• 제목/요약/키워드: Water hold-up

검색결과 30건 처리시간 0.02초

핀-관 열교환기에서의 핀의 물 접촉각이 응축잔수량에 미치는 영향 (The Effect of Water Contact Angles of the Fin Surfaces of the Fin-and-Tube Heat Exchangers on the Water Hold-up)

  • 신종민;이남교;한성주;하삼철
    • 설비공학논문집
    • /
    • 제13권6호
    • /
    • pp.490-496
    • /
    • 2001
  • An experimental study on the behavior of the water hold-up by condensation of a fin-and-tube heat exchanger with regard to the surface characteristics, i.e., contact angle, was conducted. The static and dynamic contact angles were measured, and condensation experiments were conducted. Flow patterns on the fins with different surface characteristics were visualized. Results showed that the static contact angle is proportional to the dynamic contact angle within the range of this study. The water hold-up of the heat exchanger increases as the static or dynamic contact angle of its surfaces increases. Existence of transition of flow patterns was found as the static or dynamic angle increase. Due to the transition in the flow patterns, changes in the gradient of the water hold-up is occurred around the static angle of 8$0^{\circ}C$.

  • PDF

핀-관 열교환기에서 동적접촉각과 물맺힘량과의 상관관계에 관한 연구 (A Study of Correlation between DCA and WHS in Fin-and-Tube Heat Exchanger)

  • 황준현;고영환;신종민
    • 설비공학논문집
    • /
    • 제14권10호
    • /
    • pp.786-791
    • /
    • 2002
  • An experimental study on the behavior of the water hold-up by spraying of a fin-and-tube heat exchanger with regard to the surface characteristics, i.e., contact angles, was conducted. The dynamic contact angles (DCA) were measured, and water hold-up by spraying (WHS) was conducted in the experiment. It is found that heat exchanger surface characteristics, spray pressure, spray water temperature and heat exchanger surface temperature play an important role in WHS. In order to evaluate relationship between WHS and surface characteristics, test conditions are determined through a contour analysis. A correlation was proposed to predict WHS as a function of DCA. With its test efficiency and consuming time, the prediction method can be used to evaluate WHS performance.

폭기공정의 물질전달 계수와 기체 포집율 및 소요동력의 상관관계에 대한 비교연구 (Comparison Study on Empirical Correlation for Mass Transfer Coefficient with Gas Hold-up and Input Power of Aeration Process)

  • 박상규;양희천
    • 대한기계학회논문집B
    • /
    • 제41권6호
    • /
    • pp.415-421
    • /
    • 2017
  • 환경규제의 강화에 따라 수처리 비용이 증가하는 추세이므로 폭기공정의 에너지 이용효율을 제고할 수 있는 소요동력에 대한 보다 정량적인 연구가 필요하다. 본 논문은 폭기공정의 물질전달 특성을 규명하기 위해 물질전달 계수와 기체 포집율 및 소요동력에 대한 상관관계식을 제시하였다. 소요동력이 커지면 기체 포집율은 감소하고 레이놀드 수는 증가하며, 혼합유동 선단 도달거리와 확산도가 증대되므로 물질전달 계수는 증가하였다. 물질전달 계수와 기체 포집율 및 소요동력의 상관관계 규명을 위해 제시한 실험식은 최대 약 ${\pm}10%$의 오차 범위에서 실험결과와 일치하였다.

脈動과 粒子運動 (Pulsation and Particle Motion)

  • 강웅기;김영욱
    • 대한화학회지
    • /
    • 제7권1호
    • /
    • pp.47-50
    • /
    • 1963
  • The effect of the pulsation on the particle hold-up in a pulsed wetted column has been studied theoretically for the case of laminar region and experimentally for the cases of transient and turbulent regions. The experiment has been carried out by employing water as fluid medium and solid particles. The pulsation has been given by the reciprocating motion of a piston. The results of the investigation show that the pulsation would not give apparent effect on the particle hold-up but would increase the total travelling length of the particle.

  • PDF

표면특성이 다른 두 핀-관 열교환기의 착상 및 제상 성능 (The Frost and Defrost Performances of Fin-and-Tube Exchangers with Different Surface Characteristics)

  • 신종민;최봉준
    • 설비공학논문집
    • /
    • 제14권6호
    • /
    • pp.525-531
    • /
    • 2002
  • The effects of different surface hydrophilicity on frosting and defrosting characteristic were experimentally investigated. Mass of frost and water hold-up was measured. Results showed that no significant difference in the frost mass was found between the two different surfaces while the water hold-up of heat exchanger court be reduced by the enhancement of surface hydrophilicity. Also, the defrosting efficiency m hydrophilic surface was improved by 76%. It was expected that hydrophilic heat exchanger could provide the improvements in both thermal-hydraulic performances and system reliability during frost/defrost operating in refrigeration systems.

촛불 실험과 관련된 오개념 교정을 위한 지도방안 탐색 (Exploration of the teaching method for the prescription of the misconceptions on the Candle Experiment)

  • 전우수
    • 한국초등과학교육학회지:초등과학교육
    • /
    • 제18권2호
    • /
    • pp.145-151
    • /
    • 1999
  • There is an experiment in the elementary science textbook which a burning candle hold upright in a water tank and a beaker is converted over the burning candle, the candle flame goes out and the water rises into the beaker. Some reference books including teachers' guide for the elementary school teachers explain the reason why water rises that oxygen is "used up", so water rises the same volume of consumed oxygen into the beaker. But this explanation is only partially correct. In this study, discrepancies of the explanation that oxygen is "used up" are analyzed. Water rises by two major reasons. One is that water can rise to the level about l/3 of the volume of consumed oxygen. The other is that the beaker is converted over the burning candle which produces hot CO2 and water vapor, and the candle's flame heats the air around it to expand, after the candle flame goes out, the air in the beaker cools and water vapor changes to liquid water, so, air pressure in the beaker is reduced, and the water is pushed into the beaker by great air pressure outside. 1 demonstrate a inquiry teaching method of the candle experiment.

  • PDF

마곡지구 하수열에너지이용 타당성 검토 (Feasibility study on district heating Magok area by sewage water heat source)

  • 이영수
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.357-362
    • /
    • 2009
  • As a unutilized energy, treated sewage water locates widespread near urban areas. From the previous survey, the sewage water is reported to hold energy potential up to 36,000 Tcal/year, which was 2.1% of the total domestic energy consumption and 9.7% of the energy usage in the household and business sector in 2006. Temperature of the sewage water differs locally, but its range is observed in a range of $20{\sim}25^{\circ}C$ in summer and $8{\sim}13^{\circ}C$ in winter. Since the temperature range of the sewage water has a better seasonal distribution about $5{\sim}10^{\circ}C$ compared to ambient air, it is a promising heat sink for summer or heat source for winter. The sewage water is also a high quality heat source from its abundant quantity and uniform temperature. Considering the ambient temperature of Korea is very low in winter, a heat pump system using the sewage water can be an alternative to prevent problems of capacity deficiency and frost formation.

  • PDF

DAF 공정에서 발생한 슬러지의 Break-up 원인과 부상 특성 (Cause of Break-up and Flotation Characteristics for Sludge from DAF Process)

  • 유영훈;문용택;김성진;이광준;곽동희
    • 상하수도학회지
    • /
    • 제24권5호
    • /
    • pp.527-536
    • /
    • 2010
  • Although the bubble-floc agglomerate floated and formed the float layer on the surface of the water in the DAF process, after inducing in the thickening tank a part of the bubble-floc agglomerate come up again to the surface and the other is settled at the bottom of the tank. The bubble-floc agglomerate divided into two group as the scum on the surface and the sludge of the bottom gives rise to operational troubles for the thickening process. In order to find out the cause of break-up and the effective thickening method for sludge from the DAF process, the composition of the bubble-floc agglomerate was investigated and a series of flotation experiments carried out. There was no difference of composition between the scum on the surface and the sludge of the bottom in the thickening tank. The coagulation was not effective to improve the trouble that the bubble-floc agglomerate divided into the scum and the sludge. It was estimated that for the bubble-floc agglomerate of thickening tank the trouble was caused by not the change or the difference of chemical composition but whether the bubble-floc agglomerate hold bubbles. Furthermore, for the effective thickening of sludge from the DAF process, it is required an additional flotation applied the AS ratio depending upon the solid concentration of sludge as the operation parameter.

EXPERIMENTAL AND ANALYTICAL STUDIES ON THE INSTABILITY IN THE LZCS FOR CANDU REACTORS

  • Ji, Joon-Suk;Lee, Kwang-Ho;Yun, Bum-Su;Cha, Jung-Hun;Kim, Sang-Nyung
    • Nuclear Engineering and Technology
    • /
    • 제40권7호
    • /
    • pp.561-570
    • /
    • 2008
  • When reactivity insertion such as refueling occurs in CANDU reactors, the power and the water levels are tilted in the upper outer zone of the LZCS (Liquid Zone Control System) and fluctuate unstably for a certain period of time (1-5 days). The instability described above is observed in most CANDU reactors in service around the world, but its root cause is unidentified and no solutions to this problem have been established. Therefore, this study attempted to prove experimentally and analytically that the root cause lies in the hold-up of light water on the top of the TSP (Tube Support Plate) due to the mismatch between net volumetric flow rate of light water and helium crossing the narrowed porous TSP installed within the LZCS compartment. Our method was to perform a hydrodynamic simulation of in/outflow of light water and helium. Two solutions for the aforementioned instability of LZCS are suggested. One is to regulate the compartment for both inflowing helium gas and outflowing light water; the other is to enlarge the flow paths of helium and light water within TSP. The former may be applicable to nuclear reactors in service and the latter to those planned for construction.

표면특성에 따른 물맺힘 특성이 가스흡착성에 미치는 영향 (The Effect on Gas Adsoption Efficiency for Various Surface Characteristics)

  • 허경욱;신종민
    • 설비공학논문집
    • /
    • 제14권8호
    • /
    • pp.671-675
    • /
    • 2002
  • The gas adsorption efficiency for various surfaces with three different characteristics has been reviewed. The dimethyl disulfide gas has been used to investigate characteristics of gas adsorption for different surface characteristics such as plasma treated, lacquer coated and untreated. Three different surfaces were evaluated in dry conditions initially and tested at wet surface conditions with spraying water to evaluate the gas adsorption efficiency which usually occurred at defrost cycles. The results show that the gas adsorption of the plasma treated sample has better performance than others. The lacquer coated and untreated samples showed the similar result, but the lacquer coated sample showed a slightly better performance.