• Title/Summary/Keyword: Water current energy

Search Result 688, Processing Time 0.038 seconds

Effect of Venturi System on Acceleration of Low-speed Water Flow at the Venturi Throat Installed at the Inlet of Hydro Turbine

  • Jung, Sang-Hoon;Seo, In-Ho;Kim, Chul-Ho
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.35 no.7
    • /
    • pp.914-920
    • /
    • 2011
  • For a hydro turbine electricity generation system in river or bay, a venturi system could be applied to accelerate flow speed at the inlet of the turbine system in a flow field. In this study, a steady flow simulation was conducted to understand the effect of venturi system on the acceleration of current speed at the inlet of a hydro turbine system. According to the continuity equation, the flow speed is inversely proportional to the cross-section area in a conduit flow; however, it would be different in an open region because the venturi system would be an obstruction in the flow region. As the throat area is 1/5 of the inlet area of the venturi, the flow velocity is accelerated up to 2.1 times of the inlet velocity. It is understood that the venturi system placed in an open flow region gives resistance to the upcoming flow and disperses the flow energy around the venturi system. The result of the study should be very important information for an optimum design of a hydro turbine electricity generation system.

Thermal Response Test (TRT) interpretation and the status in Korea (열응답 실험 해석 및 국내 현황)

  • Shim, Byoung Ohan;Choi, Choonghyun
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2010.06a
    • /
    • pp.168.2-168.2
    • /
    • 2010
  • The growing market for geothermal heat pump system requires great consideration of quality control and assurance in design and construction. The borehole heat exchanger of GHP system should be sustainable, economical and ecological. Thermal Response Test (TRT) is a useful method for site investigation to obtain reliable data for a optimal system design from the technical and economical aspect. Intensive researches combined with exchange of experiences on an international level within the IEA ECES Annex 21 improved the technology. Major subjects on the interpretation of TRT are development of improved evaluation models, evaluation of the TRT with respect to geological layers and investigation of the influence of ground water. Current status of TRT in South Korea, as well as a new version of the Korean TRT standard test procedure was presented. TRT is mostly used for governmental supported projects with corresponds to more than 100 GCHP systems per year. More than 200 tests are applied, mostly on single U-tube heat exchangers (about 95%). Bentonite is the most common grouting to be used. KIGAM (Korea Institute of Geoscience & Mineral Resources) is also keeping a GIS geological and geothermal database. In the institute also laboratory measurements of rock properties are carried out. About 90% of the laboratory measurements of the rock heat conductivity shows higher values than the in-situ TRT.

  • PDF

Experimental Validation of a Direct Methanol Fuel Cells(DMFCs) model with a Operating Temperatures and Methanol Feed Concentrations (직접메탄올 연료전지의 농도 및 온도변화에 따른 실험적 검증)

  • Kang, Kyungmun;Ko, Johan;Lee, Giyong;Ju, Hyunchul
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2010.06a
    • /
    • pp.125.2-125.2
    • /
    • 2010
  • In this paper, both theoretical and experimental investigations have been performed to examine the effects of key operating parameters on the cell performance of a DMFCs (i.e., methanol feed concentration and operating temperature). For experiment, the membrane electrode assemblies (MEAs) were prepared using a conventional MEA fabrication method based on a catalyst coated electrode (CCE) and tested under various cell temperatures and methanol feed concentrations. The polarization curve measurements were conducted using in-house-made $25cm^2$ MEAs. The voltage-current density data were collected under three different cell temperatures ($50^{\circ}C$, $60^{\circ}C$, and $70^{\circ}C$) and four different methanol feed concentrations (1 M, 2 M, 3 M, and 4 M). The experimental data indicate that the measured I-V curves are significantly altered, depending on these conditions. On the other hand, previously developed one-dimensional, two-phase DMFC model is simulated under the same operating conditions used in the experiments. The model predictions compare well with the experimental data over a wide range of these operating conditions, which demonstrates the validity and accuracy of the present DMFC model. Furthermore, both simulation and experimental results exhibit the strong influences of methanol and water crossover rates through the membrane on DMFC performance and I-V curve characteristics.

  • PDF

Study on Transient Response of a Unit Proton Exchange Membrane Fuel Cell with an Aged Gas Diffusion Layer (내구성능저하된 기체확산층이 고분자전해질 연료전지의 과도응답성능에 미치는 영향 연구)

  • Cho, Junhyun;Ha, Tahun;Park, Jaeman;Oh, Hwanyeong;Min, Kyoungdoug;Jyoung, Jy-Young;Lee, Eunsook
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2010.11a
    • /
    • pp.76.2-76.2
    • /
    • 2010
  • The gas diffusion layer is the key component of the proton exchange membrane fuel cell because it directly affect to the mass transport mechanism and dynamic behavior of the cell. In this study, the effects of GDL aging on the transient response of the PEM fuel cell is systematically investigated using current step transient response analysis under different stoichiometric ratios and humidity conditions. With GDLs aged by the accelerated stress test, the effects of hydrophobicity and structural changes due to carbon loss in the GDL on the transient response of PEM fuel cells are determined. The degraded GDLs that had uneven hydrophobicity distributions cause local water flooding inside the GDL and induce lower and unstable voltage responses after load changes.

  • PDF

Development of the submerged heat treatment machine for PBSAT(polybutylene succinate adipate-co-terephthalate) monofilament nets and its efficiency (수중 침지식 생분해성 PBSAT 그물 열처리기 개발과 성능 분석)

  • Park, Seongwook;Kim, Seonghun;Lim, Jihyun;Choi, Haesun
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.51 no.1
    • /
    • pp.94-101
    • /
    • 2015
  • The heat treatment machine based on immersion was developed to reduce temperature difference during netting process and appraised it performance compared current heat treatment machine using high pressure. It was also reviewed the optimum heat treatment procedures for PBSAT monofilament net in accordance with the immersion time and temperature. The procedure was based on physical measurement such as breaking load, elongation and angle of the mesh for PBSAT monofilament. The water temperature gap of the treatment machine based on immersion was less than $1^{\circ}C$. and the energy consumption was also increased in high temperature condition. It was identified that the optimum temperature was $75^{\circ}C$ and its optimum processing time was between 15 minutes and 20 minutes to get qualified physical properties.

처치온도에 따른 초미분화 산양삼의 홍삼화 연구

  • Kim, Jin-Ho;Kwon, Ki-Rok;Lee, Eun-Hee;Cha, Bae-Chun
    • Journal of Pharmacopuncture
    • /
    • v.9 no.3 s.21
    • /
    • pp.117-129
    • /
    • 2006
  • Objectives : The aim of this study was to find optimal conditions for producing red ginseng from cultivated wild ginseng using the Turbo Mill. Methods : Characteristics of powdered cultivated wild ginseng based on various temperature settings of the Turbo Mill were observed, and changes in the content was measured by HPLC for various ginsenosides. Results : 1. The diameter of cultivated wild ginseng powder ground by the Turbo Mill was around 10${\mu}m$. 2. As the temperature rose, pressure, Specific Mechanical Energy(SME), and density decreased, whileas Water Solubility Index(WSI) increased. 3. As the temperature rose, super fine powder showed tendency to turn into dark brown. 4. Measuring content changes by HPLC, there was no detection of ginsenoside Rg3 and ginsenosideRg1, Rb1, and Rh2 concentrations decreased with increase in temperature. Conclusions : Super fine powder of cultivated wild ginseng produced by the Turbo Mill promotes easy absorption of effective ingredients by breaking the cell walls. Using this mechanism to produce red ginseng from cultivated wild ginseng, it yielded less than satisfactory results under the current experiment setup. Further researches are needed to verify more suitable condition for the production of red ginseng.

Synthesis and Characterization of Mono-sulfonated Poly(ether sulfone) for a Fuel Cell Application (고분자 전해질 연료전지용 Sulfonated Poly(ether sulfone)의 합성 및 특성 평가)

  • Krishnan N.N.;Kim H.-J.;Prasanna M.;Cho E.-A.;Oh I.-H.;Hong S.-A.;Lim T.-H.
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.235-238
    • /
    • 2005
  • Sulfonated poly(ether sulfone) copolymers (PESs) were synthesized using hydroquinone 2-potassium sulfonate (HPS) with other monomers (bisphenol A and 4-fluorophenyl sulfone). PESs with different $mole\%$ of hydrophilic group were prepared by changing the mole ratio of HPS in the polymerization reaction. The chemical structure and the thermal stability of these polymers were characterized by using $^1H-NMR$, FT-IR and TGA techniques. The PES 60 membrane, which has $60 mole\%$ of HPS unit in the polymer backbone, has a proton conductivity of 0.091 S/cm and good insolubility in boiling water. The TGA showed that PES 60 was stable up to $272^{\circ}C$ with a char yield of about $29\%\;at\;900^{\circ}C\;under\;N_2$ atmosphere. To investigate the single cell performance, the catalyst coated PES 60 membrane was used and a single cell test was carried out using $H_2/O_2$ gases as fuel and oxidant at various temperatures. We observed that the cell performance was enhanced by increasing the cell temperature. A current density of $1400 mA/cm^2$ at 0.60 V was obtained at $70^{\circ}C$.

  • PDF

Mechanical Properties of Electro-Discharge-Sintered Porous Titanium Implants (전기방전소결에 의해 제조된 다공성 Titanium 임플란트의 기계적 특성)

  • Hyun, C.Y.;Huh, J.K.;Lee, W.H.
    • Korean Journal of Materials Research
    • /
    • v.16 no.3
    • /
    • pp.173-177
    • /
    • 2006
  • Porous surfaced Ti implant compacts were fabricated by electro-discharging-sintering (EDS) of atomized spherical Ti powders. Powders of $50-100{\mu}m$ in diameter were vibratarily settled into a quarts tube and subject to a high voltage and high density current pulse in Ar atmosphere. Single pulse of 0.7 to 2.0 kJ/0.7 gpowder, from 150, 300, and $450{\mu}F$ capacitors was applied in less than $400{\mu}sec$ to produce twelve different porous-surfaced Ti implant compacts. The solid core formed in the center of the compact shows similar microstructure of cp Ti which was annealed and quenched in water. Hardness value at the solid core was much higher than that at the particle interface and particles in the porous layer, which can be attributed to both heat treatment and work hardening effects induced by EDS. Compression tests were made to evaluate the mechanical properties of the EDS compacts. The compressive yield strength was in a range of 12 to 304MPa which significantly depends on input energy. Selected porous-surfaced Ti-6Al-4V dental implant compacts with a solid core have much higher compressive strengths compared to the human teeth and sintered Ti dental implants fabricated by conventional sintering process.

Studies for the Sustainable Management of Oyster Farms in Pukman Bay, Korea: Estimation of Carrying Capacity from Food Availability

  • Jeong, Woo-Geon;Cho, Sang-Man;Lee, Sang-Jun
    • Fisheries and Aquatic Sciences
    • /
    • v.12 no.2
    • /
    • pp.118-129
    • /
    • 2009
  • To develop a sustainable management model for oyster farming in Pukman Bay, Korea, we estimated the carrying capacity for oyster farming using food availability data. Optimal culture densities were calculated to be 124-133 individuals per unit flux area ($m^2$) and 310-330 individuals per string. The present annual production is approximately 1,038 tons/year, which is 87% of the estimated maximum yield of 1,193 tons/year. Therefore, considering annual fluctuations and a critical buffer to reduce ecological impacts, the current level is within optimal conditions. During periods of increased water temperature, energy demand was largely met by high primary production. The food supply significantly decreased as the harvest season approached, and 10 out of 21 oyster farms had a deficient food supply for at least 1 month. Therefore, these farms (39% of the farms within the bay) exceeded optimal densities.

Influence of the inlet oxygen humidity on PEMFC performance (산소 가습이 PEMFC 성능에 미치는 영향)

  • Lee, Seo-Hee;Moon, Cheor-Eon;Ko, Dong-Soo;Choi, Gyung-Min;Kim, Duck-Jool;Jung, Ji-Hwan
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2007.11a
    • /
    • pp.35-38
    • /
    • 2007
  • The comparisons between measured performance of lab-scale PEMFC and calculation were conducted to understand the detail phenomena of PEMFC for the various inlet oxygen humidity of cathode side. Experiments were performed at $65^{\circ}C$ operation temperature and different inlet humidity conditions such as 40%, 60% and 80%. We used the MEA manufactured by oneself which include $Nafion^{(R)}$ 112 membrane, Nafion solution 20%, and carbon paper(E-TEK). As a result of this experiment, cell performance was getting higher by increasing inlet humidity condition at cathode side because ion conductivity of electrolyte membrane is increased. A 3D CFD simulation model of PEMFC was developed using commercially available CFD code that is one of the STAR-CD module, es-pemfc under same operating conditions. Model calculations results were compared with experimental ones on the polarization curves and calculation results are in good agreement with the experimental ones. Local water distribution and current density inside PEMFC are discussed in detail.

  • PDF