• 제목/요약/키워드: Water exit

검색결과 191건 처리시간 0.027초

자율 주행형 급수 배관 검사 (An automatic motorized feeder pipe inspection robot)

  • 최창환;전풍우;최용제;정승호;김승호
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 춘계학술대회
    • /
    • pp.816-821
    • /
    • 2004
  • The outlet feeder pipe thinning in a PHWR (Pressured Heavy Water Reactor) is caused by high pressure steam flow inside the pipe, which is a well known degradation mechanism called FAC (Flow Assisted Corrosion). In order to monitor the degradation, the thickness of the outlet bends closed to the exit of the pressure tube should be measured and analyzed at every official overhaul. This paper develops an automatic feeder pipe inspection system that can minimize the irradiation dose by automating the measurement process. The robot can move by itself on the feeder pipe by using an inch worm mechanism, which is constructed by two gripper bodies that can fix their body on the pipe and one extendable and retractable body connected the two gripper bodies to move forward and backward.

  • PDF

2차원 원심 압축기의 깃 없는 디퓨저에서의 불안정 유동 (Unstable Flow in a Vaneless Diffuser of 2-Dimensional Centrifugal Compressor)

  • 강경준;신유환;김광호;이윤표
    • 한국유체기계학회 논문집
    • /
    • 제14권4호
    • /
    • pp.5-11
    • /
    • 2011
  • This study investigated on details of flow characteristics in a vaneless diffuser of a compressor with 2-dimensional impeller at various flow rates. Experiment for a low speed compressor model in a water reservoir was performed to analyze the flow field in the vaneless diffuser and volute casing, which was done by PIV measurement. It was also focused on the periodic flow patterns occurring at low flow rate near unstable operating region of the compressor. At low flow rate condition, the flow visualization clearly shows that the flow energy from impeller is highly accumulated at the compressor exit by the blockage effect of a flow damper and consequently the reverse flow occurs in the diffuser.

고분자전해질형 연료전지의 작동 온도에 따른 공기극 유로 내 플러딩 현상에 관한 연구 (A Study on the Flooding Phenomena of Cathode Flow Path with Operating Temperatures in a PEM Fuel Cell)

  • 김한상;하태훈;민경덕
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2005년도 춘계학술대회
    • /
    • pp.326-329
    • /
    • 2005
  • Proton exchange membrane (PEM) should be sufficiently hydrated with proper water management to maintain a good ionic conductivity and performance of a PEM fuel cell. However. cathode flooding resulting from excess water can impede the transport of reactants and hence deteriorate the fuel cell performance. For the PEM fuel cell to be commercially viable as vehicle or portable applications, the flooding on the cathode side should be minimized during the fuel cell operation. In this study, visualization technique was applied to understand the cathode flooding phenomena on the cathode side of a PEM fuel cell. To this end. a transparent PEM unit fuel cell wi th an act ive area of $25cm^2$ was designed and manufactured to allow for the visualization of cathode channel with performance characteristics. Two-phase flow resulting from the electro-chemical reaction of fuel cell was investigated experimentally. The images photographed by CCD camera with cell operating temperatures $(30\~50^{\circ}C)$ were presented. Results indicated that the flooding on the cathode side first occurs near the exit of cathode channel. As the operating temperature of fuel cell increases. it was found that liquid water droplets tend to evaporate easily and it can have an influence on lowering the flooding level. It is expected that this study can effectively contribute to the detailed researches on modeling water transport of an operating PEM fuel cell including two-phase flow phenomena.

  • PDF

Estimation of optimal ecological flowrates for fish habitats in a nature-like fishway of a large river

  • Kim, Jeong-Hui;Yoon, Ju-Duk;Baek, Seung-Ho;Jang, Min-Ho
    • Journal of Ecology and Environment
    • /
    • 제39권1호
    • /
    • pp.43-49
    • /
    • 2016
  • Fishways are constructed to provide longitudinal connectivity of streams or rivers where their flow has been altered by in-stream structures such as dams or weirs. Nature-like fishways have an additional function of providing fish habitats. In the study, we estimated the role of a nature-like fishway (length: 700 m, slope: 1/100) for fish habitat by using two dominant species in the Sangju Weir, Nakdong River, to calculate the optimal ecological flow rate using Physical HABitat SIMulation (PHABSIM). To identify the dominant species that used the fishway, we conducted trap monitoring from August to November 2012 at the fishway exit. The dominant species were Zacco platypus and Opsariichthys uncirostric amurensis with a relative abundance of 62.1% and 35.9%, respectively. Optimal habitat suitability indices (HSIs) for Z. platypus and O. u. amurensis were calculated as 0.6-0.8 m/s (water velocity) and 0.2-0.4 m (water depth), and 0.5-0.7 m/s (water velocity) and 0.1-0.3 m (water depth), respectively. The optimal ecological flow rates (OEFs) for Z. platypus and O. u. amurensis were 1.6 and 1.7 cubic meter per second (CMS), respectively. The results of the study can be used in a management plan to increase the habitat function of nature-like fishways in the Sangju Weir. This methodology can be utilized as an appropriate tool that can determine the habitat function of all nature-like fishways.

Large Scale Treatment of Perfluorocompounds Using a Thermal Plasma Scrubber

  • Han, Sung-Han;Park, Hyun-Woo;Kim, Tae-Hee;Park, Dong-Wha
    • 청정기술
    • /
    • 제17권3호
    • /
    • pp.250-258
    • /
    • 2011
  • Thermal plasma has been presented for the decomposition of perfluorocompounds (PFCs) which are extensively used in the semiconductor manufacturing and display industry. We developed pilot-scale equipment to investigate the large scale treatment of PFCs and called it a "thermal plasma scrubber". PFCs such as $CF_4$, $C_2F_6$, $SF_6$, and $NF_3$ used in experiments were diluted with $N_2$. There were two different types of experiment setup related to the water spray direction inside the thermal plasma scrubber. The first type was that the water was sprayed directly into the gas outlet located at the exit of the reaction section. The second type was that the water was sprayed on the wall of the quenching section. More effective decomposition took place when the water was sprayed on the quenching section wall. For $C_2F_6$, $SF_6$, and $NF_3$ the maximum destruction and removal efficiency was nearly 100%, and for $CF_4$ was up to 93%.

Numerical Simulation of Unsteady Cavitation in a High-speed Water Jet

  • Peng, Guoyi;Okada, Kunihiro;Yang, Congxin;Oguma, Yasuyuki;Shimizu, Seiji
    • International Journal of Fluid Machinery and Systems
    • /
    • 제9권1호
    • /
    • pp.66-74
    • /
    • 2016
  • Concerning the numerical simulation of high-speed water jet with intensive cavitation this paper presents a practical compressible mixture flow method by coupling a simplified estimation of bubble cavitation and a compressible mixture flow computation. The mean flow of two-phase mixture is calculated by URANS for compressible fluid. The intensity of cavitation in a local field is evaluated by the volume fraction of gas phase varying with the mean flow, and the effect of cavitation on the flow turbulence is considered by applying a density correction to the evaluation of eddy viscosity. High-speed submerged water jets issuing from a sheathed sharp-edge orifice nozzle are treated when the cavitation number, ${\sigma}=0.1$, and the computation result is compared with experimental data The result reveals that cavitation occurs initially at the entrance of orifice and bubble cloud develops gradually while flowing downstream along the shear layer. Developed bubble cloud breaks up and then sheds downstream periodically near the sheath exit. The pattern of cavitation cloud shedding evaluated by simulation agrees experimental one, and the possibility to capture the unsteadily shedding of cavitation clouds is demonstrated. The decay of core velocity in cavitating jet is delayed greatly compared to that in no-activation jet, and the effect of the nozzle sheath is demonstrated.

수중초음속제트의 불안정성에 대한 실험적 고찰 (Experimental Observation of Instability of Supersonic Submerged Jets)

  • 정재권;이대훈;차홍석;박승오;권세진
    • 한국추진공학회지
    • /
    • 제6권2호
    • /
    • pp.45-52
    • /
    • 2002
  • 2차원 수중 초음속 제트의 구조 및 유동 불안정성에 대한 실험적 연구를 수행하였다. 제트의 구조 및 시간에 따른 변화를 관찰하기 위하여 고속 디지털 카메라 촬영과 정압을 측정하였다. 공기 유량의 변화에 따른 제트의 구조를 초고속 촬영하여 이로부터 얻어진 장면에서 확산각을 구했다. 일련의 제트의 주기적인 특성에 따른 구조를 관찰하였고 불안정성의 초당 주기 발생 횟수가 5-6회 정도로 측정되었다. 세 가지 특성 길이 $L_1$, $L_2$, $L_3$를 정의하였다. $L_1$은 불안정적 주기가 발생할 경우 최대제트의 폭 스케일, $L_2$는 2차적인 유동이 유입되는 곳의 제트의 폭 스케일, $L_3$는 노즐 출구로부터 2차적으로 유도된 유동이 유임되는 곳까지의 길이다. $L_1$/$L_2$는 전압 즉, 탱크 압력이 증가함에 따라 감소하는 경향성을 가지고 있고 $L_3$는 전압이 증가함에 따라 증가하는 경향성을 띄었다. 시간에 따른 정압 변화를 측정하였으며 FFT결과를 통해서 불안정성으로 인해 발생하는 주파수와 유사한 값인 5Hz에서 고유진동이 발생하는 것을 확인하였다.

SOEC에 과열기의 고온 스팀을 공급하는 Interface의 열전달에 관한 전산해석 (A CFD Analysis on Heat Transfer of High Temperature Steam through Interface with Superheater and SOEC for Hydrogen Production)

  • 변현승;한단비;박성룡;조종표;백영순
    • 한국수소및신에너지학회논문집
    • /
    • 제31권2호
    • /
    • pp.169-176
    • /
    • 2020
  • There is a growing interest in hydrogen energy utilization since an alternative energy development has been demanded due to the depletion of fossil fuels. Hydrogen is produced by the reforming reaction of natural gas and biogas, and the electrolysis of water. An solid oxide electrolyte cell (SOEC) is reversible system that generates hydrogen by electrolyzing the superheated steam or producing the electricity from a fuel cell by hydrogen. If the water can be converted into steam by waste heat from other processes it is more efficient for high-temperature electrolysis to convert steam directly. The reasons are based upon the more favorable thermodynamic and electrochemical kinetic conditions for the reaction. In the present study, steam at over 180℃ and 3.4 bars generated from a boiler were converted into superheated steam at over 700℃ and 3 bars using a cylindrical steam superheater as well as the waste heat of the exhaust gas at 900℃ from a solid refuse fuel combustor. Superheated steam at over 700℃ was then supplied to a high-temperature SOEC to increase the hydrogen production efficiency of water electrolysis. Computational fluid dynamics (CFD) analysis was conducted on the effects of the number of 90° elbow connector for piping, insulation types and insulation layers of pipe on the exit temperature using a commercial Fluent simulator. For two pre-heater injection method of steam inlet and ceramic wool insulation of 100 mm thickness, the highest inlet temperature of SOEC was 744℃ at 5.9 bar.

가스 엔진 배열을 이용한 유기랭킨사이클 시스템의 열역학적 해석 (Thermodynamic Analysis on Organic Rankine Cycle using Exhaust Heat of Gas Engine)

  • 성태홍;윤은구;김현동;최정환;채정민;조영아;김경천
    • 한국가스학회지
    • /
    • 제19권2호
    • /
    • pp.66-73
    • /
    • 2015
  • 가솔린 엔진에서 개조된 가스 엔진에서 발생하는 냉각수와 배기가스를 분석하여 복합발전 시스템에서 활용 가능한 폐열의 양과 질을 확인하였다. 엔진 배기가스의 온도는 $573.8^{\circ}C$이고, 엔진 출구 냉각수의 온도는 $85.7^{\circ}C$이고, 폐열의 양은 엔진 냉각수가 배기가스에 비교하여 두 배 수준이었다. 두 가지 폐열의 상이한 온도와 양에 대응하는 유기랭킨사이클 (Organic Rankine Cycle: ORC) 발전시스템을 설계하고 열역학적 분석을 수행하였다.

A Method for Critical Heat Flux Prediction in Vertical Round Tubes with Axially Non-uniform Heat Flux Profile

  • 심재우
    • 한국해양공학회지
    • /
    • 제22권1호
    • /
    • pp.13-21
    • /
    • 2008
  • In this study a method to predict CHF(Critical heat flux) in vertical round tubes with axially non-uniform cosine heat flux distribution for water was examined. For this purpose a local condition hypothesis based CHF prediction correlation for uniform heat flux in vertical round tubes for water was developed from 9,366 CHF data points. The local correlation consisted of 4 local condition variables: the system pressure(P), tube diameter(D), mass flux of water(G), and 'true mass quality' of vapor($X_t$). The CHF data points used were collected from 13 different published sources having the following operation ranges: 1.01 ${\leq}$ P (pressure) ${\leq}$ 206.79 bar, 9.92${\leq}$ G (mass flux) ${\leq}$ 18,619.39 $kg/m^2s$, 0.00102 ${\leq}$ D(diameter) ${\leq}$ 0.04468 m, 0.0254${\leq}$ L (length) ${\leq}$ 4.966 m, 0.11 ${\leq}$ qc (CHF) ${\leq}$ 21.41 $MVW/m^2$, and -0.87 ${\leq}X_c$ (exit qualities) ${\leq}$ 1.58. The result of this work showed that a uniform CHF correlation can be easily extended to predict CHF in axially non-uniform heat flux heater. In addition, the location of the CHF in axially non-uniform tube can also be determined. The local uniform correlation predicted CHF in tubes with axially cosine heat flux profile within the root mean square error of 12.42% and average error of 1.06% for 297 CHF data points collected from 5 different published sources.