Problems and Control Measures of Industrial Cooling Water (공업용 냉각수의 문제점과 처리법)

  • Bae, Jong-Su;Lee, Gyu-Hwa
    • 한국기계연구소 소보
    • /
    • s.16
    • /
    • pp.117-126
    • /
    • 1986
  • Trouble-free operation of cooling water systems is essential for efficient pro¬duction in most industrial facilities. Improper water treatments frequently cause such problems as corrosion, scaling, fouling and slime formation. Water quality, methods of cooling and materials of construction in the cooling circuit should be carefully studied before making selection of the water treatment programs. This paper reviewed cooling water problems encountered frequently in the open recirculating cooling systems and discussed the counter measures how to cope with them.

  • PDF

A Study of CaSO4 Scale Formation and Heat Transfer in a Vertical Tube Evaporator (수직 증발관에서 CaSO4 Scale 형성과 열전달에 관한 연구)

  • Hong, Choonkeun;Choi, Mansoo
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.23 no.11
    • /
    • pp.1363-1370
    • /
    • 1999
  • A study of scaling and heat transfer has been carried out for a vertical tube evaporator in which $CaSO_4$ saturated water flows upward. Experimental apparatus including vacuum chambers and heaters has been designed and manufactured to study scaling phenomena for three different pressures(1atm, 0.27atm and 0.16atm). Overall heat transfer coefficients have been measured and shown to decrease with time as scaling proceeds. After the end of experiments, the vertical tube has been cut to measure the thickness of scale at different heights. Below the height where the bulk fluid temperature does not reach saturated temperature, the thickness of scale increases, however, beyond that height occurring saturated condition, the thickness does not vary much or even decreases a little. The measured fouling resistances also support these variations of scale thickness.

Scaling Deterioration of Concrete due to Deicing Salt (동결방지제에 의한 콘크리트의 스케일링 열화)

  • Kim, Gyu-Yong;Park, Chan-Kyu;Kim, Han-Jun;Sohn, Yu-Shin;Lee, Seung-Hoon
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2005.05b
    • /
    • pp.177-180
    • /
    • 2005
  • Decing agent with chloride promote frost damage of concrete structure in winter period. From the safetyside, however, it is difficult to stop using chloride. Therefore, the durable concrete is required from now on. In this paper, long-term freezing and thawing test was carried out using the freezing water containing $CaCl_{2}$ to consider the concrete scaling according to the kind of binders, such as OPC, Flyash, Slag+Fa. and Slag As a result, it was found that the degree of scaling is different with containing slag being considered to prevent the penetration chloride ion and according to each binders.

  • PDF

Comparison of Rainfall Quantile using At-site Frequency Analysis and Scale Invariance Property (빈도해석과 스케일 성질을 이용한 확률강우량의 비교)

  • Jung, Young-Hun;Kim, Soo-Young;Kim, Tae-Soon;Heo, Jun-Haeng
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2008.05a
    • /
    • pp.164-168
    • /
    • 2008
  • 일반적으로 확률강우량은 관측지점에서 관측된 연최대 강우량자료를 바탕으로 빈도해석을 적용하여 산정한다. 그러나 국내에서는 매시각별로 관측된 자료가 대부분이기 때문에 단기간 혹은 장기간의 지속기간에 대한 확률강우량을 산정하는 것은 쉽지 않다. 따라서 본 연구에서는 매시각단위의 지속기간 강우자료를 바탕으로 다양한 지속기간에 대한 확률 강우량을 산정할 수 있는 스케일 성질을 적용하여 확률강우량을 산정하여 정확성을 판단하였다. 강우자료는 비교적 신뢰성이 높고 자료기간이 긴 기상청 지점 22개 자료를 사용하였으며, 2003년까지의 관측된 자료를 이용하여 확률강우량을 산정한 후 지점빈도해석 프로그램인 FARD2006과 비교하여 지점빈도해석의 결과 값을 참값으로 절대상대오차를 산정하여 비교하였다. 산정한 방법은 기준이 되는 확률강우량을 산정한 후 그보다 긴 지속기간에 대한 확률강우량을 산정하는 방법인 상향스케일링 (Up-scaling)과 그 보다 짧은 지속기간에 대한 확률강우량을 산정하는 방법인 하향스케일링(Down-scaling)의 두 가지 방법으로 확률강우량을 산정하였다. 두 방법 모두 1시간$\sim$24시간의 지속기간에 대한 확률강우량을 2년$\sim$500년의 재현기간에 대하여 확률강우량을 산정하였으며, 빈도해석으로 산정한 FARD2006의 결과값과 비교하여 절대상대오차를 산정하였다. 그 결과, 시간단위자료를 사용할 경우 대부분 절대상대오차가 10% 미만인 결과를 얻을 수 있었으며, 14개의 재현기간 중에서 8개 이상의 재현기간에 대해 적용이 가능한 것으로 나타났다. 지속기간 1시간 강우자료를 기준 지속기간으로 1시간 미만의 지속기간에 대한 확률강우량을 추정한 결과 10분을 제외하고는 대부분 절대상대오차가 10% 내외의 정확도를 가지는 것으로 나타났다. 따라서 스케일 성질을 이용하여 미계측 강우지속기간의 확률강우량을 추정할 수 있을 것으로 판단된다.

  • PDF

The Effects of Climate Change on Rainfall Quantile in Han River Basin Based on Scaling Invariance and NSRPM (Scaling invariance와 NSRPM을 이용한 기후변화에 따른 한강유역의 확률강우량 추정)

  • Nam, Woo-Sung;Um, Myoung-Jin;Shin, Ju-Young;Joo, Kyung-Won;Heo, Jun-Haeng
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2011.05a
    • /
    • pp.68-72
    • /
    • 2011
  • 전세계적으로 기상이변이 빈번하게 발생하면서 기후변화가 수문환경에 미치는 영향에 대한 연구가 활발히 진행되고 있다. 기후변화 연구에는 대체로 이산화탄소 배출 시나리오에 근거한 GCM 모의 결과가 사용되며, GCM 자료를 바탕으로 미래의 수문량 변화를 예측하는 방법으로 진행된다. 기후변화가 강우에 미치는 영향과 관련해서는 기후변화가 총강우량에 미치는 영향에 대한 연구가 주를 이뤄왔으나 극한강우량에 미치는 영향에 대한 연구는 미흡한 실정이다. 또한 상세화 된 강우 자료가 월단위 또는 일단위이기 때문에 극한홍수량 산정에 필요한 시단위 극한강우량 추정에는 한계가 있다. 본 연구에서는 기후변화가 극한강우량에 미치는 영향을 분석하기 위해 A2 시나리오에 근거한 ECHO-G 모델의 모의 결과를 상세화 시켜 얻은 한강 유역 내의 9개 강우 관측 지점의 일강우 자료를 바탕으로 강우의 scaling invariance 특성에 근거한 시단위 확률강우량을 추정하였고, Neymann-Scott Rectangular Pulse Model (NSRPM)을 적용하여 시단위 확률강우량을 추정하였다. 이러한 방법으로 추정된 9개 지점의 확률강우량과 한강유역종합치수계획(국토해양부, 2008)에서 산정한 확률강우량을 비교하여 미래의 확률강우량 변화를 분석하였다. 분석된 한강 유역 내 강우 관측 지점의 확률강우량 변화 추이는 지점에 따라 상이하게 나타났으며, 이에 따른 확률홍수량의 변화를 검토해 보는 것은 미래의 치수 측면에서 필요한 작업이라 할 수 있다. 또한 기후 변화의 영향은 시나리오와 GCM에 따라 달라질 수 있기 때문에 향후 다양한 시나리오와 GCM에 따른 확률 강우량 변화를 분석할 필요가 있을 것으로 판단된다.

  • PDF

Evaluation on Surface Scaling and Frost Resistance for concrete Deteriorated due to Cyclic Freezing and Thawing with Inherent Chloride

  • Kim, Gyu Yong;Cho, Bong Suk;Lee, Seung Hoon;Kim, Moo Han
    • Corrosion Science and Technology
    • /
    • v.6 no.4
    • /
    • pp.177-185
    • /
    • 2007
  • The purpose of this study is to evaluate freezing-thawing and surface scaling resistance in order to examine the frost durability of concrete in a chloride-inherent environment. The mixing design for this study is as follows: 3 water binder ratios of 0.37, 0.42, and 0.47; 2-ingredient type concrete (50% OPC concrete and 50% ground granulated blast-furnace slag), and 3-ingredient type concrete (50% OPC concrete, 15% fly ash, and 35% ground granulated blast-furnace slag). As found in this study, the decrease of durability was much more noticeable in combined deterioration through both salt damage and frost damage than in a single deterioration through either ofthese; when using blast-furnace slag in freezing-thawing seawater, the frost durability and surface deterioration resistance was evaluated as higher than when using OPC concrete. BF 50% concrete, especially, rather than BFS35%+FA15%, had a notable effect on resistance to chloride penetration and freezing/expansion. It has been confirmed that surface deterioration can be evaluated through a quantitative analysis of scaling, calculated from concrete's underwater weight and surface-dry weight as affected by the freezing-thawing of seawater.

Scaling Analysis of Thermal Hydraulics Phenomena in the Nuclear Reactor Vessel Downcomer during the Reflood Phase of LBLOCA (대형냉각재 상실사고 재관수 기간 동안, 차세대 원자로 강수부 내의 열수력 현상 모의를 위한 실험장치 척도해석)

  • Yun, B.J.;Song, C.H.;Kwon, T.S.;Euh, D.J.;Chu, I.C.;Yoon, Y.J.
    • Proceedings of the KSME Conference
    • /
    • 2001.06d
    • /
    • pp.821-827
    • /
    • 2001
  • As one of the advanced design features of the Korea next generation reactor, direct vessel injection (DVI) system is being considered instead of conventional cold leg injection (CLl) system. It is known that the DVI system greatly enhances the reliability of the emergency core cooling (ECC) system. However, there is still a dispute on its performance in terms of water delivery to the reactor core during the reflood period of a large-break loss-of-coolant accident (LOCA). Thus, experimental validation is under progress. In this paper, a new scaling method, using time and velocity reduced linear scaling law, is suggested for the design of a scaled-down experimental facility to investigate the direct ECC bypass phenomena in PWR downcomer.

  • PDF

Comparison of 1-g and Centrifuge Model Tests on Liquefied Sand Grounds (액상화 지반에 대한 1-g 모형실험과 원심모형실험의 비교 연구)

  • Kim, Sung-Ryul;Hwang, Jae-Ik;Ko, Hon-Yim;Kim, Myoung-Mo
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 2006.03a
    • /
    • pp.97-104
    • /
    • 2006
  • The centrifuge and 1-g shaking table tests were performed simultaneously to compare the dynamic behaviors of loose sands of same geotechnical properties. The prototype soils were 10 m thick liquefiable loose sands. The geometric scaling factors were 20 for 1-g and 40 for centrifuge tests. The excess pore pressure, surface settlement, and acceleration in the soil were measured at the same locations in the 1-g and centrifuge tests. The total excess pore pressure from development to dissipation was measured. In the centrifuge test, viscous fluid was used as the pore water to eliminate the time scaling difference between dynamic time and dissipation time. In the 1-g tests, the steady state concept was applied to determine the unit weight of the model soil, and two different time scaling factors were applied for the dynamic time and the dissipationtime. It is concluded that the 1-g tests can simulate the excess pore pressure of the prototype soil if the permeability of the model soil is small enough to prevent dissipation of excess pore pressure during shaking and the dissipation time scaling factor is properly determined.

  • PDF

Rainfall Quantile Estimation based on Scaling Invariance Property (강우자료의 지속기간별 스케일링 성질을 이용한 확률강우량 산정)

  • Jung, Young-Hun;Kim, Soo-Young;Kim, Tae-Soon;Heo, Jun-Haeng
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2007.05a
    • /
    • pp.1538-1542
    • /
    • 2007
  • 확률강우량은 일반적으로 년최대 강우량자료를 바탕으로 빈도해석을 실시하여 산정하며, 국내에서는 주로 매시각별로 관측된 자료를 이용하여 지속기간 1시간에서 24시간 사이에 대하여 산정하고 있다. 그러나 도달시간이 매우 단시간인 도시 유역의 확률강우량 산정을 위해서는 지속기간 15분 혹은 지속기간 30분과 같은 짧은 지속기간에 대한 확률강우량의 추정이 필요하며, 이와는 반대로 지속기간 24시간 이상의 장기간에 대한 확률강우량의 추정이 필요한 경우도 있다. 본 연구에서는 이와 같이 관측되지 않은 지속기간에 대한 확률강 우량을 산정하기 위한 방법으로써 강우자료의 지속기간별로 일정한 스케일이 유지된다는 스케일링 성질(Scaling Invariance Property)을 적용하여 확률강우량을 산정하였다. 이를 위해 대상지역의 지속기간별 년최대 강우량자료를 구축한 뒤 L-모멘트법으로 산정된 매개변수와 스케일링 성질을 이용하여 확률강우량을 산정한 후 이를 기존의 빈도해석 결과에 의한 확률강우량과 비교하여 적용성을 판단하였다.

  • PDF

Evaluation of calcium carbonate scale formation on system design of seawater reverse osmosis plants (해수담수화 시설의 시스템 구성에 따른 $CaCO_3$ 스케일 형성능 진단)

  • Kang, Nam-Wook;Choi, Yang-Hun;Lee, Hye-Ju;Lee, Seock-Heon;Kweon, Ji-Hyang
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.24 no.2
    • /
    • pp.143-155
    • /
    • 2010
  • Fouling by inorganic scales needs to be prevented to effectively operate sea water reverse osmosis(SWRO) membrane systems. The extents of inorganic scaling with different array designs including one-pass, two-pass and several hybrid designs were evaluated using seawater from southern sea near the city of Chang-Won. The used methods for evaluation were Stiff and Davis Index(S&DSI) calculation and several laboratory experiments. The formation potential of inorganic scale fouling was quite great under the examined conditions, which was confirmed by the laboratory experimental results. The inorganic scale was not avoidable fouling if any anti-scaling measures were not applied. The RO showed decreased flux under the scale formation conditions. The increases in S&DSI from 1.43 to 5 made small decreases in flux, which indicated that formation of inorganic scales had more substantial effects on RO flux than amount of inorganic scales.