• 제목/요약/키워드: Water sensitive paper

검색결과 135건 처리시간 0.023초

Al 7075-T651의 부식피로균열 성장 거동에 관한 연구(II) (A Study on Corrosion Fatigue Crack Growth Behavior in Al 7075-T651(II))

  • 한지원;우흥식
    • 한국안전학회지
    • /
    • 제14권2호
    • /
    • pp.3-10
    • /
    • 1999
  • Fatigue crack growth rates in commercial plate of high strength Al 7075-T651 were investigated for the T-L direction in air, water and sea water. In this paper the effect of cyclic load wave-form(trapezoid and triangle) on fatigue crack growth rates in air, water and sea water environments were investigated using standard LEFM testing procedures. It was founded that the fatigue crack growth behaviors were not affected by cyclic load wave-forms. In region II (stable crack growth region), the fatigue crack growth behaviors were insensitive to cyclic load wave-forms and were sensitive to environment i.e. fatigue crack growth behaviors were higher in sea water than in air for all cyclic load wave-form. The result of fractographical morphology in air, water and sea water by SEM showed obvious dimple rupture and typical striation in air, but transgranular fracture surface in water and sea water. The values m are not affected by corrosion environments but C are different values.

  • PDF

실리카겔-물계 흡착식 냉동기 사이클 시뮬레이션 (Cycle Simulation of an Adsorption Chiller Using Silica Gel-water)

  • 권오경;윤재호
    • 대한기계학회논문집B
    • /
    • 제31권2호
    • /
    • pp.116-124
    • /
    • 2007
  • An adsorption chiller is expected to have high energy-efficiency in utilizing the waste heat exhausted from a process. The objective of this paper is to investigate the performance of silica gel-water adsorption chiller from the cycle simulation and to provide a guideline for design of the adsorption chiller. The effect of cycle time, inlet temperature and water flow rate on the cooling capacity and COP is quantified during the cycle operation. It is found that the performance of adsorption chiller is more sensitive to the change of inlet water temperature rather than the water flow rate. It is concluded that the COP is 0.57 in the standard conditions(hot water $80^{\circ}C$, cooling water $30^{\circ}C$, chilled water inlet temperatures $14^{\circ}C$ and cycle time 420sec).

다층신경망을 이용한 드론 방제의 살포 균일도 예측 (Predicting the spray uniformity of pest control drone using multi-layer perceptron)

  • 성백겸;강승우;조수현;한웅철;유승화;이춘구;강영호;이대현
    • 드라이브 ㆍ 컨트롤
    • /
    • 제20권3호
    • /
    • pp.25-34
    • /
    • 2023
  • In this study, we conducted a research on optimizing the spraying performance of agricultural drones and predicted the spraying performance in various flight conditions using the multi-layer perceptron (MLP). Data was collected using a test device for pesticide spraying performance according to the water sensitive paper (WSP) evaluation. MLP training involved supervised learning to achieve a coefficient of variation (CV), which indicates the degree of uniform spraying. The performance evaluation was conducted using R-squared (R2), the test samples showed an R2 of 0.80. The results of this study showed that drone spraying performance can be predicted under various flight environments. In addition, the correlation analysis between flight conditions and predicted spraying performance will be useful for further research on optimizing the spraying performance of agricultural drones.

복숭아혹진딧물, Myzus persicae (Sulzer)(Insecta: Hemoptera: Aphididae), 살진딧물 최적 in vitro 살충력 검정 방법 확립 (An Optimal Standardized in vitro Bioassay to Evaluate Susceptibility of Green Peach Aphid, Myzus persicae (Sulzer)(Insecta: Hemoptera: Aphididae), to Aphicides)

  • 조가희;김효정;김영철
    • 한국응용곤충학회지
    • /
    • 제62권3호
    • /
    • pp.139-147
    • /
    • 2023
  • 진딧물 방제제 개발을 위해 In vitro 경엽살포 검정방법이 널리 사용되고 있다. 이러한 신소재 진딧물 방제 제형은 종합방제와 화학농약의 대안으로 많은 연구가 진행되고 있다. 하지만, 경엽살포 검정방법은 환경이 조절되는 실내에서도 진딧물의 증식과 살충에 영향을 받는다. 본 연구에서는 담배를 기주로 하여 솜과 한천방법을 이용하여 진딧물 방제제 검정을 위한 최적 경엽살포 확립하고자 하였다. 진딧물 검정 챔버에 솜과 한천을 넣은 후 담배 잎과 진딧물 3-4령 약충을 접종하였다. Water-sensitive paper를 이용하여 경엽살포 시에 가장 표면 피복이 높은 최적 경엽살포 거리와 살포량을 확립하였다. 대조구로 물을 처리한 구에서 한천 방법이 솜 방법에 비해 살충율이 낮고, 증식율이 높았다. 솜 검정 방법에는 곤충 검정 챔버의 상대습도를 60% 이상 유지시켰을 때 가장 최적 조건이었지만, 한천 검정 방법에서는 한천의 농도에 상대습도 차이가 없었다. 최적화된 조건하에서 대조화학 농약, Sulfoxaflor, 경엽살포 시 솜 방법에서 살충율이 한천방법보다 빨랐지만, 최종 살충율은 통계적으로 유의하지 않았다. 본 연구는 살진딧물 물질을 검정 시 재현성과 활용성이 가능한 최적화된 증식율과 살충율 검정 조건을 제시하였다.

Experimental study on Green Water in Regular Waves

  • Han, Ju-Chull;Lee, Seung-Keun;Lee, Gyoung-Woo
    • 한국항해항만학회지
    • /
    • 제28권7호
    • /
    • pp.647-651
    • /
    • 2004
  • FPSOs are commonly proposed and used for offshore oil production. Due to the fundamental requirement of FPSOs to remain moored at their location, they are unable to avoid severe weather. FPSOs normally operate head to the weather, and sensitive equipment located near the bow will be susceptible to green water damage. Damage may occur to both equipment and superstructure, with resulting risk to personnel. To initially access green water is allowed by the physical understanding of green water events. In this paper the main focus is put on the physical phenomena of green water accounted for with the tested data in regular waves.

Direct Detection of Water-dissolved Ammonia Using Paper-based Analytical Devices

  • Yeong Beom Cho;Duc Cuong Nguyen;Si Hiep Hua;Yong Shin Kim
    • 센서학회지
    • /
    • 제32권2호
    • /
    • pp.67-74
    • /
    • 2023
  • A microfluidic paper-based analytical device (µPAD) is proposed for the selective detection of ammonia in water by using the modified Berthelot reagent and a fluidic channel consisting of hollow paper. The modified Berthelot reagents were uniformly dispersed in cyclohexane and then immobilized in a detection zone of the µPAD. The loading position of the reagents and the type of a sample flow channel were optimized to achieve a sensitive ammonia detection within a short analytical time. The NH3 µPAD exhibits a linear colorimetric response to the concentration of ammonia dissolved in water in the range of 1-100 mg L-1, and its limit-of-detection is 1.75 mg L-1. In addition, the colorimetric response was not influenced by the addition of 100 mg L-1 nitrogen containing compounds (sodium nitrate, sodium nitrite, uric acid, hydroxylamine, butylamine, diethylamine) or inorganic salts (NaCl, Na2HPO4), presenting the enough selectivity in the detection of water-dissolved ammonia against possible interferents.

FPSO - Green Water Protector 구조 최적 설계 (The Optimum Design of Green Water Protector for FPSO)

  • 배명현;김성준;문중용
    • 대한조선학회 특별논문집
    • /
    • 대한조선학회 2007년도 특별논문집
    • /
    • pp.94-98
    • /
    • 2007
  • The latest development of the submarine oil field and the deep-sea explorer, FPSO is commonly proposed and used for offshore oil production. And because the fundamental requirement of FPSOs to remain moored at their position, they are unable to avoid severe weather and environment. FPSO normally operates head to the weather, and sensitive equipment located the exposed area will be influenced by green water damages, the damages may occur to both onboard equipment and topside structures with resulting risk to personnel. In this paper, the main focus considers the physical structures of green water protector in order to preserve topside structures, equipment and personnel from green water.

  • PDF

Real-time Spectroscopic Methods for Analysis of Organic Compounds in Water

  • Kim, Chihoon;Ji, Taeksoo
    • Current Optics and Photonics
    • /
    • 제3권4호
    • /
    • pp.336-341
    • /
    • 2019
  • This paper proposes an optical system where the organic compound content in water is determined by using an ultraviolet (UV) LED (280 nm) and photodetector. The results obtained by the proposed prototype LED spectroscopy system, which includes a single photodetector and two parallel sample holders, are calculated by applying partial least square regression; the values are highly correlated with the actual concentrations of potassium hydrogen phthalate solutions, with an adjusted coefficient of determination about 0.996. Moreover, the total organic carbon values derived from the UV-Vis spectrometer of real samples (lake, river and sea water) differed little from those obtained by the LED spectroscopy. We confirm that the fast, sensitive, and compact LED sensor system can be readily configured for real-time monitoring of organic compounds in water.

Design and control of extractive distillation for the separation of methyl acetate-methanol-water

  • Wang, Honghai;Ji, Pengyu;Cao, Huibin;Su, Weiyi;Li, Chunli
    • Korean Journal of Chemical Engineering
    • /
    • 제35권12호
    • /
    • pp.2336-2347
    • /
    • 2018
  • The azeotrope of methyl acetate methanol and water was isolated using extractive distillation with water as entrainer. The pressure-swing extractive distillation (PSED) process and vapor side-stream distillation column (VSDC) with the rectifier process were designed to separate the methyl acetate, methanol and water mixture. It was revealed that the VSDC with the rectifier process had a reduction in energy consumption than the PSED process. Four control schemes of the two process were investigated: Double temperature control scheme (CS1), $Q_R/F$ feedforward control of reboiler duty scheme for PESD (CS2), $Q_R/F$ feedback control scheme for VSDC (CS3), the feedback control scheme of sensitive plate temperature of side-drawing distillation column to dominate the compressor shaft speed (CS4). Feed flow and composition disturbance were used to evaluate the dynamic performance. As a result, CS4 is a preferable choice for separation of methyl acetate-methanol-water mixture. A control scheme combining the operating parameters of dynamic equipment with the control indicators of static equipment was proposed in this paper. It means using the sensitive plate temperature of side-drawing column to control the compressor shaft speed. This is a new control scheme for extractive distillation.

흡수식 냉온수기의 부분부하에 따른 냉각수 변유량시 성능특성에 관한 연구 (A Study on the Performance Characteristics of an Absorption Chiller for Variable Cooling Water Flow Rate at Partial Load Conditions)

  • 박찬우;조현철;강용태
    • 설비공학논문집
    • /
    • 제16권1호
    • /
    • pp.26-33
    • /
    • 2004
  • In general, an absorption chiller or heat pump is operated under the constant cooling water flow rate condition even though the system works with a partial load. The objective of this paper is to study the effect of the cooling water flow rates and the temperature of cooling water on the system performance to find the energy saving methode for the partial load operation of the double effect $H_2O$/LiBr absorption chiller. It is found that the performance of the system is sensitive to the temperature of cooling water than the cooling water flow rate, so the decrease of the performance due to reducing the cooling water flow rate can be overcome with the reduction of the cooling water temperature by 1$^{\circ}C$. The flow rate of the cooling water flow rate ranges from 50% to 100% of the flow rate at normal conditions with a partial load. It is also found that the operation cost of the cooling water pump and the cooling tower can be reduced by 23%.