• Title/Summary/Keyword: Water pipes

검색결과 701건 처리시간 0.026초

연질 PE관을 이용한 여름딸기 부분냉방기술 개발 (Spot Cooling System Development for Ever-bearing Strawberry by Using Low Density Polyethylene Pipe)

  • 문종필;강금춘;권진경;이수장;이종남
    • 한국농공학회논문집
    • /
    • 제56권6호
    • /
    • pp.149-158
    • /
    • 2014
  • The effects of spot cooling on growing ever-bearing strawberry in hydroponic cultivation during summer by spot cooling system was estimated in plastic greenhouse located in Pyeongchang. The temperature of cooling water was controlled by heat pump and maintained at the range of $15{\sim}20^{\circ}C$. Cooling pipes were installed in root zone and very close to crown. Spot cooling effect was estimated by applying system in three cases which were cooling root zone, crown plus root zone, and crown only. White low density polyethylene pipe in nominal diameter of 16 mm was installed on crown spot, and Stainless steel flexible pipe in nominal diameter of 15A was installed in root zone. Crown and root zone cooling water circulation was continuously performed at flowrates of 300 ~ 600 L/hr all day long. Strawberry yields by test beds were surveyed from Aug. 1 to Sep. 30. The accumulated yield growth rate compared with a control bed of crown cooling bed was 25 % and that of crown plus root zone cooling bed was 25 % and that of root zone cooling bed was 20 %. The temperatures of root spot in root zone cooling was maintained at $18{\sim}23.0^{\circ}C$ and that of crown spot in crown cooling was maintained at $19{\sim}24^{\circ}C$. Also, the temperatures of root spot in crown plus root zone cooling bed was maintained at $17.0{\sim}22.0^{\circ}C$ and that of crown spot was maintained at $19{\sim}25^{\circ}C$.

발전소용 이중보온용 강관의 홈부식(Grooving Corrosion)에 의한 파손 분석 (The Failure Analysis of Double Pipe for Insulation Used Power Plant by Grooving Corrosion)

  • 함종오;박기덕;박성진;선일식
    • 한국신뢰성학회지:신뢰성응용연구
    • /
    • 제15권3호
    • /
    • pp.197-206
    • /
    • 2015
  • Failure analysis of pre-insulated pipe (SPPS 380, 400A) transporting high temperature water ($95{\sim}110^{\circ}C$) for a plant was carried out. The damaged area (${\Phi}5mm$) of pre-insulated pipe was found only on welds. The chemical composition of damaged pipe meets specification of carbon steel pipes for pressure service (KS D 3562). As results of microstructure analysis, crack propagated from outer to inside after pitting corrosion occurred on the outside surface. The non-metallic inclusion existed on the end of crack. And the non-metallic inclusion continuously and linearly formed along with the bond line of welds. Based on SEM-EDS analysis, the nonmetallic inclusions have higher Manganese (Mn) and Oxygen (O) content but sulfur (S) was not detected. As results of water quality analysis, hydrogen ion concentration and minerals like Fe, Mg, Si were in low level. But the content of dissolved oxygen (11.2 ppm) was slightly higher than that of standard. It seems that the cause of damaged pipe is grooving corrosion due to MnO inclusion formed on bond line and corrosion took place nearby welds.

로터형 슬러리 펌프 개발을 위한 실험적 연구 (Experimental Investigation of the Development of a Rotor Type Slurry Pump)

  • 박상규;윤재근;양희천
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제39권4호
    • /
    • pp.456-462
    • /
    • 2015
  • 본 연구는 토네이도와 축류펌프의 원리를 적용하여 마중물 없이 슬러리를 송출할 수 있는 새로운 펌프기술 개발을 목적으로 한다. 개발한 로터형 슬러리 펌프는 전동모터, 구동축 및 커플링, 로터, 임펠러 그리고 흡입 및 송출관으로 구성된다. 청수를 이용한 성능실험에서는 로터의 설계조건에 따른 송출량, 소비 전력량 그리고 흡입관 부압특성에 대해 모터의 회전수를 변수로 검증하였으며, 시멘트를 이용하여 제조한 슬러리의 고형물 농도에 따른 송출량 특성에 대한 검증연구를 수행하였다. 로터의 직경과 높이가 커지면 송출량과 소비되는 전력량은 증가하지만 흡입관 부압은 감소하였으며, 송출량과 부압에 미치는 로터 두께의 영향은 거의 나타나지 않았다. 개발지표로 제시하였던 18 % 이상의 고형물 농도에서도 슬러리의 송출이 가능함을 확인하였다.

화력발전소의 온배수를 열원으로 이용하는 시설원예 난방용 히트펌프 시스템의 열교환기 설계기준 설정 (Heat Exchanger Design of a Heat Pump System Using the Heated Effluent of Thermal Power Generation Plant as a Heat Source for Greenhouse Heating)

  • 유영선;강연구;장재경;김영화;김종구;강금춘
    • 생물환경조절학회지
    • /
    • 제21권4호
    • /
    • pp.372-378
    • /
    • 2012
  • 본 연구에서는 화력발전소에서 온배수의 형태로 배출되는 폐열을 히트펌프의 열원으로 이용하여 온실의 난방에 활용할 수 있는 히트펌프 시스템을 설계 제작하였으며, 난방 성능을 분석하여 PE 파이프 열교환기의 설계기준을 제시하고자 하였다. PE 파이프 열교환기의 내경은 20mm, 두께는 2mm였으며, Roll의 직경은 1,000mm로 하였다. 연구결과 PE파이프 열교환기의 적정 길이는 1.0RT당 75m로 설계하는 것이 바람직할 것으로 판단되었으며, 이때 히트펌프시스템의 난방성능계수(COPh)는 3.8로 나타났다.

GPR 탐사 데이터의 이미지 처리 (Image Processing of GPR Detection Data)

  • 이현호
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제20권4호
    • /
    • pp.104-110
    • /
    • 2016
  • 본 연구에서는 매립관 및 공동에 대한 GPR 탐사의 실증적 자료 확보 및 GPR 탐사 자료의 이미지 처리를 위한 프로그램을 개발하기 위한 토조의 GPR 탐사를 시행하였다. 비포장 및 아스팔트 포장의 경우 심도 0.7m에서 물채움 공동을 확인할 수 있었으나, 1.0 m 및 1.3 m 깊이에 매립한 공동은 탐지 불가하였다. 무근 및 철근 콘크리트 포장의 경우 신호의 간섭이 심하여 공동을 탐지하는 것이 어려웠다. GPR 탐사 데이터의 이미지 처리를 위한 프로그램 GPRiPP을 개발하였다. 주요한 처리 기법인 백그라운드 제거, 스택킹 및 게인 기능 알고리즘을 프로그램에 반영하였으며, 적절한 백그라운드 제거 및 게인 기능을 사용하면 기존 프로그램과 유사한 이미지 처리 결과를 도출할 수 있음을 확인하였다.

비스페놀류의 사용 현황과 위해성: 소고 (Current State of Use and the Risks of Bisphenols: A Minireview)

  • 송창엽;김웅;계명찬
    • 환경생물
    • /
    • 제35권4호
    • /
    • pp.581-594
    • /
    • 2017
  • 비스페놀 A는 플라스틱과 에폭시 레진에 사용되는 대표적인 내분비계 교란물질이다. BPA가 함유된 플라스틱은 물병, 식품용기, CD, DVD, 그리고 건설현장에서 사용되는 건축자재 등에 사용되고 있으며, BPA가 함유된 에폭시 레진은 상수도관 내의 코팅제, 식품용 캔 그리고 영수증용 감열지 등에 사용되고 있다. BPA의 에스트로젠 유사효과와 다른 유해 영향이 많이 보고되고 있기 때문에 이미 많은 나라에서 BPA가 규제되고 있으며, BPA의 대체재를 만들기 위해 노력 중에 있다. 비스페놀 S와 비스페놀 F가 BPA의 대체재로 사용되고 있으며, 최근에 BPS와 BPF가 함유된 제품들이 광범위하게 소비되고 있다. 하지만, BPA와 비슷한 화학구조 때문에 이 대체재들 또한 BPA처럼 내분비계의 교란을 일으키며 이 대체재들의 유해 영향도 이미 많은 연구들을 통해 보고되고 있는 실정이다. 본 소고에서 비스페놀류의 유해 영향과 규제 현황을 기술하고자 한다.

Experimental and numerical investigation of closure time during artificial ground freezing with vertical flow

  • Jin, Hyunwoo;Go, Gyu-Hyun;Ryu, Byung Hyun;Lee, Jangguen
    • Geomechanics and Engineering
    • /
    • 제27권5호
    • /
    • pp.433-445
    • /
    • 2021
  • Artificial ground freezing (AGF) is a commonly used geotechnical support technique that can be applied in any soil type and has low environmental impact. Experimental and numerical investigations have been conducted to optimize AGF for application in diverse scenarios. Precise simulation of groundwater flow is crucial to improving the reliability these investigations' results. Previous experimental research has mostly considered horizontal seepage flow, which does not allow accurate calculation of the groundwater flow velocity due to spatial variation of the piezometric head. This study adopted vertical seepage flow-which can maintain a constant cross-sectional area-to eliminate the limitations of using horizontal seepage flow. The closure time is a measure of the time taken for an impermeable layer to begin to form, this being the time for a frozen soil-ice wall to start forming adjacent to the freeze pipes; this is of great importance to applied AGF. This study reports verification of the reliability of our experimental apparatus and measurement system using only water, because temperature data could be measured while freezing was observed visually. Subsequent experimental AFG tests with saturated sandy soil were also performed. From the experimental results, a method of estimating closure time is proposed using the inflection point in the thermal conductivity difference between pore water and pore ice. It is expected that this estimation method will be highly applicable in the field. A further parametric study assessed factors influencing the closure time using a two-dimensional coupled thermo-hydraulic numerical analysis model that can simulate the AGF of saturated sandy soil considering groundwater flow. It shows that the closure time is affected by factors such as hydraulic gradient, unfrozen permeability, particle thermal conductivity, and freezing temperature. Among these factors, changes in the unfrozen permeability and particle thermal conductivity have less effect on the formation of frozen soil-ice walls when the freezing temperature is sufficiently low.

디지털 트윈 기반 스마트 파이프 상태 감시를 위한 대시보드 개념모델 설계 (Design of dashboard conceptual model for digital twin based smart pipe health monitoring)

  • 홍필두;김남호
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국정보통신학회 2022년도 추계학술대회
    • /
    • pp.389-391
    • /
    • 2022
  • 지하에 매설된 상·하수의 노후화를 관리하기 위한 환경부와 국내 지자체의 노력이 이어지고 있다. 한국환경산업기술원의 상·하수 혁신 기술 개발사업 지원으로 노후화에 따른 사고예측 및 교환시기 관리, 신규 매설 배관에 스마트 기능을 적용하는 사업을 진행하고 있다. 이러한 연구의 하나로 본 논문에서는 전체 연구의 핵심 특징 중 하나인 디지털 트윈 기반 스마트 파이프 상태 모니터링을 위한 대시보드 개념 모델의 설계를 제안하였다. 원격 제어와 모니터링이 주요 기능 중 하나이기 때문에 분산 송수신 에이전트를 배치해 모니터링 상황을 실시간으로 시각화하고 직관적인 UI를 배치해 사용자 친화력을 높혔다. 이 제안된 특수 디지털 트윈 기반 스마트 파이프 상태 모니터링의 설계를 검증하기 위해 개념 모델 수준을 구성하고 에이전트 효과를 측정하여 우수성을 검증하였다.

  • PDF

외부 유체와 연성된 도파관의 진동 및 소음 해석 기법 (A Numerical Method for Analysis of the Sound and Vibration of Waveguides Coupled with External Fluid)

  • 유정수
    • 한국음향학회지
    • /
    • 제29권7호
    • /
    • pp.448-457
    • /
    • 2010
  • 단면의 형상이 길이방향으로 일정한 무한길이 도파관 구조물 (waveguide structures)에 대한 진동 및 파동전파 특성은 도파관유한요소법 (waveguide finite element method, WFEM)을 이용해 효과적으로 해석할 수 있다. 도파관유한요소법은 2차원 단면만을 FE 모델링하여 해석하므로 모델의 크기가 작고 연산시간이 짧다는 장점이 있다. 도파관 구조물이 외부 유체와 연성된 경우, 원통형 실린더 또는 파이프와 같이 단면의 형상이 단순한 경우에는 이론적 해석을 수행할 수 있다. 반면 복잡한 형상의 단면을 가진 도파관구조물이 유체와 연성된 경우에는 수치해석 방법이 요구된다. 외부 유체와 연성된 도파관 구조물은 외부 유체와 도파관유한요소 (WFE)를 연성시켜 해석하는 수치해석 방법을 고려할 수 있다. 본 논문에서는 외부 유체 모델링에 경계요소 (Boundary Element)를 도입하고 이를 도파관유한요소와 연성시킨 WFE/BE 방법을 소개한다. 이 방법의 적용 예로써 단순형상의 파이프에 대해 외부 유체의 유/무에 따른 분산선도와 가진점 모빌리티 (point mobility)를 구하고 이를 이론해석 결과와 비교하였다. 또한 WFE/BE 방법을 이용해 파이프에서 외부 유체로 방사되는 음향파워를 구하고 접수 유/무에 따른 영향을 살펴보았다.

온수배관을 이용한 시설딸기 부분난방기술 개발 (Spot Heating Technology Development for Strawberry Cultivated in a Greenhouse by Using Hot Water Pipe)

  • 문종필;강금춘;권진경;백이;이태석;오성식;남명현
    • 한국농공학회논문집
    • /
    • 제58권5호
    • /
    • pp.71-79
    • /
    • 2016
  • The effects of spot heating for growing the strawberry cultivated in a plastic greenhouse during the winter that were estimated in Nonsan strawberry experiment station located in Chungnam. The temperature of water for heating was controlled by a electric hot water boiler and kept at the range of $22{\sim}24^{\circ}C$. Heating pipes were set up in root zone for root zone heating and very close to crown for crown heating. Spot heating effects were estimated by applying spot heating system in three test factors of heating root zone, crown only and crown plus root zone. The material for crown heating pipe was white low density polyethylene and the nominal diameter of that pipe was 16 mm. The material for root zone heating pipe was flexible stainless steel and the nominal diameter of that pipe was 15A. The flow rate of heating water circulation was 480 L/h and water circulation lasted for all day long. Temperatures, harvest yield by test beds were surveyed from Nov. 10, 2013 to Apr. 29, 2014. The temperature of crown spot for crown heating bed was at the range of $13.0{\sim}17.0^{\circ}C$ during the night and that of crown spot in control bed was at the range of $8.0{\sim}14.0^{\circ}C$. Also, the temperature of root zone for root zone heating bed was at the range of $18{\sim}21.0^{\circ}C$ and that of root zone in control bed was at the range of $13.0{\sim}15.0^{\circ}C$. The cumulative yield growth rate in earlier harvest period (from Dec. 20 to Mar. 15) of crown heating bed was 43% compared with that of control bed and the cumulative yield of crown plus root zone heating bed was 39 % and that of root zone heating bed was 39 %.