• 제목/요약/키워드: Water temperature stress

검색결과 643건 처리시간 0.028초

혈액모사유체의 미세협착 주변 맥동유동 시뮬레이션 (Numerical Simulation of Pulsatile Flows around Micro-Stenosis for Blood Analog Fluids)

  • 송재민;홍현지;하이경;염은섭
    • 한국가시화정보학회지
    • /
    • 제17권2호
    • /
    • pp.10-16
    • /
    • 2019
  • Considering the role of viscosity in the hemorheology, the characteristics of non-Newtonian fluid are important in the pulsatile blood flows. Stenosis, with an abnormal narrowing of the vessel, contributes to block blood flows to downstream tissue and lead to plaque rupture. Therefore, systematic analysis of blood flow around stenosed vessels is crucial. In this study, non-Newtonian behaviors of blood analog fluids around the micro-stenosis with 60 % severity in diameter of $500{\mu}m$ was examined by using CFX under the pulsatile flow conditions with the period of 10 s. Viscosity information of two non-Newtonian fluids were obtained by fitting the value of normal blood and highly viscous blood. As the Newtonian fluid, the water at room temperature was used. During the pulsatile phase, wall shear stress (WSS) is highly oscillated. In addition, high viscous solution gives rise to increases the variation in the WSS around the micro-stenosis. Highly oscillating WSS enhance increasing tendency of plaque instability or rupture and damage of the tissue layer. These results, related to the influence on the damage to the endothelium or stenotic lesion, may help clinicians understand relevant mechanisms.

23Cr26Ni 내열강의 피로 특성 (Fatigue Behavior of 23Cr26Ni Heat Resistant Steel)

  • 이희웅;권숙인
    • 열처리공학회지
    • /
    • 제24권2호
    • /
    • pp.92-98
    • /
    • 2011
  • The influence of the cooling condition after solution treatment on the high temperature fatigue resistance of 23Cr-26Ni heat resistant steel was investigated. Two different cooling conditions were applied to the steel after solution treatment at $1200^{\circ}C$ for 3 hours. One specimen was water quenched immediately after the solution treatment. The other one was furnace cooled at a rate of $0.5^{\circ}C/min$ down to $750^{\circ}C$ after the solution treatment. Then, both specimens were aged at $750^{\circ}C$ for 5 hours. Under two different heat treatment conditions, the low cycle fatigue (LCF) test was performed at $600^{\circ}C$ and room temperature (RT). Only cyclic hardening continued from the beginning until fracture at all strain amplitudes during LCF at $600^{\circ}C$. This phenomenon was attributed to the increase in the dislocation density due to cyclic deformation, which resulted in the interaction between the newly created dislocations and precipitates. Cyclic hardening followed by saturation and cyclic softening was observed at RT. Cyclic softening was attributed to the dislocation annihilation rate exceeding the dislocation generation rate. Other probable factor for cyclic softening was some cavities formed around grain boundaries after 20 cycles. WQ and FC have a similar LCF behavior at RT and $600^{\circ}C$ as shown in the cyclic stress response curves.

콘크리트포장의 줄눈의 잠김에 대한 연구 (A Study for Joint Freezing in Concrete Pavement)

  • 이승우
    • 한국도로학회논문집
    • /
    • 제3권1호
    • /
    • pp.165-176
    • /
    • 2001
  • 줄눈콘크리트포장의 줄눈은 온도 및 습도변화에 기인하여 발생하는 슬래브내에 무작위하게 발생하는 균열을 제어할 목적으로 설계된다. 이러한 인위적인 균열 (줄눈)은 자연발생적인 균열에 비하여 줄눈채움, 하중전달장치등의 보호대책을 강구하는 것이 용이하다는 장점을 가지고 있다. 줄눈채움의 잠재적인 이점은 표면수의 하부층으로의 침투로 인한 하부층의 약화 및 비압축성 물질 (작은 입자위 골재)의 줄눈내에 끼어듦으로 인한 스폴링을 방지하는데 있다. 합리적인 줄눈 채움의 설계를 위해서는 줄눈폭의 변화 (줄눈의 수평 움직임)의 산정이 중요한 입력요소이다. LTPP SMP 연구에 포함된 16개의 줄눈콘크리트포장의 줄눈의 수평움직임에 대한 장기 현장계측자료를 토대로 상당수의 줄눈에서 수평움직임을 허용하지 않고 있다는 것이 밝혀진바 있다. 이러한 현상을 줄눈잠김이라고 한다. 줄눈잠김이 발생하는 원인은 설계상에 계획된 줄눈부의 균열이 발생하지 않기 때문이라고 추정된다. 본 연구에서는 임의의 줄눈콘크리트포장에서 줄눈잠김의 비율을 예측할 수 있는 모델을 제시하였고 줄눈 잠김이 포장체의 성능에 미치는 영향을 조사하였다.

  • PDF

HPT 방식의 온열침대 디자인 개발에 관한 연구 (A Study on Thermo-Bed Design Development of HPT System)

  • 이봉규
    • 한국가구학회지
    • /
    • 제22권1호
    • /
    • pp.72-81
    • /
    • 2011
  • These days, beds have been developed not as furniture to sleep in but Healthcare Furniture. The function of heating, non-electronic-waves and far-infrared rays have been added. Also, eco-friendly materials such as stone, mud, rubber and wood are combined to them together with the radiation-heating method using heat conduction through electronic coil and hot water circulation. Modern people suffer from stress and fatigue. The hot issue is "health." Focused on the health, the development of design for beds considering the influence electronic waves, anions, deep sleep and the density of toxic materials have on human bodies has become urgent. In this study, the trend, specification and efficiency of the functional health-related electronic coil technology are analyzed. Through the analysis, the environmental standards are set. According to them, technology, eco-friendly materials and additional functions for the development of the design are considered. Also, the government is promoting the IEC international standardization for the Korean traditional floor heating style beds. In preparation for that, we adopted new HPT method technology. It enables non-electronic-waves, low electricity and stable temperature maintenance control for the warm top and the cool bottom. Also, the head boards and the frames of the beds can be separated. Through this separation, the beds can be easily moved or installed. Eco-friendly materials such as Hinoki cypress wood and red clay and the existing tables function are combined to the head boards so they can be used as drawers and display shelves. If they are used as separate items, they can be used as covers. This is how we suggest the design for the heating beds.

  • PDF

수치모델을 이용한 한국 남해안 전선의 계절변동 (Seasonal Variation of Coastal Front by Numerical Simulation in the Southern Sea of Korea)

  • 배상완;김동선
    • 한국환경과학회지
    • /
    • 제20권9호
    • /
    • pp.1141-1149
    • /
    • 2011
  • The three-dimensional hydrodynamic model was simulated to understand coastal sea front of formation and seasonal variation in the Southern Sea of Korea. In this study, we used to concept of stratification factor, to realize seasonal distribution of stratification coefficient which of seasonal residual flow, considered with, tide, wind and density effect. Tidal current tends to flow westward during the flood and eastward during ebb. The current by the wind stress showed to be much stronger the coastal than the offshore area in the surface layer. And the current by the horizontal gradient of water density showed to be relatively weak in the coastal area, with little seasonal differences. On the other hand, the flow in the offshore area showed results similar to that of the Tsushima Warm Current. The stratification factor (SHv) was calculated by taking into account the total flow of tide, wind and density effect. In summer, the calculated SHv distribution ranged from 2.0 to 2.5, similar to that of the coastal sea front. The horizontal temperature gradient showed to be strong during the winter, when the vertical stratification is weak. On the other hand, the horizontal gradient became weak in summer, during which vertical stratification is strong. Therefore, it is presume that the strength of vertical stratification and the horizontal temperature gradient affect the position of the coastal sea front.

암반의 수리인자에 미치는 열적.역학적 영향에 대한 실험적 검증 (Experimental Study of Thermal-mechanical Influence on the Hydraulic Properties of Rock)

  • 전석원;홍창우;이주현;강주명;배대석
    • 한국지반공학회논문집
    • /
    • 제19권5호
    • /
    • pp.59-67
    • /
    • 2003
  • 본 연구에서는 지하수 유동 특성 해석의 신뢰도 증진을 위해서 우리나라 심부결정질 암석의 접촉 면적과 간극의 변화양상, 구속압과 온도에 따라 유체투과율의 변화 양상을 살펴보고자 하였다. 또한 역학적 물성과 열적 물성을 측정하여 모델링의 입력자료에 대한 신빙성을 높일 수 있도록 하였다. 실험 결과 초기 평균 간극은 544.33$\mu\textrm{m}$∼898.62$\mu\textrm{m}$ 범위를 보였으며 분포특성은 로그-정규분포 형태를 보였다. 구속압 변화에 따라 유체투과율은 감소하는 경향이 나타나고 온도 증가에 따라 유체투과율이 감소하는 경향을 보였으며 접촉 면적이 커지면 유체투과율 변화 폭이 작아짐을 이론과 실험을 통해 규명하였다. 암석의 역학적, 열적 물성을 측정한 결과 기존에 측정된 우리나라 화강암의 물성치와 근사한 값을 가지는 것으로 나타났다.

12Cr합금강의 부식열화에 의한 피로파괴 특성 (Fatigue Fracture Characteristics by Corrosion Degradation of 12Cr Alloy Steel)

  • 조선영;김철한;배동호
    • 대한기계학회논문집A
    • /
    • 제25권6호
    • /
    • pp.996-1003
    • /
    • 2001
  • In order to investigate the fatigue fracture characteristics by corrosion degradation of 12Cr alloy steel, both the fatigue characteristics in air of them artificially degraded during long period and the corrosion fatigue characteristics were experimentally evaluated in various environments which were determined from electro-chemical polarization tests. And also, their fracture mechanisms were analyzed and compared, fractographyically. From their results, the fracture mechanical characteristics of it artificially degraded during long period in the distilled water, 3.5 wt.% NaCl solution and 12.7wt.%(1M) Na$_2$SO$_4$solution of 25, 60 and 90$\^{C}$ did not show distinguishable difference comparing with non-corroded one in regardless of temperature and degradation period. It means that degradation of the material by just surface corrosion does not remarkably affect to fatigue crack growth. On the other hand, the crack growth rates by corrosion fatigue increased due to activity increase of corrosive factors such as OH(sub)-,Cl(sup)- and SO$_4$(sup)- at the crack tip with temperature increase. Therefore, the crack growth rates by corrosion fatigue were more faster than that in air of the artificially degraded specimen due to the such difference of crack growth mechanism.

세립분 함유량에 따른 동결 사질토의 응력-변형률-강도 특성 (Stress-Strain-Strength Characteristics of Frozen Sands with Various Fine Contents)

  • 채덕호;황범식;조완제
    • 한국지반환경공학회 논문집
    • /
    • 제16권6호
    • /
    • pp.31-38
    • /
    • 2015
  • 최근 우리나라는 러시아 극동 지역의 천연파이프 건설과 제2남극기지인 장보고 기지건설이 이루어지면서 영구동토지반에서의 구조물 건설에 대한 관심이 증대되고 있다. 세립분 함유량이 동결된 사질토의 역학적 거동에 미치는 영향을 파악하기 위하여 온도 -5, -10, $-15^{\circ}C$의 조건에서 세립분 함유량 0, 5, 10, 15%의 시료에 대해 일축압축시험을 수행하였다. 동결 사질토를 성형하기 위해 입도가 균일한(SP) 주문진 표준사와 소성성이 낮은 실트(ML)인 카올리나이트를 사용하였다. 성형된 동결 사질토를 사용하여 온도를 제어할 수 있는 냉동 체임버에서 일축압축실험을 수행하였고 강도 및 강성특성을 파악하기 위해 최대 일축압축강도와 변형계수를 분석하였다. 그 결과 동결 사질토의 강도 및 강성은 세립분 함유량이 증가할수록 감소하는 경향을 보이고 온도가 낮아짐에 따라 증가하는 경향을 보였다.

배수성이 다른 자생 버뮤다그래스의 휴면 전후 항산화 효소활성 및 세포막 안정성 변화 (Antioxidant Enzyme Activity and Cell Membrane Stability of Korean Bermudagrass Genotypes Different in Ploidy at Dormant Stage)

  • 이긍주;이혜정;마기윤;전영주;김인경
    • 아시안잔디학회지
    • /
    • 제25권1호
    • /
    • pp.17-21
    • /
    • 2011
  • 기존 보고된 바에 의하면 한국 자생 버뮤다그래스는 군집 내에서 형태학, 생육 특성, 세포학적 특성에 대해 유전적으로 매우 다양한 변이를 보여주었다. 버뮤다그래스의 염색체 수와 핵 DNA 량에 따르면 배수성 수준의 범위가, 3배 체(2n=3x), 4배체(2n=4x), 5배체(2n=5x), 6배체(2n=6x)로 나타났었다. 본 연구에서는 한국에서 휴면이 유도되는저온과 짧은 일장에 대한 항산화효소(superoxide dismutase, catalase, peroxidase, ascorbate peroxidase)의 다양한 반응과 각 버뮤다그래스 세포형의 세포막 안정성을 조사하였다. 모든 항산화효소는 휴면 기간동안 높게 나타났으나, 과산화수소를 물과 산소 분자로 변환시키는 헴기를 함유한 카탈라제는 6배체 버뮤다그래스를 제외한 세 개의 세포형에서 휴면이 개시되기 전에 활성화되었다. 상대적으로 세엽이며 생육속도가 빠른3배체와 4배체는 superoxide dismutase와 peroxidase 효소의 활성이 증가됨을 확인하였다. 수산기를 가진 라디칼에 의해 손상을 받은 세포막에서 지질과산화의 산물인 말론디알데히드(MDA)는 온도가 감소함에 따라 모든 세포형에서 증가되었고, 방어적인 항산화효소를 더 갖고 있는 3배체와 4배체는 MDA 생산이 현저하게 더 낮게 나타났다. 전해질 유출은 5배체와 6배체에서 더 높았던 것과 유사하게, 저온이 적용될 때 외견상으로 세포막에 더 손상을 받는 것 같았다. 실험 결과, 서로 다른 세포형(cytotype)의 항산화 반응은 유전적으로 특이적이며, 이는 버뮤다그래스에서 저온 저항성과의 연관성을 분자 수준에서 더 연구하는 것이 필요하다.

유한요소법을 이용한 원자로 상부헤드 CRDM 관통노즐 J-Groove 보수용접 영향 분석 (Effects of Repair Weld of Reactor Pressure Vessel Upper Head Control Rod Drive Mechanism Penetration Nozzle on J-Groove Weldment Using Finite Element Analysis)

  • 김주희;유삼현;김윤재
    • 대한기계학회논문집A
    • /
    • 제38권6호
    • /
    • pp.637-647
    • /
    • 2014
  • 국내 가압경수로형 원자로의 압력용기 상부헤드에는 많은 제어봉구동장치(CRDM) 노즐이 분포한다. 이들 노즐은 억지끼워맞춤(Shrink fitting) 방식으로 결합되어 용접 처리 된다. 용접에 의해 발생되는 인장잔류응력은 일차수응력부식균열을 발생시키는 주요 요인이다. 이러한 이유로 최근 15 여 년 동안 관통노즐 용접부 부위에서 균열 발생 사례가 증가하고 있으며, 이를 극복하기 위해 다양한 방안이 모색되고 있다. 또한 용접과정에서 발생되는 불필요한 결함은 일차수응력부식균열(PWSCC)을 가속화 시키는 원인이 되기도 한다. 원자로 제작과정에서 용접에 의한 결함은 보수용접에 의해 즉시 수리가 이루어 진다. 기존의 연구에서는 정상적인 용접과정에서 발생되는 잔류응력을 예측하였으나, 본 연구에서는 용접과정에서 발생되는 결함을 보수하기 위해 실시되는 보수용접이 용접잔류응력에 미치는 영향을 분석하였다.