• 제목/요약/키워드: Water film model

검색결과 131건 처리시간 0.031초

순환여과식 해산 어류 양식장의 수처리 공정 최적화 연구 1. 회전원판법에 의한 해수 중의 암모니아 제거 동력학 (Optimization Studies on Water Treatment Process of Seawater Recirculation Fish Culture Systems 1. Ammonia Removal Kinetics in Seawater Using Rotating Biological Contactor Process)

  • 조영개;이재관;이헌모;양병수
    • 한국양식학회지
    • /
    • 제6권4호
    • /
    • pp.311-321
    • /
    • 1993
  • Ammonia accumulation is regarded as the limiting factor of the first priority in water qualities of aquatic culture systems. Nitrification efficiency and characteristics in seawater were evaluated using Rotating Biological Contactor (RBC) process as a part of the recycling water treatment facilities for marine fish culture system. Ammonia removal efficiency regarded 99.7 to $83.7\%$ at the ammonia surface loading rates of 48 to $393 mg/m^2$ -day. RBC process was able to withstand to the fluctuation of influent ammonia concentrations and loading and produced the stable effluent. The mathematical model on the fixed-film biological reactor developed by Kornegay seemed to be suitable to RBC process kinetic evaluation for the recycling water treatment of the marine fish culture system. Area capacity constant (P) and half-velocity constant (Ks) in the model were 0.188g/m^2$-day and 1.25mg/l, respectively.

  • PDF

3차원 착빙 형상 예측을 위한 2세대 시뮬레이션 코드 개발 (DEVELOPMENT OF 2ND GENERATION ICE ACCRETION ANALYSIS PROGRAM FOR HANDLING GENERAL 3-D GEOMETRIES)

  • 손찬규;오세종;이관중
    • 한국전산유체공학회지
    • /
    • 제20권2호
    • /
    • pp.23-36
    • /
    • 2015
  • The $2^{nd}$ generation ice accretion analysis program has been developed and validated for various icing conditions. The essential feature of the $2^{nd}$ generation code lies in its capability of handling general 3-D geometry and improved accuracy. The entire velocity fields are obtained based on Navier-Stokes equations in order to take the massively separated flow field into account. Unlike $1^{st}$ generation code, the droplet trajectories are calculated using Eulerian approach, which is adopted to yield appropriate collection efficiency even in the shadow region. For improved thermodynamic analysis on the surfaces, water film model and modified Messinger model are newly included in the present analysis. The ice shape for a given time step is obtained by considering the exact amount of ice accreted on the surface. Each module of the icing analysis code has been seamlessly integrated on the OpenFOAM platform. The developed code was validated against available experimental data for 2D airfoils and 3D DLR-F4. Due to the lack of experimental data, the computed results of DLR-F4 were compared with those obtained from FENSAP-ICE, which is state-of-the-art 3D icing analysis code. It was clearly shown that the present code produces comparable results to those of FENSAP-ICE, in terms of prediction accuracy and the capability of handling general 3-D geometries.

Modeling of Pressure Drop for Water Vapor Flow across Tube Banks inside Horizontal Tube Absorber

  • Phan Thanh Tong;Yoon Jung-In;Kim Eun-Pil
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제30권4호
    • /
    • pp.483-493
    • /
    • 2006
  • A model for a pressure drop of water vapor flow across tube banks in a horizontal tube absorber of an absorption chiller/heater using LiBr solution as a working fluid has been developed based on a commercial 20RT(70kW) absorption chiller/heater. The numerical results show that the characteristic of the pressure drop in the shell side of the horizontal tube absorber is completely different from that in a conventional shell and tube heat exchanger. Especially, solution film thickness has significant influence on the vapor pressure drop in the horizontal tube absorber. In addition, the effects by the tube diameters, the longitudinal pitch to diameter ratio, and Reynolds number of the vapor flow, on the vapor pressure drop have been studied to evaluate the compactness of tube absorber. It was found that the vapor pressure drop decreases as tube diameter increases, the longitudinal pitch to diameter ratio increases, and Reynolds number of the vapor flow decreases. A comparison of the present study results with well-established experimental and numerical results showed a good overall agreement.

얇은 수직 사각유로에서의 포화비등조건 임계열유속 예측 (Prediction of Critical Heat Flux for Saturated Flow Boiling Water in Vertical Narrow Rectangular Channels)

  • 최길식;장순흥;정용훈
    • 대한기계학회논문집B
    • /
    • 제39권12호
    • /
    • pp.953-963
    • /
    • 2015
  • 산업적으로 얇은 사각유로에서의 임계열유속을 포함한 열수력 현상을 이해하고 이를 시스템 설계에 반영해야 될 필요성이 증대되고 있다. 포화비등조건에서 임계열유속이 발생하는 주요기구는 일반적으로 환상유동 영역에서 액막이 건조되는 것이다. 이러한 임계열유속을 예측하기 위하여 원형관에 대한 대표적인 액막건조모델을 고찰하고 환상유동 시작 경계조건을 상수로 가정하는 기존 모델의 한계를 살펴보았다. 균일한 열유속으로 가열되는 얇은 수직사각유로 상향유동에서의 임계열유속을 예측하기 위하여 환상유동을 단순 모델링하고, 새로운 액막건조모델을 적용하였다. 284 개 실험데이타에 대한 예측성능을 확인한 결과 MAE 18.1%, RMSE 22.9% 예측오차로 실험데이타를 잘 예측할 수 있음을 확인하였다.

Performance prediction of flat sheet commercial nanofiltration membrane using Donnan-Steric Pore Model

  • Qadir, Danial;Nasir, Rizwan;Mukhtar, Hilmi;Uddin, Fahim
    • Membrane and Water Treatment
    • /
    • 제12권2호
    • /
    • pp.59-64
    • /
    • 2021
  • The rejection of sodium chloride (NaCl) and calcium chloride (CaCl2) single salt solutions were carried out for commercial nanofiltration NFDK membrane. Results showed that the NFDK membrane had a negative surface charge and had a higher observed rejection of 93.65% for calcium (Ca2+) ion and 78.27% for sodium (Na+) ions. Prediction of rejection for aqueous solutions of both salts was made using Donnan Steric Pore Model based on Extended Nernst-Planck Equation in addition to concentration polarization film theory. A MATLAB program was developed to execute the model calculations. Absolute Average Relative Error (% AARE) was found below 5% for real rejection of the NFDK membrane. This research could be used successfully to assess the membrane characterization parameter using a proposed procedure which can reduce the number of experiments.

상동광산 광미를 혼합한 시멘트 페이스트의 레올로지 특성 (Rheological Properties of Cement Paste Containing Tailings in Sangdong Mine)

  • 최연왕;정문영;정명채;구기정
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2004년도 춘계 학술발표회 제16권1호
    • /
    • pp.616-619
    • /
    • 2004
  • This study has focused on the possibility for recycling of tailings from the Sangdong tungsten mine as powder. The experimental tests for entrapped water ratio were carried out in accordance with the specificed method by Okamura. The rheological measurements of cement paste were conducted by using a commerically digital Brookfield viscometer (Model LVDV-II+) equipped with cylindrical spindles. The results of this study, in case of cement paste mixed with tailings, entrapped water ratio was decreased with increasement of mixing ratio. Thickness of pseudo water film was increased, and mean plastic viscosity was decreased with increasing replacement.

  • PDF

DMPC LB박막의 유전완화현상 (Dielectric Relaxation Phenomena of DMPC LB Thin Film)

  • 최영일;송진원;조수영;이경섭
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2003년도 하계학술대회 논문집 Vol.4 No.2
    • /
    • pp.822-825
    • /
    • 2003
  • Maxwell displacement current (MDC) measurement has been employed to study the dielectric property of Langmuir-films. A method for determining the dielectric relaxation time $\tau$ of floating monolayers on water surface is presented. WC flowing across monolayers is analyzed using a rod-like molecular model. It is revealed that the dielectric relaxation time $\tau$ of monolayers in the isotropic polar orientational phase is determined using a liner relationship between the monolayer compression speed ${\alpha}$ and the molecular area Am. Compression speed ${\alpha}$ was about 30, 40, 50mm/min.

  • PDF

전기아연도금 강에서 미세조직 및 표면유막이 용접 spatter에 미치는 영향 (Effects of Microstructure and Surface Oil Film on the Welding in Zr Electroplated steel)

  • 최한철;최수찬;김광연;안덕수;김영우
    • 한국표면공학회지
    • /
    • 제30권1호
    • /
    • pp.13-22
    • /
    • 1997
  • In order to investigate the effects of microstructure Oil film on the welding spatter in Zn electroplated steel, Zn electroplated surface and layer structure with USS-Paddition was observed using XRD, XPS and optical microscopy. Wettability of water drop on the Zn electroplated steel surface was measured using Z.Mei model. Oil absorption test was carried out using Oil pen. Morphology of spot welding and spatter with USS-P addition, applied current, and oil-spray or oil-without was observed using SEM and optical microscopy. Surface morphology of Zn electroplated steel showed finer structure as USS-P content increased. Wettabiliy on the Zn electroplated surface decreased with increasing USS-P content. Size of welding trace increased and spatter occured arround the welding part as applied current increased, whereas spatter disappeared as USS-P content increased and disappeared in case of oil spraying on the Zn electroplated surface.

  • PDF

미세 유체 상 PDMS 고분자 필름의 펨토초 레이저 어블레이션 및 천공 임계치 연구 (fs-laser Ablation and Optoperforation Threshold for PDMS Thin Film on $\mu$-channel)

  • 우숙이;;윤태오;정세채;박일홍
    • 한국정밀공학회지
    • /
    • 제27권2호
    • /
    • pp.29-33
    • /
    • 2010
  • We have investigated fs-laser ablation as well as optoperforation threshold of PDMS (Polydimethylsiloxane) thin lid cover on ${\mu}$-channel with changing the flow medium from water to hemoglobin. The ablation threshold is found to be independent of both PDMS thin film thickness and flow medium, but the optoperforation threshold is dependent on the films thickness. The observation that the ablation process is well described with simple two-temperature model supposed that the cover lid PDMS of $\mu$-channel be processed with minimized thermal effects by fs-laser with low laser fluence.

Development of Heat Transfer and Evaporation Correlations for the Turbulent Natural Convection in the Vertical Channel by Using Numerical Analysis

  • Kang, Han-Ok;Lee, Un-Chul
    • Nuclear Engineering and Technology
    • /
    • 제28권6호
    • /
    • pp.532-541
    • /
    • 1996
  • Theoretical and numerical study on heat transfer and evaporation in the vertical channel has been carried out and basic correlations have been derived for the heat transfer evaluation of PCCS. Analysis program was developed with low-Reynolds-number k-$\varepsilon$ model and surface transfer rates were calculated for the turbulent natural convection in the vertical channel. In relation to dry cooling by buoyancy-driven air, first, the system parameters which govern overall heat transfer rate are determined through the adequate nondimensionalization procedure. After comparison with existing experimental data, numerical results are used to derive heat transfer correlation by sensitivity calculations. In relation to wet cooling by falling water film, numerical analysis are carried out for evaporation process with real film surface conditions and evaporation correlation is derived through analogy concept and correction factors.

  • PDF