• 제목/요약/키워드: Water sample

검색결과 2,813건 처리시간 0.028초

호수내의 인 제거에 관한 연구 (A Study on the Removal of Phosphorus in the Lake)

  • 강선홍;김경태
    • 상하수도학회지
    • /
    • 제12권2호
    • /
    • pp.59-66
    • /
    • 1998
  • The feasibility of usage of sludge from water treatment plant and chalk from schools and institutes was investigated to remove the phosphorus in the lakes which induce the eutrophication every year. In this study phosphorus removal efficiencies of sludge and chalk were investigated by changing various factors. Higher phosphorus removal efficiency using larger particle size of chalk was observed which means that the surface area is not an important factor in removing phosphorus in aqueous phase. The proper shaking time and temperature were 2 hours and $25^{\circ}C$, respectively. The removal efficiency using sludge from water treatment plant was almost 100%, which is similar to those of CaO and $Ca(OH)_2$. It means that sludge can be reused in removing phosphorus. It was also found that chalk was better in removing phosphorus under alkaline condition and sludge was better under acidic condition. About 75% phosphorus removal efficiency was observed using sludge from the water sample in Lake Sihwa.

  • PDF

성인 남녀의 투습방수소재 스포츠 웨어의 소재별 착용감에 관한 연구 (The Wearing Sensation of Men and Women in Sports Wear with Waterproof and Water Vapor Permeable Fabrics)

  • 조지현;류덕환
    • 한국생활과학회지
    • /
    • 제9권1호
    • /
    • pp.47-61
    • /
    • 2000
  • The purpose of this study was to examine the performance and properties of sports wear that have the excellent wearing sensation and are in harmony with the functions of human bodies. With four kind(sample A, B, C, D) of materials which have different water vapor transmission, the physiological responses of human bodies and the changes of subjective sensations were studied through the actual aerobic sports program at $20^{\circ}C$, 60%R.H. The forehead temperature had the minimal variation among the local skin temperatures. The fabrics of low water vapor transmission demonstrated high breast temperature. There are significant differences among materials depending on the humidity in clothes(especially back and breast), which was about 6 % for breast and about 14 % for back. The order of loss in body weight was in the opposite direction to that of water vapor transmission for each material.

  • PDF

어독성 시험에 의한 그라우팅재의 수질오염 평가 (The Evaluation of Toxic Effect of Grouting Materials by Fish Poison Test)

  • 천병석;김진춘;이영근
    • 한국지하수토양환경학회:학술대회논문집
    • /
    • 한국지하수토양환경학회 1998년도 공동 심포지엄 및 추계학술발표회
    • /
    • pp.156-161
    • /
    • 1998
  • As grouting materials for ground improvement, silicate materials such as water glass, silica-sol and so forth are used worldwide. However, they may pollute underground water. In this study, fish poison test(Korean standard industrial code KS M 0111) which estimates toxicity for fish is applied to evaluate the toxic effect by grouting materials. From the test result of the sample made of LW, LC50(Median Lethal Concentration) reaches within 24 hours. In case of the silica-sol, it does not even in 96 hours. Therefore, we can conclude that the sililca-sol grouting method is more free from the danger of underground water pollution. From the result that the mortality of fish under the condition of pH 8.6 is 0% within 96 hours, the groundwater can be saved by controlling pH below 8.6 for the grouting in the field.

  • PDF

Remote Monitoring of Abrupt Overflowing in Common Utility Duct Using Reflective Side-Polished Optical Fiber Submersion Sensor

  • Lee, Cherl-Hee;Kim, Cheol;Kang, Shin-Won;Song, Jae-Won
    • Journal of the Optical Society of Korea
    • /
    • 제12권3호
    • /
    • pp.166-169
    • /
    • 2008
  • The submersion monitoring system based on a reflective side-polished optical fiber submersion sensor with an optical fiber mirror was shown to be an effective alarm system with remote monitoringwhen the drainage capacity of a common utility duct is exceeded due to heavy rainfall. The proposed sensor was connected to an existing installed optical fiber network at a height of 250mm in a common utility duct, and then tested under sample materials(distilled water, river water, sea water, foul water, muddy water, petroleum, edible oil) at a distance of 1km from the sensor for remote sensing. In experiments, the proposed real-time sensor system reduced maintenance cost and improved monitoring efficiency by using a reflection-type side-polished optical fiber submersion sensor efficient for remote monitoring of a common utility duct.

Trifluoroacetic Anhydride를 이용한 NMR에 의한 수분정량 (Determination of Water with Trifluoroacetic Anhydride by NMR)

  • 이왕규;박만기;김박광;권세호;성방훈
    • 약학회지
    • /
    • 제26권4호
    • /
    • pp.257-260
    • /
    • 1982
  • Measurement of water is a subject of continued interest. High resolution proton magnetic resonance has not been very effective in the determination of water. Especially spectral overlap with other proton signals from the sample is undesirable result. However, trifluoroacetic anhydride reacts with water and forms trifluoroacetic acid and the proton signal of trifluoroacetic acid did not overlap with that of samples. By use of this fact, water in acetone, ethyl ether, dioxane, dichloroethane and methyl isobutyl ketone is analyzed by high resolution proton magnetic resonance (PMR). This method is capable of detecting as little as 200ppm of $H_{2}O$. And it is very rapid, simple and accurate.

  • PDF

수분열화에 의한 에폭시절연재료의 표면특성에 관한 연구 (A Study on the Surface Properties of Epoxy Insulator by Water Degradation)

  • 임경범;이백수;김종택;정무영;황명환;이덕출
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1998년도 춘계학술대회 논문집
    • /
    • pp.199-202
    • /
    • 1998
  • In examining application of polymer as electrical insulators, it is very important to perform accelerated aging test substituted the process which polymer insulator is degraded for long-time by the process of short-time. The purpose of this paper is to examine the properties of water degradation which affect on the efficiency of epoxy insulator. To do this, the surface properties on epoxy insulating material have been investigated after long-time accelerated degradation in boiling water condition. The experimental results showed the contact angle and surface resistivity after treatment to decrease the sample of water treatment. In dielectric properties, dielectric constant was increased by the aging development with water treatments.

  • PDF

ISO착화성시험방법에 의한 목재시료의 착화특성연구

  • 임흥순
    • 방재기술
    • /
    • 통권14호
    • /
    • pp.13-17
    • /
    • 1993
  • We intended to apprehend the ignitability of the wood, using the ISO test for the ignitability accessment. So we first conducted the ISO test on eight kings of the wood as sample, which came from domestic for-est, and discovered the tendency of the ignitability for the wood in the condition of external factors(its density and the rate of water content, humidity). Finally it was found that the ignition time of the wood was effected by its density and, the rate of water content, the humidity in the atmosphere.

  • PDF

Determination of Isotopic Ratios for Ca in Inductively Coupled Plasma Mass Spectrometry (ICPMS) by Removing Water Related Molecules

  • 박용남;S. R. Koirtyohann
    • Bulletin of the Korean Chemical Society
    • /
    • 제18권11호
    • /
    • pp.1172-1175
    • /
    • 1997
  • Calcium isotopic ratios are precisely measured by removing isobaric interferences originated from water in the plasma. Liquid Ar cryogenic trap combined with membrane desolvator could eliminate backgrounds at m/z 42 and 44. Slow drift of ICP-MS is corrected by the frequent running of the standards. It is found necessary to separate Ca from the sample matrix using Ca oxalate precipitation technique. Currently, the RSD is 0.5-1.0% for 2 minutes of measurement but is expected to be improved if the measurement time is increased. The technique was applied to 42Ca enriched baby fecal samples and successfully determined 42Ca/44Ca ratio changes.

용매와 추출조건에 따른 단삼 (Salvia mitiorrhiza) 추출물의 항균력 (Effects of Solvents and Extracting Condition on the Antimicrobial Activity of Salviae miltiorrhizae Radix (Saliva miltiorrhiza ) Extract)

  • 목종수;박욱연;김영목;장동석
    • 한국식품영양과학회지
    • /
    • 제23권6호
    • /
    • pp.1001-1007
    • /
    • 1994
  • In order to develop a natural food preservative, dried salviae miltiorrhizae radix (Salvia miltiorrhiza) was extracted with several solvents, and then antimicrobial activity was investigated. The optimum extracting condition for the antimicrobial sustance from the sample, minimal inhibitory concentration (MIC) of the extracted substance against microorganisms were also examined. Antimicrobial activity of the initial ethanol extract from the sample was the strongest compared to those of other solvent extracts such as n-hexane, acetone, butanol, methanol and water. the optimum extractingcondition for antimicrobial substance from the sample was shaking extraction for 2 hours at room temperature incase that 10 volumes of absolute ethanol was added to crushed Saliva Miltiorrhiza. The ethanol extract had strong growth inhibition activity against Gram-positive Bacteria (MIC, 3.13-50$\mu\textrm{g}$/ml) such as B. cereus, B, subtilis, L. minocytogenes, S. aureus, Sc. Mutans. Among Grampositive bacteria tested, Bacillus species was the most susceptibile to the extracted substance. The antimicrobial activity of the ethanol extract from the sample was weak to Gram -negative bacteria yeasts, for example MIC for Gram-negative bacteria and yeasts was 0.8mg/ml and 0.4-0.8mg/ml , respectively.

  • PDF

모세관 전지영동법에 의한 굴뚝에서 포집된 NaOH 용액속의 염소이온의 측정 (Determinaton of Chloride Ion Captured into Strong NaOH Solution from Chimney by Capillary Electrophoresis)

  • 임인덕;성용익;김양선;임흥빈
    • 한국대기환경학회지
    • /
    • 제15권3호
    • /
    • pp.327-333
    • /
    • 1999
  • Determination of chloride ion in concentrated NaOH solution by capillary electrophoresis has been studied. The analysis was performed by indirect UV absorption detection using chromate buffer at 254nm. The matrix effect of the sample has been observed so that the sensitivity in strong NaOH solutaion has decreased up to 10% of that in distilled water. The pH effect of the sample on the sensitivity of CE peaks has been investigated. The method for increasing the sensitivity have been investigated and the optimum pH and concentration of the buffer were 7.5 and 10mM, respectively. A cationic surfactant cetyltrimethylammonium bromide(CTAB), was added to a buffer solution in order to reverse the electroosmotic flow(EOF) in the capillary. This results in a short analysis time and better peak shapes. Using this optimum condition, the determination of chloride ion in real environmental sample has been performed, which is captured in strong NaOH absorbent prepared for absorbing gas from chimney. The standard addition method has been applied for the quantitative analysis, and it was obtained the good reproducibility.

  • PDF