• 제목/요약/키워드: Water pressure reduction

검색결과 375건 처리시간 0.024초

제주시 상수도 관망 블록시스템 구축을 통한 누수 저감 (Leakage Reduction through Establishment of Block System in Jeju City)

  • 차준호;김진근
    • 상하수도학회지
    • /
    • 제26권5호
    • /
    • pp.693-703
    • /
    • 2012
  • Leakage in water supply system can cause water resources loss in addition to the water quality degradation. In this research, leakage reduction after establishment of a block system in the area with leakage rate of 69.0 % was investigated using EPANET simulation. The average water pressure for the research area was $5.17kgf/cm^2$ which was relatively high, and several sites were deviated from recommended water pressure ranges(i.e., 1.5 ~ $7.1kgf/cm^2$). However, the average water pressure in the area was reduced to 3.81 and $3.49kgf/cm^2$ after the introduction of block system with a water pressure relief valve(PRV) setting of 3.0 and $2.5kgf/cm^2$, respectively. Under the installation of a PRV with regulating pressure of $2.5kgf/cm^2$, the predicted leakage was reduced from $4,420.3m^3/d$ to $3,028.1m^3/d$, which was equivalent to the leakage reduction from 31.0 % to 23.5 %.

전해수를 이용한 견섬유 정련 및 세리신 회수(II)-분리막에 의한 세리신 농축을 중심으로- (The Degumming and Sericin Recovery of the Silk fabric Using the Electrolytic Water(II))

  • 배기서;이태상;노덕길;홍영기
    • 한국염색가공학회지
    • /
    • 제16권4호
    • /
    • pp.10-18
    • /
    • 2004
  • In this work, Aqueous sericin solution was prepared by degumming process with electrolytic reduction water. Then, the microfiltration and ultrafiltration systems were applied to the concentration of aqueous sericin solution. The objective of this study was to select the optimum operating condition among the different pressure. The permeate flux and rejection ratio were observed with time, pressure, flow rate and concentration. and, the wastewater and permeated water quality values such as pH, BOD, COD, and NH levels were measured. In order to see the influence of electrolytic reduction water, the flux of pure water and electrolytic reduction water by PVDF22(MF) and PS100(UF) membrane was measured. In microfiltration system, the relative flux reduction decreased rapidly to 0.02 in the 30min, as the concentration polarization and gel layer formation were increased. and then the sericin concentration rejection ratio was 40%. In ultrafiltration system, the permeate flux decreased with time and concentration, and increased with the operating pressure and flow rate. Optimal condition in PS100 membrane system for sericin concentration was operating pressure 1.464kgf/$cm^24, operating flow rate $7\ell/min at\; 40^{\circ}C$. At that time, sericin concentration rejection ratio was 83% respectably. The sericin solution was concentrated from 0.1wt% solution to 0.2 wt % solution during about 2 hrs by the UF filteration membrane system.

Influence of the Water Vapor Content on the Hydrogen Reduction Process of Nanocrystalline NiO

  • Jung, Sung-Soo;An, Hyo-Sang;Lee, Jai-Sung
    • 대한금속재료학회지
    • /
    • 제48권4호
    • /
    • pp.315-319
    • /
    • 2010
  • In this study, the hydrogen reduction behavior of ball-milled NiO nanopowder was investigated depending on the partial pressure of water vapor. The hydrogen reduction behavior was analyzed by thermogravimetry and hygrometry under heating to 873 K in hydrogen. In order to change the partial pressure of the water vapor, the dew point of hydrogen was controlled in the range of 248 K~293 K by passing high-purity hydrogen through a saturator that contained water. Interestingly, with the increase in the dew point of the hydrogen atmosphere, the first step of the hydrogen reduction process decreased and the second step gradually increased. After the first step, a pore volume analysis revealed that the pore size distribution in the condition with a higher water vapor pressure shifted to a larger size, whereas the opposite appearedat a lower pressure. Thus, it was found that the decrease in the pore volume during the chemical reaction controlled process at a dew point of 248 K caused a reduction in retardation in the diffusion controlled process.

지역냉방시스템에의 적용을 위한 마찰저항감소 첨가물 특성 연구 (Characteristics of Drag Reduction Additives in the Application of District Cooling System)

  • 윤석만;김종보
    • 설비공학논문집
    • /
    • 제12권3호
    • /
    • pp.251-257
    • /
    • 2000
  • District heating and cooling systems offer highly efficient energy utilization and maintenance by centralizing heat management. More pumping power, however, is required because the water has to travel long distance from heat source to the users. In the present study, a trace of drag reduction additives is added to the District Cooling system to achieve a significant drag reduction and save pumping power. Water-soluble polymers, surfactants, and environment-friendly degradable polymers are used as effective drag reducing additives. Time dependent percent drag reductions are compared for various additive solutions at 100 wppm concentration for different water velocity. Without as an anionic surfactant, copolymer was most effective in percent drag reduction. It is found that there exists an optimal condition when copolymer is mixed with SDS. An environment-friendly degradable polymer, xanthan gum, is found to be a significant drag reduction additive. Ice slurry systems, can give less pressure drops compared with chilled water system for certain condtions. Drag reduction additives were also effective for the ice slurry system.

  • PDF

상수도 급수방식 전환의 타당성 분석 및 최적 범위 산정모델 연구 (A Study on Feasibility Analysis and Optimum Range Calculation Model by Conversion of Water Supply System)

  • 박준열;신휘수;서지원;김기범;구자용
    • 상하수도학회지
    • /
    • 제31권2호
    • /
    • pp.177-186
    • /
    • 2017
  • This study concerned the analysis on the efficiency of the conversion of water tank type supply system to direct water supply system to examine the feasibility of the conversion, as well as the calculation of optimal conversion range that enables the supply of safe, high-quality water at stable pressure in accordance with the standards of water supply facility. The results of this research showed that when converting water supply system from water tank type supply system to direct water supply system, more nodal points could be properly converted and more reduction of electricity usage was expected in case water pressure rather than residence time was fixed. This means that higher efficacy can be obtained by fixing water pressure when converting water supply system. However, since the number of the locations that received on-spot inspection was small and the electricity usage measured was not exclusively by water supply facility, it is difficult to judge that such reduction of electricity usage accurately represents reduced electricity usage by water supply facility alone. therefore, after having secured on-spot information about a larger number of locations in apartment complexes that have converted water supply system, and utilizing information about electricity usage exclusively by water supply facility, the proposed method of this research could be applied to accurately deducing expected reduction of electricity usage by water supply facilities of various other apartment complexes. It is also considered possible to deduce an effective operation method of water supply system by finding out an area that shows low pressure or low residual chlorine concentration in the optimal conversion range of water supply, followed by estimating the proper location of pumping station or the proper chlorine dosage at the power purification plant that supply water to the target area.

NCM계 리튬이온 배터리 양극재의 수소환원 거동 (Hydrogen Reduction Behavior of NCM-based Lithium-ion Battery Cathode Materials)

  • 이소영;이소연;이대현;손호상
    • 한국분말재료학회지
    • /
    • 제31권2호
    • /
    • pp.163-168
    • /
    • 2024
  • As the demand for lithium-ion batteries for electric vehicles is increasing, it is important to recover valuable metals from waste lithium-ion batteries. In this study, the effects of gas flow rate and hydrogen partial pressure on hydrogen reduction of NCM-based lithium-ion battery cathode materials were investigated. As the gas flow rate and hydrogen partial pressure increased, the weight loss rate increased significantly from the beginning of the reaction due to the reduction of NiO and CoO by hydrogen. At 700 ℃ and hydrogen partial pressure above 0.5 atm, Ni and Li2O were produced by hydrogen reduction. From the reduction product and Li recovery rate, the hydrogen reduction of NCM-based cathode materials was significantly affected by hydrogen partial pressure. The Li compounds recovered from the solution after water leaching of the reduction products were LiOH, LiOH·H2O, and Li2CO3, with about 0.02 wt% Al as an impurity.

수압에 의한 암반의 물성 저하가 갱도의 안정성에 미치는 영향 (Effect of Degradation of Rock Mass Properties Caused by Water Pressure on the Stability of Mine Gallery)

  • 윤용균;백영준;조영도
    • 터널과지하공간
    • /
    • 제21권2호
    • /
    • pp.138-144
    • /
    • 2011
  • 광산이 폐광을 하는 경우 배수시스템을 정지함으로 인해 갱도는 물로 포화된다. 갱도가 포화되었을 때 갱도 주변의 암석은 완전히 포화되고 갱도 주변 암반에는 수압이 작용한다. 암석의 일축압축강도는 함수율에 따라 달라지며 함수율이 증가함에 따라 감소한다. 수압은 암석 내 균열이나 암반 내 불연속면의 확장을 유발하게 된다. 갱도 내 포화된 수압이 지보압을 발휘할 수도 있지만 지하수에 의해 발생한 암반 물성의 저하는 갱도의 안정성을 감소시킬 것이다. 본 연구에서는 수압에 의해 발생한 갱도 주변 암반의 물성 저하가 갱도의 안정성에 미치는 영향을 평가하기 위하여 2차원 불연속해석과 3차원 연속해석을 실시하였다. 수치해석 결과 수압에 의해 유발된 갱도 주변 암반의 물성 저하는 갱도 주변 암반의 변위 증가에 영향을 미치고, 2차원 해석 결과는 3차원 해석 결과 보다 큰 변위를 나타냈다.

전산유체역학을 이용한 워터펌프 축력 저감 (Reduction of the Axial Force of Water Pump Using CFD)

  • 조석현;신동성
    • 한국자동차공학회논문집
    • /
    • 제20권3호
    • /
    • pp.83-87
    • /
    • 2012
  • Computational Fluid Dynamics (CFD) method has been used to investigate the axial force of automotive water pump. As the excessive axial force can make some unexpected problems like impeller interference and coolant leakage we have focused on finding the cause of axial force and its reduction in this paper. First, we have tested the closed type water pump with and without balance hole by the calculation methods. By examining the pressure contour around the impeller, we have found that the axial force arises not only from the pressure difference around shroud but also from the pressure difference around hub. So we have tested two impellers - one is normal open type impeller and the other is open type impeller with modified hub. The results show that the axial force reduction is about 150~200N for normal one and 700N@3000RPM for modified impeller. And the hydraulic efficiency which is important in aspect of engine fuel efficiency is reduced about 6.5% for normal one but increased 4%@3000RPM for modified impeller.

습식 부항 시술시 사혈량에 따른 부항 탈락 위험도 탐색 (Change in Risk of Dropout Due to Bleeding during Bloodletting-Cupping Therapy)

  • 김대혁;배은경;박정환;김소영;이상훈
    • Korean Journal of Acupuncture
    • /
    • 제35권1호
    • /
    • pp.41-45
    • /
    • 2018
  • Objectives : To investigate minimum pressure by verifying changes in pressure due to bleeding amount during bloodletting-cupping therapy. Methods : (1) We compared adhesion performance of four different cupping cups of same size: two disposable cupping cups(A, B) and two reusable cupping cups(A, B) each were vacuumed three times and kept in place for 10 minutes. (2) We vacuumed two different sized disposable cupping cups(A), size.1(InnerDiameter 48.8 mm) and size.3(InnerDiameter 39.1 mm), twice each(-200 mmHg) on silicon plate. We injected water and air at regular intervals in cupping cups by using a syringe, and then measured change of pressure in cupping cups and pressure at the time of dropout. Results : (1) Pressure reduction was $4.75{\pm}2.78%$ on average in the order of 'Disposable[A]>reusable[B]>Disposable[B]>reusable[A]', so that pressure retention performance of disposable cups can't be regarded as inferior to that of reusable cups. (2) Pressure of disposable cupping B(size.1) decreased by an average of -40.08 mmHg per 5 ml of water. At -24.8 mmHg, when 22 ml of water has been injected, cup has come off. Pressure of disposable cupping B(size. 3) decreased by an average of -99.4 mmHg per 5 ml of water. At -48.6 mmHg, when 13 ml of water was injected, cupping came off. Conclusions : Considering reduction rate of pressure due to water injection, in case of bleeding more than 15 ml, size.3 cup always comes off, therefore it needs to be re-operated at least once. Meanwhile, size.1 cup does not always come off in the same condition, depending on the initial pressure and therefore, re-operation may be considered.

발수제 처리 소나무재의 치수안정성 (Dimensional Stability of Korean Red Pine Treated with Water Repellents)

  • 한규성
    • 한국가구학회지
    • /
    • 제19권3호
    • /
    • pp.172-179
    • /
    • 2008
  • The objective of this study was to investigate the influence of the water repellents' treatment on the water absorptivity and the dimensional stability of Korean red pine wood(Pinus densiflora). The alkylketene dimer(AKD), fluororesin emulsion(Wood-seal, WS), and paraffin wax emulsions(PW25, PW40, and PW1200) were used as water repellents. PW40 and WS were proved as excellent water repellents for pine wood, because the samples treated with these agents showed high contact angles and large reduction in water absorptivities. Also, the dimensional stability(antiswelling efficiency) of pine wood was considerably improved by water repellents treatments, such as PW40 and WS at the pressure of 2MPa. The water repellent treated woods with WS, PW40, and PW1200 at the pressure of 2MPa were relatively stable to the wet-dry cyclic leaching test.

  • PDF