• 제목/요약/키워드: Water circulation system

검색결과 472건 처리시간 0.026초

원자로 차폐체 자연순환냉각에 관한 연구 (HWR Shield Cooling Natural Circulation Study)

  • 신정철
    • 에너지공학
    • /
    • 제21권3호
    • /
    • pp.221-227
    • /
    • 2012
  • The CANDU 9 shield cooling system was designed and layout with the objective of promoting natural circulation on loss of forced flow. In the present study, the shield cooling natural circulation was analyzed using verified the thermal-hydraulic code when the coolant pump or the heat exchanger was lost. This study showed that thermosyphoning cooled the end shields and prevented the end shields and the reserve water tank from boiling for at least 8 hours on loss of the shield cooling pumps but the heat exchangers still operational. With the loss of both pumps and heat exchangers, the end shields remain subcooled for up to 4 hours. To enhance thermosyphoning, the bypass connection to the line from the reserve water tank should be relocated to a point as low as possible.

물의 순환 시스템 장치 개발 및 수업 프로그램 효과 분석 (Analysis of the Effectiveness on Instructional Program by Water Circulation System Device)

  • 강정수;김형범
    • 대한지구과학교육학회지
    • /
    • 제11권1호
    • /
    • pp.21-37
    • /
    • 2018
  • 이 연구의 목적은 과학 행동 체계를 통해 초등학생들이 물의 순환 개념을 쉽게 이해할 수 있도록 시각화하는 것이다. 일반적으로 초등학생들이 물의 순환 개념을 이해하기란 쉽지 않으며, 대부분의 초등학생들은 구름이 더 무겁기 때문에 비가 내리는 것의 과학적 개념이 아닌 오개념을 가지고 있다. 또한 현행 교과서의 실험들은 연결성이 낮고 물의 순환 개념들이 세분화되어 올바른 과학적 개념을 형성하는데 어려움을 줄 가능성이 비교적 높다. 따라서 이 연구에서는 교과서 내 이슬, 안개 및 구름 등의 실험들을 통합하여 물의 순환 개념에 대한 시스템적 사고가 가능하도록 물의 순환 시스템 장치와 이를 활용한 교수 학습 프로그램을 개발하였다. 또한 준실험 설계를 통해 물의 순환 시스템 장치를 활용한 수업 프로그램의 효과성을 알아보았다. 그 결과, 물의 순환 시스템 장치를 활용한 수업은 증발, 응결, 그리고 물 순환의 개념을 시스템적으로 이해하는데 이전의 실험들보다 더 효과적이라는 것을 보여 주었다. 또한 물의 순환 시스템 장치를 활용한 수업에서 가장 효과적인 실험 조건과 최적의 실험변수인 응결량의 매개변수를 분석할 수 있었다.

단순화된 피동 원자로건물 냉각계통 내 자연순환에 관한 수치적 연구 (Numerical Investigation on Natural Circulation in a Simplified Passive Containment Cooling System)

  • 서정수
    • 한국안전학회지
    • /
    • 제33권3호
    • /
    • pp.92-98
    • /
    • 2018
  • The flow of cooling water in a passive containment cooling system (PCCS), used to remove heat released in design basis accidents from a concrete containment of light water nuclear power plant, was conducted in order to investigate the thermo-fluid equilibrium among many parallel tubes of PCCS. Numerical simulations of the subcooled boiling flow within a coolant loop of a PCCS, which will be installed in innovative pressurized-water reactor (PWR), were conducted using the commercially available computational fluid dynamics (CFD) software ANSYS-CFX. Shear stress transport (SST) and the RPI model were used for turbulence closure and subcooled flow boiling, respectively. As the first step, the simplified geometry of PCCS with 36 tubes was modeled in order to reduce computational resource. Even and uneven thermal loading conditions were applied at the outer walls of parallel tubes for the simulation of the coolant flow in the PCCS at the initial phase of accident. It was observed that the natural circulation maintained in single-phase for all even and uneven thermal loading cases. For uneven thermal loading cases, coolant velocity in each tube were increased according to the applied heat flux. However, the flows were mixed well in the header and natural circulation of the whole cooling loop was not affected by uneven thermal loading significantly.

자연순환식 태양열 급탕 시스템의 성능 추정 방법에 관한 연구 (A Study on the System Performance Prediction Method of Natural Circulation Solar Hot Water System)

  • 윤석범;전문헌
    • 태양에너지
    • /
    • 제7권2호
    • /
    • pp.37-53
    • /
    • 1987
  • This study has been prepared for the purpose of developing the system performance prediction method of natural circulation solar hot water system. The storage tank of the natural circulation solar hot water system equipped with flat-plate solar collector is located at higher elevation than the solar collectors. Therefor, the storage tank temperature distribution formed accordance with configuration of storage tank by flow rate of circulating fluid affect system collection efficiency. In this study measure the storage tank temperature distribution with various experimental system under real sun condition and present the theoretical prediction method of the storage tank temperature. Moreover measure the flow rate not only day-time but also night-time reverse flow rate with die injection visual flow meter. Main conclusion obtain from the present study is as follows; 1) The storage tank temperature distribution above the connecting pipe connection position is the same as that of the fully mixed tank and below the connection position is the same as that of stratified tank. 2) The system performance sensitive to the storage tank temperature distribution. Therefore detailed tank model is necessary. Average storage tank temperature can be calculate 3% and storage tank temperature profile can get less than 10% difference with this model system.

  • PDF

하나로 유동모의 설비의 유체순환계통 해석 (The Analysis of Flow Circulation System for HANARO Flow Simulated Test Facility)

  • 박용철
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2002년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.419-424
    • /
    • 2002
  • The HANARO, a multi-purpose research reactor of 30 MWth open-tank-in-pool type, has been under normal operation since its initial criticality In February, 1995. Many experiments should be safely performed to activate the utilization of the HANARO. A flow simulation facility is being developed for the endurance test of reactivity control units for extended life times and the verification of structural integrity of those experimental facilities prior to loading in the HANARO. This test facility is composed of three major parts; a half-core structure assembly, flow circulation system and support system. The flow circulation system is composed of a circulation pump, a core flow pipe, a core bypass flow pipe and instruments. The system is to be filled with de-mineralized water and the flow should be met the design flow to simulate similar flow characteristics in the core channel of the half-core test facility to the HANARO. This paper, therefore, describes an analytical analysis to study the flow behavior of the system. The computational flow analysis has been performed for the verification of system pressure variation through the three-dimensional analysis program with standard k-$\epsilon$ turbulence model and for the verification of the structural piping integrity through the finite element method. The results of the analysis are satisfied the design requirements and structural piping integrity of flow circulation system.

  • PDF

하나로 유동 모의 설비의 유체순환계통 해석 (The Analysis for Flow Circulation System in HANARO Flow Simulation Facility)

  • 박용철
    • 한국유체기계학회 논문집
    • /
    • 제7권1호
    • /
    • pp.30-35
    • /
    • 2004
  • The HANARO, a multi-purpose research reactor of 30 MWth open-tank-in-pool type, has been under normal operation since its initial criticality in February, 1995. Many experiments should be safely performed to activate the utilization of the HANARO. HANARO flow simulation facility is being developed for the endurance test of reactivity control units for extended life time and the verification of structural integrity of those experimental equipments prior to loading in the HANARO. This facility is composed of three major parts; a half-core structure assembly, a flow circulation system and a support system. The flow circulation system is composed of a circulation pump, a core flow piping, a core bypass flow piping and instruments. The system is to be filled with de-mineralized water and the flow should be met the design requirements to simulate a similar flow characteristics in the core channel of the half-core structure assembly to the HANARO. This paper, therefore, presents an analytical analysis to study the flow behavior of the system. Computational flow analysis has been performed for the verification of system pressure variation through the three-dimensional analysis program with the standard $k-{\epsilon}$ turbulence model and for the verification of the structural piping integrity through the finite element method. According to the analysis results, it could be said that the design requirements and the structural piping integrity of the flow circulation system are satisfied.

Three-dimensional Numerical Modelling of Seawater Circulation of Semi-enclosed Bay with the Flow-control Structures

  • JONG-KYU KIM;TAE-SOON KANG;HEON-TAE KIM
    • 한국해양공학회지
    • /
    • 제15권3호
    • /
    • pp.35-42
    • /
    • 2001
  • The characteristics of tidal circulation with the flow-control structures using the three-dimensional numerical model (POM, Princeton Ocean Model) of Chinhae Bay, Korea were investigated. To confirm th efficiencies of flow-control structures, the training wall and submerged training wall were constructed at the mouth and narrow channel in Chinhae Bay. On the basis of the present investigation, the tidal circulation induced by the construction of flow-control structures could enhance the water exchange improvement appropriately. And, th training wall at the central is more dominated than the other structures for the efficient of water exchange. The sites and types of structure and flow patterns seem to be very sensitive in tidal simulation and changes in flow fields.

  • PDF

타워형 태양열 발전 흡수기의 열유속에 따른 수순환 특성 연구 (Water Circulation Characteristics of a Water/Steam Receiver for Solar Power Tower System at Various Heat Fluxes)

  • 서호영;김종규;강용혁;김용찬
    • 한국태양에너지학회 논문집
    • /
    • 제28권2호
    • /
    • pp.1-9
    • /
    • 2008
  • This paper describes water circulation characteristics of a water/steam receiver at various heat fluxes. The water/steam receiver for a solar tower power system is a natural circulation type. Experimental conditions of water and steam were set at a pressure of 5 bar and temperature of $151.8^{\circ}C$. The experimental device for the water/steam receiver consisted of a steam drum, upper/lower header, riser tubes, and downcomer tube. The experiments were conducted by varying heat fluxes in terms of mass flow rate in each riser tube. However, the total mass flow rate on the riser tubes was fixed at 217.4 g/s. For the uniform heat flux, while the water temperature of the steam drum and upper header were kept at steady state, the temperature of the lower header was fluctuated. For the non-uniform heat flux, while the temperature of the steam drum was kept steady state, the temperature difference increased in the right and left side of the upper header, and the temperature of the lower header was fluctuated.

Validation of Ocean General Circulation Model (FMS-MOM4) in Relation with Climatological and Argo Data

  • Chang, You-Soon;Cho, Chang-Woo;Youn, Yong-Hoon;Seo, Jang-Won
    • 한국지구과학회지
    • /
    • 제28권5호
    • /
    • pp.545-555
    • /
    • 2007
  • Ocean general circulation model developed by GFDL on the basis of MOM4 of FMS are examined and evaluated in order to elucidate the global ocean status. The model employs a tripolar grid system to resolve the Arctic Ocean without polar filtering. The meridional resolution gradually increases from $1/3^{\circ}$ at the equator to $1^{\circ}$ at $30^{\circ}N(S)$. Other horizontal grids have the constant $1^{\circ}$ and vertical grids with 50 levels. The ocean is also coupled to the GFDL sea ice model. It considers tidal effects along with fresh water and chlorophyll concentration. This model is integrated for a 100 year duration with 96 cpu forced by German OMIP and CORE dataset. Levitus, WOA01 climatology, serial CTD observations, WOCE and Argo data are all used for model validation. General features of the world ocean circulation are well simulated except for the western boundary and coastal region where strong advection or fresh water flux are dominant. However, we can find that information concerning chlorophyll and sea ice, newly applied to MOM4 as surface boundary condition, can be used to reduce a model bias near the equatorial and North Pacific ocean.

자연순환형 태양열온수기 동파방지기술 (Freeze Protection for Passive Solar Water Heating System)

  • 김종현;홍희기;정재동
    • 설비공학논문집
    • /
    • 제23권5호
    • /
    • pp.327-333
    • /
    • 2011
  • In the present work, a new freeze protection method has been proposed for a natural circulation system of solar water heater. Though electrothermal wire is popularly used for the purpose, there are freezing troubles by wire cut-off and shortage of excessive electric power consumption. In the experimental device, hot water in storage tank was used to heat the outlet pipe from the tank if the pipe surface temperature falls lower than a set point. The cold water pipe to the storage tank was installed to directly contact the hot water pipe surface temperature rose by transferred heat.