• Title/Summary/Keyword: Water reuse system

Search Result 186, Processing Time 0.034 seconds

Analysis of Wastewater Reuse Effect on Field-Scale Water Quality (하수처리수의 농업용수 재이용에 따른 포장단위 수질영향 분석)

  • Seong, Choung-Hyun;Kim, Sung-Jae;Kim, Sung-Min;Kim, Sang-Min
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.53 no.4
    • /
    • pp.59-65
    • /
    • 2011
  • The purpose of this study was to analyze the water quality change when wastewater applied to study paddy fields. CREAMS-PADDY (Chemical, Runoff and Erosion from Agricultural Management System) model was used to estimate the field-scale water quality. Simulated results were compared with observed data monitored from Byeongjeom study paddy fields which is located near the Suwon sewage treatment plant in Gyeonggi-do. Significance analysis was performed for the three different irrigation water quality level and five fertilizer reduction scenarios using LSD (Least Significant Difference) and DMRT (Duncan's Multiple Range Test). Total nitrogen was found to be significant for both irrigation water quality level and fertilizer reduction while total phosphorus was not. Annual drainage load for total nitrogen was reduced by 66~92 % compared to irrigation load when treated wastewater irrigated to study paddy fields from 2002 to 2007. Total phosphorus was reduced by 70~86 %.

A Study on the Application Method for Recycling Water System (가압형평막(한외여과막)과 자외선 및 오존발생 장치(AOP System)를 이용한 중수설비 적용에 관한 연구)

  • Kim Sang-Sik;Han Mi-Sun
    • Journal of the Korea Institute of Building Construction
    • /
    • v.6 no.2 s.20
    • /
    • pp.65-72
    • /
    • 2006
  • The amount of water demand at large buildings is increasing with the concentration of population to city and a rise in the standard of living in the city area. In this reason the Water Shortage is expected and a problem of water pollution by the city sewerage is increasing. One of method of saving city water demand and city sewer is applying recycling water system witch make used water reuse by purification of water. The application of recycling water system witch make used performed since the application of Lotte World Complex. But the popularization of this system is not activated because of cost problem and feeling of people to the water recycled. So in this study, provide application method for recycling water system by propose the estimation method of optimal sizing of recycling water system.

Life-Cycle Assessment (LCA) for Eco-Design in a Wastewater Reuse Facility (친환경 설계를 위한 하수처리수 재이용시설의 전과정 평가)

  • Lee, Sin-Won;Kim, Sung-Keun
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.31 no.2D
    • /
    • pp.255-266
    • /
    • 2011
  • In order to evaluate the environmental load occurring from the whole life cycle of a facility, LCA (Life Cycle Assessment) adopted by ISO is not only applied as an individual product but rather a complicated system involving buildings and/or infrastructure in a wide range of scope. The introducing of LCA to a wastewater reuse facility will assist to understand not only the treatment of water contaminants but also the overall system related to the interaction of involved, potential issues. This research implemented LCA for the establishment of the wastewater reuse facility. The results show that a fresh water aquatic Eco-toxicological Impact (88.3%) is the largest environment concern and the maintenance & operation phase has the most impact on the environment utilizing life cycle for the wastewater reuse facility. The civil works and chemical treatments in the maintenance & operation phase led to the biggest environmental impact. The results of this research can provide pertinent data of investigating opportunities for environmental improvement not limited to public officers regulating environmental policies, and could be used to make decisions for an environmentally sound and sustainable design in the initial phase of construction.

Organic fouling in forward osmosis (FO): Membrane flux behavior and foulant quantification

  • Xia, Shengji;Yao, Lijuan;Yang, Ruilin;Zhou, Yumin
    • Membrane and Water Treatment
    • /
    • v.6 no.2
    • /
    • pp.161-172
    • /
    • 2015
  • Forward osmosis (FO) is an emerging membrane technology with potential applications in desalination and wastewater reclamation. The osmotic pressure gradient across the FO membrane is used to generate water flux. In this study, flux performance and foulant deposition on the FO membrane were systematically investigated with a co-current cross-flow membrane system. Sodium alginate (SA), bovine serum albumin (BSA) and tannic acid (TA) were used as model foulants. Organics adsorbed on the membrane were peeled off via oscillation and characterized by Fourier transform infrared (FTIR) spectroscopy and scanning electron microscopy (SEM). When an initial flux of $8.42L/m^2h$ was applied, both flux reduction and foulant deposition were slight for the feed solution containing BSA and TA. In comparison, flux reduction and foulant deposition were much more severe for the feed solution containing SA, as a distinct SA cake-layer was formed on the membrane surface and played a crucial role in membrane fouling. In addition, as the initial SA concentration increased in FS, the thickness of the cake-layer increased remarkably, and the membrane fouling became more severe.

Treatment Characteristics of Rapid filtration Process treating Secondary Clarifier Effluent for Wastewater Reuse (처리수 재이용을 위한 최종침전지 유출수의 급속여과공정 처리특성)

  • Han, Dong-U
    • Journal of Korea Water Resources Association
    • /
    • v.35 no.2
    • /
    • pp.213-220
    • /
    • 2002
  • This reserch was focused upon experimental study for wastewater reuse and conducted to evaluate optimum operating conditions of rapid filtration process such as filter flow rate, filtration time and backwashing condition for reuse of secondary-treated effluent using the pilot plant installed in real wastewater treatment plant. Also, the experiment on treatment char-acteristics of coagulant-added activated sludge process was performed to compare with activated sludge succeeded to rapid filtration. As the filtration velocity was 100m/day, the filtration time of the rapid filter connected with activated sludge system was revealed to 40 hours. Backwashing of filter was conducted by water wash and air scour. The optimum backwashing time and backwash flow rate were 10min and 10LPM, respectively. The quantity of backwashing water of the rapid filter was about 2% of total treated water.

Determinant Factor Analysis for the Spread of Water Reuse (물재이용 활성화를 위한 결정요인분석)

  • Park, Hyunju;Kim, Tschungil;Han, Mooyoung
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.36 no.4
    • /
    • pp.271-276
    • /
    • 2014
  • The purpose of this study was to survey Suwon citizens over the age of 20 in order to provide basic data on the extent of coverage of the city's water reclamation system and to set guidelines for a policy on water reuse. The survey used a questionnaire with two fields, rainwater use and wastewater recycling, for analyzing factors that influenced water reuse. A factor analysis of 19 questionnaires gave a Cronbach's alpha coefficient greater than 0.4. Factors that influenced rainwater use were environmental protection, water charges, and the risk of climate change. Of the total explanatory power, the share of rainwater use and environmental protection was 39.7% and 28.1% respectively. Environmental protection (explanatory power 24.2%) had an effect on the explanatory power of wastewater reuse. When factors influencing wastewater recycling, like cost of recycling, water management policy, climate change, and suspension of tap water supply were included, the explanatory power of each of these factors went up by 4.3%, 2.8%, 3.3%, and 1.1%, respectively. For more effective wastewater recycling, a water management policy that factors in the above is required, along with a campaign to educate citizens on water management and environment conservation. Additionally, it may be necessary to improve the reliability and the quality of water supply.

A Study on Reuse System of Dyeing Wastewater using Membrane (막을 이용한 염색폐수의 재활용 연구)

  • 서명포
    • Textile Coloration and Finishing
    • /
    • v.10 no.4
    • /
    • pp.45-52
    • /
    • 1998
  • Reuse of wastewater become an important consideration to solve the environmental pollution problems in recent industriallzation and urbanization. Especially, he characteristic of dyeing process is subject to use much water and thus has serious problems for removal of color and organic pollutants in their wastewater. This report is divided into two main parts : The purpose of the first part was to determine if alkaline wastewater discharged from textile dyeing operation factory could be flocculated directly by Fenton oxidation method. This study was conducted to investigate Fenton reagent dose and reaction condition of Fenton method as pretreatment for dyeing wastewater in K dyeing industry were investigated. In the second part of this research, to treat dyeing wastewater it was found that the most effective way is to use ultrafiltation and reverse osmosis at the conditions of the pH 7.0~8.0 and operating pressure of $2.5~35kg_f/cm^2$. This paper is mainly dealt with the application on reuse system of dyeing wastewater treatment using ultrafiltration and reverse osmosis membranes. The results showed that dyeing wastewater could be reused by chemical, filter and membrane sequential treatment process.

  • PDF

Prospect and strategies of seawater desalination plant in Asia major countries (아시아 주요국의 해수담수화 플랜트 시장전망과 진출방안)

  • Sohn, Jin-Sik;Han, Ji-Hee;Kim, Suk-Hwa;Sheen, Dong-Woo;Lim, Jae-Han
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.24 no.2
    • /
    • pp.157-164
    • /
    • 2010
  • Seawater desalination has vest interest in terms of ultimate water resources for the countries suffering lack of water supply. Water demand is steadily increasing due to the population growth and industrialization in Asia. The objectives of this study are to prospect the desalination market in Asia countries including China, India and Singapore, and to propose possible strategies of getting through Asia water market. Water supply in China is increasing up to $5,322,060m^3$/d in 2015. Northeast coastal areas such as Tianjin, Shandong, Hubei, and Liaoning are expected rapid increase for water demand. The investment of water supply in India would be 1.74 billion dollars during 2006 to 2015. Chennai, Kutch, and Pondicherry have possibility in introducing seawater desalination plants. Singapore is focusing on water reuse, and operating three NEWater plants (water reuse plants). BOT with total solution providing financing, construction, operation etc. is an adequate strategy to getting through China water market, while desalination plant project connecting with power plant is desirable in India. The cooperative system with Korea and Singapore creates synergy effect regarding planning and operating experience of Singapore and EPC ability of Korea.

Rearing Olive Flounder Paralichthys olivaceus in a Water Reuse System with Mineral Particles and foam Fractionator (광물미립자와 포말분리장치를 이용한 사육수 재사용시스템에서의 넙치(Paralichthys olivaceus) 사육실험)

  • 민병서;강필애
    • Journal of Aquaculture
    • /
    • v.13 no.3
    • /
    • pp.223-230
    • /
    • 2000
  • A rearing experiment of the olive flounder was performed in a set of water-reuse system to test the reusability of the water in culture system with (i) a foam fractionator to separate particles from water and (ii) a culture tank contain mineral particles to filter the metabolic wastes by adsorption and/or decomposition. Two kinds of commercially processed loess particles and a dolomite particle (all 50 ${\mu}$diameter) were tested. The mineral particles were suspended in the culture tank and the water was pumped into the foam fractionator, where the particles were separated and drained out with foam from the system. In a circular culture tank of 4.8 m in diameter with 10 d water, the juvenile olive flounders (23.1 g/fish, 5,555 fish, 128 kg total body weight) were stocked. 90 % of the rearing water was reused and turnover rate of the water in the tank was two times per hour. Water temperature was maintained 17${\pm}$1$^{\circ}C$. At the end of 75 day-experimental rearing, 5,532 flounders, weighing 468 kg, were harvested. An individual flounder grew to 84.6 g of body weight. The final stocking density was 26.0 kg/$m^2$. No diseases were observed during the experiment.

  • PDF

Treatment and Reuse of Acrylic Wastewater using Membrane Separation System

  • Lee, Kwanghyun
    • Proceedings of the Membrane Society of Korea Conference
    • /
    • 2004.05a
    • /
    • pp.117-120
    • /
    • 2004
  • The separation characteristics were investigated with the variations of pressure and temperature using ultrafiltration and reverse osmosis membrane module sets composed of different membrane types and materials. TDS, T-N and COD removal efficiencies were not affected and low with the change of temperature and pressure in case of using UF modules contained in module set 1, 2, 3. TDS, T-N and COD removal efficiencies were very high in RO modules. The final water quality of acrylic wastewater was satisfied within the discharge limit value of plant wastewater. It was known that membrane module sets could be used for the reuse of wastewater.

  • PDF