• 제목/요약/키워드: Water mass analysis

검색결과 1,187건 처리시간 0.035초

수치해석에 의한 심수 탱크구조물의 진동에 관한 연구 (Numerical Analysis of Vibration Characteristics in Deep Water Tank)

  • 배성용
    • 한국소음진동공학회논문집
    • /
    • 제13권10호
    • /
    • pp.791-797
    • /
    • 2003
  • A liquid storage rectangular tank structures are used In many fields of civil, mechanical and marine engineering. Especially, Ship structures have many tanks In contact with Inner or outer fluid, like ballast, fuel and cargo tanks. Fatigue damages are sometimes observed in these tanks which seem to be caused by resonance with exciting force of engine and propeller. Vibration characteristics of these thin walled tanks in contact with fluid near engine or propeller are strongly affected by added mass of containing fluid. Therefore it is essentially important to estimate the added mass effect to predict vibration of the tank structures. In the previous report, we have developed numerical tool of vibration analysis of 3-dimensional tank structure using finite elements for plates and boundary elements for fluid region. In the present report, using the numerical analysis, vibrations characteristics In deep water tank are investigated and discussed.

수치해석에 의한 심수 탱크구조물의 진동에 관한 연구 (Numerical Analysis of Vibration Characteristics in Deep Water Tank)

  • 배성용;홍봉기;배동명
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2003년도 춘계학술대회논문집
    • /
    • pp.1079-1084
    • /
    • 2003
  • A liquid storage rectangular tank structures are used in many fields of civil, mechanical and marine engineering. Especially, Ship structures have many tanks in contact with inner or outer fluid, like ballast, fuel and cargo tanks. Fatigue damages are sometimes observed in these tanks which seem to be caused by resonance with exciting force of engine and propeller. Vibration characteristics of these thin walled tanks ill contact with fluid near engine or propeller are strongly affected by added mass of containing fluid. Therefore it is essentially important to estimate the added mass effect to predict vibration of the tank structures. In the previous report, we have developed numerical tool of vibration analysis of 3-dimensional tank structure using finite elements for plates and boundary elements for fluid region. In the present report, using the numerical analysis, vibrations characteristics in deep water tank are investigated and discussed.

  • PDF

정상 성인의 신체조성과 폐 기능의 연관성 (Correlation between Body Composition and Lung Function in Healthy Adults)

  • 김현승;조성현
    • 대한통합의학회지
    • /
    • 제8권2호
    • /
    • pp.53-61
    • /
    • 2020
  • Purpose : We investigated the correlation between body composition and lung function in healthy adults. Methods : This study included 204 healthy adults in whom all measurements were obtained once, and all data were analyzed using the SPSS software for Windows, version 22.0. Pearson's correlation analysis was performed to determine the correlation between body composition (represented by the total body water, protein mass, soft lean mass, mineral mass, basal metabolic rate, fat-free mass, skeletal muscle mass, and body fat percentage) and lung function (represented by the forced vital capacity [FVC], forced expiratory volume in 1 second [FEV1], the FEV1/FVC ratio, maximum voluntary ventilation [MVV], maximum expiratory pressure [MEP], and the maximum inspiratory pressure [MIP]). All measurements were obtained by two investigators to improve reliability. A significance level of α=.05 was used to verify statistical significance. Results : Among the lung function measurements obtained in both men and women, the FVC, FEV1, MVV, and MIP were positively correlated with the total body water, protein mass, soft lean mass, mineral mass, basal metabolic rate, fat-free mass, and skeletal muscle mass in men (p<.05). The FEV1/FVC ratio was negatively correlated with the total body water, soft lean mass, mineral mass, basal metabolic rate, fat-free mass and the body fat percentage (p<.05). Notably, the FVC, FEV1, and MVV were positively correlated with the total body water, protein mass, soft lean mass, mineral mass, basal metabolic rate, fat-free mass, and skeletal muscle mass in women (p<.05). Conclusion : This study showed a significant correlation between body composition and lung function in healthy adults. In combination with future studies on lung function, our results can provide objective evidence regarding the importance of prevention of lung disease, and our data can be utilized in rehabilitation programs for patients with respiratory diseases.

생태모델을 이용한 해상형 해양심층수 사업해역의 환경 특성 평가 (Estimation of Environmental Characteristics for Deep Ocean Water Development Site Using Ecological Model)

  • 김동명
    • 한국환경과학회지
    • /
    • 제20권7호
    • /
    • pp.919-927
    • /
    • 2011
  • A ecosystem model was applied for understanding of circulation process of state variables in marine ecosystem. A mass balance was conducted by calculating the physical process. The sensitivity analysis was conducted to know which coefficient is the most effective factor to the state variables in the model. The results of the mass balance indicate that the primary production was 58.6 ton C/day in the case of mass flux. DIN and DIP in nutrient ingestion of phytoplankton were each 7.9 ton N/day, 1.1 ton P/day. POC and DOC in mineralization of organic matter were each 10.8 ton C/day, 40.6 ton C/day. The results of sensitivity analysis showed that the maximum growth rate of phytoplankton was the most important factor for overall state variables. In the case of nutrients, Half saturation constant of DIN, and mineralization rate of DOM for COD were important factor.

고효율 오존장치를 이용한 NOM 제거 및 Bromate 생성 특성 (Investigation on Bromate Formation and Removal of NOM during Ozonation in Super Ozone Mass Transfer Reactor)

  • 송기주;최일환;백경희;이상태
    • 한국물환경학회지
    • /
    • 제22권6호
    • /
    • pp.1137-1143
    • /
    • 2006
  • In this study we investigated the removal characteristics of NOM and bromate formation characteristics in SOMT reactor. The system was recently developed as a novel ozone reactor and installed in SJ pilot plant. DOC values were decreased within 3% after treatment of 0.5~2.0 mg/L ozone dosage in SOMT reactor while the $UV_{254}$ value was 69% decreased at 2.0 mg/L ozone dosage. The composition of NOM was analysed by LC-OCD (Organic Cabon Detector) after ozone treatment in SOMT reactor to elucidate the variation of NOM character. Polysaccharide (more than 20,000 g/mol) fraction of NOM was decomposed while building blocks (350~500 g/mol) and neutral (less than 350 g/mol) fraction increased. Spiked bromide reacted with 0.5~2.0 mg/L ozone dosage in the SOMT reactor. The bromate formation was proportional to the ozone dosage ($R^2=0.978$) but not proportional to reaction time. The maximum concentration of formated bromate was not exceeded to 10% of spiked bromide concentration.

진해만 빈산소수괴의 경년변동 특성 (Annual Variation in Oxygen-deficient Water Mass in Jinhae Bay, Korea)

  • 이인철;오유진;김헌태
    • 한국수산과학회지
    • /
    • 제41권2호
    • /
    • pp.134-139
    • /
    • 2008
  • To improve the oxygen-deficient water mass (ODW), the spatial and temporal variation in the water quality and characteristic of ODW occurrence were analyzed using yearly water quality data from 1989 to 2006 in Jinhae Bay, Korea. In addition, we estimated $ODW_{area},\;ODW_{vol.}$ and $ODW_R$ for Jinhae Bay. The overall water quality improved during the 2000s, based the annual variation in dissolved oxygen, chemical oxygen demand, etc. A cluster analysis classified Jinhae Bay into the southwestern, central, northern, and eastern regions. ODW occurred throughout the southwestern region in 1993 and 2002-2004, and the estimated $ODW_{vol.}$ was about $1.92km^3$. ODW did not occur in the eastern region because circulating seawater was exchanged in that part of Jinhae Bay. As ODW was generated every year in the southwestern region, this is the most polluted area in Jinhae Bay. The ODWR decreased in the northern region, showing that the water quality there has improved since a wastewater treatment plant began operating in 1994.

7구역 진단기와 임상지표와의 상관성 연구 (A Study on the Correlation about 7-Zone-Diagnostic System and Clinical Parameters)

  • 조웅희;박원형;차윤엽
    • 한방재활의학과학회지
    • /
    • 제20권1호
    • /
    • pp.167-182
    • /
    • 2010
  • Objectives : The purpose of this study is to find correlation about 7-Zone-Diagnostic System and Clinical Parameters using Oriental Health Examination. Methods : Subjects of our study were 325 cases who took Oriental Health Examination. We collected the data of body composition analysis, 7-Zone-Diagnostic System, blood analysis and devided by 7-Zone-Diagnostic system to acceleration, normalcy and depression. Results and Conclusions : The values of muscle mass, body fat mass, abdomen obesity rate, right arm water index, left arm water index, trunk water index, right leg water index, left leg water index, BMI, BMR, GOT, GPT, ${\gamma}$-GTP, BUN, TC, triglyceride and hemoglobin were continuous with 7-Zone-Diagnostic system.

도수관로 실시간 관파손감지를 위한 물수지 분석 방법 적용 및 성능평가 (Application and performance evaluation of mass balance method for real-time pipe burst detection in supply pipeline)

  • 신은허;정기문;김경필;최태호;채선하;조용우
    • 상하수도학회지
    • /
    • 제37권6호
    • /
    • pp.347-361
    • /
    • 2023
  • Water utilities are making various efforts to reduce water losses from water networks, and an essential part of them is to recognize the moment when a pipe burst occurs during operation quickly. Several physics-based methods and data-driven analysis are applied using real-time flow and pressure data measured through a SCADA system or smart meters, and methodologies based on machining learning are currently widely studied. Water utilities should apply various approaches together to increase pipe burst detection. The most intuitive and explainable water balance method and its procedure were presented in this study, and the applicability and detection performance were evaluated by applying this approach to water supply pipelines. Based on these results, water utilities can establish a mass balance-based pipe burst detection system, give a guideline for installing new flow meters, and set the detection parameters with expected performance. The performance of the water balance analysis method is affected by the water network operation conditions, the characteristics of the installed flow meter, and event data, so there is a limit to the general use of the results in all sites. Therefore, water utilities should accumulate experience by applying the water balance method in more fields.

암모니아/물 흡수식 냉동기의 판형 재생기의 수치해석 (Numerical Analysis of a Plate Type Generator for Ammonia/Water Absorption Refrigerators)

  • 지제환;정은수;정시영
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 춘계학술대회논문집D
    • /
    • pp.304-310
    • /
    • 2001
  • A numerical model which simulates the heat and mass transfer processes within a counter-current plate type generator for ammonia/water absorption refrigerators was developed. Ammonia/water solution flows downward under gravity and ammonia/water vapor generated by flow boiling flows upward. The flow pattern within the generator was assumed to be a bubbly flow, and the liquid and vapor phase were assumed to be saturated. It was shown that the boiling of ammonia occurred mainly in the upper part of the generator. The effects of the generator length, the wall temperature and the mass flow rate of ammonia/water solution into the generator on the generation of ammonia/water vapor were investigated.

  • PDF

New 3D failure analysis of water-filled karst cave beneath deep tunnel

  • Zhang, R.;Yang, X.L.
    • Geomechanics and Engineering
    • /
    • 제18권1호
    • /
    • pp.1-9
    • /
    • 2019
  • In this study, both 2D and 3D failure shapes of rock mass above the water-filled cavity are put forward when the surrounding rock mass cannot bear the pressure caused by the water-filled cavity. Based on the analytical expressions derived by kinematic approach, the profiles of active and passive failure patterns are plotted. The sensitivity analysis is conducted to explore the influences of different rock parameters on the failure profiles. During the excavation of the deep tunnels above the karst cavity, the water table always changes because of progressive failure of cavity roof. Therefore, it is meaningful to discuss the effects of varying water level on the failure patterns of horizontal rock layers. The changing laws of the scope of the failure pattern obtained in this work show good consistency with the fact, which could be used to provide a guide in engineering.