• 제목/요약/키워드: Water evaporation

검색결과 966건 처리시간 0.023초

증발수 유량이 간접 증발식 냉각기 성능에 미치는 영향 (Effects of Evaporation Water Flow Rate on the Performance of an Indirect Evaporative Cooler)

  • 추현선;이관수;이대영
    • 설비공학논문집
    • /
    • 제18권9호
    • /
    • pp.714-721
    • /
    • 2006
  • In evaporative cooling applications, the evaporation water is supplied usually sufficiently larger than the amount evaporated to enlarge contact surface between the water and the air. Especially in indirect evaporative coolers, however, if the evaporation water flow rate is excessively large, the evaporative cooling effect is not used for heat absorption from the hot fluid but spent to the sensible cooling of the evaporation water itself. This would result in a decrease in the cooling performance of the indirect evaporative cooler. In this study, the effects of the evaporation water flow rate on the cooling performance are investigated theoretically. The cooling process in an indirect evaporative cooler is modeled into a set of linear differential equations and solved to obtain the exact solutions to the temperatures of the hot fluid, the moist air, and the evaporation water. Based on the exact solutions, it is analyzed how much the cooling performance is affected by the evaporation water flow rate. The results show that the decrease in the cooling effectiveness is substantial even for a small flow rate of the evaporation water and the relative decrease is more serious for a high-performance evaporative cooler.

Modelling of evaporation from free water surface

  • Song, Wei-Kang;Chen, Yibo
    • Geomechanics and Engineering
    • /
    • 제21권3호
    • /
    • pp.237-245
    • /
    • 2020
  • The process of evaporation from free water surface was simulated in a large scale environmental chamber under various controlled atmospheric conditions and also was modelled by a new mass transfer model. Six evaporation tests were conducted with increasing wind speed and air temperature in the environmental chamber, and hence the effect of atmosphere parameters on the evaporation process and the corresponding response of water were investigated. Furthermore, based on the experiment results, seven general types of mass transfer models were evaluated firstly, and then a new model consisted of wind speed function and air relative humidity function was proposed and validated. The results show that the free water evaporation is mainly affected by the atmospheric parameters and the evaporation rate increases with the increasing air temperature and wind speed. Both the air and soil temperatures are affected by the energy transformation during water evaporation. The new model can satisfactorily describe the evaporation process from free water surface under different atmospheric conditions.

대형증발계 증발량의 일 변화 (Short-term Variation in Class A Pan Evaporation)

  • 이부용
    • 한국농림기상학회지
    • /
    • 제4권4호
    • /
    • pp.197-202
    • /
    • 2002
  • A new method is used to estimate the amount of water evaporation from Class A Pan with higher precision and accuracy. The principle of method is to detect the weight change of a buoyant sinker resulting from a change in water level of Class A Pan. A strain-gauge load cell is used to measure the weight change. Field observation of evaporation was done at Pohang Meteorological Station from June 24 to August 4, 2002. By using this new method, it is possible to measure hourly evaporation accurately even under a strong solar radiation and wind disturbance, enabling a direct comparison of evaporation with other meteorological elements. At night, under low humidity and high wind speed conditions, more evaporation was recorded than during daytime. Maximum evaporation rates observed during this period exceed 1.0 mm/hour under the sunny and windy conditions with low humidity. To understand relationships between meteorological elements and latent heat flux at ground level, we suggest intensive held experiments using high accuracy evaporation recording instruments with hourly time interval.

재생증발식 수냉각기의 냉각성능 해석 (Investigation on the Cooling Characteristics of a Regenerative Evaporation Water Cooler)

  • 최봉수;홍희기;이대영
    • 설비공학논문집
    • /
    • 제18권5호
    • /
    • pp.393-401
    • /
    • 2006
  • The regenerative evaporation water cooler is devised and analysed in this study. The regenerative evaporation water cooler is composed of a sensible heat exchanger to cool the incoming air, followed by a latent heat exchanger to cool the water evaporatively with the cooled air flowing out of the sensible heat exchanger. By linearizing psychrometric characteristics, the heat and mass transfer in the regenerative evaporation water cooler is analyzed theoretically. The results show that the water can be cooled down even lower than the wet-bulb temperature of the inlet air. When the inlet air is $32^{\circ}C$ and 20% in relative humidity, and the inlet temperature of the water is $20^{\circ}C$, the regenerative evaporation water cooler provides a larger cooling capacity than the conventional evaporation water cooler if the effectiveness of the latent heat exchanger is higher than 0.6 and that of the sensible heat exchanger is higher than 0.5.

대형증발계용 매시간 증발 기록계 개발에 관한 연구 (A Study on the Development of Hourly Evaporation Recording Instrument for Class A Pan)

  • 이부용
    • 한국환경과학회지
    • /
    • 제10권5호
    • /
    • pp.323-327
    • /
    • 2001
  • A new method is developed to estimate the evaporation of water from a surface with high accuracy and resolution. The principle of new method is to detect a weight change of buoyant weight according to a change in water level of Class A Pan mesured by the use of a strain-gauge load cell. Field test of evaporation recording new instrument was carried out at Suwon for 10 days July 1999. It is possible in field observation to measure hourly evaporation amount by newly developed evaporation recording instrument in Class A Pan against strong solar radiation. Present study provide a possibility of domestic high accuracy instrument development below than 0.1mm water level measurement accuracy. If there is low humidity and high wind speed conditions which is possible to evaporate from water surface during night time. And it needs continuous study to understand between meteorological elements and latent heat effect at ground level by field observation study using high accuracy evaporation recording instrument.

  • PDF

초등학교 학생들의 증발과 응결 개념에 대한 연구 (Study on students과 concepts of evaporation and condensation in elementary school)

  • 이용복;이성미
    • 한국초등과학교육학회지:초등과학교육
    • /
    • 제17권1호
    • /
    • pp.89-103
    • /
    • 1998
  • We study that what kind of the concepts of evaporation and condensation students of elementary school have. The results are following. (1) The students have simple concepts of evaporation on natural circumstance. However, they don't understand about various effect on evaporation. (2) They don't know where the evaporized water is comming from. (3) They have experiences on observing condensation of wale. (70%), however don't know that the water is evaporized in the air. (4) They have more understanding about evaporation, more correct concepts on condensation in circulation of water.

  • PDF

해남 농경지에서의 자유 수면 증발 관측과 해석 (Measurement and Analysis of Free Water Evaporation at HaeNam Paddy Field)

  • 한진수;이부용
    • 한국농림기상학회지
    • /
    • 제7권1호
    • /
    • pp.91-97
    • /
    • 2005
  • BYL-EV250 증발기록계를 이용하여 해남 농경지역의 자유 수면 증발량을 관측하였고, 그 자료를 분석하여, 기상 요소와 증발량과의 관계를 분석하였다. 자연상태에서 증발량을 결정하는 기상요소의 관계를 살펴보고, 그 결과를 바람과 포차의 경험식으로 나타내었다. 이 식을 이용하여 자유 수면으로부터의 시간당 증발량을 구할 수 있었으며 수온, 기온, 습도, 풍속 같은 기상요소만으로 증발량 추정이 가능했다. 증발량 산출에 대한 신뢰성을 높이기 위해 지속적으로 수면에서의 물수지에 대한 연구가 수행되어야 할 것으로 사료된다. 증발량 관측도 다른 기상요소와 같이 매시간 관측 자료 생산 가능성을 시사했다. 부력을 이용한 측정방법은 미소 수위 변화(0.1mm 이하)를 측정 할 수 있어 대형증발계를 활용한 자동관측에 대한 신뢰성을 확보할 수 있었다. 이 결과를 바탕으로 장기간 관측된 자유수면 증발자료와 플럭스 타워에서 동시에 관측된 실제 증발산 자료의 비교분석이 현재진행 중에 있다.

친수성 표면처리가 수평관 외벽의 증발열전달에 미치는 영향 (Effects of Hydrophilic Surface Treatment on Evaporation Heat Transfer at the Outside Wall of Horizontal Tubes)

  • 박노성;황규대;강병하;정진택
    • 설비공학논문집
    • /
    • 제12권5호
    • /
    • pp.525-532
    • /
    • 2000
  • Evaporation heat transfer characteristics have been investigated experimentally when distilled water is sprayed on the outside wall of horizontal tubes in a evaporator. This problem is of particular interest in the design of evaporator of an absorption system. Hydrophilic surface treatment was employed to increase the wettability on copper tubes. The results indicate that evaporation heat transfer with hydrophilic tubes is shown to be 25-44% higher than that with bare tubes at evaporation pressure of 31.8 Torr(evaporation temperature$ 30^{\circ}C). Evaporation heat transfer rates of hydrophilic treatment tubes are improved substantially, comparing with those of conventional copper tubes in the wide range of operating parameters, such as water inlet temperatures, water mass flow rates and evaporation pressures.

  • PDF

Cascade-Correlation Algorithm을 이용한 증발접시 증발량의 모형화 (Pan Evaporation Modeling using Cascade-Correlation Algorithm)

  • 김성원
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 2005년도 학술발표회 논문집
    • /
    • pp.766-770
    • /
    • 2005
  • Cascade-Correlation Neural Networks Model(CCNNM) is used to estimate daily evaporation using limited climatical variables such as atmospheric temperature, dewpoint temperature, relative humidity, wind speed, sunshine duration and radiation. DeBruln equation is applied to estimate daily free-surface evaporation. It is converted into pan evaporation using pan coefficient. The results of CCNNM shows better than those of Debruin equation. This research represents that the strong nonlinear relationship such as evaporation modeling can be generalized by the CCNNM ; a special type of Backpropagation algorithm Neural Networks Model.

  • PDF

가습연소 폐열회수 보일러의 물분사 설계모델 구축에 관한 연구 (Establishing the Models for Optimized Design of Water Injection in Boilers with Waste-heat-recovery System)

  • 신재훈;문석수
    • 한국분무공학회지
    • /
    • 제26권2호
    • /
    • pp.96-103
    • /
    • 2021
  • In order to improve the overall efficiency and meet the emission regulations of boiler systems, the heat exchanging methods between inlet air and exhaust gas have been used in boiler systems, named as the waste-heat-recovery condensing boiler. Recently, to further improve the overall efficiency and to reduce the NOx emission simultaneously, the concept of the water injection into the inlet air is introduced. This study suggests the models for the optimized design parameters of water injection for waste-heat-recovery condensing boilers and performs the analysis regarding the water injection amount and droplet sizes for the optimized water injection. At first, the required amount of the water injection was estimated based on the 1st law of thermodynamics under the assumption of complete evaporation of the injected water. The result showed that the higher the inlet air and exhaust gas temperature into the heat exchanger, the larger the amount of injected water is needed. Then two droplet evaporation models were proposed to analyze the required droplet size of water injection for full evaporation of injected water: one is the evaporation model of droplet in the inlet air and the other is that on the wall of heat exchanger. Based on the results of two models, the maximum allowable droplet sizes of water injection were estimated in various boiler operating conditions with respect to the residence time of the inlet air in the heat exchanger.