• Title/Summary/Keyword: Water purification technology

Search Result 296, Processing Time 0.024 seconds

A comparative analysis on market and technology in water industry (물산업 시장과 기술 비교분석)

  • Park, Imsu
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.35 no.6
    • /
    • pp.437-454
    • /
    • 2021
  • This study investgates Korean water technology through the water market perspective and analyses its competitiveness. Based on the water technology classification, water technology competitiveness is analysed through the technological influence index and market dominance index which are based on the extracted water technology patents from the US, Europe, Korea, and Japan for the last decade. As a result, the Korean water technology patents were lack in influence and competitiveness in global market considering the large volume of patents. There are two most tech-influential industries in Korea; manufacturing industry consisting pipes, sterilization, disinfection, and advanced water purification equipment, and construction industry including seawater desalination and water resource development. Due to the domestic usage of the patents, the Korean water technology patents scored low in global market PFS(Patent Family Size) index compared to their CPP(Cites Per Patent) index. The study is meaningful in a way that the analysis on Korean water technology competitiveness using water technology classification system and patent analysis was conducted based on the perspective of the global water market.

High Purity Ferric Oxide : Origin of Impurities and IROX-NKK Purification Process

  • Maeda, T.
    • Resources Recycling
    • /
    • v.11 no.5
    • /
    • pp.21-23
    • /
    • 2002
  • A new process based on the co-precipitation method was developed fer removing harmful impurities during Mn-Zn ferrite production such as $SiO_2$ and P from waste pickle liquor. By this process a final result of less than 100 ppm of $SiO_2$ and less than 10 ppm of P content in the ferric oxide is easily attained. Though Ca cannot be removed by this process, water rinsing of the ferric oxide is effective fer reducing Ca content to less than 100 pm. For further purification, the origins of each impurity must be investigated and then taken away.

Simulation Method for the Flowing Water Purification with UV Lamp (자외선램프을 이용한 유수처리장치 설계 시뮬레이션)

  • Jeong, Byeong-Ho;Lee, Kang-Yeon
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.23 no.9
    • /
    • pp.17-23
    • /
    • 2009
  • Interest in application of ultraviolet light technology for primary disinfection of potable water in drinking water treatment plants has increased significantly in recent years. The efficacy of disinfection processes in water purification systems is governed by several key factors, including reactor hydraulics, disinfectant chemistry, and microbial inactivation kinetics. The objective of this work was to develop a computational fluid dynamics(CFD) model to predict velocity fields, mass transport, chlorine decay, and microbial inactivation in a continuous flow reactor. The CFD model was also used to evaluate disinfection efficiency in alternative reactor designs. In a typical operation, water enters the inlet of a UV lamp and flows through the annular space between the quartz sleeve and the outside chamber wall. The irradiated water leaves through the outlet nozzle. In this paper, it describe the how to design optimal ultraviolet disinfection device for ground water and rainwater. To search the optimal design method, it was performed computer simulation with 3D-CFD discrete ordinates model and manufactured prototype. Using proposed design method, performed simulation and proved satisfied performance.

Anaerobic Digester Gas Purification for the Fuel Gas of the Fuel Cell (연료전지 연료가스인 하수처리장 소화가스정제)

  • Lee, Jong-Gyu;Jun, Jae-Ho;Park, Kyu-Ho;Choi, Doo-Sung;Park, Jae-Young
    • Journal of Hydrogen and New Energy
    • /
    • v.18 no.2
    • /
    • pp.164-170
    • /
    • 2007
  • The Tancheon wastewater treatment plant(WWTP) in Seoul using anaerobic digestion to reduce the outlet sludge produces anaerobic digester gas which contains 65% $CH_4$ and 35% $CO_2$. The gas purification equipment was installed and operated to use Anaerobic Digester Gas(ADG) as a fuel for molten carbonate fuel cell(MCFC). The processes consist of the desulfurizer and the adsorption tower to remove $H_2S$ and siloxane in the gas. The gas purification equipment removed virtually over 95% of $H_2S$ and over 99% of siloxane. Results has demonstrated that the fuel cell can produce electrical output and hot water with negligible air emissions of CO, NOx and $SO_2$. The site provides the first opportunity in Korea for demonstrating Molten carbonate fuel cell(MCFC) which the digester gas was applied to the fuel gas.

Techniques for Characterizing Surface Deterioration of Epoxy Exposed to Ozone Damage (오존에 노출된 에폭시 코팅재의 표면 열화특성 평가기술)

  • Choi, Sung-Min
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.18 no.3
    • /
    • pp.167-177
    • /
    • 2014
  • New technologies for water purification are continuously emerging to address global water quality problems, and one such technology involves advanced hermetic water purification facilities made by concrete that utilize ozone treatment processes. Better knowledge about surface deterioration of epoxy coating exposed to ozone treatment is needed as a foundation for development of improved methods and materials in the future. This study utilized atomic force microscopy (AFM), nanoindentation methods, and existing indirect methods such as visual observation, changes in mass, surface observation and chrominance analysis, to evaluate epoxy water-resistance and anti-corrosiveness. This study considered six different epoxy formulations to assess typical degradation characteristics of epoxy surfaces with regard to water-resistance/anti-corrosiveness. AFM and nanoindentation techniques emerged as promising direct methods with potential to provide quantitative measures of surface quality that are improvements upon existing indirect methods. The experiments also confirmed that some of the epoxy-coatings were severely iMPacted by ozone exposure, and thus the results demonstrate that concern about such deterioration is justified.

The Psychological Relaxation Effects of College Students in Location Targeting Seonyudo Park in Autumn (가을철 선유도공원의 주제공간이 대학생들의 심리적 안정에 미치는 영향)

  • Yoon, Yong-Han;Oh, Deuk-Kyun;Kim, Jeong-Ho
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.43 no.2
    • /
    • pp.13-22
    • /
    • 2015
  • The study discovers mood state and enhancement effect of users by scenery of location targeting Seonyudo Park; where is widely recognized as the representative recycling environmental park as well as theme experience space and scenery admiration in Korea. Also, the influence level of park and thematic space upon wellness was researched for future park design and its base data. As a result of semantic differential(SD), the most items showed low point in positive way when people admiring the scenery in Seonyudo. Also, a subject experienced differently depending on each inside scenery element of the park. As a result of profile of mood states(POMS), a tension and anxiety points were shown in order of Urban (7.78) > Water Purification Basin(3.33) > Gardens of Water Plants(2.11) > Garden of Green Pillar(2.00) > Garden of Time (0.89). The depression points were shown in order of Urban(4.94) > Water Purification Basin(3.50) > Garden of Green Pillar(2.94) > Garden of Time(1.61) > Gardens of Water Plants(1.38). The anger and hostility points were shown in order of Urban(4.22) > Water Purification Basin(3.33) > Garden of Green Pillar(2.22) > Garden of Time(1.39) > Gardens of Water Plants(1.11). The fatigue points were shown in order of Urban(6.5) > Water Purification Basin(3.39) > Garden of Green Pillar(2.78) > Garden of Time(2.28) > Gardens of Water Plants (2.06). The vigor points were shown in order of Gardens of Water Plants(11.39) > Garden of Time(11.00) > Garden of Green Pillar(8.39) > Water Purification Basin(7.77) > Urban(5.28). Also, as a result of statistics analysis, difference value of scenery type is significant. The result of total emotional disturbance(TED) was analyzed in order of Urban(24.5) > Water Purification Basin(9.5) > Garden of Green Pillar(4.67) > Garden of Time(-1.39) > Gardens of Water Plants(-1.22).

Investigation on the Enhancement of Water Purification Functions in Forest Watershed (수변구역 산림에 의한 수질정화기능 증진에 관한 고찰)

  • Park, Jae-Hyeon
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.4 no.4
    • /
    • pp.72-81
    • /
    • 2001
  • This study is aimed to review the previous research accomplishments with analysis of problems and to suggest the counter plan for the watershed management and the ongoing research strategy. Phytoremediation provides a cost-effective techniques having a merit of low investment and maintenance cost. It could be one of the best techniques, which is an alternative plan to overcome economical situation and lack of experts in our country. In forest watershed affected by waste water and heavy metal pollutants should be controlled by vegetative remediation system, but the disposal techniques of harvested plant materials should be developed. Also, high degree areas of natural vegetation as a key model to recover the vegetation should be well conserved. It is important to restore forest continuity between upper stream and lower stream basin with the restoration of damaged in forest watershed. It is established to integrated protection system for land use and management plan and to natural environment evaluation methods affected by projects such as erosion control and developments in stream and forest. In addition, I suggest the continuous environmental monitoring system to treat the pollutions concerned.

  • PDF

Phosphate Adsorption Characteristics of a Filter Medium, Adphos, and Its Efficiency by the Filtration Experiment Combined with the Vegetation Mat (Adphos 여재의 인 흡착특성과 식생 매트와 결합한 여과실험에 의한 효율)

  • Kim, Ji Ah;Joo, Gwang Jin;Choi, I Song;Chang, Kwang Hyeon;Oh, Jong Min
    • Ecology and Resilient Infrastructure
    • /
    • v.3 no.4
    • /
    • pp.231-237
    • /
    • 2016
  • The purpose of this study is to analyze phosphate adsorption characteristic of the filter media applied in water purification technology. And it is also to observe the removal efficiency of the technology that was developed by combining the purification abilities of filter media and the vegetation mat. The filter media, Adphos, is the subject of this study. The result of adsorption test shows that $PO_4{^{3-}-P}$ adsorption characteristics of Adphos is determined by the Langmuir isotherm model fitting and the $q_m$ (maximum adsorption amount) value is calculated as 1.162 mg/g. To verify the removal efficiency of the purification technology, a lab-scale reactor, including a 400 mm depth of filter bed filled by Adphos, was manufactured. Yellow flag Iris (Iris pseudacours L.) was planted on the vegetation bed and the coir-roll was used to fix the root of vegetation. The reactor ran 8 hours per day over 71 days, and the results of filtration experiment show that average removal efficiency of SS, T-N and T-P were calculated as 94%, 41% and 64% respectively. With these results, it was proved that the purification technology is highly effective. And for the long-time use, a maintenance guide is also required.

Recirculating Aquaculture System Design and Water Treatment Analysis based on CFD Simulation

  • Juhyoung Sung;Sungyoon Cho;Wongi Jeon;Yangseob Kim;Kiwon Kwon;Deuk-young Jeong
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.17 no.11
    • /
    • pp.3083-3098
    • /
    • 2023
  • As demands for efficient and echo-friendly production of marine products increase, smart aquaculture based on information and communication technology (ICT) has become a promising trend. The smart aquaculture is expected to control fundamental farm environment variables including water temperature and dissolved oxygen (DO) levels with less human intervention. A recirculating aquaculture system (RAS) is required for the smart aquaculture which utilizes a purification tank to reuse water drained from the water tank while blocking the external environment. Elaborate water treatment should be considered to properly operate RAS. However, analyzing the water treatment performance is a challenging issue because fish farm circumstance continuously changes and recursively affects water fluidity. To handle this issue, we introduce computational fluid dynamics (CFD) aided water treatment analysis including water fluidity and the solid particles removal efficiency. We adopt RAS parameters widely used in the real aquaculture field to better reflect the real situation. The simulation results provide several indicators for users to check performance metrics when planning to select appropriate RAS without actually using it which costs a lot to operate.

Determination of Optimal Hourly Water Intake Amount for H Arisu Purification Center using Linear Programming (선형계획법을 이용한 H 아리수 정수 센터 최적 취수량 결정)

  • Lee, Chulsoo;Lee, Kangwon
    • Journal of Korea Water Resources Association
    • /
    • v.48 no.12
    • /
    • pp.1051-1064
    • /
    • 2015
  • Currently, the H purification plant determines the hourly water intake amount based on operator experience and skill. Therefore, inevitably, there are deviations among operators. While meeting time-varying demand and maintaining the proper water level in the clean water reservoir, the methodology for minimizing electricity cost, when dealing with different electricity rate time zones, is a very complicated problem, which is beyond an operator's capability. To solve this problem, a linear programming (LP) model is proposed, which can determine the optimal hourly water intake amount for minimizing the daily electricity cost. It is shown that an inaccurate estimate for the hourly water usage in the demand areas causes the water level constraint to be violated, which is the weak point of the proposed LP method. However, several examples with real-field data show that we can practically and safely solve this problem with safety margins. It is also shown that the safety margin method still works effectively whether the estimate is accurate or not. The operators need not attend the site at all times under the proposed LP method, and we can additionally expect reductions in labor costs.