• Title/Summary/Keyword: Water purification plant

Search Result 208, Processing Time 0.027 seconds

Treatment Efficiency of a Subsurface-Flow Wetland System Constructed on Floodplain (고수부지를 이용한 여과습지의 수질정화 초기처리)

  • Yang, Hongmo
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.4 no.4
    • /
    • pp.56-63
    • /
    • 2001
  • This paper presents treatment efficiency and plant growth of a subsurface-flow constructed wetland system (23 m in length, 6.5 m in width, 0.65 m in depth) over one year after its establishment on floodplain of a stream in June 2000. An upper layer of 10 cm in depth was filled with course sand and the main biological layer of 50 cm depth with crushed stone with 8 - 15 mm in diameter. The system was planted with common reeds (Phragmites australis) grown on pots. Effluent discharged from a secondary-level treatment plant was funneled into it. Reed stems emerging in April 2001 grew up to 145.9cm until July 2001. The number of reed stems in July 2001 increased by about 11 times compared with that just after planting. The system was inundated seven times by storms over the monitoring period. Reeds were slightly bent after flooding, however they returned to almost upright standing in a couple of weeks. Small portion of inside slope of berm was eroded and the system surface had a sedimentation of 2 - 3 mm in depth. The average removal rates for SS, $BOD_5$, T-N and T-P was 73%, 70%, 53%, and 72%, respectively. The purification efficiencies for SS and $BOD_5$ were fairly good. The reduction rates for T-N was relatively low for the period of late fall through winter until early spring due to lower water temperature which retarded microbial nitrification and denitrification mechanisms. Reduction in the concentration of T-P during fall and winter was relatively higher than that during spring. Leach of phosphorous from plant litters lying on system surface and slight resuspension of precipitated phosphorous in substrates resulted in lower reduction for T-P in spring.

  • PDF

Evaluation of Toxicity for Commercial Red Mud Pellets Using Pseudokirchneriella subcapitata and Daphnia magna

  • Lee, Saeromi;Ahn, Chang Hyuk;Park, Jae Roh;Lee, Sooji;Lee, Inju;Joo, Jin Chul
    • Ecology and Resilient Infrastructure
    • /
    • v.2 no.4
    • /
    • pp.345-350
    • /
    • 2015
  • The toxicity of red mud (RM) pellets for water purification was evaluated using Pseudokirchneriella subcapitata and Daphnia magna in a lab-scale experiment. According to the algal growth inhibition test, both specific growth rates and relative growth rates of P. subcapitata decreased, and the growth inhibition rates increased ($R^2=0.97$, p<0.001) as the concentration of RM pellets in the aqueous solution increased (>1.6 g/L). Also, based on the acute toxicity evaluation test on D. magna, toxic unit (TU) values ranged between 0.00 and 2.83, and increased with an increase in the concentration of RM pellets in the aqueous solution. A correlation analysis indicated that the pH of RM pellets was statistically correlated with TU values ($R^2=0.77$, p=0.02). The environmental implication from this study is that the concentration of RM pellets in an aqueous solution needs to be lower than 4.4 g/L to keep the maximum permissible TU value less than 1.0.

Radioresistance of Acorus calamus to Gamma Ray Irradiation

  • Lee, Ja-Hyun;Kang, Si-Yong;Lee, Geung-Joo;Lee, Seong-Gene;Kim, Sun-Kook;Han, Tae-Ho
    • FLOWER RESEARCH JOURNAL
    • /
    • v.19 no.2
    • /
    • pp.119-125
    • /
    • 2011
  • Acorus calamus is an indigenous hydrophyte used as phytoremediation and water purification as well as medicinal herb. Irradiation of gamma ray was performed to investigate the effect on radioresistance of A. calamus on in vitro. Various doses (20-500 Gy) of gamma rays were irradiated to in vitro plantlets. The effect of irradiation was studied on survival rate, shoot formation and growth rate. The survival and multiplication rate was remarkably decreased with the increase of radiation dose. The growth of plantlets was significantly increased in comparison to the control at low doses. The hermetic effect of radiation was appeared in A. calamus. It was significantly decreased or interrupted above 250 Gy. The mean 50% lethal dose ($LD_{50}$) was extremely high as 240 Gy. We conclude that A. calamus had remarkably high radioresistance compared with other plant species.

Characteristic recovery of active carbon waste treated by microwave (Microwave에 의한 정수장 폐활성탄의 복원 특성)

  • Lee, Bum-Suk;Kim, Taik-Nam;Kim, Jong-Ock
    • The Journal of Engineering Research
    • /
    • v.4 no.1
    • /
    • pp.93-107
    • /
    • 2002
  • The active carbon waste which was used in water purification plant was investigated for the improvement of capillary after microwave treatment. The variation of surface area was measured with the various kinds and amounts of active carbon. The water vapor as the activator was verified to improve the capillary but it reacted with the water contained in waste active carbon. In contrast to the water vapor, the $CO_2$ gas improved the surface area about 10-20 % compared to as received one. The best results was observed at the intensity of 2.75 kw microwave. The more effective recovery of active carbon waste was observed at the microwave treatment compared to the rotary kiln treatment. However, the mass production is so difficult in the microwave process.

  • PDF

Analysis and risk assessment of formaldehyde in water from water purification plant in korea (국내 정수장 먹는 물 중 폼알데히드 함유실태 조사 및 위해성 평가 연구)

  • Chae, Hyojin;Kim, Hyun Ku;Kim, Seungki;Pyo, Heesoo;Hong, Jongki
    • Analytical Science and Technology
    • /
    • v.22 no.5
    • /
    • pp.386-394
    • /
    • 2009
  • Formaldehyde is used in lether manufacture, a dry plate and an explosive. It is by-product of ozonizing process in filtration plant. The effects of exposure are eye pruritus, tickle, runing nose, blocking nasal passages and headache. It also makes a dried throat and causes inflammation. It is classified as B1 group for inhalation by US. EPA, which can cause cancer in human. For analysis of formaldehyde, formaldehydes-DNPH derivative was extracted with solid cartridge and was analyzed by High Performance Liquid Chromatography/Diode Array Detector (HPLC/DAD). The detection limit was $3{\mu}g/L$ and the recoveries were 72.3~109.1% (RSD 2.9~11.5%). Water samples were collected in four Korean rivers, four times per year seasonally for 10 years from 1998 to 2007. The monitoring results were 48.8% (630/1291), $5.15{\sim}101.9{\mu}g/L$ in purified water. Because of non-carcinogen in drinking water, hazard index is calculated with RfD. Results of excess cnacer risk was below 1 and was considered as safe value.

Establishment of analytical method of methiozolin and dissipation in golf course's green (Methiozolin의 분석법 개발 및 골프장 그린에서의 잔류소실특성)

  • Jo, Hyeong-Wook;Hwang, Kyu-won;Hwang, Ki-Hwan;Moon, Joon-Kwan
    • Journal of Applied Biological Chemistry
    • /
    • v.59 no.4
    • /
    • pp.331-336
    • /
    • 2016
  • Analytical methods for methiozolin in soil, water and turfgrass were established and dissipation patterns of methiozolin in soil and turfgrass were elucidated. Analysis was done using a high performance liquid chromatography with an ultra violet detector at the wavelength of 280 nm after extraction with acetone, liquid-liquid partition with dichloromethane, and a solid phase extraction purification. Limit of determination and Limit of quantitation were 1.0, 0.5, 1.0 ng, and 0.001, 0.1, 0.01 mg/kg for water, turfgrass, and soil, respectively. Recovery rates of methiozolin from soil, water, and turfgrass were ranged 87.5~111.3, 92.8~97.4, and 78.2~98.5 %, respectively. The turfgrass and soil samples were collected at 0, 1, 4, 7, 14, 30, 45, and 60 after spray on green area in golf course. Residues of methiozlolin were not translocated to lower soil layer but detected only in turfgrasses and root area of turfgrass. Half-lives of methiozolin in turfgrass were 10.7 days and 8.8 days in soil from root area.

A Study on the Correlation between Odorous Compounds, Actinomycetes and Algae in Drinking Water Source of Nakdong River (낙동강 상수원수 중 이취물질과 방선균 및 조류의 상관관계 연구)

  • Kim, Jeong-A;Kim, Gyeong-A;Yun, Churl-Jong;Park, Hong-Gi;Jung, Eun-Young;Cha, Dong-Jin;Choi, Jin-Taek;Son, Hee-Jong
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.35 no.3
    • /
    • pp.213-219
    • /
    • 2013
  • We have investigated the correlation between odorous compounds and actinomycetes in drinking water source of Nakdong River in 2011. Geosmin was mainly detected in the spring and summer seasons (Mar, Aug, and Sep) and 2-MIB was mainly detected in the winter and spring seasons (Feb, Mar and May). The odorous compounds concentrations were highest on March which also overlapped with the peak of actinomycetes, geosmin and 2-MIB were detected highly in the diluted culture solution of isolated actinomycetes strains from Nakdong River. For these reasons we could confirm that odorous compounds on March and August are closely related with actinomycetes. Meanwhile, geosmin increase on September supposed to relate with Microcystis.

Development of a predictive model of the limiting current density of an electrodialysis process using response surface methodology

  • Ali, Mourad Ben Sik;Hamrouni, Bechir
    • Membrane and Water Treatment
    • /
    • v.7 no.2
    • /
    • pp.127-141
    • /
    • 2016
  • Electrodialysis (ED) is known to be a useful membrane process for desalination, concentration, separation, and purification in many fields. In this process, it is desirable to work at high current density in order to achieve fast desalination with the lowest possible effective membrane area. In practice, however, operating currents are restricted by the occurrence of concentration polarization phenomena. Many studies showed the occurrence of a limiting current density (LCD). The limiting current density in the electrodialysis process is an important parameter which determines the electrical resistance and the current utilization. Therefore, its reliable determination is required for designing an efficient electrodialysis plant. The purpose of this study is the development of a predictive model of the limiting current density in an electrodialysis process using response surface methodology (RSM). A two-factor central composite design (CCD) of RSM was used to analyze the effect of operation conditions (the initial salt concentration (C) and the linear flow velocity of solution to be treated (u)) on the limiting current density and to establish a regression model. All experiments were carried out on synthetic brackish water solutions using a laboratory scale electrodialysis cell. The limiting current density for each experiment was determined using the Cowan-Brown method. A suitable regression model for predicting LCD within the ranges of variables used was developed based on experimental results. The proposed mathematical quadratic model was simple. Its quality was evaluated by regression analysis and by the Analysis Of Variance, popularly known as the ANOVA.

Design of Multivariable 2-DOF PID for Electrical Power of Flow System by Neural Network Tuning Method (신경망 튜우닝에 의한 유량계통 동력 제어용 다변수 2-자유도 PID의 제어기 설계)

  • 김동화
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.12 no.1
    • /
    • pp.78-84
    • /
    • 1998
  • The fluid system such as, the quantity control of raw water, chemicals control in the purification, the waste water system as well as in the feed water or circulation system of the power plant and the ventilation system is controlled with the valve and moter pump. The system's performance and the energy saving of the fluid systems depend on control of method and delicacy. Until, PI controller use in these system but it cannot control delicately because of the coupling in the system loop. In this paper we configure a single flow system to the multi variable system and suggest the application of 2-DOF PID controller and the tuning methods by the neural network to the electrical power of the flow control system. the 2-DOF controller follows to a setpoint has a robustness against the disturbance in the results of simulation. Keywords Title, Intelligent control, Neuro control, Flow control, 2 - DOF control., 2 - DOF control.

  • PDF

Identification of ${\gamma}-Glutamylamine$ Cyclotransferase, as the Preform Enzyme at the Dormant Stage, From Soybean (Glycine max) Seeds

  • Kang, Hyeog;Park, Sung-Joon;Cho, Young-Dong
    • BMB Reports
    • /
    • v.30 no.6
    • /
    • pp.438-442
    • /
    • 1997
  • ${\gamma}-Glutamylamine$ cyclotransferase was purified to homogeneity from soybean (Glycine max) seeds. To our knowledge, it is the first purification of the enzyme from plant origins. The molecular weight of the enzyme estimated by Sephacryl S-300 gel filtration and SDS-PAGE was 27,000, indicating that the enzyme is a monomer. The optimal pH for activity was 8.6. The Km value for ${\gamma}-glutamyldansylcadaverine$ was 11 ${\mu}M$. The enzymatic activity was substantially inhibited by the addition of p-chloromercuribenzoate and partially inhibited by the $Cu^{2+}$ ion. However, neither other modification reagents nor other divalent metal ions affected the enzymatic activity. The comparison between the enzymatic activities of seed extracts treated with cycloheximide and control extracts, and the detection of the same single protein band by western blot analysis at the dormant stage without inhibition with distilled water indicate that ${\gamma}-Glutamylamine$ cyclotransferase is already present at the dormant stage and gradually activated during germination in soybean seeds.

  • PDF