• 제목/요약/키워드: Water and wastewater treatment facilities

검색결과 178건 처리시간 0.025초

Water treatment sludge for removal of heavy metals from electroplating wastewater

  • Ghorpade, Anujkumar;Ahammed, M. Mansoor
    • Environmental Engineering Research
    • /
    • 제23권1호
    • /
    • pp.92-98
    • /
    • 2018
  • Suitability of aluminium-based water treatment sludge (WTS), a waste product from water treatment facilities, was assessed for removal of heavy metals from an electroplating wastewater which had high concentrations of copper and chromium along with other heavy metals. Batch tests with simulated wastewater in single- and multi-metal solutions indicated the influence of initial pH and WTS dose on removal of six metals namely Cu(II), Co(II), Cr(VI), Hg(II), Pb(II) and Zn(II). In general, removal of cationic metals such as Pb(II), Cu(II) and Zn(II) increased with increase in pH while that of anionic Cr(VI) showed a reduction with increased pH values. Tests with multi-metal solution showed that the influence of competition was more pronounced at lower WTS dosages. Column test with diluted (100 times) real electroplating wastewater showed complete removal of copper up to 100 bed volumes while chromium removal ranged between 78-92%. Other metals which were present in lower concentrations were also effectively removed. Mass balance for copper and chromium showed that the WTS media had Cu(II) and Cr(VI) sorption capacities of about 1.7 and 3.5 mg/g of dried sludge, respectively. The study thus indicates that WTS has the potential to be used as a filtration/adsorption medium for removal of metals from metal-bearing wastewaters.

Phanerochaete chrysosporium PSBL-1을 이용한 축산폐수와 하수의 연계처리 (Combined Treatment of Livestock Wastewater with Sewage Using Phanerochaete chrysosporium PSBL-1)

  • 이순영;조홍식;원찬희
    • 대한환경공학회지
    • /
    • 제28권3호
    • /
    • pp.286-291
    • /
    • 2006
  • 본 연구에서는 축산폐수와 하수의 연계처리 가능성을 연구하였다 축산폐수와 하수를 2:1로 혼합하고 응집제인 BF02와 응집보조제인 양이온 polymer인 C-210EL를 각각 2 mL, 100 mL씩 주입시 SS 97.6%, T-P 95%로 최적 제거효율을 보였다. Phanerochaete chrysosporium PSBL-1의 처리 특성을 살펴보기 위해서 전처리수를 축산폐수 원수에 대해 10배 희석되도록 하수와 혼합($\fallingdotseq$전처리수:하수=3:17)하였다. 이렇게 혼합된 폐수의 NBDCOD, $NH_3-N$, T-N의 제거율은 pH가 증가할수록 증가하였다. 즉, T-N 농도는 pH 6.7(5일 경과시), pH 8.0(3일 경과시), pH 10.0(1일 경과시)에서 각각 35 mg/L, 51 mg/L, 33 mg/L으로 축산폐수공공처리시설의 방류수허용기준 60 mg/L을 만족하였다. 또한 모든 pH(1일 경과시)에서 $COD_{Mn}$의 방류수허용기준 40 mg/L을 만족했다. V.A.(veratryl alcohol) 첨가시 V.A.를 첨가하지 않은 조건보다 유출수의 유기물 및 질소농도가 높게 측정되었다. $COD_{Mn}$은 C/N비(3:1)를 조절하지 않은 경우 1일 이후, T-N은 C/N비를 $4{\sim}6$으로 조절한 경우 2일 후에 축산폐수공공처리시설 방류수수질기준을 만족하였다.

CFD를 이용한 농축조 슬러지의 유출흐름특성 해석 (Analysis of the sludge thickening characteristics in the thickener using CFD Model)

  • 박노석;문용택;김병군;김홍석
    • 상하수도학회지
    • /
    • 제25권5호
    • /
    • pp.777-782
    • /
    • 2011
  • The residual treatment facilities in WTP(water treatment plant) play an important role in solid-liquid separation. At present, it is difficult to solve problems related with thickening and dewatering of WTP sludge, and discharging waste water to river. The quantity of residuals generated from water treatment plants depends upon the raw water quality, dosage of chemicals used, performance of the treatment process, method of sludge removal, efficiency of sedimentation, and backwashing frequency. Sludge production by the physical separation of SS(Suspended Solid) occurs under quiescent conditions in the primary clarifier, where SSs are allowed to settle and to consolidate on the clarifier bottom. Raw primary sludge results when the settled solids are hydraulically removed from the tank. In this study, Drawing characteristics of the sludge thickening in the thickener of Water Treatment Plants was simulated by Using CFD(Computational Fluid Dynamics.

하수처리시설의 Retrofitting을 위한 파일럿 규모 공기부상공정 연구 (A Pilot Study on Air Flotation Processes for Retrofitting of Conventional Wastewater Treatment Facilities)

  • 박찬혁;홍석원;이상협;최용수
    • 상하수도학회지
    • /
    • 제22권3호
    • /
    • pp.329-336
    • /
    • 2008
  • The pilot study was conducted to evaluate the applicability of air flotation(AF) processes combined with biological nutrient removal(BNR) for the retrofitting of conventional wastewater treatment facilities. The BNR system was operated in pre-denitrification and intermittent aeration; developed ceramic membrane diffusers were installed to separate the solid-liquid of activated sludge at the bottom of a flotation tank. Before performing a pilot scale study, the size distribution of microbubbles generated by silica or alumina-based ceramic membrane diffusers was tested to identify the ability of solid-liquid separation. According to the experimental results, the separation and thickening efficiency of the alumina-based ceramic membrane diffuser was higher than the silica-based ceramic membrane diffuser. In a $100m^3/d$ pilot plant, thickened and return sludge concentration was measured to be higher than 15,000mg SS/L, therefore, the MLSS in the bioreactor was maintained at over 3,000mg SS/L. The effluent quality of the AF-BNR process was 4.2mg/L, 3.7mg/L, 10.6mg/L and 1.6mg/L for $BOD_5$, SS, T-N and T-P, respectively. Lastly, it was revealed that the unit treatment cost by flotation process is lower than about $1won/m^3$ compared to a gravity sedimentation process.

물수요의 추세 변화의 적응을 위한 모델링 절차 제시:베이지안 매개변수 산정법 적용 (Modeling Procedure to Adapt to Change of Trend of Water Demand: Application of Bayesian Parameter Estimation)

  • 이상은;박희경
    • 상하수도학회지
    • /
    • 제23권2호
    • /
    • pp.241-249
    • /
    • 2009
  • It is well known that the trend of water demand in large-size water supply systems has been suddenly changed, and many expansions of water supply facilities become unnecessary. To be cost-effective, thus, politicians as well as many professionals lay stress on the adaptive management of water supply facilities. Failure in adapting to the new trend of demand is sure to be the most critical reason of unnecessary expansions. Hence, we try to develop the model and modeling procedure that do not depend on the old data of demand, and provide engineers with the fast learning process. To forecast water demand of Seoul, the Bayesian parameter estimation was applied, which is a representative method for statistical pattern recognition. It results that we can get a useful time-series model after observing water demand during 6 years, although trend of water demand were suddenly changed.

하수처리시설에서 인 고도처리를 위한 일체형 침전부상공정(SeDAF)의 응집제 주입농도 자동제어기법 검토 (Automatic control of coagulant dosage on the sedimentation and dissolved air flotation(SeDAF) process for enhanced phosphorus removal in sewage treatment facilities)

  • 장여주;정진홍;김원재
    • 상하수도학회지
    • /
    • 제34권6호
    • /
    • pp.411-423
    • /
    • 2020
  • To remove phosphorus from the effluent of public wastewater treatment facilities, hundreds of enhanced phosphorus treatment processes have been introduced nationwide. However, these processes have a few problems including excessive maintenance cost and sludge production caused by inappropriate coagulant injection. Therefore, the optimal decision of coagulant dosage and automatic control of coagulant injection are essential. To overcome the drawbacks of conventional phosphorus removal processes, the integrated sedimentation and dissolved air flotation(SeDAF) process has been developed and a demonstration plant(capacity: 100 ㎥/d) has also been installed. In this study, various jar-tests(sedimentation and / or sedimentation·flotation) and multiple regression analyses have been performed. Particularly, we have highlighted the decision-making algorithms of optimal coagulant dosage to improve the applicability of the SeDAF process. As a result, the sedimentation jar-test could be a simple and reliable method for the decision of appropriate coagulant dosage in field condition of the SeDAF process. And, we have found that the SeDAF process can save 30 - 40% of coagulant dosage compared with conventional sedimentation processes to achieve total phosphorus (T-P) concentration below 0.2 mg/L of treated water, and it can also reduce same portion of sludge production.

포기조의 낮은 용존산소로 인한 제지폐수의 슬러지 팽화특성 (Characteristics of Sludge Bulking Caused by Low Dissolved Oxygen in Aeration Tank for Paper Mill Wastewater Treatment)

  • 곽동희;유승준;박종천
    • 한국물환경학회지
    • /
    • 제24권4호
    • /
    • pp.458-464
    • /
    • 2008
  • Bulking phenomena and scum formation are common problem in suspended growth system like the activated sludge plants for wastewater treatment. Apart from wastewater composition, operating conditions, such as mechanical stress by insufficient oxygen supply, are often decisive for the occurrence of a bulking or scumming problem. There were the comparative aeration tanks in terms of sludge bulking caused by the difference of mechanical aeration facilities in the wastewater treatment plant of N paper mill company. In this study the cause of bulking was investigated through not only the biological isolation and identification but also a series of operational data consideration. On the basis of the investigation results for bulking cause, the operational criteria on dissolved oxygen concentration was derived to decrease the bulking problem.

Impact of Pig Slurry from WangGoong Farm Cluster on Water Quality of the Iksan Stream

  • Choi, Hong-Lim;Suresh, A.;Babu, T.;Mansyur, Mansyur
    • Journal of Animal Science and Technology
    • /
    • 제53권6호
    • /
    • pp.549-561
    • /
    • 2011
  • Livestock wastewater is being discharged without treatment from Hasen's pig farm cluster in WangGoong (WG) area into the Iksan Stream, eventually flowing into the ManGyung (MG) at the upstream junction. Although it is well known that before discharge, wastewater must satisfy the pig slurry discharge standards; because of ongoing remodeling, proper treatment is not being performed. According to public records, wastewater from the WG pig farm cluster is responsible for 3.6% of MG River pollution and 2.0% of the SaeManGuem (SMG) Reservoir pollution. As a result, upstream water treatment quality has become primary concern for development of the SMG project. All physicochemical constituents and pathogenic microbes, such as chemical oxygen demand ($COD_{Cr}$), biochemical oxygen demand ($BOD_5$), total suspended solids (TSS), total nitrogen (TN), total phosphorous (TP), fecal coliforms, Escherichia coli and Salmonella at the effluent of WG Plant (S-1) exceed the effluent standards. This is mainly due to insufficient wastewater treatment: the WG Plant is under renovation to increase water purification efficiency. By comparing the water quality at the S-7 junction, where the the Iksan Stream (pig farms) and the Wanggoong Stream (no pig farms) merge, it is clear that farming facilities and improper treatment can critically affect surrounding water quality. While it is clear throughout this study that the level of all physicochemical parameters and pathogenic microbes along the Stream decreased due to sedimentation, biodegradation and/or dilution. An alarming problem was discovered: the existence of pathogenic microbe count(E coli, Salmonella) in the lagoon wastewater and the stream water. Not only were high concentrations of these pathogens themselves found, but the potential existence of more serious pathogens could rise to more dangerous conditions.

상수처리에서 염소 및 오존산화를 이용한 색도제거 (Chromaticity removal by chlorine and ozone oxidation in water treatment)

  • 이정훈;김진근
    • 상하수도학회지
    • /
    • 제31권4호
    • /
    • pp.273-279
    • /
    • 2017
  • Optimal processes to remove chromaticity at E water treatment plant(WTP) mainly caused by algae of E lake in Jeju island were investigated based on lab-tests of chlorine and ozone oxidation. 42.9% of chromaticity of filtered water was removed by chlorine oxidation under pH 7.0~8.0, dose of 1.0 mg/L with contact time of 30~60 min. On the other hand, chromaticity removal was 71.4% when post-ozone dose of 0.9~1.9 mg/L and pH 9.0, while it was increased to 86.7% under post-ozone dose of 3.1~7.3 mg/L and pH 9.0. However, there was no significant chromaticity removal efficiency increase when ozone doses were higher than 5.0 mg/L regardless of feeding point(i.e., pre-ozonation and post-ozonation) and pHs(i.e., 7.0 and 9.0.) under the experimental conditions. Based on the results, chlorine oxidation using existing chlorination facilities at the WTP is recommended for lower chromaticity while ozone oxidation is recommended for higher chromaticity by installing new ozone feeding facilities.