• 제목/요약/키워드: Water storage volume

검색결과 269건 처리시간 0.024초

태양열 급탕 난방 복합 축열조 열성능 (Thermal Performance of Solar Hot Water and Space Heating in a Combi - Storage Tank)

  • 곽희열;주홍진
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2009년도 춘계학술대회 논문집
    • /
    • pp.266-269
    • /
    • 2009
  • The Purpose of this study was thermal performance of solar hot water and space heating thermal storage tank. The combi storage tank was designed Tank in Tank type. The tank volume for space heating was 700 $\ell $ and tank volume for hot water was 150 $\ell $. Tank in Tank type storage tank was to replace heat exchange to hot water tank. The result showed that the Heating value was 67.25MJ and domestic hot water value was 51.93MJ. Supply to the hot water volume was 521 $\ell $ more than about 3 times as that of the hot water tank volume.

  • PDF

저수형 잔디블록 저수조 내 충진재료에 따른 저수량 및 초종별 증발산량 (Volume of Water Storage and Evapotranspiration by Inserted Materials at a Reservoir of Porous Grass Block)

  • 한승호;최준수;양근모;양병이;강진형;김원태
    • 한국조경학회지
    • /
    • 제34권5호
    • /
    • pp.76-83
    • /
    • 2006
  • The purpose of this study was to investigate the performance of porous grass block. For the investigation, Festuca arundinacea and Zoysia japonica 'Zenith' were planted, and the volume of evapotranspiration and remains were examined based on different materials in the water tank in the experiment of Festuca arundinacea, the volume of water storage of treatment with perlite ($10.84{\iota}/m^2$) was higher than that with drainage ($7l/m^2$). The difference between the two was $3.84/m^2$. The drainage treatment without water storage capacity showed the higher degree of dryness in turf grass. The volume of evapo-transpiration of treatment with perlite was the highest (21.57mm/week). The volume of evapotranspiration of treatment with sand was 19.57mm/week, and with treatment with drainage was 18.24mm/week. Based on the measured volume of daily evapotranspiration of $2.60{\sim}3.08mm\;d^{-1}$, it was determined that the unit with water storage capacity would store water of one to two days usage compared to unite without such storage capacity. In the experiment of Zoysia japonica 'Zenith', the volume of water storage of treatment with perlite was $10.77l/m^2$ which was similar to the former experiment. The volume of evapotranspiration of treatment with perlite and sand were 21.64mm/week and 20.64mm/week, respectively. In case of airtight water tank, the volume was measured as 22.06mm/week. Each treatment has no notable difference in the volume of evapotranspiration. In conclusion, from the investigation in this study, porous grass block with water tank was found to be effective in plant growth under low irrigation. As the ecological area ratio and vegetated porous pavement have became more emphasized, additional study of rain infiltration and reservoir effect are needed in the future.

친환경 도시에서의 자원활용에 관한 연구 -빗물의 다목적 활용을 위한 빗물저장조의 운전방법 - (Study on Utilizing Resources in Environment-friendly City - Operation method of rain storage tank for using rainwater as multipurpose -)

  • 정용현
    • 한국환경과학회지
    • /
    • 제12권3호
    • /
    • pp.359-366
    • /
    • 2003
  • Ecological society and energy conservative systems has become a subject of world wide attention. To examine the technologies of such systems as resource recycling society, this study is proposed for using rainwater as energy source and water resources in urban area. Useful informations for planning of utilizing rainfall as energy source, water resources, emergency water and controlling flood are discussed with model systems in urban area. It is calculated that the rate of utilizing rainwater, amounts of utilizing rainwater, substitution rate of supply water, amounts of overflow rainwater according to rain storage tank volume. By applying the past weather data, The optimum volume of rain water storage was calculated as 200m$^3$ which mean no benefits according to the increase of storage tank volumes. For optimum planing and control method at the model system, several running method of rainwater storage tank was calculated. The optimum operating method was the using weather data as 3hours weather forecast.

도심지 소유역에 적용 가능한 우수저류조의 용량 산정에 관한 연구 (A Study on the Calculation of Storage Volume of Storm-Water Detention Basins for Small Urban Catchments)

  • 김대근;고영찬
    • 상하수도학회지
    • /
    • 제19권5호
    • /
    • pp.619-624
    • /
    • 2005
  • This work is for examining a simplified equation based on the rational formula, which can easily decide storm-water detention volume in small urban catchments. The storm-water detention volume is determined by the inflow hydrograph flowing to detention basin and the outflow hydrograph discharged from the detention basin. The ratio of average outflow over the period of rainfall duration against allowable discharge was 0.5 in former simplified equation. But this research has found that the average outflow ratio depends on the storage methodology. In the case of the on-line storage method, the average outflow ratio is a function of the time of concentration of the catchments and rainfall duration, which ranged from 0.5~1.0. In the case of the off-line storage method, the average ratio is a function of peak discharge and allowable discharge except above time of concentration and rainfall duration, where its function value ranged from 1.0~2.0. When applying this equation to small catchment in Mokpo city, South Korea, we could easily calculate the relation curve between the storm-water detention volume and allowable discharge.

단지계획지구 홍수저류지의 하천유지유량 공급방안 연구 (A Feasibility Study on Supplying Stream Minimum Flow Using Detention Storage in Developing Planned District)

  • 노재경;박현구
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 2005년도 학술발표회 논문집
    • /
    • pp.1219-1223
    • /
    • 2005
  • This study was accomplished to confirm the possibility of supplying stream minimum flow from detention storage which was determined to reduce peak flows of flood within developing planned district. The results analyzed was summarized as follows; Firstly, Sin-gil district situated in Ansan city was selected, of which watershed area has $0.56km^2$. And detention storage was determined to $5,370m^3$ from analyzing flood volume by the SCS unit hydrograph method. Secondly, using Visual Basic ver 6.0, a detention storage water balance model was developed, in which simulation was based on conditioning storage inflow and outflow according to streamflow volume or rate state. And streamflow was simulated using the DAWAST model. Thirdly, detention operation scenarios were consisted of the combinations with inflow referencing streamflow of 5mm/day, 10mm/day and outflow referencing streamflow of 1mm/day, 2mm/day. The developed detention storage water balance model was operated to simulate daily water storages of detention sized on flood by scenarios. Stream minimum flows were able to be supplied during 209 days to 237 days per a year, total volume of stream minimum flows supplied for this period was analyzed to reach 27 to $55\% of yearly streamflow volume. If inflow criteria of streamflows to detention was considered to be established on a theoretical condition, it is expected to supply stream minimum flows of 20 to $30\% of yearly streamflow from stream to detention. Also to maximize function of supplying urban stream minimum flow from detention storages, sewage waters within developing planned district have to be treated and entered to detention inflow together with streamflows to enrich function of detention planned to reduce flood volumes.

  • PDF

덕동호 유해남조류 출현 특성 및 환경요인 영향 분석 (Analysis of Harmful Cyanobacteria Occurrence Characteristics and Effects of Environmental Factors)

  • 홍동균;박혜경;김용진
    • 한국물환경학회지
    • /
    • 제39권1호
    • /
    • pp.20-29
    • /
    • 2023
  • This study analyzed the relationship between harmful cyanobacterial abundance and environmental factors in order to figure out the causes of the recent increase of cyanobacteria in Lake Dukdong from 2019 to 2021. Lake Dukdong, which is used as a drinking water source for Gyeongju City, has an algae alert system in place. Lake Dukdong has maintained good water quality, but algae alert level 1 (over 1,000 cells/mL) has been issued in recent years. As a result of Pearson correlation analysis (from May to Oct.), the cell density of Microcystis and Aphanizomenon, which form part of the most harmful cyanobacteria genus, were significantly positively correlated with the water temperature and water storage volume. T-test was performed to compare the data from 2016-2018 and 2019-2021 (from May to Oct.). The average density of harmful cyanobacteria cells increased about six-fold from 54 to 344 cells/mL. There were significant differences in water temperature, pH, total nitrogen (TN), total phosphorus (TP), TN/TP ratio, water storage volume, and cyanobacterial cell density. Water temperature increased from 19.2 to 22.8 ℃. TP concentration increased from 0.017 to 0.028 mg/L. The main cause of the recent increase of harmful cyanobacteria in Lake Dukdong is thought to be the increase in water temperature, TP concentration, and water storage volume from 2019 and 2021, resulting in more favorable conditions for cyanobacterial growth.

사대강유역의 지하수 (Ground water in the four major basins in Korea)

  • 최승일
    • 물과 미래
    • /
    • 제12권1호
    • /
    • pp.21-27
    • /
    • 1979
  • Ground water stored in the alluvium and the rocks provides the vase flow of the streams and can be withdraw from wells and infiltration galleries. And it is also recharge naturallyby precipitation. The amount of ground water in the four major basins it is estimated to be about 137,000 million cubiv meters(Table1), while nationwide ground water storage to be about 232,000 million cubic meters. The estimation of storage volume has been made on the basis of assumed thickness of the saturated zone of the different rocks and assumed porosities of those rocks. The values of the porosity of alluvium and saprolite were assumed to be 25% and 40% respectivvely which are based on tests made of similar materials in Georgia, U.S. The volume of water in storage is believed to be a conservative estimate. Detailed geologic and hydrologic investigation should be made where and when water resources are needed.

  • PDF

도시지역 CSOs 저감을 위한 저류조 및 이송관로의 최적 용량결정에 관한 연구 (Study on the determination of optimum size of storage tank and intercepting capacity for CSOs reduction in urban area)

  • 이관용;최원석;이용재;구원석;송창수
    • 상하수도학회지
    • /
    • 제26권6호
    • /
    • pp.735-745
    • /
    • 2012
  • Storage method is one of major measures for reduction of CSOs pollutant loads and several projects have been done nationwide. But systematic analysis of intercepting capacity has not been studied to determine optimum size of storage facility. In this research, not only storage volume but also intercepting capacity which means flow capacity from intercepting facility to CSOs storage facility was studied and optimum sizing method for storage facility was proposed. The result shows that pollutants reduction efficiency can be increased significantly by increasing intercepting capacity and it might reduce storage volume and total construction costs. Intercepting capacity for the study area was evaluated and it was shown as equivalent to 83 % probability rainfall intensity.

Novel methods of increasing the storage volume at Pumped Storage Power plants

  • Storli, Pal-Tore
    • International Journal of Fluid Machinery and Systems
    • /
    • 제10권3호
    • /
    • pp.209-217
    • /
    • 2017
  • The paper presents two novel concepts of increasing the energy storage capacity at pumped storage power plants, both existing and new projects. The concepts utilize compressed air as a working medium to displace water from a volume originally not available for storage. The concepts are likely to give additional storage volume at a low cost, however, much development and many investigations are needed before the concepts can be shown to be technical and economical feasible solutions for energy storage. The concepts are disclosed so that researchers and utilities can start those investigations, hopefully helping the green transition by providing highly valuable energy storage for a future renewable energy having a much higher share of renewable energies than the current systems.

우리나라 관개용 흙댐 저수지의 외형적 제특성에 관한 연구 (A Study on the Physical Characteristics of Irrigation Reservoirs in Korea)

  • 정두희;안병기
    • 한국농공학회지
    • /
    • 제25권4호
    • /
    • pp.29-37
    • /
    • 1983
  • This study was carried out not only to prepare available materials that can be utilized in basic planning of irrigation reservoirs, but also to contribute to the study on countermeasures for reasonable irrigation water development in Korea in the future, through the investigation for the structural characteristics of reservoirs and their change trend by an epoch. During this study 123 sites of sample reservoirs were analysed in their dimensions of physical constituent factors. The physical characteristics and their change trends revealed by this study are summarized as follows: 1. For the irrigation earth dam in Korea the correlation between dam volume (v) and dam height & length (H$^2$L) can be described as the formula of v=1. 434H2L~17, 300 (r=0. 933), from which embankment amount is assumed to be quickly estimated under determined dam height and length of the proposed reservoir. 2. The ratio of dam volume to dam height & length ranges approximately from 0.5 to 3 (1.7 in average), that of storage capacity to dam volume 2 to 10 (8.4 in average), that of irrigation area to full water surface area 5 to 20 (13 in average) and that of catchment area to irrigation area 2 to 5 (4 in average). Though correlation between dam volume and dam height & length is high, that between others is relatively low. 3. Average storage depth ranges approximately from 4m to l0m (6.6m in average), unit storage capacity 0. 4m to 0. 8m (0.54 in average) and shape factor of dam 5 to 20 (10.5 in average). 4. The more recently planned the reservoirs were, the less storage capacity, dam volume, full water surface and dam shape factor they have. 5. The more recently planned the reservoirs were, the larger storage depth and unit storage capacity they have.

  • PDF