• Title/Summary/Keyword: Water mass analysis

검색결과 1,187건 처리시간 0.033초

Experimental study on seepage characteristics of large size rock specimens under three-dimensional stress

  • Sun, Wenbin;Xue, Yanchao;Yin, Liming;Zhang, Junming
    • Geomechanics and Engineering
    • /
    • 제18권6호
    • /
    • pp.567-574
    • /
    • 2019
  • In order to study the effect of stress and water pressure on the permeability of fractured rock mass under three-dimensional stress conditions, a single fracture triaxial stress-seepage coupling model was established; By using the stress-seepage coupling true triaxial test system, large-scale rock specimens were taken as the research object to carry out the coupling test of stress and seepage, the fitting formula of permeability coefficient was obtained. The influence of three-dimensional stress and water pressure on the permeability coefficient of fractured rock mass was discussed. The results show that the three-dimensional stress and water pressure have a significant effect on the fracture permeability coefficient, showing a negative exponential relationship. Under certain water pressure conditions, the permeability coefficient decreases with the increase of the three-dimensional stress, and the normal principal stress plays a dominant role in the permeability. Under certain stress conditions, the permeability coefficient increases when the water pressure increases. Further analysis shows that when the gob floor rock mass is changed from high stress to unloading state, the seepage characteristics of the cracked channels will be evidently strengthened.

낙동강 수계에서 제사방적제조 업체에 대한 공정별 원단위산정 및 분석 (Unit Mass Estimation and Analysis from Textile Spinning/Weaving Manufacturing Facility Nearby Nakdong River Basin)

  • 이홍신;손건태;구정은;콘분락사;이홍태;이승환
    • 상하수도학회지
    • /
    • 제22권5호
    • /
    • pp.541-550
    • /
    • 2008
  • In this investigative study, the unit mass discharge for the major water quality parameters such as flowrate, SS, BOD, CODmn, CODcr, TN, TP from textile spinning/weaving industry nearby Nakdong river basin was estimated. To represent the respective industries, three companies from hundreds of textile spinning/weaving industries located in Nakdong river basin was carefully selected based on its manufacturing goods, flowrate and location for the estimation of unit mass discharge based on unit operation and process. There was a drastic decrease of unit mass discharge estimation between influents and effluents of water quality parameters, which represents the removal capacity of wastewater treatment plant. With the advent of new regulation on the imposed payment proportional to the total amount of pollutants discharge into the water body, the concept of cleaner production technology should be employed in the unit operation/process in wastewater treatment plant as well as textile manufacturing procedure to minimize the levy on the pollutants discharge. Unit mass discharge estimations of unit process (estimated in this study) in major water quality parameters (SS, BOD, COD, TN and TP) based on land were similar to those of composite process (estimated by National Institute of Environmental Research). But the unit mass discharge estimations of unit process in BOD and CODmn based on total sale were much higher than those of composite one while in SS, TN and TP similar to each other. For the detailed estimation of the imposed payment, unit mass estimation based on unit process should be further emphasized.

Simultaneous Surveys of 22 GHz Water and 44 / 95 GHz Class I Methanol Masers toward High-Mass Protostellar Objects

  • Kim, Chang-Hee;Kim, Kee-Tae;Park, Young-Sun
    • 천문학회보
    • /
    • 제39권2호
    • /
    • pp.80.1-80.1
    • /
    • 2014
  • We made simultaneous surveys of 22 GHz water and 44 / 95 GHz methanol masers toward 299 high-mass protostellar objects using the Korea VLBI Network (KVN) 21-m telescope. The sources were selected from the catalog of Red MSX Source (RMS) survey. Initial selection of the sample present high-mass protostellar objects in an evolutionary phase prior to ultra-compact HII regions, which have bolometric luminosities > $10^3L_{\odot}$ but are not associated with any radio continuum emission. After the follow-up work of ongoing RMS survey, final samples contains 56 sources classified as HII regions. We performed a simultaneous survey of 22 GHz water and 44 GHz methanol masers in 2011 and then conducted a simultaneous survey of 22 GHz water and 44 / 95 GHz methanol masers in 2012. The primary scientific goals of these surveys are to investigate the relationship among the three masers and to explore the relationship between each maser and the central star or the parental dense core. The detection rates of two epochs are 42% and 38% for water, 25% and 26% for 44 GHz methanol, and 23% (2012 only) for 95 GHz methanol masers. We performed a statistical analysis on subsample associated with a large data found in literature. In this poster, we will the preliminary data analysis results and discuss the implications.

  • PDF

LC-Tandem Mass Spectrometry를 활용한 농업용수 중 Perfluorochemicals 분석시료 전처리법 (Sample Preparation Method for Perfluorochemicals with LC-Tandem Mass Spectrometry in Agricultural Water)

  • 김진효;진초롱;최근형;박병준
    • 농약과학회지
    • /
    • 제19권1호
    • /
    • pp.1-4
    • /
    • 2015
  • 잔류성 유기오염물질인 과불화합물 중 perfluorooctanesufonic acid (PFOS)와 perfluorooctanoic acid (PFOA)의 잔류분석은 환경부 "잔류성 유기오염물질 공정시험기준"에 따라 hydrophilic-lipophilic balance (HLB) solid phase extraction (SPE) 전처리 후 LC-$MS^n$를 이용해 정량 분석하고 있다. 본 연구에서는 환경부 설정 공정시험법에 따라 농업용수 전처리 후, 시험법에서 제거하지 못한 미지의 불순물을 Envi-Carb$^{TM}$을 통해 회수율에 영향을 주지 않고 손쉽게 제거하였다. 또한, 과불화합물 분석에 사용되는 LC-$MS^n$ 중 quadrupole-time-of-flight mass spectrometry (qTOFMS)에서 측정된 PFCs의 정량한계를 평가한 결과, 시험에 사용된 장비간 정량한계 편차가 크게 관찰되었으나, 시험대상 장비 모두 농업용수 중 ng/L 수준으로 잔류하는 과불화합물의 정밀 잔류분석에 사용가능 한 것으로 확인되었다.

Integral Analysis of the Effects of Non-absorbable gases on the Heat Mass Transfer of Laminar Falling Film

  • Kim, Byong-Joo
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제6권
    • /
    • pp.56-66
    • /
    • 1998
  • The absorption process of water vapor in a liquid film is an important process in LiBr-Water absorption system. The composition of the gas phase, in which a non-absorbable gas is combined with the absorbate, influences the transport characteristics. In the present work, the absorption processes of water vapor into aqueous solutions of lithium bromide in the presence of non-absorbable gas are investigated. The continuity, momentum, energy and diffusion equations for the solution film and gas are formulated in integral forms and solved numerically. It is found that the mass transfer resistance in gas phase increases with the concentration of non-absorbable gas. However the primary resistance to mass transfer is in the liquid phase. As the concentration of non-absorbable gas in the absorbate increases, the interfacial temperature and concentration of absorbate in solution decrease, which results in the reduction of absorption rate. The reduction of mass transfer rate is found to be significant for the addition of a small amount of non-absorbable gas to the pure vapor, especially at the outlet of tube where the non-absorbable gas accumulates. At higher non-absorbable gas concentration, the decrease of absorption rate seems to be linear to the concentration of non-absorbable gas.

  • PDF

신뢰성 기준을 적용한 용수공급능력의 해석 - 낙동강유역을 중심으로 - (The Analysis of Water Supply Capacity using Reliability Criteria - for the Nakdong River Basin -)

  • 차상화;지홍기;이순탁
    • 한국환경과학회지
    • /
    • 제11권12호
    • /
    • pp.1227-1233
    • /
    • 2002
  • In general, the evaluation of water supply capacity is important factor to establish various establishment of water resource supply plan include water resource security and determination of dam's mass. But former researchs about estimation of water supply capacity were lack in continunity of evaluation basis, and didn't excute analysis on reliability criteria also. In this study, Nakdong river was selected for study basin, and then water supply capacity was analyzed by HEC-5 model using identical reliability criteria.

A Study on the Effects of System Pressure on Heat and Mass Transfer Rates of an Air Cooler

  • Jung, Hyung-Ho
    • Journal of Mechanical Science and Technology
    • /
    • 제16권5호
    • /
    • pp.696-702
    • /
    • 2002
  • In the present paper, the effects of inlet pressure on the heat and mass transfer rates of an air cooler are numerically predicted by a local analysis method. The pressures of the moist air vary from 2 to 4 bars. The psychrometric properties such as dew point temperature, relative humidity and humidity ratio are employed to treat the condensing water vapor in the moist air when the surface temperatures are dropped below the dew point. The effects of the inlet pressures on the heat transfer rate, the dew point temperature, the rate of condensed water, the outlet temperature of air and cooling water are calculated. The condensation process of water vapor is discussed in detail. The results of present calculations are compared with the test data and shows good agreements.

An Experimental Study on the Mass and Energy Release for a Hot Leg Break LBLOCA During Post Blowdown

  • S.J. Hong;Kim, J.H.;Park, G.C.
    • Nuclear Engineering and Technology
    • /
    • 제32권2호
    • /
    • pp.108-127
    • /
    • 2000
  • Hot leg break LBLOCA(Large Break LOCA) had a potential to be a containment maximum pressure accident in YGN3&4, which was induced from excessive conservatism in the CE analysis methodology of mass and energy release. This study conducted mass and energy release experiment for the hot leg break LBLOCA during post blowdown with an integral test facility, SNUF(Seoul National University Facility). This facility simulated YGN 3&4 with volume ratio of 1/1140 based on Ishii's three level scaling. Experiment showed that SI(Safety Injection) water refilled cold leg first and core later. SI water was vaporized in the core, which resulted in the repressurization of reactor. This increase of pressure drove the water in cold leg to flow up half height of U tubes. However, since the water was drained back soon, the release through the SG side broken section by evaporation was negligibly small. This study also provided experimental assessment of RELAP5 results by KAERI for the release through the SG side broken section.

  • PDF

다변량분석을 이용한 터널에서의 간편 RMR에 관한 연구 (A Study of Simple Rock Mass Rating for Tunnel Using Multivariate Analysis)

  • 위용곤;노상림;윤지선
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2000년도 가을 학술발표회 논문집
    • /
    • pp.493-500
    • /
    • 2000
  • Rock Mass Rating has been widely applied to the underground tunnel excavation and many other practical problems in rock engineering. However, Rock Mass Rating is hard to make out because it is difficult to estimate each valuation items through all kind of field situations and items of RMR have interdependence. So the experts of tunnel assessment have problems with rating rock mass. In this study, using multivariate analysis based on domestic data(1011EA) of water conveyance tunnel, we presented rock mass rating system which is objective and easy to use. The constituents of RMR are decided to RQD, condition of discontinuities, groundwater conditions, orientation of discontinuities, intact rock strength, spacing of discontinuities in important order. In each step, we proposed the best multiple regression model for RMR system. And using data which have been collected at other site, we examined that presented multiple regression model was useful.

  • PDF

저온 열원 활용을 위한 암모니아-물 재생 랭킨 사이클의 성능 해석 (Performance Analysis of Ammonia-Water Regenerative Rankine Cycles for Use of Low-Temperature Energy Source)

  • 김경훈;한철호
    • 한국태양에너지학회 논문집
    • /
    • 제31권1호
    • /
    • pp.15-22
    • /
    • 2011
  • It is a great interest to convert more energy in the heat source into the power and to improve the efficiency of power generating processes. Since the efficiency of power generating processes becomes poorer as the temperature of the source decreases, to use an ammonia-water mixture instead of water as working fluid is a possible way to improve the efficiency of the system. In this work performance of ammonia-water regenerative Rankine cycle is investigated for the purpose of extracting maximum power from low-temperature waste heat in the form of sensible energy. Special attention is paid to the effect of system parameters such as mass fraction of ammonia and turbine inlet pressure on the characteristics of system. Results show that the power output increases with the mass fraction of ammonia in the mixture, however workable range of the mass fraction becomes narrower as turbine inlet pressure increases and is able to reach 16.5kW per unit mass flow rate of source air at $180^{\circ}C$.