• 제목/요약/키워드: Water mass

검색결과 3,696건 처리시간 0.028초

350 kW(300,000 kcal/h)급 우드 펠렛 보일러 운전 특성 및 성능 평가 (Performance Test and Flue Gas Characteristics of a 350 kW Wood Pellet Boiler)

  • 김종진;강새별
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.167-171
    • /
    • 2009
  • We conducted performance test of a 350 kW class wood pellet boiler installed at a dormitory whose total area is $1,354\;m^2$. The maximum heating capacity of the boiler is 350 kW(300,000 kcal/kg). The wood pellet boiler consists of 3 parts; boiler, hot water storage tank and wood pellet storage tank. In testing the boiler, we shut off hot water utility supply and open up floor heating water system in order to measure exact value of the heating output of the wood pellet boiler. To determine the efficiency and heating output of the wood pellet boiler, we measured mass flow rate of wood pellet, the lower heating value(LHV) of the wood pellet, mass flow rate and temperature of water for floor heating and so on. We measured the mass flow rate of fuel, wood pellet with respect to rotational speed of auger, wood pellet feeding screw. We also measured the flue gas concentration of the wood pellet boiler by using a gas analyser. The result shows that the efficiency of the wood pellet boiler is 80.6% based on lower heating value at 124 kW of heating output. At this condition, O2 concentration of the flue gas is 6.0%, CO and NOx concentrations are 85 and 102 ppm.

  • PDF

일본 살남해역의 GEK 측정결과에 대한 연구 (A Study on the Results of GEK Measurement in Satsunan Sea of Japan)

  • 임기봉;등본실
    • 한국해양학회지
    • /
    • 제6권2호
    • /
    • pp.99-103
    • /
    • 1971
  • GEK(Geomagnetic Electrokinetograph)가 개발되고 그에 대한 취급의 간편, 측정의 용이, 정도의 우수성으로 GEK를 이용한 많은 관측이 수행되고 또 그들 자료를 바탕으로 많은 연구에 임하고 있어, 지금은 해양관측에 있어 필수의 기계로서 이것으로 해류조사를 행한다고 하는 것은 널리 알려진 바이다. 그러나 여기에서는 " 사쓰난"(살남) 해역 (일본 구주 남서방해역)과 같이 조석류와 복잡한 해저지형 및 대소다양한 도서의 분포 등으로 영향 받는 해역에서의 GEK 측정은 타해역 (일본 본주 남방의 흑조류역 등)에서 행하여지는 것 같이 쉽지 않다고 볼 수 있다. 여기에 일본 사쓰난해역에서 조사된 GEK의 측득치에 대하여 검토하였다.대하여 검토하였다.

  • PDF

채널이 수막으로 완전히 덮여 있는 증발식 냉각기에서의 열 및 물질전달 해석 (Analysis of Heat and Mass Transfer in an Evaporative Cooler with Fully Wetted Channel)

  • 송찬호;이대영;노승탁
    • 대한기계학회논문집B
    • /
    • 제25권12호
    • /
    • pp.1766-1775
    • /
    • 2001
  • A theoretical analysis on the heat and mass transfer in an evaporative cooler is presented in this work. The evaporative cooler is modeled as a channel filled with porous media the interstitial surface of which is covered by thin water film. Assuming that the Lewis number is unity and the water vapor saturation curve is linear, exact solutions to the energy and vapor concentration equations are obtained. Based on the exact solutions, the characteristics of the heat and mass transfer in the evaporative cooler are investigated. The comparison of the cooling performance between the evaporative cooler and the usual sensible heat exchanger is also carried out. Obviously, the evaporative heat exchanger shows better cooling performance than the sensible heat exchanger. This is due to the latent heat of water vaporization, which results in apparent increases both in the interstitial heat transfer coefficient and the specific heat of the air stream in the evaporative cooler.

중공사막 접촉기를 이용한 암모니아 물질전달 모델링 (Modeling of Ammonia Mass Transfer Using a Hollow Fiber Membrane Contactor)

  • 오대양;정주영;최원호;박주양
    • 상하수도학회지
    • /
    • 제25권4호
    • /
    • pp.503-510
    • /
    • 2011
  • Ammonia in water which is toxic to human, its concentration is regulated below 0.5 mg/L in drinking water. Current study aimed to develop appropriate models for ammonia stripping using hollow fiber membrane contactor. Two different models were developed during the study. Model 1 was assumed only free ammonia ($NH_3$) transfer in stripping process, whereas the Model 2 was assumed with total ammonia ($NH_3+{NH_4}^+$) transfer. Ammonium chloride ($NH_4CI$), sodium hydroxide(NaOH) were used to make ammonia solution, which was concentration of 25 mg as N/L at a pH of 10.5. The experimental conditions were such that, the liquid flow was in tube-side in upward direction and t he gas flow was on shell-side in downward direction a t room temperature. The experimental and modeling results showed that marginal difference were observed at low gas flux. However the difference between the both models and experimental value were increased when the gas flux was increased. The study concludes that the Model 1 with free ammonia is more appropriate when both models were compared and useful in ammonia stripping process at low gas flux.

냉각제들에 따른 불연속 발열체의 냉각성능 연구 (Study on the cooling performance of discrete heat sources using coolants)

  • 최민구;조금남
    • 설비공학논문집
    • /
    • 제11권2호
    • /
    • pp.224-235
    • /
    • 1999
  • The present study investigated the effects of the experimental parameters on the cooling characteristics of the multichip module cooled by the indirect liquid cooling method using water, PF-5060, and paraffin slurry. The experimental parameters were coolants including Paraffin slurry with mass fraction of 2.5~7.5%, heat flux of 10~40W/$\textrm{cm}^2$ for the simulated VLSI chips and Reynolds numbers of 3,000~20,000. The size of paraffin slurry was constant as 10~40${\mu}{\textrm}{m}$ before and after the experiment. The chip surface temperatures for paraffin slurry were lower than those for water and PF-5060. The local heat transfer coefficients for the paraffin slurry were larger than those for water and the local heat transfer coefficients reached a row-number-independent and thermally-fully-developed value approximately after the third row. The local Nusselt numbers for paraffin slurry with a mass fraction of 7.5% were larger by 20~38% than those for water. The paraffin slurry with a mass fraction of 5% shelved the best thermal and hydrodynamic characteristics when local heat transfer and pressure drop were considered simultaneously.

  • PDF

Transformation of dissolved organic matter in a constructed wetland: A molecular-level composition analysis using pyrolysis-gas chromatography mass spectrometry

  • Park, Jongkwan;Choi, Mijin;Cho, Jaeweon;Chon, Kyongmi
    • Environmental Engineering Research
    • /
    • 제23권4호
    • /
    • pp.390-396
    • /
    • 2018
  • This study investigated the transformation of dissolved organic matter (DOM) in a free-water surface flow constructed wetland. Pyrolysis gas chromatography-mass spectrometry (Py-GC/MS) coupled with preparative high-performance liquid chromatography (prep-HPLC) was used to analyze the compositions of biopolymers (polysaccharides, amino sugars, proteins, polyhydroxy aromatics, lipids and lignin) in DOM according to the molecular size at three sampling points of the water flow: inflow, midflow, and outflow. The prep-HPLC results verified the decomposition of DOM through the decrease in the number of peaks from three to one in the chromatograms of the sampling points. The Py-GC/MS results for the degradable peaks indicated that biopolymers relating to polysaccharides and proteins gradually biodegraded with the water flow. On the other hand, the recalcitrant organic fraction (the remaining peak) in the outflow showed a relatively high concentration of aromatic compounds. Therefore, the ecological processes in the constructed wetland caused DOM to become more aromatic and homogeneous. This indicated that the constructed wetland can be an effective buffer area for releasing biochemically stable DOM, which has less influence on biological water quality indicators, e.g., biochemical oxygen demand, into an aquatic ecosystem.

수동급기 직접 메탄올 연료전지의 동적 모델 (Dynamic Model of a Passive Air-Breathing Direct Methanol Fuel Cell)

  • 하승범;장익황;차석원
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2008년도 춘계학술대회 논문집
    • /
    • pp.33-36
    • /
    • 2008
  • The transient behavior of a passive air breathing direct methanol fuel cell (DMFC) operated on vapor-feeding mode is studied in this paper. It generally takes 30 minutes after starting for the cell response to come to its steady-state and the response is sometimes unstable. A mathematical dynamic one-dimensional model for simulating transient response of the DMFC is presented. In this model a DMFC is decomposed into its subsystems using lumped model and divided into five layers, namely the anodic diffusion layer, the anodic catalyst layer, the proton exchange membrane (PEM), the cathodic catalyst layer and the cathodic diffusion layer. All layers are considered to have finite thickness, and within every one of them a set of differential-algebraic governing equations are given to represent multi-components mass balance, such as methanol, water, oxygen and carbon dioxide, charge balance, the electrochemical reaction and mass transport phenomena. A one-dimensional, isothermal and mass transport model is developed that captures the coupling between water generation and transport, oxygen consumption and natural convection. The single cell is supplied by pure methanol vapor from a methanol reservoir at the anode, and the oxygen is supplied via natural air-breathing at the cathode. The water is not supplied from external source because the cell uses the water created at the cathode using water back diffusion through nafion membrane. As a result of simulation strong effects of water transport were found out. The model analysis provides several conclusions. The performance drop after peak point is caused by insufficiency of water at the anode. The excess water at the cathode makes performance recovery impossible. The undesired crossover of the reactant methanol through the PEM causes overpotential at the cathode and limits the feeding methanol concentration.

  • PDF

시료 중 잔류 항생제 분석 방법: III. 기기 분석 방법 (Determination of Veterinary Antibiotic Residues: III. Analytical Methods_A Review)

  • 김찬식;류홍덕;정유진;김용석;류덕희
    • 한국물환경학회지
    • /
    • 제32권6호
    • /
    • pp.649-669
    • /
    • 2016
  • This study explored the analytical conditions for 21 veterinary antibiotics which have been popularly sold in South Korea in 2014 but have not yet been targeted in EPA method 1694. Most of the selected antibiotics were separated by a reverse-phase C18 column with a combination of (buffered) water and organic polar solvent, which was commonly methanol and acetonitrile in the gradient elution mode. Volatile additives such as formic acid, ammonium acetate and ammonium formate were usually added to the mobile phases to minimize asymmetrical and tailing of antibiotics' peaks and to increase their ionization in mass spectrometry. The analytical methods of aminoglycoside antibiotics were distinct from those of the other antibiotics in terms of adoption of ion-pair chromatography (IPC) and hydrophilic interaction liquid chromatography (HILIC) capable of retaining and separating extremely polar compounds due to their hydrophilicity. Trifluoroacetic acid or heptafluorobutyric acid was frequently added to the mobile phase as an ion-pair reagent for the IPC. Tandem mass spectrometry was numerously applied to the detection of antibiotics using positive electrospray ionization (ESI) and the selected reaction monitoring (SRM) mode. All reviewed analytical methods had been/were validated by evaluating recovery, limits of detection and quantification, decision limit or detection capability of the methods.

Control of Soybean Sprout Rot Caused by Pythium deliense in Recirculated Production System

  • Yun, Sung-Chul
    • The Plant Pathology Journal
    • /
    • 제19권6호
    • /
    • pp.280-283
    • /
    • 2003
  • A soybean-sprout rot epidemic occurred in a mass production soybean sprout factory in 2000 and 2001 in Korea, which caused up to 20% production loss. Among the causal pathogenic bacteria and fungi, Pythium deliense was found to be the dominant pathogen of severe root and hypocotyls rot, particularly in recirculating water system. An average of 90% of the isolated fungi from the rotted sprout on potato dextrose agar were Pythium sp. The fungal density of Pythium in the sampled water was monitored in the recycled water system for 1 year using a selective medium (com meal agar with Pimaricin, 10 mg; Rifampicin, 10 mg; and Ampicillin, 100 mg per 1 liter). The drained water from the soybean-sprout cultivation always had a certain amount of fungus in it. The removal of Pythium from the recycling water system must be thorough, safe, and environment friendly. However, the pathogen in the water was easily found even after ozone and chlorine treatments, which were devised on the recycling system for the removal of microorganisms. 5-$\mu\textrm{m}$ pore size filter was applied and was able to successfully control the disease. As the sprout industry increasingly shifts into mass production, the demand for water will increase continuously. Recycling water for sprout production is eco-friendly. However, a process must be devised to be able to first decompose organic matters before Pythium zoospores are filtered.

부산신항 용원수로에서의 오염원별 수질영향 조사 (A Study on Water Quality Impact by Pollution Source in Yongwon Channel, Busan Newport)

  • 권재현;김영도;정재훈;정원무
    • 상하수도학회지
    • /
    • 제27권2호
    • /
    • pp.185-196
    • /
    • 2013
  • In Yongwon channel, its natural flow of seawater is blocked by the construction of Busan Newport including the container berth. The channel was transformed into a narrow and long one, where it is possible that ships are only allowed to pass through the north-side channel of Gyeonmado located at the point of river mouth to Songjeongcheon. In addition, Yongwon channel is approximately 100 m wide on average and 3,600 m long, which has the highest slenderness ratio (length/width=36). So it is considered that the changes in the terrain characteristics of Yongwon channel is likely to alter the circulation of sea water, thereby changing its water quality. In this study, the seasonal change and the spatial variation of the water quality in Yongwon channel was analyzed for the effect of land pollution using the measurement data. The mass balance calculation method is used to analyze the water pollution resulting from sediment pollutants. This result shows that the improvement of the water quality in Yongwon channel can be obtained from the sewer pipe modification and the environmental dredging.