• 제목/요약/키워드: Water boundary layer

검색결과 226건 처리시간 0.021초

채널 형상에 따른 마이크로채널 판형 열교환기 열전달 성능 향상에 관한 수치 연구 (Numerical Study of Heat Transfer Enhancement on Microchannel Plate Heat Exchanger with Channel Shape)

  • 전승원;김윤호;이규정
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2007년도 춘계학술대회B
    • /
    • pp.1888-1893
    • /
    • 2007
  • In this study, the microchannel plated heat exchanger were numerically studied for the enhancement of heat transfer in the channel configuration. Unit cold and hot fluid region with the microchannel were modeled and periodic boundary condition at the side wall was applied to continuously repeating geometry. The material of micro-structured plate is STS304 and working fluid is water. Triangular obstacles were placed in micro channel to enhance heat transfer. The performance of microchannel plated heat exchangers were numerically investigated with various obstacle configuration and Reynolds number under the parallel and counter flows. Heat transfer rate has increased about 18% compared with straight channel, but pressure drop also increased about 3.5 times. The main factor of increasing of pressure drop and heat transfer rate is considered that the momentum was lost to collide against obstacles, generation of secondary flow and boundary layer separation, wake and vortex forming phenomena.

  • PDF

Effect of Temperature and Plow Pan on Water Movement in Monolithic Weighable Lysimeter with Paddy Sandy Loam Soil during Winter Season

  • Seo, Mijin;Han, Kyunghwa;Jung, Kangho;Cho, Heerae;Zhang, Yongseon;Choi, Seyeong
    • 한국토양비료학회지
    • /
    • 제49권4호
    • /
    • pp.300-309
    • /
    • 2016
  • The monolithic weighing lysimeter is a useful facility that could directly measure water movement via layers, drainage, and evapotranspiration (ET) with precise sensors. We evaluated water movement through layers and water balance using the lysimeter with undisturbed paddy sandy loam soil, Gangseo soil series (mesic family of Anthraquic Eutrudepts classified by Soil Taxonomy) during winter season from Dec. 2014 to Feb. 2015. Daily ET indicated up to 1.5 mm in December and January and 2 mm in February. The abrupt increase of soil water tension at the depth of 0.1 m, when soil temperature at the same depth was below $2^{\circ}C$, was observed due to temporary frost heaving. The surface evaporation was less than reference ET below -15 kPa of soil water potential at the depth of 0.1 m. The maximum drainage rate was similar to the saturated hydraulic conductivity of a plow pan layer. Both upward and downward water movement, related to ET and drainage, were retarded by a plow pan layer. This study demonstrated that the lysimeter study could well quantify water balance components even under frost heaving during winter season and that a plow pan with low permeability could act as a boundary that affects drainage and evapotranspiration.

Water transport through hydrophobic micro/nanoporous filtration membranes on different scales

  • Mian, Wang;Yongbin, Zhang
    • Membrane and Water Treatment
    • /
    • 제13권6호
    • /
    • pp.313-320
    • /
    • 2022
  • Theoretical calculation results are presented for the enhancement of the water mass flow rate through the hydrophobic micro/nano pores in the membrane respectively on the micrometer and nanometer scales. The water-pore wall interfacial slippage is considered. When the pore diameter is critically low (less than 1.82nm), the water flow in the nanopore is non-continuum and described by the nanoscale flow equation; Otherwise, the water flow is essentially multiscale consisting of both the adsorbed boundary layer flow and the intermediate continuum water flow, and it is described by the multiscale flow equation. For no wall slippage, the calculated water flow rate through the pore is very close to the classical hydrodynamic theory calculation if the pore diameter (d) is larger than 1.0nm, however it is considerably smaller than the conventional calculation if d is less than 1.0nm because of the non-continuum effect of the water film. When the driving power loss on the pore is larger than the critical value, the wall slippage occurs, and it results in the different scales of the enhancement of the water flow rate through the pore which are strongly dependent on both the pore diameter and the driving power loss on the pore. Both the pressure drop and the critical power loss on the pore for starting the wall slippage are also strongly dependent on the pore diameter.

콴다효과를 응용한 플랩이 달린 고양력 날개장치에 대한 실험적 연구 (An Experimental Study of Coanda Effect on the Flapped Control Surfaces)

  • 안해성;김효철
    • 대한조선학회논문집
    • /
    • 제40권5호
    • /
    • pp.10-16
    • /
    • 2003
  • To investigate the jet effect on circulation control, a segment of model was prepared and inserted horizontally across the test section of the cavitation tunnel. The hydrodynamic forces acting on the model were measured under the 2 dimensional flow behavior. Circulation flow control requires higher flow rate of water jet than boundary layer control does. Jet injection is effective in increasing lift coefficient and the increments reach to 160% in a certain combination of parameters such as an angle of attack, jet flow rate and flap angle. The blown water jet not only reduces form drag but also thrust effect, which is sometimes greater than the form drag in specific conditions.

해양에서의 수평적 수온변화가 음파전달에 미치는 영향에 대한 기초적 연구 (A Basic Study for the Propagation Characteristics Due to the Horizontal Water Temperature Variations in the Sea)

  • 하강열;김무준
    • 수산해양기술연구
    • /
    • 제32권4호
    • /
    • pp.395-401
    • /
    • 1996
  • In this paper, the propagation characteristics due to the horizontal water temperature variations in the sea such as thermal fronts is analyzed by the ray theory. Two models for the temperature anomaly layer are chosen. One is a plane type and the other is a cylindrical type. In the plane type, the temperature increases linearly from a isothermal region to 5km with the gradient of about $2^{\circ}C.$/km, and decreases with the same gradient in next 5km. In the cylindrical type, water temperature increases only with the same gradient from a half cylindrical thermal boundary surface. The result showed that the gradient of acoustic rays decreases in the temperature increasing region and vice versa in temperature decreasing region. And, the transmission loss due to the temperature variation was less than O.2dB in the plane type model as well as in the cylindrical one.

  • PDF

관내 유동 플라스틱 슬러리의 열전달 특성 (Heat Transfer Characteristics of Plastic Particle Slurry in a Circular tube Flow)

  • 김명환;김명준
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제28권3호
    • /
    • pp.451-456
    • /
    • 2004
  • This present experimental study has dealt with the heat transfer characteristics of plastic particle slurry which flows in a circular tube. This type of slurry is suggested for heat transfer enhancement effect cause by random and vortex effect of plastic particle dispersed in water. As a result, the thermal boundary layer becomes thin so the heat transfer coefficient on the tube wall more increase compare to pure water flow. This experimental test section was composed with stainless pipe which has the length of 2000mm, inner pipe diameter of 14mm and outer pipe diameter of 60mm. The most effective and important parameter of this experiment is plastic packing factor(PPF). The focuses of these results are pressure drop and heat transfer coefficient. As results, the friction factor of plastic particle slurry becomes higher at laminar flow region than pure water because of buoyancy effect of plastic particle but the local heat transfer coefficient becomes higher.

분자운동력학법에 의한 분자괴의 표면현상 (Surface Phenomena of Molecular Clusters by Molecular Dynamics Method)

  • Maruyama, Shigeo;Matsumoto, Sohei;Ogita, Akihiro
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제20권3호
    • /
    • pp.11-18
    • /
    • 1996
  • Liquid droplets of water and argon surrounded by their vapor have been simulated by the milecular dynamics method. To explore the surface phenomena of clusters, each molecule is classified into 'liquid', 'surface', or 'vapor' with respect to the number of neighbor molecules. The contribution of a 'surface' molecule of the water cluster to the far infrared spectrum is almist the same as that of the 'liquid' molecule. Hence, the liquid-vapor interface is viewed as geometrically and temporally varying boundary of 'liquid' molecules with only a single layer of 'surface' molecules that might have different characteristics from the 'liquid' molecules. The time scale of the 'phase change' of each molecule is estimated for the argon cluster by observing the instantancous kinetic and potential energies of each molecule. To compare the feature of clusters with macroscopic droplets, the temperature dependence of the surface tension of the argon cluster is estimated.

  • PDF

염수로 충진된 낙동강 델타지역 피압대수층에서 담수주입에 의한 염수치환 연구 (Replacement of Saline Water through Injecting Fresh Water into a Confined Saline Aquifer at the Nakdong River Delta Area)

  • 원경식;정상용;이창섭;정재훈
    • 지질공학
    • /
    • 제25권2호
    • /
    • pp.215-225
    • /
    • 2015
  • 염수로 충진된 부산시 낙동강 델타지역에 염수오염을 방지하고 지하수자원을 확보할 수 있는 인공함양 실증시설의 구축을 목적으로, 고심도 피압대수층에 담수 주입시험을 실시하였다. 연구지역은 두꺼운(두께 10~21 m) 점토층이 가압층으로 분포하며, 두꺼운 하부모래층(두께 31.5~36.5 m)과 자갈층(두께 2.8~11 m)이 주대수층을 이루는 피압대수층을 형성하고 있다. 시험 전 실시한 전기전도도(EC) 검층결과 연구지역은 약 7~44 mS/cm의 EC 분포를 보이며, 15~38 m 사이에 담수와 염수의 전이대가 존재하였다. 수온은 5 m 심도까지는 10~15.5℃이었으나, 5 m 심도부터는 15.5℃에서 50 m 심도까지 17℃로 일정하게 증가하고 있었다. 담수 주입시험에서 총 62시간 동안 370 m3/day의 주입유량으로 약 950 m3의 담수가 주입되었으며, 주입공 OW-5의 40 m 심도에서 CTD Diver를 이용하여 담수체의 형성을 확인하였다. 주입 후 EC 및 온도 검층을 통해 주입된 담수체가 24시간 이상 유지되는 것을 확인하였고, 21일 경과 후 실시한 검층에서도 담수체의 존속이 확인되었다. 또한 OW-5공 주입시험보다 20일전에 실시된 1차 주입시험 주입공 OW-2에서도 아직 담수체의 영향이 남아있는 것으로 확인되었다. 그리고 OW-2와 5에 주입된 담수와 염수의 관계는 점이적이 아닌 뚜렷한 경계(Sharp Boundary)를 이루고 있었다. 따라서 주입된 담수가 염수 내에서 일정한 공간을 차지하며, 원상태의 수질을 상당기간 유지할 수 있다는 것을 파악하였다. 향후 인공함양 시설을 구축하여 장기적인 담수 주입을 통해 이 델타지역에 담수체를 형성시키는 실증연구를 수행한다면, 염수로 오염된 해안대수층을 대체수자원 확보의 공간으로 활용할 수 있을 것으로 사료된다.

PIV를 이용한 범포 주위의 유동장 특성 (The characteristics of the flow field around canvas kite using the PIV)

  • 배봉성;안희춘;배재현;박창두;김인옥
    • 수산해양기술연구
    • /
    • 제42권2호
    • /
    • pp.86-96
    • /
    • 2006
  • This research aims at establishing the fundamental characteristics of the kite through the analysis of the flow field around various types of kites. The approach of this study were adopted for the analysis; visualization by PIV(particle image velocimetry). Also, the lift and drag tests of kites had been performed in our previous finding(Bae et al., 2004a; Bae et al., 2004b). For this situation, models of canvas kite were deployed in the circulating water channel for the PIV test using the same conditions as in the lift and drag tests. The results obtained from the above approach are summarized as follows: Given the rectangular and triangular kites when attack angle is $20^{\circ}$, vortex by the boundary layer separation was seen in the leading edge and the flow towards the trailing edge was more turbulent. But, the inverted triangular type kite was seen to be stable without any boundary layer separation or turbulence. The increase of the attack angle resulted in the eddy in order of the rectangular, triangular and inverted triangular type. The magnitude of the eddy followed the same order. The effect of edge-eddy was biggest in the triangular type followed by the rectangular and then the inverted triangular type. The kite as the buoyancy device or the opening device will be very useful when the appropriate applications and the stability are met.

단열층 사용을 통한 성층 축열조 성능개선 (Performance Improvement of Stratified Thermal Storage Tank Using Heat Insulator)

  • 임세화;이태규;신승원
    • 대한기계학회논문집 C: 기술과 교육
    • /
    • 제2권1호
    • /
    • pp.65-72
    • /
    • 2014
  • 본 연구에서는 지역난방 공사에서 사용하고 있는 성층 축열조의 불가용 에너지를 줄이기 위해 단열층을 설계하였다. 단열층은 추가적인 장치 없이 고온수와 저온수의 밀도차이로 생기는 부력으로 운용된다. 축열조의 내부 온도분포를 모사할 수 있는 해석모델을 Matlab Simulink 를 이용하여 제작하고 해석 결과를 이용하여 단열층의 소재와 두께를 결정하였다. 또한 축열조의 축소실험을 통하여 단열층의 운용 가능성을 확인하였다. 실험 결과, 단열층이 축열 방열과정에서 고온수와 저온수의 혼합과 열전도로 인한 온도 경계층형성을 효과적으로 억제할 수 있다는 것을 확인하였다. 단열층을 설치한 축소실험에서는 단열층이 없는 축열조보다 약 1540 J 의 추가 가용에너지가 보존되었고 이를 실제 축열조에 적용할 경우 약 6%의 축열효율이 증가될 것으로 예상된다.