• Title/Summary/Keyword: Water reducing performance

Search Result 345, Processing Time 0.035 seconds

The Construction and Management of Artificial Wetland Using Emergent Macrophytes for High Biomass Production (대형정수식물을 활용한 높은 생산성의 인공습지 조성 및 관리)

  • Hong, Mun Gi;Heo, Young Jin;Kim, Jae Geun
    • Journal of Wetlands Research
    • /
    • v.16 no.1
    • /
    • pp.61-72
    • /
    • 2014
  • To present a guideline on the construction and management of artificial wetlands for high biomass production, three emergent macrophytes (Phragmites australis, PA; Typha angustifolia, TA; and Zizania latifolia, ZL) were planted under two substrates conditions (general soil with and without moss peat) and two water levels (5 cm and 20 cm) and monitored for three years. ZL showed greater growth performance rather than the others not only at early growth phase in the first year [shoot height, 200 cm; above-ground dry weight (AGDW), 500 $g/m^2$] but also in the last year (ZL, 1,100 $g/m^2$; TA, 770 $g/m^2$; and PA, 450 $g/m^2$ of AGDW). ZL with rapid growth at the early growth phase was not affected by naturally introduced weeds, whereas slower and poorer growth of PA and TA at the early growth phase resulted in relatively higher introduction and establishment of natural weeds. In turn, such introduced weeds negatively contributed to the growth of PA and TA particularly under shallow water (5 cm) with the substrate condition including moss peat. We suggest a plant material with rapid and great growth at the early phase such as ZL for reducing possible negative influences by the natural weeds and wild animals for high biomass production in constructed wetlands. A pre-growing process in greenhouse prior to planting might be an useful option to raise the competitiveness of those species when planting PA and/or TA. In addition, we recommend that integrated weed management system with utilizing various options at the most appropriate timing must be applied for maintaining sustainable high biomass production at the artificial wetlands.

Comparison of nutrient removal efficiency of an infiltration planter and an infiltration trench (침투도랑(IT)과 침투화분(IP)의 영양염류 저감효율 비교분석)

  • Yano, K.A.V.;Geronimo, F.K.F.;Reyes, N.J.D.G.;Jeon, Minsu;Kim, Leehyung
    • Journal of Wetlands Research
    • /
    • v.21 no.4
    • /
    • pp.384-391
    • /
    • 2019
  • Nutrients in stormwater runoff have raised concerns regarding water quality degradation in the recent years. Low impact development (LID) technologies are types of nature-based solutions developed to address water quality problems and restore the predevelopment hydrology of a catchment area. Two LID facilities, infiltration trench (IT) and infiltration planter (IP), are known for their high removal rate of nutrients through sedimentation and vegetation. Long-term monitoring was conducted to assess the performance and cite the advantages and disadvantages of utilizing the facilities in nutrient removal. Since a strong ionic bond exists between phosphorus compounds and sediments, reduction of total phosphorus (TP) (more than 76%), in both facilities was associated to the removal of total suspended solids (TSS) (more than 84%). The efficiency of nitrogen in IP is 28% higher than IT. Effective nitrification occurred in IT and particulate forms of nitrogen were removed through sedimentation and media filters. Decrease in ammonium- nitrogen (NH4-N) and nitrite-nitrogen (NO2-N), and increase in nitrate-nitrogen (NO3-N) fraction forms indicated that effective nitrification and denitrification occurred in IP. Hydrologic factors such as rainfall depth and rainfall intensity affected nutrient treatment capabilities of urban stormwater LID facilities The greatest monitored rainfall intensity of 11 mm/hr for IT yielded to 34% and 55% removal efficiencies for TN and TP, respectively, whereas, low rainfall intensities below 5 mm resulted to 100 % removal efficiency. The greatest monitored rainfall intensity for IP was 27 mm/hr, which still resulted to high removal efficiencies of 98% and 97% for TN and TP, respectively. Water quality assessment showed that both facilities were effective in reducing the amount of nutrients; however, IP was found to be more efficient than IT due to its additional provisions for plant uptake and larger storage volume.

Recent Progress in Air-Conditioning and Refrigeration Research : A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2016 (설비공학 분야의 최근 연구 동향 : 2016년 학회지 논문에 대한 종합적 고찰)

  • Lee, Dae-Young;Kim, Sa Ryang;Kim, Hyun-Jung;Kim, Dong-Seon;Park, Jun-Seok;Ihm, Pyeong Chan
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.29 no.6
    • /
    • pp.327-340
    • /
    • 2017
  • This article reviews the papers published in the Korean Journal of Air-Conditioning and Refrigeration Engineering during 2016. It is intended to understand the status of current research in the areas of heating, cooling, ventilation, sanitation, and indoor environments of buildings and plant facilities. Conclusions are as follows. (1) The research works on the thermal and fluid engineering have been reviewed as groups of flow, heat and mass transfer, the reduction of pollutant exhaust gas, cooling and heating, the renewable energy system and the flow around buildings. CFD schemes were used more for all research areas. (2) Research works on heat transfer area have been reviewed in the categories of heat transfer characteristics, pool boiling and condensing heat transfer and industrial heat exchangers. Researches on heat transfer characteristics included the results of the long-term performance variation of the plate-type enthalpy exchange element made of paper, design optimization of an extruded-type cooling structure for reducing the weight of LED street lights, and hot plate welding of thermoplastic elastomer packing. In the area of pool boiling and condensing, the heat transfer characteristics of a finned-tube heat exchanger in a PCM (phase change material) thermal energy storage system, influence of flow boiling heat transfer on fouling phenomenon in nanofluids, and PCM at the simultaneous charging and discharging condition were studied. In the area of industrial heat exchangers, one-dimensional flow network model and porous-media model, and R245fa in a plate-shell heat exchanger were studied. (3) Various studies were published in the categories of refrigeration cycle, alternative refrigeration/energy system, system control. In the refrigeration cycle category, subjects include mobile cold storage heat exchanger, compressor reliability, indirect refrigeration system with $CO_2$ as secondary fluid, heat pump for fuel-cell vehicle, heat recovery from hybrid drier and heat exchangers with two-port and flat tubes. In the alternative refrigeration/energy system category, subjects include membrane module for dehumidification refrigeration, desiccant-assisted low-temperature drying, regenerative evaporative cooler and ejector-assisted multi-stage evaporation. In the system control category, subjects include multi-refrigeration system control, emergency cooling of data center and variable-speed compressor control. (4) In building mechanical system research fields, fifteenth studies were reported for achieving effective design of the mechanical systems, and also for maximizing the energy efficiency of buildings. The topics of the studies included energy performance, HVAC system, ventilation, renewable energies, etc. Proposed designs, performance tests using numerical methods and experiments provide useful information and key data which could be help for improving the energy efficiency of the buildings. (5) The field of architectural environment was mostly focused on indoor environment and building energy. The main researches of indoor environment were related to the analyses of indoor thermal environments controlled by portable cooler, the effects of outdoor wind pressure in airflow at high-rise buildings, window air tightness related to the filling piece shapes, stack effect in core type's office building and the development of a movable drawer-type light shelf with adjustable depth of the reflector. The subjects of building energy were worked on the energy consumption analysis in office building, the prediction of exit air temperature of horizontal geothermal heat exchanger, LS-SVM based modeling of hot water supply load for district heating system, the energy saving effect of ERV system using night purge control method and the effect of strengthened insulation level to the building heating and cooling load.

Antioxidant activity and comparative analysis of major functional compounds in liqueur using coffee and coffee-ground (커피와 커피박 침출주의 항산화 활성 및 주요 생리활성 물질의 비교 분석)

  • Kang, Jeong Eun;Park, Seon Kyeong;Guo, Tian Jiao;Kang, Jin Yong;Lee, Du Sang;Kim, Jong Min;Kwon, O-Jun;Lee, Uk;Heo, Ho Jin
    • Food Science and Preservation
    • /
    • v.23 no.4
    • /
    • pp.560-567
    • /
    • 2016
  • Sensory evaluation, in vitro antioxidant activities and main compounds of coffee water-extract, coffee liqueur (CL) and coffee-ground liqueur (CGL) were investigated to consider their industrialization. Sensory evaluation showed that all groups of CGL without 25% CGL (3 month) were relatively higher than CL groups. Total phenolic compounds and in vitro antioxidant activities such as 1,1-diphenyl-2picryl-hydrazyl (DPPH) radical scavenging activity and ferric reducing/antioxidant power (FRAP) were also performed. The group of 35% CGL had higher total phenolic compounds than others, and the result of DPPH radical scavenging activity was similar to that of total phenolic compounds. In addition, 35% CGL is comparable to the FRAP of coffee water extract (CE). Qualitative and quantitative analysis using high-performance liquid chromatography (HPLC) were performed, and chlorogenic acid as a ployphenolic compound and caffeine as a nonpolyphenolic compound were detected in all samples. Moreover, the HPLC analysis showed that CGLs contain a larger amounts of chlorogenic acid (difference of 0.3~10.5%) and also greater amounts of caffeine (difference of 10.0~18.2%) more then CE. Consequently, these results suggest that coffee-ground as coffee by-products could be used as commercially available food substances because of its physiological molecules remained.

Effect of Grass Filter Strips on PO4-P and Soil Loss in Runoff from Forage Cropland (사료작물 재배지에서 초지식생대가 PO4-P 및 토양유실 저감에 미치는 영향)

  • Jo, Nam-Chul;Yoon, Sei-Hyung;Kim, Ki-Young;Lee, Ki-Won;Kim, Meng-Jung;Yook, Wan-Bang;Jung, Min-Woong
    • Journal of The Korean Society of Grassland and Forage Science
    • /
    • v.30 no.4
    • /
    • pp.309-316
    • /
    • 2010
  • The performance of grass filter strips (GFS) in reducing $PO_4$-P concentrations and soil loss from the forage cropland was tested in an experiment on the 10% slope in Grassland and Forages Division, National Institute of Animal Science, Rural Development Administration (RDA) from October 2007 to September 2009. Forage cropland with rye-corn double cropping system receiving inorganic fertilizer or livestock manure (LM) were compared in a natural condition. The plots were hydrologically isolated in a randomized block layout of 3 treatments $\times$ 2 factors $\times$ 3 replicates. Main plots consisted of the length of GFS, such as $25\;m^2$ ($5{\times}5\;m$), $50m^2$ ($5{\times}10\;m$), $75m^2$ ($5{\times}15\;m$). Sub plots consisted of the type of LM, such as chemical fertilizer (CF), cattle manure (CM) and swine manure (SM). Concentrations of $PO_4$-P in surface runoff water were reduced as the length of GFS increased. Especially, GFS with 10 m and 15 m reduced $PO_4$-P concentrations significantly compared to that with 0 m (p<0.05). However, there was not significant different between $PO_4$-P concentrations of GFS with 10m and that of GFS with 15 m. Moreover, Soil loss in surface runoff water were reduced as the length of GFS increased. GFS with 15 m reduced soil loss significantly compared to that with 5 m and 10 m (p<0.05). The results from this study suggest GFS improve the removal and trapping $PO_4$-P and soil loss from forage cropland.