• Title/Summary/Keyword: Water charge

Search Result 656, Processing Time 0.029 seconds

Influence of Refrigerant Charge Amount on the Performance of a Water-to-Water Type Ground Source Heat Pump with a Variation of Compressor Speed and Water Flow Rate (용량 가변 및 유량변화에 따른 지열원 물대물 열펌프 유닛의 충전량 변화에 따른 성능 특성)

  • Cho, Chan-Yong;Choi, Jong-Min
    • New & Renewable Energy
    • /
    • v.7 no.4
    • /
    • pp.30-36
    • /
    • 2011
  • The objective of this study is to investigate the effects of the refrigerant charge amount on the performance of a water-to-water ground source heat pump with a variation of compressor speed and the secondary fluid flow rate. The water-to-water ground source heat pump was tested by varying refrigerant charge amount from -40% to 20% of full charge. Compressor speed was changed from 30 Hz to 75 Hz and the secondary fluid flow rate was adjusted from 6 LPM to 14 LPM. For all test conditions, EWTs of an indoor heat exchanger and an outdoor heat exchanger were maintained at standard conditions of ISO 13256-2. The slope of the COP with the variation of charge amount is much steeper at undercharged conditions than that at overcharged conditions. For all compressor speed, the variation of the system performance according to charge amounts showed the similar trends. However, the optimum charge amount of the system increased a little with an increment of compressor speed. When the secondary fluid flow rate decreased, the system was optimized at higher refrigerant charge amount conditions.

Influence of Refrigerant Charge Amount on the Performance of a Water-to-Water Heat Pump with a Variation of Compressor Speed and Water Flow Rate (압축기 용량 및 유량변화에 따른 물대물 열펌프 유닛의 충전량 변화에 따른 성능 특성)

  • Cho, Chanyong;Choi, Jong Min
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2011.11a
    • /
    • pp.143.1-143.1
    • /
    • 2011
  • The objective of this study is to investigate the effects of the refrigerant charge amount on the performance of a water-to-water ground source heat pump with a variation of compressor speed and the secondary fluid flow rate. The water-to-water ground source heat pump was tested by varying refrigerant charge amount from -40% to 20% of full charge. Compressor speed was changed from 30 Hz to 75 Hz, and the secondary fluid flow rate was adjusted from 6 LPM to 14 LPM. For all test conditions, EWT of an indoor heat exchanger and an outdoor heat exchanger were maintained at standard conditions of ISO 13256-2. The slope of the COP with the variation of charge amount is much steeper at undercharged conditions than that at overcharged conditions. For all compressor speed, the variation of the system performance according to charge amounts showed the similar trends. However, the optimum charge amount of the system increased a little with an increment of compressor speed. When the secondary fluid flow rate decreased, the system optimized at higher refrigerant charge amount conditions.

  • PDF

Space Charge Phenomena in Polyimide Films and Effects of Absorbed Water (폴리이미드 박막의 공간전하현상 및 수분의 영향)

  • Yun, Ju-Ho;Choi, Yong-Sung;Hwang, Jong-Sun;Lee, Kyung-Sup
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.04c
    • /
    • pp.82-85
    • /
    • 2008
  • Polyimide is widely used as a high-temperature insulating material. Space charge distributions in polyimide (PI) films strongly depend upon electric field, temperature, water content and so on. We observed space charge distributions in PI films with various water contents. When a dc field was applied to as-received PI films or water-treated PI films, positive and negative homo space charges were observed near the respective electrodes at 333 K. In dried PI films, the homo space charges were much reduced, and positive and negative hetero space charges in the bulk were clearly observed. The space charge amounts in water-treated PI films were smaller than in as-received ones, while the current density in water-treated PI film was larger than that in as-received one by two or more orders of magnitude. These suggest not only that the charge injection from the electrode is enhanced by absorbed water but also that absorbed water makes carriers mobile. The decay of space charge was also faster in water-treated PI than in as-received or dried one. This also supports the enhancement of apparent mobilities of carriers in PI by absorbed water.

  • PDF

Space Charge Phenomena in Polyimide Films (폴리이미드 박막의 공간전하현상)

  • Yun, Ju-Ho;Choi, Yong-Sung;Lee, Kyung-Sup
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2007.11a
    • /
    • pp.311-312
    • /
    • 2007
  • Polyimide is widely used as a high-temperature insulating material. Space charge distributions in polyimide (PI) films strongly depend upon electric field, temperature, water content and so on. We observed space charge distributions in PI films with various water contents. When a dc field was applied to as-received PI films or water-treated PI films, positive and negative homo space charges were observed near the respective electrodes at 333 K. In dried PI films, the homo space charges were much reduced, and positive and negative hetero space charges in the bulk were clearly observed. The space charge amounts in water-treated PI films were smaller than in as-received ones, while the current density in water-treated PI film was larger than that in as-received one by two or more orders of magnitude. These suggest not only that the charge injection from the electrode is enhanced by absorbed water but also that absorbed water makes carriers mobile. The decay of space charge was also faster in water-treated PI than in as-received or dried one. This also supports the enhancement of apparent mobilities of carriers in PI by absorbed water.

  • PDF

Water Absorption and Charge Formation in PCB (PCB 절연체에서 전하 형성과 수분 흡수)

  • Lee, Jung-Soo;Hwang, Jong-Sun
    • Proceedings of the KIEE Conference
    • /
    • 2008.09a
    • /
    • pp.233-234
    • /
    • 2008
  • We observed internal space charge behavior for two types of epoxy composites under dc electric fields to investigate the influence of water at high temperature. In the case of glass/epoxy specimen, homocharge is observed at water-treated specimen, and spatial oscillations become clearer in the water-treated specimens. Electric field in the vicinity of the electrodes shows the injection of homocharge. In aramid/epoxy specimens, heterocharge is observed at water-treated specimens, i.e. negative charge accumulates near the anode, while positive charge accumulates near the cathode. Electric field is enhanced just before each electrode. In order to further examine the mechanism of space charge formation, we have developed a new system that allows in situ space charge observation during ion migration tests at high temperature and high humidity. Using this in situ system.

  • PDF

Influence of Water Absorption and Charge Formation in PCB (PCB 절연체에서 전하 형성과 수분 흡수의 영향)

  • Goo, Jung-Hyun;Choi, Yong-Sung;Lee, Kyung-Sup
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.2307-2308
    • /
    • 2008
  • We observed internal space charge behavior for two types of epoxy composites under dc electric fields to investigate the influence of water at high temperature. In the case of glass/epoxy specimen, homocharge is observed at water-treated specimen, and spatial oscillations become clearer in the water-treated specimens. Electric field in the vicinity of the electrodes shows the injection of homocharge. In aramid/epoxy specimens, heterocharge is observed at water-treated specimens, i.e. negative charge accumulates near the anode, while positive charge accumulates near the cathode. Electric field is enhanced just before each electrode. In order to further examine the mechanism of space charge formation, we have developed a new system that allows in situ space charge observation during ion migration tests at high temperature and high humidity. Using this in situ system.

  • PDF

Evaluation of Streaming Current Detector (SCD) and Charge Analyzing System (CAS) for automation of coagulant dosage determination (낙동강 하류 원수의 응집제 주입 자동화를 위한 Streaming Current Detector (SCD)와 Charge Analyzing System (CAS)의 평가)

  • Kim, Sang-Goo;Son, Hee-Jong;Lee, Jeong-Kyu;Yeom, Hoon-Sik;Yoo, Pyung-Jong
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.39 no.4
    • /
    • pp.201-207
    • /
    • 2017
  • This study was conducted to investigate the characteristics of the stream current detector (SCD) and charge analyzing system (CAS), which are well known as the automatic coagulant dosage determination instruments. When the SCD system was used, the current charge value set at pH 9.3 could not be used as the coagulant dosage when the pH of the raw water decreased to 5.7, and the current charge value corresponding to pH 5.7 was required to be reset. In case of CAS system, polydadmac is stable as a cationic titrant when the pH of the raw water ranged 9.3 to 6.0. And it was effective to use polydadmac as a cationic titrant for high turbidity water. The current charge of polydadmac was almost constant between pH 5 and 11, however, the difference in charge of alum is six times in this pH range. Therefore, when the pH of the raw water was changed, it seems that the coagulant used in the actual water treatment plant was as a good cationic titrant.

A Research Trend on High Density Polyethylene Electrical Strength (폴리이미드 박막의 공간전하현상에 관한 연구 동향)

  • Choi, Keun-Ho;Oh, Chang-Keun;Shin, Hyun-Man;Hwang, Jong-Sun;Choi, Yong-Sung;Lee, Kyung-Sup
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.1984-1985
    • /
    • 2007
  • Polyimide is widely used as a high-temperature insulating material. Space charge distributions in polyimide (PI) films strongly depend upon electric field, temperature, water content and so on. We observed space charge distributions in PI films with various water contents. When a dc field was applied to as-received PI films or water-treated PI films, positive and negative homo space charges were observed near the respective electrodes at 333 K. In dried PI films, the homo space charges were much reduced, and positive and negative hetero space charges in the bulk were clearly observed. The space charge amounts in water-treated PI films were smaller than in as-received ones, while the current density in water-treated PI film was larger than that in as-received one by two or more orders of magnitude. These suggest not only that the charge injection from the electrode is enhanced by absorbed water but also that absorbed water makes carriers mobile. The decay of space charge was also faster in water-treated PI than in as-received or dried one. This also supports the enhancement of apparent mobilities of carriers in PI by absorbed water.

  • PDF

The Effect of Industrial Waste Water Effluent Charge Reform (수질배출부과금제도 개선 방안 연구)

  • Min, DongKi
    • Environmental and Resource Economics Review
    • /
    • v.18 no.4
    • /
    • pp.767-785
    • /
    • 2009
  • This paper studies the effect of industrial waste water effluent charge reform. The goal of the present effluent charge system is to use environmental resources in an efficient way by charging the cost for removing emitted water pollutants. However, the present system is a type of regulation instead of providing economic incentives to the industry. That is, if a firm emits pollutants greater than the limit, it has to pay an amount greater than the cost of cleaning them taking into account the amount of waste water discharged, region, the number of violation and the level of density of pollutants. However, the excessive fees have resulted in the lowest ratio of revenue-to-effluent charge among all environmental charges. The paper estimates the effect of the change in effluent fee and revenue when the present effluent charge system is converted to one that offers economic incentives. The results show that the amount of waste water effluent charge is about four times larger than the estimated environmental cleaning cost. In addition, the results show that by modifying the effluent charge system, the ratio of revenue to effluent charge can be raised.

  • PDF

Behavior of Residual Charges in Water-tree Degraded XLPE Sheets and Cable

  • Ebinuma, Yasumitsu;Masui, Noriaki
    • Transactions on Electrical and Electronic Materials
    • /
    • v.7 no.5
    • /
    • pp.224-229
    • /
    • 2006
  • Many studies have been done on the application of residual charge measurement in cable degradation diagnosis. In this paper, the behavior of residual charges measured with water-tree degraded XLPE sheets and cable are discussed. At charge injection process, the charge is injected by applying dc voltage as a conventional method, suddenly cut-off ac voltage or impulse voltage. Therefore the residual charge is influenced by the applying process. At charge release process, transient dc current flows when applying ac high voltage and also ac high voltage superimposed to dc low voltage. From the results, new diagnosis method is suggested.