• Title/Summary/Keyword: Water area

Search Result 11,330, Processing Time 0.038 seconds

An Experimental Study on Scout Area around Groynes with Permeability and Install Angle (투과율과 설치각도에 대한 수제주변 세굴영역에 관한 실험 연구)

  • Yeo Hong-Koo;Kang Joon-Gu;Kim Sung-Jung;Rho Young-Sin
    • Journal of Korea Water Resources Association
    • /
    • v.39 no.7 s.168
    • /
    • pp.583-592
    • /
    • 2006
  • There has been debated on the fact that a scour hole produced by the construction of a groyne has environmental benefits such as provision of diverse underwater habitats and shelter for fish in the event of flooding. Therefore researches are focusing on the scour field around the groyne area beyond the existing safety issues. The scour area on aquatic habitats would format many form on groyne conditions so that the analysis of scour area is strongly required. This study conducted the experiments on permeability and installation angle of groyne and suggested the data for groyne selection in environmental point as analyzing scour area. The physical modeling was performed in different permeability (0%, 20%, 40%, 60%, 80%) and installation angle of groyne ($60^{\circ},\;90^{\circ},\;120^{\circ}$). As the result of the study, scour area and scour depth at maximum scour condition was revealed for each case and suggested the differences according to experiment conditions.

Characteristics of Wave Propagation by Water Level Conditions at Wando Sea Area: Numerical Modeling (완도 해역의 해수면 조건에 따른 파랑 변형 특성)

  • Jeon, Yong-Ho;Yoon, Han-Sam;Kim, Dong-Hwan;Kim, Won-Seok;Kim, Heon-Tae
    • Journal of Fisheries and Marine Sciences Education
    • /
    • v.25 no.1
    • /
    • pp.1-11
    • /
    • 2013
  • The aim of this study was estimated the characteristics of the wave propagation by the water level conditions using a numerical modeling method at the Wando sea area. For three cases numerical simulation on the condition of incident and incoming of the deepwater design wave and the season normal wave, the spatial distribution of the incident wave at study area were investigated. And the calculated numerical modeling results were compared with measured field wave data. According to on-site wave data measured for 18 days, the range of the significant wave height and period were 0.10~1.14 m, 4.35~8.74 sec, respectively, and the maximum wave height were 0.15~1.66 m. From the results of numerical model for offshore design wave incident, the wave height attacked from Southern-East direction at this study area were over maximum 10.5 m because of rapidly change of water depth. Numerical modeling by three water level conditions of Approxmate Lowest Low Water Level(Approx. L.L.W), Mean Sea Level(M.S.L) and Approximate Highest High Water Level(Approx. H.H.W) were practiced. From the results for the case of Approx. H.W.L, variations of wave height at the back area of islands were about 1.6 m at maximum value for the case of deepwater design wave incoming. The significant wave heights of winter season were bigger than summer under normal wave condition, the incident wave height over 5.5 m decreased by shielding effect of islands. The change of maximum wave height at summer season were distinct than winter and was about 1.2 m and 0.8 m, respectively.

The Analysis of Soil Erosion in Water-pollutant Buffering Zone of Imha reservoir using Geo-Spatial Data (지형공간정보를 이용한 임하호 수변구역 토사유실 분석)

  • Lee, Geun-Sang;Hwang, Eui-Ho;Park, Jin-Hyeog;Chae, Hyo-Sok
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2006.05a
    • /
    • pp.908-912
    • /
    • 2006
  • Geology and terrain of Imha basin has a very weak characteristics to soil erosion, so much soil particles flow into Imha reservoir and bring about high density turbid water when it rains a lot. Especially, since the agricultural area of Imha basin is mainly located in river boundary, Imha reservoir has suffered from turbid water by soil erosion. Therefore, it is important to estimate the influence of soil erosion to establish efficient management of water-pollutant buffering zone for the reduction of turbid water. By applying GIS-based RUSLE model, this study can acquire 12.23% that is the ratio of soil erosion in water-pollutant buffering zone and is higher than area-ratio (9.95%) of water-pollutant buffering zone. This is why the area-ratio of agricultural district (27.24%) in water-pollutant buffering zone is higher than the area-ratio of agricultural district (14.96%) in Imha basin. Also as the result of soil erosion in sub-basin, Daegok basin shows highest soil erosion in water-pollutant buffering zone, second is Banbyeon_10 basin and last is Seosi basin.

  • PDF

Molecular Simulation Study on Influence of Water Film Thickness on Lubrication Characteristics (물 분자막의 두께와 윤활특성의 상관관계에 대한 분자시뮬레이션 연구)

  • Kim, Hyun-Joon;Heo, Segon
    • Tribology and Lubricants
    • /
    • v.38 no.5
    • /
    • pp.199-204
    • /
    • 2022
  • This paper presents a numerical investigation of the influence of water molecule thickness on frictional behavior at the nanoscale using molecular dynamics simulation. Three different models, comprising water thin films of various thicknesses, were built, and indentation and sliding simulations were performed using the models. Various normal loads were applied by indenting the Si tip on the water film for the sliding simulation to evaluate the interplay between the water thin film thickness and the normal load. The results of the simulations showed that the friction force generally increased with respect to the normal load and thickness of the water thin film. The friction coefficient varied with respect to the normal load and the water film thickness. The friction coefficient was the smallest under a moderate normal force and increased with decreasing or increasing normal loads. As the water film became thicker, the contact area between the tip and water film became larger. Under well-lubricated conditions, the friction force was proportional to the contact area regardless of the water film thickness. As the normal force increased above a critical condition, the water molecules beneath the Si tip spread out; thus, the film could not provide lubrication. Consequently, the substrate was permanently deformed by direct contact with the Si tip, while the friction force and friction coefficient significantly increased. The results suggest that a thin water film can effectively reduce friction under relatively low normal load and contact pressure conditions. In addition, the contact area between the contacting surfaces dominates the friction force.

Application of peak load for industrial water treatment plant design (공업용수 정수장 설계시 첨두부하 적용방안)

  • Kim, Jinkeun;Lee, Heenam;Kim, Dooil;Koo, Jayong;Hyun, Inhwan
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.30 no.3
    • /
    • pp.225-231
    • /
    • 2016
  • Peak load rate(i.e., maximum daily flow/average daily flow) has not been considered for industrial water demand planning in Korea to date, while area unit method based on average daily flow has been applied to decide capacity of industrial water treatment plants(WTPs). Designers of industrial WTPs has assumed that peak load would not exist if operation rate of factories in industrial sites were close to 100%. However, peak load rates were calculated as 1.10~2.53 based on daily water flow from 2009 to 2014 for 9 industrial WTPs which have been operated more than 9 years(9-38 years). Furthermore, average operation rates of 9 industrial WTPs was less than 70% which means current area unit method has tendency to overestimate water demand. Therefore, it is not reasonable to consider peak load for the calculation of water demand under current area unit method application to prevent overestimation. However, for the precise future industrial water demand calculation more precise data gathering for average daily flow and consideration of peak load rate are recommended.

논산지역 간이급수시설 수질특성에 대한 연구

  • Go Gyeong-Seok;Lee Jin-Su;Kim Tong-Gwon;Kim Jae-Gon;Jo Seong-Hyeon;Seok Hui-Jun;Kim Hyeong-Su
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2005.04a
    • /
    • pp.344-347
    • /
    • 2005
  • The purpose of the study for the development of the technologies of water quality monitoring and contamination protection at water resource aquifer is to secure the groundwater as potable water resources. The results of water analysis as a basis of potable water criteria showed that 30 groundwater samples among 138 samples of small water supply system (21.7%) were exceeded the water criteria. The concentrations of Cl, $NO_3$ and Na for granite area are higher than those of gneiss and metasedimentary rocks of Ogcheon belt area and they are caused by the high vulnerability of groundwater at granite region where the residential area and cultivated land are concentrated. The spatial distribution of components indicated the close relationships between water quality and geology, land use, and topography. The multivariate statistical results showed that the water samples are divided into three groups by geology.

  • PDF

The Evaluation on the exiting greens of Hwasan Country Club by undisturbed Soil Core Analysis (토양 코아 분석을 통한 화산 골프장의 조성된 그린에 대한 평가)

  • 이상재;허근영;심경구
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.26 no.2
    • /
    • pp.54-61
    • /
    • 1998
  • The subsurface environment of the root zone area can set the stae for "do or die" of the turfgrass plant. The good condition of the greens is verified by their physical properties. Therefore, this study was carried to evaluate on the existing green of Hwasan C.C. by undisturbed soil Core Anaysis. We completed the ISTRC SYSTEM BenchMarking of the undisturbed core samples taken from Green #1, Green #5, Green #9-"Best" area, and Green #9-"Stressed" area for the Hwasan C.C.. It was also our understanding that the greens were in "good" to "very good" conditioni. THe exception might be Green #9-"Stress" area, which was the stressed area. The stressed area was confined to a ridge across Green #9. The organic content test results comfirmed the development of organic layering in depth 0-2.5cm. For the amount of compaction in the upper root zones and te development of the green's respective organic layers, the infiltration rates were high in Green #1, Green #5, and Green #9 "Stressed" area. The depicted aerificaton hole might be the probable cause of the relatively high infiltraton rate. Green #9-"Best" area had a tested infiltration rate of 18.75cm/hr. Either this area had not been aerified, or the undisturbed sample did not contain a aerification cavity. The water retention capacity of the undisturbed samples was good. When the greens were first constructed, the original root zone mix had been relatively low water retention properties. And the bulk density and the porosity of the undisturbed samples were good. In the result, all the greens were similar except for the infiltration. Thus, we supposed that Green #9-"Stressed" area might be ainly influenced by the amount of irrigation water and the configuration of the green's surface. There had been a reduction in the amount of irrigation water as the water retention capacity in the greens was promoted. Especially, it had gradually become more of a problem as the green had matured in Green #9-"Stressed" area. Because Green #9-"Stressed" area was a ridge area. The reduction in the amount of irrigation water might be the probable cause of the stress in Green #9-"Stressed" area. Our final observation related to the soil texture and the particle size distribution of the sand. Though and sand contant of all the tested greens were good, the gravel content of them exceeded ISTRC Guidelines. In particle size distribution of the sand, the very coarse and the coarse content of all the tested greens exceeded, but the rest was insufficient. The stability is a function of the material retained on the 0.25mm mesh screen. But, the content of all the tested greens was very insufficient. Though all the greens was serviceable, the coarse root zone sands, such as the sand in the tested greens, tended to be "unstable". Thus, we recommend using a topdressing/aerification sand which should be more in line with ISTRC/USGA Guidelines.;unstable". Thus, we recommend using a topdressing/aerification sand which should be more in line with ISTRC/USGA Guidelines.ines.

  • PDF

Bacteriological Characteristics of Drinking Water in Pusan Area (부산지역 음용수의 세균학적 특성)

  • 김용관
    • Journal of Environmental Health Sciences
    • /
    • v.19 no.2
    • /
    • pp.34-39
    • /
    • 1993
  • One hundred and eighty-seven water samples were collected from 23 of spring water, 2 of ground water, 1 of tap water in Pusan area and 3 of natural mineral waters. Total coliform group, fecal coliform, viable cell count and microflora were investigated to evaluate water quality of drinking water. The results were as follows: range and geometric mean value of total coliform and fecal coliform MPN's of spring water were 0~1,500/100 ml, 85/100 ml and 0~460/100 ml, 24/100 ml but coliform group was not detected in the samples of tap water and natural mineral water. Viable cell count of spring water, ground water and tap water were lower as 100 cell than the criteria for drinking water but that of natural mineral water was higher as 6.5X 10$^2$~7.4X 10$^3$ /ml. Predominant speces among the 219 strains isolated from the samples were 19.6% Aeromonas spp., 19.2% Enterobacteriaceae, 16% Acinetobacter spp. Especially, spring water and vessels were contaminated by Hafnia spp. and Providencia Spp, inhabitant of the oral cavity.

  • PDF

Nutrient Behavior at Paddy Field Area with Large-Scaled Plots during Irrigation Periods (관개기 대구획 광역논에서의 영양물질 거동)

  • Oh, Seung-Young;Kim, Jin-Soo;Jung, Gu-Young
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2005.05b
    • /
    • pp.1254-1258
    • /
    • 2005
  • Net outflow flux and unit load of pollutants were investigated at a paddy fields area(Soro-ri) with large-scaled plots on loam soil during irrigation seasons of $2001\~2003$. Water samples were collected, and inflow and outflow were .measured at $5\~10$ day intervals during non-storm periods and at $2\~6$ hours intervals during storm events. The average concentration of TP in percolated water was much smaller than that in irrigation and surface outflow water likely due to phosphorus absorption capacity of paddy soils. Net outflow flux in study area was significantly correlated with rainfall and surface outflow discharge. Nutrient flux from Paddy fields can be abated by reduction in outflow surface discharge.

  • PDF

Assessing the Benefits of Water Quality Improvements Using Contingent Valuation Method: Case Study of the Kumgang Area (가상 가치 접근법을 이용한 수질 개선 사업의 편익 측정: 금강 유역 사례)

  • Cho, Hong-Jin;Lee, Byoung-Nam;Kim, Ji-Soo
    • IE interfaces
    • /
    • v.11 no.3
    • /
    • pp.209-218
    • /
    • 1998
  • This paper is concerned with the assessment of benefits from water quality improvements. The contingent valuation method (CVM) is employed to directly measure the value of the project for the improvement of the water pollution in the Kumgang area. The perceived value of the improved water quality is investigated by using questionnaires to those concerned living near water-polluted area. The questionnaire includes such questions as the amount to willingly pay, the motivation to pay, the reasons of rejecting the payment, and some socio-economic data. The results of the survey show that (1) non-use value of the environmental goods is perceived to be more important than use-value of the environmental goods; (2) "willingness to pay" for the improved water quality varies according to the degree of educational level. income level and ages; (3) the resistance to pay for the project comes from the "polluter's pay principle".

  • PDF