• Title/Summary/Keyword: Water quantity

Search Result 1,454, Processing Time 0.025 seconds

A Study on the Development and Performance Evaluation of Permeable GFRP Strengthening Panel for RC Structure (투수성 GFRP 보강 복합체 개발 및 투수성에 대한 연구)

  • Jo, Byung Wan;Kang, Seok Won;Park, Cheol;Kim, Jang Wook
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.17 no.3
    • /
    • pp.65-73
    • /
    • 2013
  • Recently the exterior attaching reinforcement method is being often used by using FRP (Fiber Reinforced Polymer) as a method of strengthening concrete structure. this FRP exterior attaching reinforcement method has several advantages like high intensity, stiffness, good durability and easy installment comparing to its weight. but its structure is airtight covered by reinforcement material whose water permeability is low and water can't be discharged, thus it may provoke a damage to the structure after a long while. the main purposes of this study are to develop GFRP reinforcement material which can discharge the surface water properly and to measure its special functions. for this, we have changed the normal reinforcement material to water permeable structure and measured its water permeance modulus by an indoor test which shows the process of water permeance with the parameter of contained GFRP quantity. also tried to verify the measured value of the water permeance modulus in theory by analyzing the numbers on water permeance process. the test result showed that the biggest quantity of water, 0.5129 g/h $m^2$ was discharged when the fiber contained quantity reached at 75% and the tensile strength was also biggest by 476.6MPa at 75%, so it appeared that COSREM GP panel with 75% fiber contained quantity is the best in ventilation and structure.

Comparison of Seepage Quantity Calculated by Experiments and Finite Element Method (실험(實驗)과 FEM기법(技法)을 사용(使用)하여 구(求)한 침투유량(浸透流量)의 비교(比較))

  • Jin, Byung Ik;Kim, Jae Hong
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.5 no.2
    • /
    • pp.83-90
    • /
    • 1985
  • The thesis is established on the basis of model tests on the central core dam. With variations in the upstream water level, the quantity of seepage in the downstream boundaries were obtained for each specific water level. Seepage alignment and equipotential lines to these occasions were also researched and measured. By making use of the resulting data from the experiment, the flow velocities and seepage quantity computed to the flow rate of each element of flownets by the Finite Element Method was compared with the values produced by experiments and approximate theoretical formula. Further to this, transitions of water level related thereto was also examined in the thesis. During the high water level, seepages shown by the experiment were larger than that of the F.E.M. Meanwhile, the in-between differences were found to be quite small during the low water level. In the flow rate of each element with which the flow-nets are constructed, flow velocities of the X and Z axis were faster on account of the variations in water level. Flow velocities of the Y axis were extremely small enough to be disregarded.

  • PDF

A Study on Removal of Organic Matter and Chromaticity from Urine Using Chemical Oxidization Process (화학적 산화공정을 이용하여 소변의 색도 및 유기물 처리를 통한 재이용 기술 연구)

  • Shin, Sung-Hoon;Jung, Jong-Tai;Cho, Yong-Chul
    • Journal of Korean Society of Water Science and Technology
    • /
    • v.26 no.6
    • /
    • pp.109-115
    • /
    • 2018
  • This study was conducted to solve the water shortage problem by reclaiming urine from homes or public places and using it as cleaning water for toilets. The process used in this experiment is a chemical oxidation process combining ozone, hydrogen peroxide, and UV. We set the key substance that is to be removed as chromaticity and conducted the experiment to remove it. If the quantity or concentration of injected ozone, UV, and hydrogen peroxide is insufficient, then the chromaticity will initially increase due to low oxidizing power, and will later decrease. In addition, the efficiency of removing chromaticity appeared to be higher, depending on the quantity of ozone injected, for medium concentrated urine than highly concentrated urine. However, the absolute quantity of removed chromaticity was about 68% higher for highly concentrated urine, when 16 g/hr of ozone was injected. The higher the pH level, the reaction time and efficiency of removing chromaticity were higher, and in normal conditions, in reference to a pH of 8.55, there was a 6% difference in efficiency between a pH level of 5.05 and a pH level of 10.12. Finally, when processing urine through an ozone-only process, COD decreased steadily over time, but DOC did not decrease. This is because ozone reacts selectively with organic matter.

The Effects of BunSimGiEumGami-Bang(Fenxinqiyinjiameifang) on Serotonin of P815 cell (분심기음가미방(分心氣飮加味方)의 항산화능과 serotonin 대사에 미치는 영향)

  • Lim, Jae-Won;Jung, In-Chul;Lee, Sang-Ryong
    • Journal of Oriental Neuropsychiatry
    • /
    • v.22 no.2
    • /
    • pp.147-162
    • /
    • 2011
  • Objectives : This experiment was designed to investigate the effect of the BSGE hot water extract on serotonin biosynthesis of depression model. Methods : The cytotoxicity of the BSGE hot water extract was analyzed by MTT assay on P815 cell. The antioxidant activity was measured by DPPH free radical-scavenging activity and SOD activity on P815 cell. The quantity of 5-HT and expression of TPH-1, AAADC and MAOa mRNA was measured by of HPLC profle Analysis on P815 cell. Results : 1. The BSGE hot water extract increased DPPH free radical-scavenging activity and SOD activity on P815 cell. 2. The BSGE hot water extract increased significantly the quantity of 5-HT. 3. The BSGE hot water extract increased the expression of TPH-1 mRNA. Conclusions : This experiment shows that the BSGE hot water extract might be effective for the prevention and treatment of depression. Investigation into the clinical use of the BSGE hot water extract for depression is suggested for future research.

Improvement and Application of Total Maximum Daily Load Management System of Korea: 1. Calculation of Total Amount of Pollutant Load in the Anyangcheon Watershed (우리나라 오염총량관리제도의 개선 및 적용: 1. 안양천 유역의 오염부하량 산정)

  • Kim, Kyung-Tae;Chung, Eun-Sung;Kim, Sang-Ug;Lee, Kil Seong;Seong, Jin-Young
    • Journal of Korean Society on Water Environment
    • /
    • v.25 no.6
    • /
    • pp.972-978
    • /
    • 2009
  • This study modifies the present total maximum daily load (TMDL) system of Ministry of Environment and applies to the Anyangcheon watershed. Hydrologic Simulation Program-FORTRAN (HSPF) model is used to simulate both runoff and non-point source pollution, simultaneously, instead of QUAL2E. The drought flow (355th daily flow) is proposed for the target water quantity since it is easier to satisfy low flow (275th daily flow) for the target water quality than drought flow. The increase of discharge is more than the increase of pollutant load except for the period under low flow. The measured unit loads for non-point source are used to consider the regional runoff characteristics. The measured water quantity and quality data are used since the ministry of environment supports only water quality. This analysis results show some reasons for the improvement of the present TMDL system of Korea.

A Comparative Study on the Energy Efficiency due to the Capacity of Gas Boiler (가스온수가열기의 용량에 따른 에너지효율성 비교 연구)

  • Kim, Seong Jung;Woo, In sung
    • Journal of the Korea Safety Management & Science
    • /
    • v.17 no.2
    • /
    • pp.229-234
    • /
    • 2015
  • Depending on the living styles, the types of energy consumed by households have changed, and the consumption has increased rapidly. Consequently, those have led to environmental issues, such as exhaustion of energy and the climate changes. As one of solutions to such issues, energy efficiency can be approached. Therefore, in this study, the gas water heater(115S type Rheem products) that made in Germany and obtain hot water using gas as a heat source is selected. a $1.0m^3$ water tank with a 6kW electronic heater is installed and a water temperature and pressure is maintain constantly also thermometer is injected. Two of gas meter, one of pressure regulator and three of time measurement devices are installed in a combustion facility and fuelling facility with a magnet valve so it can observe and record combustion reactions. Quantity of hot water that heated by boiler is recorded using a quantity measurement tank, and have been heated by the boiler have been to record and measure the amount and utilized the data acquired through measurement of all factors that are applied to acquire hot water in order to calculate the use rate of final energy. In conclusion, this researcher drew the economic strong points of the hot water generated by gas.

Development of Application Method of Influent Wastewater Generation and Activated Sludge Process Design Based on Probability Density Function (확률밀도함수 기반 유입하수 재현 및 활성슬러지공정 설계기법 개발)

  • You, Kwangtae;Kim, Jongrack;Yun, Zuhwan;Pak, Gijung
    • Journal of Korean Society on Water Environment
    • /
    • v.33 no.2
    • /
    • pp.140-148
    • /
    • 2017
  • An important factor in determining the design and treatment efficiency of wastewater treatment plants (WWTPs) is the quantity and quality of influent. These detailed and accurate information is essential for process control, diagnosis and operation, as well as the basis in designing the plant, selecting the process and determining the optimal capacity of each bioreactor. Probabilistic models are used to predict the wastewater quantity and quality of WWTPs, which are widely used to improve the design and operation of WWTPs. In this study, the optimal probability distribution of time series influent data was derived for predicting water quantity and quality, and wastewater influent data were generated using the Monte Carlo simulation analysis. In addition, we estimated various alternatives for the improvement of bioreactor operations based on present operation condition using the generated influent data and activated sludge model, and suggested the alternative that can operate the most effectively. Thus, the influent quantity and quality are highly correlated with the actual operation data, so that the actual WWTPs influent characteristics were well reproduced. Using this will improve the operating conditions of WWTPs, and a proposed improvement plan for the current TMS (Tele Monitoring System) effluent quality standards can be made.

Korean Red Ginseng Protects Oxidative Injury Caused by Lead Poisoning

  • Park, Myoung-Soo;Cho, Eun-Jung;Lee, Sang-Ki;Lee, Eun-Ji;Lee, Dae-Sik;Lee, Kwon-Ho;Jeon, Byeong-Hwa
    • Journal of Ginseng Research
    • /
    • v.34 no.2
    • /
    • pp.132-137
    • /
    • 2010
  • Lead (Pb) is a metal that is generally considered to be toxic to the cardiovascular system. Pb-exposed animals display the evidence of increased oxidative stress and hypertension. The current study was designed to examine whether Korean red ginseng (KRG) has protective effects against Pb-induced hypertension and oxidative stress in Pb-exposed rats. Male Sprague-Dawley rats were randomly assigned to Pb exposure or control groups. KRG was administered in drinking water at a concentration of 100 mg/kg/day; the control group received plain drinking water. Animals in the Pb-exposed groups were provided with drinking water containing 100 ppm Pb acetate for 12 weeks. Blood pressure, plasma glutathione, blood Pb concentration, and hematologic data, such as red blood cell quantity, were determined. Pb poisoning was assessed by measuring the blood Pb concentration. Pb exposure (100 ppm) for 12 weeks resulted in a marked rise in systolic blood pressure and blood Pb concentration, as well as a significant reduction in plasma glutathione levels and red blood cell quantity. Other measurements, such as heart rate, body weight, and white blood cell quantity, were unchanged. Treatment with KRG significantly lowered blood pressure, raised plasma glutathione and increased red blood cell numbers in Pb-exposed animals; it also had no effect on heart rate, body weight, or white blood cell quantity. However, the elevated blood Pb concentration was not reduced by treatment with KRG (100 mg/kg). Taken together, these data indicate that treatment with KRG in Pb-exposed animals can reduce oxidative stress and lower blood pressure, suggesting that KRG might be protective against Pb-exposed hypertension and oxidative stress.

Effect of Micro Bubble on the High-Voiume Slag Concrete Mixed with Emulsified Refined Cooking Oil (마이크로버블이 유화처리 정제유지류(ERCO)혼입 고로슬래그 다량 치환 콘크리트의 특성에 미치는 영향)

  • Kim, Min-Yoyng;Park, Young-Jun;Baek, Doo-Hwan;Baek, Byung-Hoon;Han, Min-Cheol;Han, Cheon-Goo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2015.05a
    • /
    • pp.44-45
    • /
    • 2015
  • Although the carbonation problem of high-volume slag concrete has been solved by the mixed use of emulsified refine cooling oil as the pilot study, there was an instance of securing air quantity and frost resistance followed by the use of Expancel due to the problem of having vulnerability in frost resistance in result as the air quantity has not been secured. But due to the problem of Expancel not being economical, air quantity and frost resistance of high-volume slag concrete mixed with ERCO are attempted to be secured using micro bubble that can remain in the water for a long time as a relatively economical and very microscopic bubble.

  • PDF

A Study on Ozone Generation Characteristic using Ba-Ti-Si Ceramic Tube (Ba-Ti-Si 세라믹 방전관의 오존 발생 특성 연구)

  • 이동훈;박홍재;박재윤
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.16 no.7
    • /
    • pp.634-640
    • /
    • 2003
  • This paper is to be researched into ozone generation character of Bi-Ti-Si type high dielectric yield ceramic catalyst discharge tube. And conditions of basic experiment are the outside diameter of discharge tube : 52 mm, the length of discharge tube : 350 mm, the frequence : 900 Hz, the temperature of cooling water : 25 $^{\circ}C$, quantity of flow : 5, 10, 20 l/min, pressure : 1.2, 1.4, 1.6 atm, and distance of discharge gap : 0.4, 0.6, 0.8 mm. Ozone generation characteristics were measured to consumption power. At quantity of flow : 20 l/min, discharge gap : 0.6 mm, pressure : 1.6, and consumption power : 150 W, Maximum ozone generation efficiency of 175 g/kWh was obtained. Maximum ozone generation efficiency was measured below the flow quantity of 20 l/min at below pressure of 1.6 atm. However, Maximum ozone generation efficiency was measured over the flow quantity of 20 l/min at over pressure of 1.6 atm.