• 제목/요약/키워드: Water conductivity

검색결과 1,928건 처리시간 0.029초

Correlation of electrical conductivity and color with water loss and shear force of pork loin

  • Hayeon Jeon;Seul-Ki-Chan Jeong;Seonmin Lee;Dongjun Kim;Hyeun Bum Kim;In-Seon Bae;Yunseok Kim;Pil Nam Seong;Samooel Jung;Kyung Jo
    • 농업과학연구
    • /
    • 제51권3호
    • /
    • pp.307-314
    • /
    • 2024
  • This study investigated the relationship of electrical conductivity and color to water loss and shear force of pork loin. In addition, the differences in quality properties with the sex and carcass grades were investigated. There were no differences in drip loss, cooking loss, and total loss of pork loin between barrow and gilt (p > 0.05). The shear force of pork loin was lower in barrow than in gilt (p < 0.05). The quality properties of pork loin did not differ among the carcass grades (1+, 1, and 2). The electrical conductivity measured at 45 min, 3 h, and 12 h had no noticeable correlation coefficients with the quality properties of pork loin. The L*, a*, and b* values correlated significantly with cooking loss and total loss. The highest correlation coefficient was 0.45 between L* and total loss. From the results, we conclude that the electrical conductivity and color values are not suitable variables for predicting pork loin quality. Therefore, further study to develop ways for predicting the pork quality during the grading of pork carcasses is required.

Air-Water 모델에서 기포특성에 관한 실험적 연구 (An Experimental Study on the Characteristics of Bubbles in Air-Water Model)

  • 오율권;서동표
    • 한국안전학회지
    • /
    • 제18권1호
    • /
    • pp.14-18
    • /
    • 2003
  • The structural development of air-water bubble plumes has been measured under different condition on air flow rate in a cylindrical bath. The time-averaged structure of plumes has been measured with an oscilloscope and an electro-conductivity probe. The temperature of bubbles was also obtained by a thermal-infrared camera. Gas volume fraction and bubble frequency were high since bubbles concentrated on the nozzle. In general, their axial and radial values tended to decrease with increasing distance. Bubble temperature reached water temperature within a short time. The present study showed that thermal equilibrium between bubbles and water was completed before bubbles flow became stable.

Application of Micropaticle Systems in Water Circuit Closure Programs

  • Howard Johnson;Ha, Derek A.rrington
    • 펄프종이기술
    • /
    • 제33권5호
    • /
    • pp.12-20
    • /
    • 2001
  • The consequence of water system closure and reduced water consumption in Paper Mills is increased white-water conductivity associated with increased total dissolved solids. This leads to difficulties man-aging the wet end chemistry of paper machines, mainly due to stearic hindrance effects on wet end chemical additives. This in turn causes poor productivity and Inefficient chemicals usage. The success of a number of projects is reported. The application and development of new multi-component micro-particle systems which can further assist in achieving a significant degree of system closure or Zero Effluent is described.

  • PDF

투습성에 따른 단열재의 단열성능평가 및 고찰 (The estimation on the insulation performance of thermal insulation materials according to water vapor permeance)

  • 김석현;박종일;이민우;홍진관
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2006년도 하계학술발표대회 논문집
    • /
    • pp.1012-1018
    • /
    • 2006
  • In this study, the insulation performance of thermal insulation materials such as glass wool, polyetylene and flexible lastomeric foam according to water vapor permeance was estimated by using experimental correlation equation. The results showed the conductivity increment of flexible lastomeric foam which has very low-permeability (${\le}0.15[ng/{\cdot}s{\cdot}Pa]\;or\;{\mu}{\ge}1,000$) is about 50% lower than that of glass wool with the lapse of ten years. The conclusion is that moisture inevitably accumulated in permeable Insulations reduces insulation performance and also accelerates surface condensation in the case of cold water system.

  • PDF

도계폐기물의 열가수분해 반응에 따른 열전달 특성 연구 (A Study on Heat Transfer Characteristics according to Thermal Hydrolysis Reaction of Poultry Slaughter Waste)

  • 송형운;정희숙;김충곤
    • 유기물자원화
    • /
    • 제23권4호
    • /
    • pp.95-103
    • /
    • 2015
  • 본 연구에서 목적은 열가수분해 반응기에 최적설계를 위해 반응온도에 따른 도계폐기물의 열전도도를 정량하는 것이다. 이에 반응온도에 따른 탈수슬러지의 열전도도를 연속적으로 정량한 결과, 반응온도가 증가할수록 열가수분해 반응에 의한 고온, 고압에 의해 슬러지가 열적으로 가용화된다. 따라서, 슬러지 세포내에 결합수가 자유수로 용출되어 고상의 탈수슬러지가 액상의 슬러리로 상태가 변화된다. 그 결과 반응초기인 반응온도 $20^{\circ}C$에서 도계슬러지에 열전도도가 물에 비해 2.11배정도 낮지만 $200^{\circ}C$에서는 도계슬러지의 열전도도가 $0.677W/m{\cdot}^{\circ}C$로 물과 유사하다. 따라서 열가수분해에 의한 슬러지의 물리적 특성변화는 열전달 효율에 매우 중요한 인자임을 확인하였고, 열가수분해반응기 최적 설계를 위한 경계조건으로 실험 측정값과 일치도가 99.69%인 반응온도에 따른 열전도도 함수를 도출하였다.

흙-벤토나이트 혼합 차수재의 품질관리 사례연구 (A Case Study on the Quality Control of Soil-Bentonite Admixed Liner)

  • 정하익;이용수;홍승서;정길수;이회준
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 1999년도 봄 학술발표회 논문집
    • /
    • pp.497-504
    • /
    • 1999
  • This study presents the physical and engineering characteristics of soil-bentonite admixed liner in I landfill. Main focus was the hydraulic conductivity of compacted soil-bentonite admixed and mechanisms governing low permeable properties of the admixed liner. Laboratory and field tests such as compaction, hydraulic conductivity, density, water content for the soil-bentonite admixed liner were carried out. Quality control criteria for the best construction of the soil-bentonite admixed liner was suggested through laboratory and field test results.

  • PDF

Polyaniline계 전도성 고분자의 열안정 특성 (Thermal stability of polyaniline based conductive polymer blend)

  • 백운석;윤호규;서광석
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1998년도 추계학술대회 논문집
    • /
    • pp.215-218
    • /
    • 1998
  • The thermal stability of polyaniline-camphorsulfonic acid(PANI-CSA) film was studied as a function of temperature and time. A decrease in electrical conductivity of PANI-CSA film occurred when PANI-CSA film is subjected to temperature above 60$^{\circ}C$. From the result of thermogravimetry (TG), it was thought that the deterioration in electrical conductivity of PANI-CSA film was due to evaporation of water and residual solvent.

  • PDF

로그분포모형을 이용한 토양입도분포로부터의 불포화수리전도도 추정

  • 황상일
    • 한국지하수토양환경학회:학술대회논문집
    • /
    • 한국지하수토양환경학회 2003년도 추계학술발표회
    • /
    • pp.99-101
    • /
    • 2003
  • Unsaturated hydraulic conductivity models have been widely used for the numerical modeling of water flow and contaminant transport in soils. In this study, a simple hydraulic conductivity model is developed by using information of particle-size distribution from the lognormal distribution model and its results are compared with those from the Kosugi-Mualem (KM) model. The accuracy of the proposed model is verified for observed data chosen from the international UNSODA database. Results showed that the proposed model produces adequate predictions of hydraulic conductivities. Performance of this model is generally better than the KM function.

  • PDF

콘크리트의 열전도율에 관한 실험적 연구 (Experiments on Thermal Conductivity of Concrete)

  • 김진근;전상은;양은익;김국한;조명석;방기성
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1998년도 가을 학술발표대회 논문집(III)
    • /
    • pp.946-951
    • /
    • 1998
  • In order to calculate the thermal stresses of massive concrete structures in non-steady state conditions the thermal properties of the materials have to be well known. Structural materials such as concrete, rock and soil are heterogeneous, damp and porous so that measurements of their thermal properties by conventional methods would result in large errors. In this study, thermal conductivity was measured by the device, QTM-D3 which is usually used in Japan. Variables are chosen as age, water content, temperature, aggregate content, S/A ratio and type of cementitious materials. Finally a model for thermal conductivity was proposed.

  • PDF

물환경 체험 및 탐구 활동에서 수질오염지표로서 전기전도도(EC) 혹은 총용존고형물질(TDS)의 활용에 대한 고찰 (EC or TDS as a Water Pollution Criteria in Water Education Program)

  • 안삼영
    • 한국환경과학회지
    • /
    • 제31권4호
    • /
    • pp.341-356
    • /
    • 2022
  • Electrical Conductivity (EC) or Total Dissolved Solids (TDS) has been often used to evaluate the water quality in some water education program for children and youth. This study attempted to find out whether EC (or TDS) can be used as a water pollution criteria in water education program. To clarify it, we used the water analysis data of July 2019 and January 2020 from Water Environment Information System. Data from 332 points in Han-river were used to investigate correlation between the parameters, such as BOD, COD, TN, TP vs EC. Correlation(r) for all data of BOD vs. EC was 0.347 for July 2019 and 0.483 for January 2020. No correlation was observed for BOD Ia and BOD Ib for July 2019 (r=-0.041, -0.030, respectively) and BOD Ia for January 2020 (r=0.041). Better correlation for all data of COD vs. EC was obtained (r=0.543 for July 2019 and r=0.610 for January 2020). However, no correlation was observed for COD Ia for January 2020. High vlaue of EC or TDS does not always mean water pollution, especially for clean water environment. Thus, EC (or TDS) alone can not be used as a water pollution criteria.