• Title/Summary/Keyword: Water reuse system

Search Result 186, Processing Time 0.028 seconds

Recirculating Aquaculture System Design and Water Treatment Analysis based on CFD Simulation

  • Juhyoung Sung;Sungyoon Cho;Wongi Jeon;Yangseob Kim;Kiwon Kwon;Deuk-young Jeong
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.17 no.11
    • /
    • pp.3083-3098
    • /
    • 2023
  • As demands for efficient and echo-friendly production of marine products increase, smart aquaculture based on information and communication technology (ICT) has become a promising trend. The smart aquaculture is expected to control fundamental farm environment variables including water temperature and dissolved oxygen (DO) levels with less human intervention. A recirculating aquaculture system (RAS) is required for the smart aquaculture which utilizes a purification tank to reuse water drained from the water tank while blocking the external environment. Elaborate water treatment should be considered to properly operate RAS. However, analyzing the water treatment performance is a challenging issue because fish farm circumstance continuously changes and recursively affects water fluidity. To handle this issue, we introduce computational fluid dynamics (CFD) aided water treatment analysis including water fluidity and the solid particles removal efficiency. We adopt RAS parameters widely used in the real aquaculture field to better reflect the real situation. The simulation results provide several indicators for users to check performance metrics when planning to select appropriate RAS without actually using it which costs a lot to operate.

Thermal Analysis of Double-tube Triple-flow LNG Vaporization System (이중관 삼중흐름 열교환에 의한 LNG 기화시스템의 열적 해석)

  • 윤상국
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.27 no.7
    • /
    • pp.839-844
    • /
    • 2003
  • As sea water is being used as only heat source of LNG open rack vaporizer, serious problem has been risen in LNG terminal by the lack of heating energy source for LNG vaporization due to the temperature drop of sea water in winter. In this paper the new double-tube triple-flow(TRIDEX) vaporizer was suggested to solve the problem and the system was thermally analysed. LPG(liquefied petroleum gas) and sea water were introduced as the heat sources for LNG TRIDEX vaporizer. The flow patterns of TRIDEX vaporizer are as follows: LNG flow in the annular space, PG(petroleum gas) flow in the inner tube, and sea water flow in the outside of the double pipe. The overall LNG vaporization system was consisted of TRIDEX vaporizer, LPG vaporizer and PG heater. LPG in TRIDEX was directly dispersed in the sea water desalination unit, so that LPG turns to be gas phase for the reuse in TRIDEX vaporizer. New TRIDEX vaporizer system for LNG evaporation was analysed as much more effective than the present single tube one in the case of colder temperature of sea water in winter.

Development of Optimal Septic Tank in the Countries of Water Shortages (물 부족국가에서 활용가능한 정화조의 최적모형 개발)

  • Lim, Bong-Su;Jing, Hai-Long
    • Journal of Korean Society on Water Environment
    • /
    • v.31 no.4
    • /
    • pp.418-427
    • /
    • 2015
  • This study was carried out to evaluate the performance of a lab-scale novel septic tank system for improving the conventional septic tank in the developing countries of water shortages. The lab-scale novel septic tank system consists of sepetic tank, aeration tank with HBC-ring, and sand filter. Optimum HRT was reguired about 1.5days to get a total COD removal efficiency of 90%, COD, BOD and SS removal efficiency was about 70%, 60%, and 85% in sepetic tank only. The structure of sepetic tank with two stages results in the high removal efficiency of organic matter. When sepetic tank, aeration tank, and sand filter were more than HRT 1.5days, 18hrs, and 12hrs, respectively, final effluent was less than 20 mg/L of BOD, 14 mg/L of SS, so that there is a high potential of its use for reusing water in flush toilet. There is no significant effect of HRT change on nutrient removal. Total nitrogen removal efficiency was about 40%, final effluent was 30~40 mg/L of TN, total phosphorus removal efficiency was about 11~25%, final effluent was 9~12 mg/L of TP. Because there is very small amounts of organic nitrogen and phosphorus in effluent, it was possible to reuse water for agricultural use.

The Background and Direction of R&D Project for Advanced Technology of Wastewater Treatment and Reuse (하.폐수 고도처리 기술개발사업 추진배경과 개발방향)

  • Kim, Ji-Tae;Hwang, Hae-Young;Hong, Byung-Pyo;Byun, Hong-Sik
    • Membrane Journal
    • /
    • v.21 no.3
    • /
    • pp.277-289
    • /
    • 2011
  • Since 1980s, wastewater treatment facilities in Korea have been rapidly expanded by 90 percent as the government invested them continuously. Considering social and environmental factors such as the needs of alternative water resources for water shortages, energy saving and new energy production sources for decrease of greenhouse gases, and the demand for the improvement of the water quality in rivers and lakes, advanced technologies in wastewater treatment are essential in the 21st century. In this aspect, new conceptual technology is systematically combined with the advanced treatment technology such as the control and treatment technology of hazardous and toxic material, customized reusing skill, and energy saving/recovery technology. The new R&D project for advanced technology of wastewater treatment and reuse will focus on these advanced technologies which will improve the water quality and foster the competitiveness in world environmental markets, building a solid foundation particularly in the market of developing countries. The project will be divided up into high quality reusing of wastewater, energy self-sufficiency, and integrated management system. It will be carried out for five years, 2011~2015, as Phase I.

Study on the Removal of Fluorescent Whitening Agent for Paper-mill Wastewater Reuse using the Submerged Membrane Bioreactor(SMBR) with Ozone Oxidation Process (제지폐수 재이용을 위한 침지형 생물막 여과와 오존산화공정(SMBR-Ozone Oxidation Process)에 의한 형광증백제 제거에 관한 연구)

  • Choi, Jang-Seung;Shin, Dong-Hun;Ryu, Seung-Han;Lee, Jae-Hun;Ryu, Jae-Young;Shin, Won-Sik;Lee, Seul-Ki;Park, Min-Soo;Lee, Sang Oh
    • Textile Coloration and Finishing
    • /
    • v.30 no.1
    • /
    • pp.51-61
    • /
    • 2018
  • In this study, effluent water was produced through Submerged Membrane Bio-Reactor(SMBR) process, which is a simple system and decomposes organic matter contained in wastewater with biological treatment process and performs solid-liquid separation, Especially, ozone oxidation treatment process is applied to effluent water containing fluorescent whitening agent, which is a trace pollutant which is not removed by biological treatment, and influences the quality of reused water. The concentration of $COD_{Cr}$ in the SMBR was $449.3mg/{\ell}-COD_{Cr}$, and the concentration of permeate water was $100.3mg/{\ell}-COD_{Cr}$. The removal efficiency was about 70.1%. The amount of ozone required for the removal of the fluorescent whitening agent in the permeated water in SMBR was $6.67g-O_3/min$, and the amount of ozone required to remove $COD_{Mn}$ relative to the permeate water was calculated to remove $0.997mg-COD_{Mn}$ for 1mg of $O_3$.

Analysis of the Function of the Paddy-field in Purifying Water Quality (논의 수질정화 기능 분석)

  • Kim, Hyeon-Soo;Kim, Young-Il;Kim, Jin-Soo
    • Proceedings of the Korean Society of Agricultural Engineers Conference
    • /
    • 2003.10a
    • /
    • pp.599-602
    • /
    • 2003
  • The objective of this study is to analyze the function of the paddy-field in purifying water quality. This study was carried out is based on the data in the six case studies. To improve purification function of paddy field, the following farming management is required. 1) A guideline to control the inlet and outlet of the paddy plot is need to minimize drainage water by means of a reasonable irrigation management. 2) A guideline for fertilizer application in consideration of loading nutrients dissolved in irrigation water. 3) The reuse system of agricultural drainage water is required to minimize impacts on water quality of surface water(reservoir and river).

  • PDF

Flow analysis of the Hydrogen Recirculation System for Fuel Cells (연료전지 수소 재순환 시스템의 유동해석)

  • Kim, Jae-Choon;Lee, Yong-Taek;Chung, Jin-Taek;Kim, Yong-Chan;Hwang, In-Chul
    • 유체기계공업학회:학술대회논문집
    • /
    • 2005.12a
    • /
    • pp.759-764
    • /
    • 2005
  • In this paper, numerical analysis of hydrogen recycle system has been conducted in order to enhance the efficiency of automotive fuel cell. Generally, the excess hydrogen is provided in the automotive fuel cell. Since the non-reaction hydrogen reduces automotive fuel cell efficiency, reuse of the non-reaction hydrogen can be helpful to improve the fuel cell performance. In case of PEM FC, the water vapor is provided to hydrogen from the cathode so that the mixture experiences phase change depending on the changes of pressure and temperature. The internal flow of the mixture in the hydrogen recirculation system of fuel cell was investigated for real flow conditions. The variation of performance, properties and mass fractions of mixture, hydrogen and water-vapor were investigated. This study was performed based on 80KW level automotive fuel cell's recycling system.

  • PDF

Role of Water Current in the CROM Operation for the Water Quality Improvement of Eutrophic Reservoir (부영양 저수지의 수질개선을 위한 CROM 운영 및 유속의 영향)

  • Lee, Ju-Hwan;Hwang, Soon-Jin;Kim, Baik-Ho
    • Journal of Korean Society on Water Environment
    • /
    • v.26 no.3
    • /
    • pp.518-524
    • /
    • 2010
  • Continuous removal of organic matters (CROM) using freshwater bivalve Anodonta woodiana was operated to evaluate the effect of water current on the water quality improvement (clearance) of eutrophic lake. The CROM system comprised three treatment steps such as flow control, treatment and analysis, and operated at the two different currents ($24L\;h^{-1}$ and $48L\;h^{-1}$) with mussels at density of $312.5indiv.\;m^{-2}$ for 12 consecutive days. Water quality including suspended solids (SS) and chlorophyll-a (Chl-a) was daily measured at the same time. Results indicate that although both the system strongly decreased the concentration of SS and chl-a, a slow CROM system was more effective to diminish the SS contents than a fast CROM system; 82% and 66%, respectively (ANOVA, P<0.0001). Clearance rates, based on chl-a, were also significantly higher in a slow system than a fast system (ANOVA, P<0.0001), although the mussel mortality was conversely. In both systems, there showed a remarkable excretion of dissolved inorganic nutrients (i.e. $NH_3-N$ and $PO_4-P$), while a slow CROM system was higher than a fast system, significantly (ANOVA, P<0.0001). Therefore, it may suggest that a slow current CROM system is more suitable to maximize the efficacy of water quality improvement, but further study is needed to diminish the mortality of mussel and to reuse the nutrient released during the operation.

Design and Operation of the Rainwater-Greywater Hybrid System : SNU No. 39 Building (빗물-저농도 오수 하이브리드 시스템의 설계 및 운전 평가 : 서울대 39동)

  • Shim, In-tae;Park, Hyun-ju;Kim, Tschung-il;Jung, Sung-un;Han, Moo-young;Namkung, Eun
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.38 no.12
    • /
    • pp.676-682
    • /
    • 2016
  • In this study, rainwater-greywater hybrid system was installed and operated for 1 year in order to evaluate its water quantity, water quality, and economic efficiency in building no. 39. This system was expected to overcome each disadvantages of and maximize each advantages. Low-greywater that was washed up from shower room was treated by MBR (Membrane Bioreactor) and ozone oxidation. Rainwater that was collected from the rooftop was stored in a reservoir, and then transferred to the storage tank that was mixed with treated greywater. After 1 year operating in building no. 39, rainwater and greywater was used to supply $2,599m^3$ of toilet flushing water. In terms of water quality, rainwater was satisfied far the greywater reuse standards except for E.coli. Moreover, low greywater quality was acceptable except for E. coli, BOD, SS, and turbidity. In addition, economic analysis was obtained from benefit-cost ratio (B/C) with 1.11. It implies that the feasibility of the project was reasonable. Furthermore, various research and policy to improve the economic efficiency of water recycling facilities is required to expand the use of water recycling facilities.

A Study on Selection Method of Management Watershed for Total Pollution Load Control at Tributary (지류총량관리를 위한 관리유역 선정 방법에 관한 연구)

  • Hwang, Ha Sun;Lee, Sung Jun;Ryu, Jichul;Park, Ji Hyung;Kim, Yong Seok;Ahn, Ki Hong
    • Journal of Korean Society on Water Environment
    • /
    • v.32 no.6
    • /
    • pp.528-536
    • /
    • 2016
  • The purpose of Total Pollution Load Control at Tributary is to obtain maximum improvement effect of water quality through finding the most impaired section of water-body and establishing the proper control measure of pollutant load. This study was implemented to determine the optimal management of reach, period, condition, watershed, and pollution source and propose appropriate reduction practices using the Load duration curve (LDC) and field monitoring data. With the data of measurement, LDC analysis shows that the most impaired condition is reach V (G4~G5), E group (flow exceedance percentile 90~100%) and winter season. For this reason, winter season and low flow condition should be preferentially considered to restore water quality. The result of pollution analysis for the priority reach and period shows that agricultural nonpoint source loads from onion and garlic culture are most polluting. Therefore, it is concluded that agricultural reuse of surface effluent (storm-water runoff with non-point sources) and low impact farming that includes reducing fertilization and controlling the height of drainage outlet are efficient water quality management for this study watershed.