Study on characteristics of specific hazardous substances in the industrial wastewater effluent (사업장 방류수 중 특정수질유해물질 배출 특성 연구)

  • Kim, Seungho;Choi, Youngseop;Kim, Yunhee;Kim, Jongmin;Chang, Gilsik;Bae, Seokjin;Cho, Younggwan
    • Analytical Science and Technology
    • /
    • v.29 no.3
    • /
    • pp.114-125
    • /
    • 2016
  • In this study, 165 wastewater discharge facilities in 10 business types were investigated with regard to 24 specific hazardous substances that included heavy metals, VOCs, CN, and phenol in the Gwangju city. Cu in the range from from 0.008 to 35.420 mg/L was detected in all business types and the detection rate was 46.8 %. Other heavy metals, such as Cd, As, Hg, Pb, and Cr+6 were detected as well. However, their detection rates ranged between 0.6 and 1.8 %. CN and phenol were detected in one and five facilities, respectively. 12 species of VOCs were detected: chloroform 80.6 % (0.42 to 81.60 μg/L), benzene 16.4 % (1.49 to 3.31 μg/L), trichloroethylene 11.5 % (1.78 to 6.02 μg/L), 1,1-dichloroethylene 10.3 % (1.23 to 5.89 μg/L), and dichloromethane 8.5 % (0.28 to 968.86 μg/L) in the detection rate order. The concentration of VOCs was detected in trace amounts, except for dichloromethane that exceeded the effluent quality standard in three business types, namely, metal manufacturing, food industry, and car washing facility. Chloroform was detected in all business types, where 24.88 μg/L were detected in the laundry business and 53.41 μg/L in the water supply business; the mean concentration of chloroform in these two business types was higher than elsewhere. Therefore, for the disposal of non-degradable specific hazardous substances in industrial wastewater, it is necessary to introduce physical and chemical processes, such as activated carbon adsorption, fenton oxidation, ozone treatment, as well as photocatalyst and the UV radiation.

Environmental Capacity Assessment of Busan City (부산시 환경용량평가에 관한 연구)

  • Hwang, Kyung-Yup;Hwang, Inseong;Lee, Soon-Kyu;Jo, Seung-Wu;Oh, Kwang-Joong
    • Journal of Environmental Impact Assessment
    • /
    • v.15 no.1
    • /
    • pp.79-92
    • /
    • 2006
  • Environmental capacity assessment of Busan city was conducted to provide basis for planning on sustainable development and growth of the city. Using Onish model, assessment was carried out on amenities and service facilities for the citizens of Busan city. Ecological Footprint model was used to judge if the city exceeds the its environmental capacity and to estimate the extent of the excess if it exists. The analysis using Onish model revealed that the citizens of Busan city are generally well supported by the infrastructure and service facilities of the city. Water treatment and supply facilities have enough capabilities to support the city, whereas the relatively low rate of sanitary sewer supply (78%) suggests the need for further improvement in the wastewater area. The capacities of sanitary landfills are found sufficient enough to support the city for the next 10 years. The high value for the line length served per capita in the subway sector hints on certain inconvenience of commuters. All the air quality indicators meet the Korean and WHO standards except for $NO_2$. The ecological footprint model analysis produced EF indicators for Busan city of 3.04 ha/person and 2.54 ha/person for the years of 1993 and 2003, respectively. The decrease of the indicator from 1993 to 2003 is mainly due to the incorporation of Gijang area by Busan city in 1995, suggesting the importance of the ecologically productive area in the evaluation using this model. The analysis on the ecological deficit that is based on ecologically productive land shows that the consumption by Busan city exceeds its ecologically available production by 19,600% as of 2003. The area needed to support the consumption of Busan city in 2003 is 123 times as large as the present area of Busan city, which is substantially lower than the multiplier (742) obtained for Seoul city in 1997 but is higher than those observed for Chongju city (71 in 1999) and Ulsan city (39 in 2001).

Supercritical CO2 Dyeing and Finishing Technology - A Review (초임계 이산화탄소 염색 및 가공 기술)

  • Lee, Gyoyoung;Chae, Juwon;Lee, Sang Oh;Kim, Sam Soo;Lee, Jaewoong
    • Textile Coloration and Finishing
    • /
    • v.31 no.1
    • /
    • pp.48-64
    • /
    • 2019
  • With evolution in the production environment of the textile industry, the need for non-water-based dyeing technologies and eco-friendly process facilities in the dyeing and processing stages has increased. In recent years, supercritical fluid dyes have been developed and commercialized in Europe, centering on this demand. However, so far, such dyes have been mainly applied in the processing of PET fibers. Basic research has mainly involved investigation of dyeing by supercritical carbon dioxide or solubility of such dyes, and more in-depth research should be continuously carried out. In this review, we describe the types and characteristics of supercritical fluids that exhibit specific properties at pressures and temperatures over the critical point. In addition, the state of the art in the dyeing and processing technology using supercritical fluids and associated, processing problems, environmental regulation, and wastewater treatment issues are described in detail. We hope this review can contribute to the supercritical fluid technology being further developed as an environment friendly dyeing processing method. Furthermore, we expect that the technique can be used as a means of ensuring different, high-quality dyed products.

Acoustic Interface Element on Nonconformal Finite Element Mesh for Fluid-Structure Interaction Problem (비적합 유한요소망에 적용가능한 유체-구조물 연결 요소)

  • Cho, Jeong-Rae;Lee, Jin Ho;Cho, Keunhee;Yoon, Hyejin
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.27 no.4
    • /
    • pp.163-170
    • /
    • 2023
  • In the fluid-structure interaction analysis, the finite element formulation is performed for the wave equation for dynamic fluid pressure, and the dynamic pressure is defined as a degree of freedom at the fluid nodes. Therefore, to connect the fluid to the structure, it is necessary to connect the degree of freedom of fluid dynamic pressure and the degree of freedom of structure displacement through an interface element derived from the relationship between dynamic pressure and displacement. The previously proposed fluid-structure interface elements use conformal finite element meshes in which the fluid and structure match. However, it is challenging to construct conformal meshes when complex models, such as water purification plants and wastewater treatment facilities, are models. Therefore, to increase modeling convenience, a method is required to model the fluid and structure domains by independent finite element meshes and then connect them. In this study, two fluid-structure interface elements, one based on constraints and the other based on the integration of nonsmooth functions, are proposed in nonconformal finite element meshes for structures and fluids, and their accuracy is verified.

Operating Status and Improvement Plans of Ten Wetlands Constructed in Dam Reservoirs in Korea (국내 10개 댐저수지 인공습지의 운영현황 및 개선방안)

  • Choi, Kwangsoon;Kim, Sea Won;Kim, Dong Sup;Lee, Yosang
    • Journal of Wetlands Research
    • /
    • v.16 no.3
    • /
    • pp.431-440
    • /
    • 2014
  • To propose the improvement and management plans to strengthen the pollutant removal efficiency of dam reservoir's constructed wetlands(CWs), the operation status and configuration of CWs (including water depth, operational flow, water flow distribution, residence time, and pollutant removal efficiency, aspect ratio, open water/vegetation ratio etc.) were analyzed in 10 major wetlands constructed in dam reservoirs. The pollutant concentrations in the inflows of the studied CWs were lower than those of American and European constructed wetlands. Especially, organic matter concentrations in all of inflows were below 3 mg/L(as BOD) due to advanced treatment of sewage disposal plant and an intake of low concentration water during dry and normal seasons. The average removal efficiency of total nitrogen(TN) and total phosphorus(TP) for 10 CWs ranged from 7.6~67.6%(mean 24.9%) and -4.9~74.5%(mean 23.7%), respectively, showing high in wetlands treating municipal wastewater. On the other hand, the removal efficiency of BOD was generally low or negative with ranging from -133.3 to 41.7%. From the analysis of the operation status and configuration of CWs, it is suggested that the low removal efficiency of dam reservoir's CWs were caused by both structural (inappropriate aspect ratio, excessive open water area) and operational (neglecting water-level management, lack of facilities and operation for first flush treatment, lake of monitoring during rainy events) problems. Therefore, to enable to play a role as a reduction facility of non-point source(NPS) pollutants, an appropriate design and operation manuals for dam reservoir's CW is urgently needed. In addition, the monitoring during rainy events, when NPS runoff occur, must be included in operation manual of CW, and then the data obtained from the monitoring is considered in estimation of the pollutant removal efficiency by dam reservoir's CW.

Feasibility Study on Double Path Capacitive Deionization Process for Advanced Wastewater Treatment (이단유로 축전식 탈염공정의 하수고도처리 적용가능성 평가)

  • Cha, Jaehwan;Shin, Kyung-Sook;Lee, Jung-Chul;Park, Seung-Kook;Park, Nam-Su;Song, Eui-Yeol
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.36 no.4
    • /
    • pp.295-302
    • /
    • 2014
  • This study demonstrates a double-path CDI as an alternative of advanced wastewater treatment process. While the CDI typically consists of many pairs of electrodes connected in parallel, the new double-path CDI is designed to have series flow path by dividing the module into two stages. The CFD model showed that the double-path had uniform flow distribution with higher velocity and less dead zone compared with the single-path. However, the double-path was predicted to have higher pressure drop(0.7 bar) compared the single-path (0.4 bar). From the unit cell test, the highest TDS removal efficiencies of single- and double-path were up to 88% and 91%, respectively. The rate of increase in pressure drop with an increase of flow rate was higher in double-path than single-path. At 70 mL/min of flow rate, the pressure drop of double-path was 1.67 bar, which was two times higher than single-path. When the electrode spacing was increased from 100 to $200{\mu}m$, the pressure drop of double-path decreased from 1.67 to 0.87 bar, while there was little difference in TDS removal. When proto type double-path CDI was operated using sewage water, TDS, $NH_4{^+}$-N, $NO_3{^-}$-N and $PO_4{^{3-}}$-P removal efficiencies were up to 78%, 50%, 93% and 50%, respectively.

Development of A Material Flow Model for Predicting Nano-TiO2 Particles Removal Efficiency in a WWTP (하수처리장 내 나노 TiO2 입자 제거효율 예측을 위한 물질흐름모델 개발)

  • Ban, Min Jeong;Lee, Dong Hoon;Shin, Sangwook;Lee, Byung-Tae;Hwang, Yu Sik;Kim, Keugtae;Kang, Joo-Hyon
    • Journal of Wetlands Research
    • /
    • v.24 no.4
    • /
    • pp.345-353
    • /
    • 2022
  • A wastewater treatment plant (WWTP) is a major gateway for the engineered nano-particles (ENPs) entering the water bodies. However existing studies have reported that many WWTPs exceed the No Observed Effective Concentration (NOEC) for ENPs in the effluent and thus they need to be designed or operated to more effectively control ENPs. Understanding and predicting ENPs behaviors in the unit and \the whole process of a WWTP should be the key first step to develop strategies for controlling ENPs using a WWTP. This study aims to provide a modeling tool for predicting behaviors and removal efficiencies of ENPs in a WWTP associated with process characteristics and major operating conditions. In the developed model, four unit processes for water treatment (primary clarifier, bioreactor, secondary clarifier, and tertiary treatment unit) were considered. Additionally the model simulates the sludge treatment system as a single process that integrates multiple unit processes including thickeners, digesters, and dewatering units. The simulated ENP was nano-sized TiO2, (nano-TiO2) assuming that its behavior in a WWTP is dominated by the attachment with suspendid solids (SS), while dissolution and transformation are insignificant. The attachment mechanism of nano-TiO2 to SS was incorporated into the model equations using the apparent solid-liquid partition coefficient (Kd) under the equilibrium assumption between solid and liquid phase, and a steady state condition of nano-TiO2 was assumed. Furthermore, an MS Excel-based user interface was developed to provide user-friendly environment for the nano-TiO2 removal efficiency calculations. Using the developed model, a preliminary simulation was conducted to examine how the solid retention time (SRT), a major operating variable affects the removal efficiency of nano-TiO2 particles in a WWTP.

Investigation on Economical Feasibility for Energy Business of Waste Water Sludge Discharged in 'A' Industrial Complex (A-산업단지 발생 슬러지의 에너지화를 위한 경제성 검토)

  • Byun, Jung-Joo;Lee, Kang-Soo;Phae, Chae-Gun
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.20 no.4
    • /
    • pp.61-74
    • /
    • 2012
  • Industrial complexes in Korea have been vigorously established by economic development plan and development policy of industry in 1960s. Recently, Korean government has promoted Eco Industrial Park (EIP) project to recycle by-products and wastes in industrial park In this study, we analyzed the physical and chemical properties for the sludges discharged from A industrial complex. And we investigated the economic feasibility and environmental impact of sludge to energy facilities. The analysis results indicated that the petrochemical industry were 92% in sludge production, the highest treatment amount was landfill, followed by incineration and recycling and then ocean disposal. Wastewater sludge and process sludge samples are collected and analyzed to use as basic data on economic feasibility and environmental impact. Weighted average heating value of sludge samples was 3,891kcal/kg. Based on this data, installation and operation costs, operation returns of operating the drying facility are estimated, compared with cogeneration facility. And this study examines how the payback period of each simulation(total 8 case) with the important parameter changes. As a result, it was found that what needs the shortest payback period is 3years with connection of drying facility and cogeneration facility based on the government's financial subsidy system.