• Title/Summary/Keyword: Water supply systems

Search Result 517, Processing Time 0.03 seconds

비상시 용수공급을 위한 상수도 연계관로의 수리적 적정성 평가 (Hydraulic Adequacy of Connection Pipes in Water Supply Systems for Contingencies)

  • 한완섭;정관수;김주환
    • 상하수도학회지
    • /
    • 제27권6호
    • /
    • pp.679-687
    • /
    • 2013
  • Although stable and safe drinking water supply to the customers is a basic function of multi-regional water supply systems in Korea, most systems have their vulnerabilities in emergency time due to the branch-type. Application of connections from the other water supply system can provide a solutions for these tentative problems. This paper describes reduction planning of water supply accidents that can minimize a service interruption to customers in multi-regional water supply system by connecting pipe lines between local water supply systems in Mokpo city areas. The result of this study shows that Juam dam multi-regional water supply systems can cover all of the water shortage in southern parts of Jeonnam multi-regional water supply systems by transmitting water through connected pipes between local networks. This can be effective to supply water interactively in various contingencies, when a pipe line accident occurs in southern area of Jeonnam multi-regional water supply systems. On the contrary, southern area of Jeonnam multi-regional water supply systems can cover 99.5 %($62,500m^3/day$) of the water shortage of Juam dam multi-regional water supply systems when service interruptions caused by various pipe accidents occur in the system.

물수요 중심 용수공급시스템 활용을 위한 국내 농업용수 공급체계 분석 (Analysis of Agricultural Water Distribution Systems for the Utilization of Water-Demand-Oriented Water Supply Systems)

  • 이광야;최경숙
    • Current Research on Agriculture and Life Sciences
    • /
    • 제31권2호
    • /
    • pp.139-147
    • /
    • 2013
  • This study analyzed agricultural water distribution systems for the utilization of water demand-oriented water supply systems. Three major TM/TC(telemeter/telecontrol) districts of agricultural water management were selected for analyzing the characteristics of the water distribution systems. In addition, the characteristics of the water supply systems for general water supply zones based on irrigation facilities were also investigated, along with the case of special water management during the drought season. As a result, high annual and monthly variations were observed for the water supply facilities, including the reservoirs and pumping stations. In particular, these variations were more obvious during the drought season, depending on the type of facility. The operations of the pumping stations and weirs were more sensitive to the stream levels than the reservoirs, and the smaller reservoirs were influenced more than the larger reservoirs. Therefore, a water-demand-oriented water supply system should consider the existing general practices of water management in the agricultural sector, and focus on achieving a laborsaving system rather than water conservation in the case of reservoirs. Equal water distribution from the start to the end point of irrigation channels could be an effective solution for managing pumping stations.

  • PDF

一部 農村 地域의 簡易 上水道와 Pump水의 季節別 水質에 關한 調査硏究 -춘성군 지성을 중심으로- (A Comparative Study on Drinking Water Quality of Simple Piped Water Supply Systems and Water Pumps According to Seasons)

  • Chung, Moon Ho
    • 한국환경보건학회지
    • /
    • 제10권1호
    • /
    • pp.21-31
    • /
    • 1984
  • The purpose of this study was to find out more effective schemes on safe water supply in rural area. Then, this study was carried out to investigate drinking water qualities of 20 simple piped water supply systems and 20 water pumps in Chun Sung County, Kang Won Province from 12th December to 24th December, 1983 and was compared this results with the previous results that had been carried out at the same sample sites from 1st July to 30th August, 1981. 1. This results of water quality in winter are better than the previous results in summer because this results are identified as safe 20%, unsafe 35% in simple piped water supply systems, safe 50%, unsafe 20% in water pumps and the previous results are identified as safe 1.8%, unsafe 78.6% in simple piped water supply systems, safe 5.5%, unsafe 73.6% in water pumps. 2. Water qualities of water pumps are better than that of simple piped water supply systems because the former is identified as safe 50%, unsafe 20% and the latter is identified as safe 20%, unsafe 35%. 3. Drinking waters that are in need of chlorination in winter as well as summer are 45% of simple piped water supply systems and 30% of water pumps.

  • PDF

장기 용수 공급계획 수립을 위한 스프레드 쉬트 모델 (A Spread Sheet Model for a Long Range Water Supply Planning)

  • 김승권
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 1992년도 수공학연구발표회논문집
    • /
    • pp.479-489
    • /
    • 1992
  • A mathematical model for a long range water supply planning is develoted as a dynamic capacitated facility location problem, in which operation costs and two types of fixed costs are considered. The fixed costs are for water supply systems such as dams and reservoirs and for water conveyance systems of waterways or conduits from each water supply points. A Spreadsheet model is developed to support the efficiency of user interface and to implement a heuristic solution procedure. The proposed solution procedure utilizes SOLVER tool and it has been applied to a system with fictitious data but with reality and applicability in mind. As a result of the mathematical analysis, not only the most economic construction timings of surface water supply facilities and distribution systems but also the most economical water supply operating patterns are identified.

  • PDF

광역상수도 시설의 비상시 의사결정을 위한 전문가시스템 (Expert System for Emergency Decision Making for Metro Water Supply Systems)

  • 김응석;김중훈;백천우;이정호
    • 한국물환경학회지
    • /
    • 제23권1호
    • /
    • pp.103-110
    • /
    • 2007
  • An efficient operational strategy using expert system for metro water supply systems in case of emergency situations is developed in this study. The emergency situations of the water supply systems are classified into three categories : pipeline system accident, machinery and electric facility accident and water quality accident. A PC-based expert system is developed using CLIPS for Seoul metro water supply system, Phase 1 & 2 system and Phase 3 & 4 system. Broad professional knowledges and experiences from the experts in the water supply systems have been collected systematically to construct the knowledge base. Decision-making in case of an emergency is based upon the professional knowledge so that a rational and efficient operational management can be available even in the absence of experienced expert. Especially the expert model developed in this study also provides a guide for pumping operation in case of pipeline accident to confirm that the proper pressure to all nodes in the system is supplied. The pipe network simulator KYPIPE has been consecutively executed by trial and error fashion for each pipeline in the system. The results from KYPIPE were included in the knowledge base to supplement the knowledge of the field engineers.

SWMM 모형을 활용한 평야부 관개효율 및 용수공급 취약성 평가 (Assessment of Irrigation Efficiency and Water Supply Vulnerability Using SWMM)

  • 신지현;남원호;방나경;김한중;안현욱;이광야
    • 한국농공학회논문집
    • /
    • 제62권6호
    • /
    • pp.73-83
    • /
    • 2020
  • Agricultural drought is a natural phenomenon that is difficult to observe and quantitatively express, and agricultural water use is high and usage patterns are diverse, so even if there is a lack of rainfall. The frequency and severity of agricultural drought are increased during the irrigation period where the demand for agricultural water is generated, and reasonable and efficient management of agricultural water for stable water supply is required. As one method to solve the water shortage of agricultural water in an unstructured method, it is necessary to analyze the appropriate supply amount and supply method through simulation from the intake works to the canals organization and paddy field. In this study, irrigation efficiency was analyzed for irrigation systems from April to September over the past three years from the Musu Reservoir located in Jincheon-gun, Chungcheongbuk-do and Pungjeon Reservoir located in Seosan-si, Chungcheongnam-do. SWMM (Storm Water Management Model) was used to collect agricultural water, and irrigation efficiency analysis was conducted using adequacy indicators, and water supply vulnerability. The results of the agricultural water distribution simulation, irrigation efficiency and water supply vulnerability assessment are thought to help the overall understanding of the agricultural water supply and the efficient water management through preliminary analysis of the methods of agricultural water supply in case of drought events.

상하수도시설에 대한 전과정관리(LCM)시스템 구축방안 연구 (Establishment of Life Cycle Management(LCM) System for Water Supply and Sewerage Systems)

  • 박지형;황용우;김영운;박광호
    • 상하수도학회지
    • /
    • 제26권2호
    • /
    • pp.303-312
    • /
    • 2012
  • Water supply and sewerage systems are the large-scale urban infrastructure ejecting large amount of environmental load over the life-cycle. Therefore, it is important not only to optimize in the aspect of economical superiority and process efficiency but also to consider earth scale environmental impact. This study aimed to suggest the establishment of life cycle management(LCM) system as an integrated management solution in urban water supply and sewerage systems. As a result, the methodology for LCM system consisting of life cycle assessment(LCA), life cycle cost(LCC), life cycle $CO_{2}(LCCO_{2})$ and life cycle energy(LCE) was developed. Also, several case studies using the latest statistics data of water supply and sewerage systems were carried out to investigate the field applicability of LCM.

급수배관방식에 따른 욕실 위생기구의 유량분석에 관한 연구 (A Study on the Flow rate Analysis of a Sanitary Fixture for Water Supply Piping System)

  • 장영근;김덕주;서병택
    • 한국기계기술학회지
    • /
    • 제13권4호
    • /
    • pp.9-14
    • /
    • 2011
  • The flow rate analysis for sanitary fixtures has been studied to determine the water supply piping system and size. The study has been carried out to analyze for a various water supply pressure and piping size theoretically. Also, the study has been carried out to analyze for a various water supply piping system experimentally. The water supply pressure is varied from 0.01MPa to 0.07MPa, and the piping size is varied from 6mm to 15mm. The water supply piping systems are one-to-one, all-loop-type, and bathroom-loop-type water supply piping system. The results indicate that the piping size is able to supply water fully in case of smaller than 15mm if the water supply pressure keep an necessary minimum pressure. And the gap of flow rate is very little for the various water supply piping systems.

수리해석(水理解析) 모형(模型)을 이용한 다수원(多水源) 송수계통(送水系統)의 연계(連繫) 운영(運營) 방안(方案) 경제성(經濟性) 평가(評價) - 거제시(市)를 대상(對象)으로 - (Feasibility Study on the Conjunctive Operation of Water Transmission Systems from Multiple Source with Applying EPAnet)

  • 류태상;하성룡
    • 상하수도학회지
    • /
    • 제21권5호
    • /
    • pp.609-619
    • /
    • 2007
  • The objective of this paper is to evaluate the feasibility of conjunctive Operation between Multi-regional water supply networks from multiple source as a effective way to meet two conditions: to minimize the electric cost for providing water demanded and meet the water flow rate for satisfying customers. EPAnet Model is used to calculate a hydraulic water distribution condition based on an integrated operation of water supply systems located in short distance. The modeling was conducted on several simulation cases including the individual operation by existing inter-regional water supply networks within short distance, the conjunctive operation of more than two existing networks with valve fully closed and full open constraint. As a study distribution system, water supplying systems of the Geojae-city in the Geongsang Namdo Province was selected and investigated. It was found that a well-allocated water supply scheme based on a conjunctive operation promises to save the electric cost and satisfy all operational goals such as stability and revenues during the period. The result such as unit district costs, pareto optimum pump combination sets will be applied to the optimization for a conjunctive operation of existing inter-regional water supply networks within short distance.

상수도 시스템의 운영 및 유지관리 의사결정 지원을 위한 시스템다이내믹스 모형의 개발 (Development of a System Dynamics Model to Support the Decision Making Processes in the Operation and Management of Water Supply Systems)

  • 박수완;김규리;김봉재;임기영
    • 한국수자원학회논문집
    • /
    • 제43권7호
    • /
    • pp.609-623
    • /
    • 2010
  • 본 논문에서는 시스템다이내믹스(System Dynamics, SD) 방법론에 입각하여 상수도 시스템의 운영에 내재된 피드백 루프 메커니즘(feedback loop mechanism)을 상수관로의 유지관리와 연관하여 규명하고, 관로 상태의 변화가 전체 시스템에 미치는 영향을포함한 상수도 시스템의 운영지표를예측하여 상수도 시스템의 효율적인운영 및 유지관리를 지원할 수 있는 SD 컴퓨터 모의 모형(simulation model)을 개발하였다. 개발된 모형은 물 공급(water supply) 모형, 관로 유지 관리(pipe maintenance) 모형 및 상수도 재정(water supply business finance) 모형으로 구성된다. 연구대상 지역 상수도 시스템의 운영 자료를 개발된 모형에 적용하여 모형을 검증하고 시스템의 과거 및 미래의 운영 상태를 추정하였으며, 시스템의 운영에 큰 영향을 미치는 정책 지렛대를 발견하였다. 정책 지렛대 발견을 위해 모형의 외부변수의 변화에 대한 연구대상 시스템의 주요 운영지표의 민감도가 분석되었는데 관로의 유지관리에 연관된 외부변수는 누수수량과 관로의 변화에는 큰 영향을 끼치나, 유수율을 비롯한 주요 운영지표에는 큰 영향을 미치지 않는 것으로 나타났다. 관로의 유지관리와 유수율과 같은 주요 운영지표 간의 관계를 보다 정확히 모형화하기 위해서는 관로의 누수 또는 사고로 인해 발생하는 사회적 비용의 발생과 그 전파 메카니즘이 모형화되어야 할 것으로 분석된다.