• 제목/요약/키워드: Water mass

검색결과 3,696건 처리시간 0.029초

Photocrosslinking of Low Molar Mass Poly(ethylene glycol)s

  • Hong, Ki-Chul;Kim, Jinhwan;Bae, Jin-Young
    • Macromolecular Research
    • /
    • 제9권5호
    • /
    • pp.253-258
    • /
    • 2001
  • Crosslinked poly(ethylene glycol)s (PEGs) were prepared by ultraviolet irradiation of low molar mass, liquid PEGs in the presence of benzophenone (BP) as a photoinitiator. The networks obtained have been characterized by DSC, IR, and contact angle measurements, and their water absorption and equilibrium swelling have been examined. The percent of gel formed and degree of swelling of the networks in water were dependent on the amount of BP in the reaction mixture, irradiation time and molar mass of PEG. Gel fraction yield exceeded 84%, and equilibrium swelling in water varied from 49 to 244%.

  • PDF

직접접촉식 열교환기내에서 물과 배기가스의 직접접촉에 의한 열 및 물질전달 (Heat and Mass Transfer between Hot Waste Gas and Cold Water in a Direct Contact Heat Exchanger)

  • 이금배
    • 대한기계학회논문집
    • /
    • 제16권6호
    • /
    • pp.1171-1178
    • /
    • 1992
  • 본 연구에서는 직접접촉식 열교환기를 이용한 실험을 통하여 열교환기 설계에 가장 중요한 열교환기 단위 체적당 총괄 열전달 계수를 시스템의 작동조건에 따라 구 하여 실제 설계자료로 이용하는 데 그 목적이 있다.

수치해석에 의한 심수 탱크구조물의 진동에 관한 연구 (Numerical Analysis of Vibration Characteristics in Deep Water Tank)

  • 배성용;홍봉기;배동명
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2003년도 춘계학술대회논문집
    • /
    • pp.1079-1084
    • /
    • 2003
  • A liquid storage rectangular tank structures are used in many fields of civil, mechanical and marine engineering. Especially, Ship structures have many tanks in contact with inner or outer fluid, like ballast, fuel and cargo tanks. Fatigue damages are sometimes observed in these tanks which seem to be caused by resonance with exciting force of engine and propeller. Vibration characteristics of these thin walled tanks ill contact with fluid near engine or propeller are strongly affected by added mass of containing fluid. Therefore it is essentially important to estimate the added mass effect to predict vibration of the tank structures. In the previous report, we have developed numerical tool of vibration analysis of 3-dimensional tank structure using finite elements for plates and boundary elements for fluid region. In the present report, using the numerical analysis, vibrations characteristics in deep water tank are investigated and discussed.

  • PDF

암모니아-물 작동유체의 부분증발유동을 적용한 재생 랭킨사이클에 관한 연구 (Study on Regenerative Rankine Cycle with Partial-Boiling Flow Using Ammonia-Water Mixture as Working Fluid)

  • 김경훈
    • 설비공학논문집
    • /
    • 제23권3호
    • /
    • pp.223-230
    • /
    • 2011
  • The power cycle using ammonia-water mixture as a working fluid is a possible way to improve efficiency of the system of low-temperature source. In this work thermodynamic performance of the ammonia-water regenerative Rankine cycle with partial-boiling flow is analyzed for purpose of extracting maximum power from the source. Effects of the system parameters such as mass fraction of ammonia, turbine inlet pressure or ratio of partial-boiling flow on the system are parametrically investigated. Results show that the power output increases with the mass fraction of ammonia but has a maximum value with respect to the turbine inlet pressure, and is able to reach 22 kW per unit mass flow rate of source air at $180^{\circ}C$.

용접식 판형 열교환기의 성능에 관한 실험적 연구 (An Experimental Study on the Performance of a Brazed Plate Heat Exchanger)

  • 김종하;권오경;윤재호;이창식
    • 설비공학논문집
    • /
    • 제14권1호
    • /
    • pp.83-90
    • /
    • 2002
  • An experimental study on the performance evaluation of a brazed plate heat exchanger with 10USRT of normal cooling capacity has been carried out. In the present study, a brazed plate heat exchanger was tested at a chevron angle $25^{\circ}$with refrigerant R-22. Refrigerant mass flux was ranged from 23 to 58 kg/$m^2$s in condensation, and from 22 to 53 kg/$m^2$s in evaporation. The heat transfer coefficients and pressure drops are increased as the mass flux increases. The water side pressure drop is increased as the cooling water flow rate and chilled water flow rate increase, while mass flux has little effect. It is also shown that the system performance can be improved by enlarging condensation heat transfer area.

워터핀치(Water Pinch)기법을 적용한 백판지공장의 공정수 재이용 최적화 (Optimization of Water Reuse Network Using Water Pinch Method in Duplex Board Mill)

  • 류정용;박대식;김용환;송봉근;서영범
    • 펄프종이기술
    • /
    • 제37권4호통권112호
    • /
    • pp.44-51
    • /
    • 2005
  • Paper mills use and discharge lots of water. And so now the papermaking industry could be classified into major water consuming industry In order to analyze the process water network and to establish the mass, water balance of duplex board mill, computer aided simulation was made using water pinch method. Based on the pinch analysis results, reuse of process water, after regenerating by microfilter as much as $140\;m^3/hr$, could be suggested without significant accumulation of contaminants in process water. According to this suggestion about $3000\;m^3/day$ of recycled process water could be sub stituted by regenerated water and consequently $30\%$ of energy cost is expected to be reduced.

Why the Mediterranean Sea Is Becoming Saltier

  • Bryden, Harry-L.;Boscolo, Roberta
    • Journal of the korean society of oceanography
    • /
    • 제37권3호
    • /
    • pp.117-124
    • /
    • 2002
  • Anthropogenic changes have been made to the water budget for the Mediterranean Sea as a result of river diversion projects. The decrease in freshwater inflow to the Mediterranean represents an effective increase in the overall net evaporation over the basin. Hydraulic control models for the exchange between the Mediterranean and Atlantic through the Strait of Gibraltar predict that the salinity of the Mediterranean should increase if the net evaporation over the Mediterranean increases. Increases in the salinity of the deep waters in both the western and eastern Mediterranean basins have been observed. The causes of such higher deep water salinity are attributed to increases in intermediate water salinity which are ultimately mixed down into the deep sea during wintertime buoyancy loss events. The pattern of the Mediterranean salinity increase is instructive for understanding how the water mass properties in a basin change over time as a result of anthropogenic changes.

Chemical Speciation of Trace Metals in Natural Water by Ultrafiltration/Size Exclusion Chromatography/UV Absorption/ICP-MS

  • Haraguchi, Hiroki;Itoh, Akihide;Kimata, Chisen
    • 분석과학
    • /
    • 제8권4호
    • /
    • pp.405-410
    • /
    • 1995
  • A study on elemental speciation of trace metals in lake water (Lake Biwa in Japan) has been carried out by a size exclusion chromatography (SEC) / inductively coupled plasma mass spectrometry (ICP-MS) system. Before analysis, the water sample was preconcentrated with a ultrafiltration technique, where the large molecules with molecular weight larger than 10,000 were concentrated. Then the preconcentrated water samples (500-1000 fold) were analyzed by a SEC/ICP-MS system. Most trace metals were found at the UV absorption peaks corresponding to the molecular weights of ca. 300,000 and 10,000-50,000, where trace metals were on-line detected by ICP-MS. The results suggest that many of trace metals exist as the large organic molecules-metal complexes in natural water.

  • PDF

물-공기 직접접촉식 공기조화장치의 성능해석 (Performance Analysis of Water/Air Direct Contact Air Conditioning System)

  • 유성연;권화길;김광영
    • 설비공학논문집
    • /
    • 제16권2호
    • /
    • pp.175-183
    • /
    • 2004
  • Performance of the water/air direct contact air conditioning system, in which heat and mass are directly transferred between air and water droplet, is simulated using semi-empirical method. Direct contact system improves transport efficiency compared to conventional indirect contact system. In this study, correlations for h$_{c}$A / c$_{pm}$ which represent the capacity of direct contact system are derived as a function of air and water flowrate from the experimental data. Cooling and heating performance of the water/air direct contact air conditioning system are evaluated using these correlations.ons.

혼합모형을 이용한 생수소비 분포의 근사화에 대한 소고(小考) (A Note on Approximation of Bottled Water Consumption Distribution: A Mixture Model)

  • 유승훈
    • 자원ㆍ환경경제연구
    • /
    • 제11권2호
    • /
    • pp.321-333
    • /
    • 2002
  • Approximating bottled water consumption distribution is complicated by zero observations in the sample. To deal with the zero observations, a mixture model of bottled water consumption distributions is proposed and applied to allow a point mass at zero. The bottled water consumption distribution is specified as a mixture of two distributions, one with a point mass at zero and the other with full support on the positive half of the real line. The model is empirically verified for household bottled water consumption survey data. The mixture model can easily capture the common bimodality feature of the bottled water consumption distribution. In addition, when covariates were added to the model, it was found that the probability that a household has non-consumption significantly varies with some variables.

  • PDF