kW is attracting considerable attention. This is because of its small, simple, renewable, and large amount of energy resources. By using a small hydropower generator of which main concept is based on using the different water pressure levels in pipe lines, energy which was initially wasted by use reducing of a valve at the end of the pipeline, is collected by turbine in the small hydropower generator. In this study, we investigated the influence of the number of runner vanes on the characteristics of tubular-type hydroturbine.

Study on TES system application for industrial production facility (축냉시스템의 산업용 생산설비 적용에 대한 고찰)

  • Park, C.H.;Hong, S.S.;Kim, J.R.;Park, S.S.;Hwang, H.S.
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.1288-1293
    • /
    • 2009
  • The TES (Thermal Energy Storage) cooling system utilizing cheaper off-peak electricity has been applied just for building air-conditioning currently and causes limitation of usage rate and inefficiency of national resources utilization. In this regard, more says the necessity to apply TES system in industrial cooling system which is longer using period and wider usage. In this study, we will approve the technical and economical improvement in efficiency of industrial cooling system applied TES system by utilizing cheaper off-peak electricity and it will attribute the promotion of TES system and stabilization of supply and demand of electric power by proving the necessity to develop more efficient industrial cooling system by combining TES system.

  • PDF

Performance Analysis of a Wet Air-Cycle Refrigeration System (습공기사이클 냉동시스템의 성능해석)

  • Won, Sung Pil
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.26 no.11
    • /
    • pp.504-511
    • /
    • 2014
  • The objective of this study is to theoretically analyze the performance of an open wet air-cycle refrigeration system, which nowadays is increasingly generating environmental concern. The temperature and relative humidity of the outside air are selected as the most important parameters. As the temperature and relative humidity of the outside air increase, the pressure ratio of the ACM compressor is determined to be nearly constant, the air temperature at the exit of the system increases, and the amount of condensed water, the cooling capacity, the COP, and the total entropy production rate increase overall. The effects of the effectiveness of the heat exchanger and the efficiency of the turbine on the performance are greater than that of the efficiency of the ACM compressor. Also, the performance of the wet air-cycle refrigeration system with two heat exchangers is enhanced, with a high COP and low total entropy production rate, compared to the system with a single heat exchanger.