• 제목/요약/키워드: Water surface identification

검색결과 89건 처리시간 0.03초

Development of a device to improve the precision of water surface identification for MeV electron beam dosimetry

  • F. Okky Agassy;Jong In Park;In Jung Kim
    • Nuclear Engineering and Technology
    • /
    • 제56권4호
    • /
    • pp.1431-1440
    • /
    • 2024
  • The study aimed to develop a laser-based distance meter (LDM) to improve water surface identification for clinical MeV electron beam dosimetry, as inaccurate water surface determination can lead to imprecise positioning of ionization chambers (ICs). The LDM consisted of a laser ranging sensor, a signal processing microcontroller, and a tablet PC for data acquisition. I50 (the water depth at which ionization current drops to 50 % of its maximum) measurements of electron beams were performed using six different types of ICs and compared to other water surface identification methods. The LDM demonstrated reproducible I50 measurements with a level of 0.01 cm for all six ICs. The uncertainty of water depth was evaluated at 0.008 cm with the LDM. The LDM also exposed discrepancies between I50 measurements using different ICs, which was partially reduced by applying an optimum shift of IC's point of measurement (POM) or effective point of measurement (EPOM). However, residual discrepancies due to the energy dependency of the cylindrical chamber's EPOM caused remained. The LDM offers straightforward and efficient means for precision water surface identification, minimizing reliance on individual operator skills.

Occurrence and Molecular Differentiation of Environmental Mycobacteria in Surface Waters

  • Lee, Eun-Sook;Lee, Mok-Young;Han, Sun-Hee;Ka, Jong-Ok
    • Journal of Microbiology and Biotechnology
    • /
    • 제18권7호
    • /
    • pp.1207-1215
    • /
    • 2008
  • To investigate the occurrence and species diversity of mycobacteria in waters, surface water samples were collected monthly from the Han River and tap water samples at the terminal sites of the distribution system. Mycobacteria in each water sample were isolated by decontamination using cetylpyridinium chloride (CPC) and cultivation on Middlebrook 7H10 agar, and then identified by polymerase chain reaction-restriction fragment length polymorphism analysis (PRA) and sequencing of the 65-kDa heat-shock protein gene (hsp65 gene). Mycobacteria were detected in 59% of the surface water samples and 26% of the tap water samples. Over half of the 158 isolates could not be identified by hsp65 PRA and gene sequencing, and several identification discrepancies were observed between the two methods. The most frequently isolated species was Mycobacterium gordonae in surface water and M. lentiflavum in tap water. M. avium complex (MAC), the most important pathogen among environmental mycobacteria, was detected in the surface water samples but not found in the tap water samples. The result demonstrated that water is an important environmental source of mycobacteria and the combined application of hsp65 PRA and sequencing was more reliable than hsp65 PRA alone to accurately identify mycobacteria present in water.

표면침투제를 이용한 원전구조물의 내구성 향상 (Improvement of the Exisiting Nuclear Concrete Structures Durability Using Surface Penetration Sealer)

  • 노병철;최규형;이상민
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2004년도 추계 학술발표회 제16권2호
    • /
    • pp.257-260
    • /
    • 2004
  • The durability and water - resisting capability of nuclear concrete structures can be greatly improved as the density of concrete surface increases. Applying the surface penetration sealer to the concrete surface can increase the surface density. Therefore, the objective of this study is to identify the most suitable surface penetration sealer based on lab test. The considered parameters rate and water resistance and absorbance rate of the concrete specimen after the penetration sealer are applied. The experimental study resulted in the identification of the two most suitable surface penetration sealer based on their performance.

  • PDF

Oxygen Isotope Data of Winter Water in the Western Weddell Sea: Preliminary Results

  • Khim, Boo-Keun;Park, Byong-Kwon;Kang, Sung-Ho
    • Journal of the korean society of oceanography
    • /
    • 제33권1-2호
    • /
    • pp.1-7
    • /
    • 1998
  • In the western Weddell Sea, winter mixed layer is characterized by near-freezing temperature and higher salinity due to brine injection through sea-ice formation. This layer becomes Winter Water being capped by warmer and less saline Antarctic Surface Water during the sea-ice melt-ing season. In this study, Winter Water was preliminarily identified by the oxygen isotopic com-positions. The ${\delta}^{18}$O values of Winter Water show the progressively increasing trend from south to north in the study area. It presumably reflects the enhanced mixing with Antarctic Surface Water due to the extent of influence by low S'"0 value of sea-ice/glacier meltwater. Correlations between salinity and 6'"0 values of seawater can be used to more generally characterize Winter Water with a view to identification. However, the prediction on the degree of mixing from these relationships needs more detailed isotope data, although this study allows the oxygen isotopic composition of seawater as a tracer to identify the water mass.

  • PDF

토굴저장 생강의 부패에 관여하는 미생물의 동정 및 병원성 (Identification and Pathogenicity of Microorganisms Associated with Seed-Rhizome Rot of Gingers in Underground Storage Caves)

  • 김충회;양종문;양성석
    • 한국식물병리학회지
    • /
    • 제14권5호
    • /
    • pp.484-490
    • /
    • 1998
  • Microorganisms associated with seed-rhizome rot of gingers preserved in three underground storage caves were identified with respect to rot types. Rot patterns were grouped into 4 different types : yellow soft rot, brown rot, localized ring rot, and water-soaked rot. Water-soaked rot was highest in frequency with 40% and ring rot the least with 14%. Causal pathogens differed with rot type, yellow soft rot by Erwinia carotovora and Pseudomonas aeruginosa, brown rot by Fusarium solani and Pseudomonas aeruginosa, localized ring rot by F. solani, and water-soaked rot by Pythium spinosum and P. ultimum. Pythium myriotylum, the causal pathogen of ginger rhizome rot which occurs severely in fields was rarely detected from storage seed-rhizomes suggesting its minor involvement with storage rot. Pathogenic Pythium isolates were frequently obtained from both rhizome surface and inner tissues of rotten rhizomes. Detection frequency of Pythium isolates in inner tissues decreased as increasing distance from rhizome surface. In wound-inoculation tests, above pathogens caused a varying degree of rot on healthy rhizomes at 15$^{\circ}C$, 2$0^{\circ}C$ and 3$0^{\circ}C$ with increasing severity at higher temperatures.

  • PDF

A novel approach to bind graphene oxide to polyamide for making high performance Reverse Osmosis membrane

  • Raval, Hiren D.;Das, Ravi Kiran
    • Membrane and Water Treatment
    • /
    • 제8권6호
    • /
    • pp.613-623
    • /
    • 2017
  • We report the novel thin film composite RO membrane modified by graphene oxide. The thin film composite RO membrane was exposed to 2000 mg/l sodium hypochloride; thereafter it was subjected to different graphene oxide concentration ranging from 50 mg/l to 1000 mg/l in water. The resultant membrane was crosslinked with 5000 mg/l N-hydroxysuccinimide. The performance of different membranes were analysed by solute rejection and water-flux measurement. It was found that 100 mg/l graphene oxide exposure followed by 5000 mg/l N-hydroxysuccinimide treatment resulted in the membrane with the highest solute rejection of 97.78% and water-flux of 4.64 Liter per sqm per hour per bar g. The membranes were characterized by contact angle for hydrophilicity, scanning electron micrographs for surface morphology, energy dispersive X-Ray for chemical composition of the surface, Atomic force microscope for surface roughness, ATR-FTIR for chemical structure identification. It was found that the graphene oxide modified membrane increases the salt rejection performance after exposure to high-fouling water containing albumin. Highly hydrophilic, antifouling surface formation with the nanomaterial led to the improved membrane performance. Moreover, the protocol of incorporating nanomaterial by this post-treatment is simple and can be applied to any RO membrane after it is manufactured.

Groundwater and Surface Water Hydrology in the Lake Rotorua Catchment, New Zealand, and Community Involvement with Lake Water Quality Restoration

  • White, Paul A.;Hong, Timothy;Zemansky, Gil;McIntosh, John;Gordon, Dougall;Dell, Paul
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 2007년도 학술발표회 논문집
    • /
    • pp.8-14
    • /
    • 2007
  • Water quality in Lake Rotorua, New Zealand, deteriorated since the 1960s because of excessive phytoplankton growths due principally to increasing nitrogen and phosphorus in the lake waters. Nutrient concentrations in eight of the nine major streams feeding Lake Rotorua have increased since 1965. The groundwater system has a key role in the hydrology of the Lake Rotorua catchment and the groundwater system is probably the control on the time delay between intensification of agricultural land use and response of surface water quality. All major, and many minor streams, in the catchment are fed by springs. Two lithological units are most important to groundwater flow in the Lake Rotorua catchment: Mamaku Ignimbrite, erupted in about 200,000 years ago and Huka Formation sediments which filled the caldera left by the Mamaku Ignimbrite eruption. Rainfall recharge to groundwater in the groundwater catchment of Lake Rotorua is estimated as approximately 17300 L/s. A calibrated steady-state groundwater flow model estimates that approximately 11100 L/s of this flow discharges into streams and then into the lake and the balance travels directly to Lake Rotorua as groundwater discharge through the lake bed. Land use has impacted on groundwater quality. Median Total Nitrogen (TN) values for shallow groundwater sites are highest for the dairy land use (5.965 mg/L). Median TN values are also relatively high for shallow sites with urban-road and cropping land uses (4.710 and 3.620 mg/L, respectively). Median TN values for all other uses are in the 1.4 to 1.5 mg/L range. Policy development for Lake Rotorua includes defining regional policies on water and land management and setting an action plan for Lake Rotorua restoration. Aims in the action plan include: definition of the current nutrient budget for Lake Rotorua, identification of nutrient reduction targets and identification of actions to achieve targets. Current actions to restore Lake Rotorua water quality include: treatment of Tikitere geothermal nitrogen inputs to Lake Rotorua, upgrade of Rotorua City sewage plant, new sewage reticulation and alum dosing in selected streams to remove phosphorus.

  • PDF

무주지역 수질특성자료의 통계학적 분석에 의한 소유역 구분 (Watershed Classification Using Statistical Analysis of water Quality Data from Muju area)

  • 한원식;우남칠;이기철;이광식
    • 한국지하수토양환경학회지:지하수토양환경
    • /
    • 제7권3호
    • /
    • pp.19-32
    • /
    • 2002
  • 본 연구는 무주군 적상산 부근에 위치하는 소유역에서 지표수의 수질과 인접한 천층지하수 수질사이의 관계 및 지질매체와 오염원의 유입에 의한 계절적인 변동을 규명하기 위하여 수행되었다. 8월과 10월 두 차례의 조사결과 이곳 지표수와 지하수 수질은 Ca-$HCO_3$유형이 주를 이루고 있었으며 인근 광산부근에서는 중금속에 의한 오염이 나타나고 있었다. 10월 조사시에 인가가 밀집한 지역에서는 질산성 질소의 의한 오염 또한 높게 나타나는 특징을 보이고 있다. 이러한 자료를 토대로 군집분석(Cluster Analysis)과 주성분 분석(Principal Component Analysis)을 실시하였으며, 군집분석결과 지표수는 5개의 그룹으로 구분되었고 지하수는 3개의 그룹으로 구분되었다. 주성분분석 결과는 군집분석 시에 나타난 결과를 효과적으로 지지하고 있으며 (1)지질매체의 수리지화학적 반응, (2)오염물질의 유입 (3) 인근광산에 의한 중금속 오염이 복합적으로 반응하여 나타난 결과로 해석된다.

입상 활성탄 여과지에서 세균의 재성장과 생물막 형성 세균의 분리 및 동정 (Bacterial regrowth in biofilms formed in granular activated carbon filter adsorbers and the bacterial isolation and identification)

  • 이규철;권순복;이병기;박종근
    • 상하수도학회지
    • /
    • 제22권2호
    • /
    • pp.205-212
    • /
    • 2008
  • This study aimed to investigate the biofilm formation, bacterial regrowth, and bacterial community structure in the granular-activated carbon (GAC) filter adsorbers (FAs) used in water treatment plants. In 2005 and 2006, raw water, settled water, GAC FA by depth, and filtered water were collected twice a year from water treatment plants (WTPs) B and S. The number of heterotrophic bacteria, including mesophilic and psychrophilic bacteria, in such collected waters was investigated along with the total number of coliforms therein. Heterotrophic bacteria were detected in most samples, mainly at the surface layers of the GAC FAs, and fewer such bacteria were found in the lower and bottom layers. An increase in the bacterial number, however, was observed in the samples from various depths of the GAC FAs in WTPs B and S compared with the surface layers. An increase in the bacterial number was also detected in the filtered water. This may indicate that there is a regrowth of the bacteria in the GAC FA. Considering, however, that heterotrophic bacteria were not found in the filtered water, it can be deduced that most bacteria are removed in the chlorination process. Coliforms were detected at the surface layer of the GAC FAs, but their regrowth was not observed. MicroLog systems were used to identify the bacteria community distribution. Eight genera and 14 species, including Pseudomonas spp., were detected in WTP B, and 8 genera and 9 species, including Aeromonas spp., in WTP S. Further studies are required to elucidate their role in the biofilms in water treatment processes.

A Pesticide Residue Risk Assessment from Agricultural Land Using GIS

  • Lee, Ju-Young;Krishina, Ganeshy;Han, Moo-Young;Yang, Jung-Seok;Choi, Jae-Young
    • Environmental Engineering Research
    • /
    • 제13권3호
    • /
    • pp.107-111
    • /
    • 2008
  • Water quality contamination issues are of critical concern to human health, whilst pesticide release generated from irrigated land should be considered for protecting natural habitats and human health. This paper suggests new method for evaluation and analysis using the GIS technique based on integrated spatial modeling framework. The pesticide use on irrigated land is a subset of the larger spectrum of industrial chemicals used in modern society. The behavior of a pesticide is affected by the natural affinity of the chemical for one of four environmental compartments; solid matter, liquid, gaseous form, and biota. However, the major movements are a physical transport over the ground surface by rainfall-runoff and irrigation-runoff. The irrigated water carries out with the transporting sediments and makes contaminated water by pesticide. This paper focuses on risk impact identification and assessment using GIS technique. Also, generated data on pesticide residues on farmland and surface water through GIS simulation will be reflected to environmental research programs. Finally, this study indicates that GIS application is a beneficial tool for spatial pesticide impact analysis as well as environmental risk assessment.