• Title/Summary/Keyword: Water and sewage

Search Result 1,264, Processing Time 0.025 seconds

Prediction of water quality in Tan stream of the Han river (장래 탄천수질과 한강본류에 미치는 영향 예측)

  • 신정식;정종흡;오경두;나규환
    • Journal of Environmental Health Sciences
    • /
    • v.27 no.3
    • /
    • pp.49-56
    • /
    • 2001
  • The water quality simulation was carried out to predict water quality in Tan stream of the Han river using water quality model, QUAL2E. In the end, the future variations in water quality of Tan stream were simulated and the prediction of the impacts of Tan stream on water quality in the Han river was carried out by applying the Tan stream simulation results into the model. The results are as follows. The predicted results of future water quality of Tan stream suggested that the concentrations of BOD, T-N and T-P at Chungdam bridge would increase to 0.68~0.77 mg/$\ell$, 1.33~1.62 mg/$\ell$ and 0.05~0.06 mg/$\ell$, respectively in 2006 and 2011 and that with the implementation of advanced treatment in Sungnam and Tanchun sewage treatment plants, the concentration of T-N would be reduced more as the amount of treated sewage increase, while the concentration of T-P would stay 0.49 mg/$\ell$. The results obtained from simulation of the impacts of future Tan stream water quality improvement on the main stream of the Han river showed that with implementation of advanced treatment in both Sungnam and Tanchun sewage treatment plants, the concentration of T-N, T-P and chlorophyll-a at Hangang bridge and Heangju bridge would be reduced by 11.6%, 7.7% and 20.9%, respectively in 2..6 and by 13.6%, 9.4% and 22.2%, respectively in 2011, which indicates that the effect on the reduction of T-N and T-P would be relatively significant while the effect on the decrease of algae would be slight.

  • PDF

A Study on the Modification Method of Flow Data in the Sewage System (하수관거 유량자료의 보정방법에 관한 연구)

  • Kim, Dae-Geun;Gong, Min-Geun
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.17 no.4
    • /
    • pp.495-502
    • /
    • 2003
  • In order to modify incorrect flow data in the sewage system, the method using the stage-discharge relation and hydraulic characteristic curve of sewer pipe are applied. The modified data were verified with field measured data and the infiltration analysis using the modified data was carried out. When flowrate were measured using the flow-meter in fair weather, the stage data were comparatively consistent but velocity data were very poor for the most part. Therefore, it was recommended that sewage flowrate variation characteristic curve and infiltration were computed using the modified data on the basis of stage data. Especially, in the case of using the hydraulic characteristic curve, extrapolation results of the rainy season flowrate using regression curve on the basis of the data in fair weather were also reasonable.

Analysis of the cost effectiveness according to T-P standard enforcement of public sewage treatment facilities (공공하수처리시설의 총인기준 강화에 따른 비용효과분석)

  • Jeong, Won-Gu;Rim, Jay-Myung
    • Journal of Industrial Technology
    • /
    • v.31 no.A
    • /
    • pp.135-145
    • /
    • 2011
  • This study was conducted to analyze the cost effectiveness in line with total phosphorus standard enforcement of public sewage treatment facilities. The additional cost for the total phosphorus removal process was calculated to analyze the cost effectiveness of the advanced water purification process. The analysis results showed that the T-P removal by coagulation sedimentation was more efficient than the advanced water purification facilities in terms of facilities investment cost, and if the coagulation filteration was used for T-P removal, the activated carbon process among the advanced water purification techniques was more efficient in terms of facilities investment cost. In this study, the effects of the T-P removal process that will be additionally introduced according to the tightening of the effluent T-P standard were analyzed within a limit. The actual benefits of improved T-P concentration in the water source will provide diverse values, including the leisure water, environment improvement water, eco-system in the water source and industrial water, in addition to the advanced water purification.

  • PDF

A Study on the Characteristics of Small-scale Sewage Treatment Plants in Mountain Area and Operation Plan for Winter Season (산악지역 소규모하수처리시설의 특성 및 동절기 운영방안에 관한 연구)

  • Chae, Heejun;Lee, Jiwon;Gil, Kyungik
    • Journal of Wetlands Research
    • /
    • v.23 no.2
    • /
    • pp.183-188
    • /
    • 2021
  • In the case of small-scale sewage treatment plants, it is reported that the amount of inflow fluctuates and it is difficult to operate the sewage treatment due to the inflow of unknown water due to the aging of sewage pipes. In particular, there are many overall operational problems due to the decrease in water temperature in winter. In this study, the operation status of small-scale sewage treatment facilities located in mountainous areas and water quality changes according to temperature were analyzed. It was found that the concentration of BOD, COD, and SS in effluent water was greatly changed depending on the temperature, and it was found that COD was particularly affected. Accordingly, the water level of the bioreactor was raised by 0.4m in order to temporarily apply measures to lower the water temperature in winter. As a result of comparing and analyzing the results when the bioreactor was covered and operated, a significant improvement effect occurred. In addition, a plan to improve the treatment efficiency of the bioreactor in winter is to extend the residence time of the bioreactor, a plan to expand the bioreactor specification, a new flow control tank and transport it to the outside, and an oxygen-free air diffuser to be used as an aerobic tank in case of an emergency in winter. The improvement plan was suggested. The results of this study are expected to be used as basic data for the operation plan of small-scale sewage treatment facilities in winter.

The Effect of Reject Water on the Water Quality of Effluent from S Sewage Treatment Plant (S 하수처리장 반류수가 방류수 수질에 미치는 영향)

  • Kim, Mi-Ran;Kim, Kyoung-Hee;Park, Hae-Sik;Kang, Dong-Hyo;Lee, Jea-Keun
    • Journal of Environmental Science International
    • /
    • v.19 no.3
    • /
    • pp.323-329
    • /
    • 2010
  • To acquire preliminary data for the control of total nitrogen (TN) in S sewage treatment plant, which processes merging food waste and sewage, the effect of reject water on the total nitrogen in the effluent was examined in this study. Water quality data for the plant during the winter period were applied to calculate the mass balance. It was calculated that at least more than 231 kg/d TN should be removed to control the TN concentration in the effluent. Assuming 18 ppm as the goal TN concentration in the effluent, about 941 kg/d TN should be removed from this plant. Approximately 10% more TN should be removed than at present to achieve this result. It was observed that dewatering the filtrate had a considerably greater effect on the total nitrogen in the effluent than the reject waters. The dewatered filtrate contained 1,399kg/d TN. The contribution of the dewatered filtrate to the TN concentration in the effluent was 0.183, which was 7 to 23 times greater than the other reject waters. In addition, the amount of total nitrogen from the reject water, with the exception of the dewatering filtrate, was lower than the amount of TN that should be removed from S sewage treatment plant. Therefore, it was concluded that one of the most effective methods for controlling the TN concentration in effluent was the removal of the TN contained in the dewatering filtrate.

Analysis of Water Quality caused by Improvement of Sewage Treatment Plant in Masan Bay (하수처리장 개선이 마산만 수질에 미치는 영향분석)

  • Oh Hyun-Taik;Goo Jun-Ho;Park Sung-Eun;Choi Yun-Sun;Jung Rae-Hong;Choi Woo-Jeung;Lee Won-Chan;Park Jong-Soo
    • Journal of Environmental Science International
    • /
    • v.14 no.8
    • /
    • pp.777-783
    • /
    • 2005
  • For the sustainable management of marine ecosystem in Masan Bay, we have to assess the carrying capacity and standard of target water quality. In this research, we assume that all pollutants loads are treated in Dukdong sewage treatment plant, then we simulate the physical-biological model for prediction water quality for the achievement of standard water quality. In 2001 year, for the achievement of COD 2.5 mg/L, we need to reduce COD $90\%$, nitrogen $30\%$, phosphate $90\%$ than that of the present value, According to these results, the water quality of sewage treatment plant is required to treat COD 13.5 mg/L, nitrogen 33.3 mg/L, phosphate 6,0 mg/L. If the sewage treatment plant will be expanded much larger in 2011, it will need to be treated in COD 6.6 mg/L, nitrogen 2.5 mg/L, phosphate 5 mg/L for the achievement of water quality standard in COD 2.5 mg/L.

Manufacturing Water Permeable Block Using Loess, Clay and Waste Sewage Sludge (황토, 점토 및 하수처리오니를 이용한 투수블록 제조)

  • Kim, Jong Dae;Han, Sang Moo;Jeong, Byung Gon
    • Journal of Korean Society on Water Environment
    • /
    • v.31 no.5
    • /
    • pp.476-481
    • /
    • 2015
  • Water permeable block was manufactured using waste sewage sludge, loess and clay for the purpose of recycling waste sludge due to the prohibition of waste sludge ocean dumping. Experiments for determining optimum mixing ratio was conducted by changing sludge content in water permeable block as 5~20%. In respect of compressive strength, $1,600N/cm^2$ ($163.3kg/cm^2$) was obtained when the mixing ratio of sludge : loess : clay were maintained by 5% : 65% : 30%, 10% : 65% : 25% and 15% : 65% : 20%, respectively. These mean that relatively high compressive strength can be obtained when the sludge content is maintained 5, 10, 15% at the 65% of loess content. In terms of water permeability and absorption rate, the higher values can be obtained as the sludge content increases. The optimum mixing ratio of sludge : loess : clay came out to be 15% : 65% : 20% when water permeability, absorption and strength were considered altogether, which matches the result observed by an electron microscope. The heavy metal leaching test result of the prepared permeable block appeared to satisfy the environmental standard in the content of Cd, Cu, Pb and As.

A Case Study on Optimization of the Sewage Treatment Plant (사례분석을 통한 하수처리장의 최적화에 관한 연구)

  • No, Yeong-Dae;U, In-Seong;Kim, Da-Yeong;Kim, Seong-Tae;Lee, Seon-Hui
    • Proceedings of the Safety Management and Science Conference
    • /
    • 2012.11a
    • /
    • pp.121-131
    • /
    • 2012
  • This study is an analysis about BOD, COD, SS, T-N, T-P of 4Stage-BNR, MLE + CS(Coagulating Sedimentation), Bio-SAC BNR method of construction for 3 largest sewage treatment plants among 12 sewage treatment plants in Incheon. The purpose of this study is improving the operational effectiveness for Incheon sewage treatment plant by introducing the optimized method for quality of the discharged water.

  • PDF

Effects of Pre-aeration on the Anaerobic Digestion of Sewage Sludge

  • Ahn, Young-Mi;Wi, Jun;Park, Jin-Kyu;Higuchi, Sotaro;Lee, Nam-Hoon
    • Environmental Engineering Research
    • /
    • v.19 no.1
    • /
    • pp.59-66
    • /
    • 2014
  • The aim of this study was to assess the effect of pre-aeration on sludge solubilization and the behaviors of nitrogen, dissolved sulfide, sulfate, and siloxane. The results of this study showed that soluble chemical oxygen demand in sewage sludge could be increased through pre-aeration. The pre-aeration process resulted in a higher methane yield compared to the anaerobic condition (blank). The pre-aeration of sewage sludge, therefore, was shown to be an effective method for enhancing the digestibility of the sewage sludge. In addition, this result confirms that the pre-aeration of sewage sludge prior to its anaerobic digestion accelerates the growth of methanogenic bacteria. Removal rates for $NH_3$-N and T-N increased simultaneously during pre-aeration, indicating simultaneous nitrification and denitrification. The siloxane concentration in sewage sludge decreased by 40% after 96 hr of pre-aeration; in contrast, the sulfide concentration in sewage sludge did not change. Therefore, pre-aeration can be employed as an efficient treatment option to achieve higher methane yield and lower siloxane concentration in sewage sludge. In addition, reduction of nitrogen loading by pre-aeration can reduce operating costs to achieve better effluent water quality in wastewater treatment plant and benefit the anaerobic process by minimizing the toxic effect of ammonia.

Yeast Microflora of Some Aquatic Habitats in El-Minia Governorate, Egypt

  • Haridy, Mamdouh S.A.
    • The Korean Journal of Mycology
    • /
    • v.21 no.2
    • /
    • pp.127-132
    • /
    • 1993
  • 269 yeast strains were isolated from water samples collected from different sites in Minia governorate. These included 126 strains from fresh water, 108 strains from sewage and 35 strains from wastewater from sugar-cane factory. On the basis of 23 different physiological and morphological merkmals, the isolated strains were assigned to 16 species belonging to 11 genera. Total yeast cell counts as well as spectra of yeast species were highly variable in tested water. Total yeast cell counts ranged between $3.0{\times}10^3/l\;and\;1.8{\times}10^6/l$ for fresh water, $3.0{\times}10^4/l\;and\;3.0{\times}10^7/l$ for sewage and $1.5{\times}10^6/l\;and\;2.6{\times}10^7/l$ for wastewater from sugarcane factory. Debaryomyces hansenii, Rhodotorula mucilaginosa and Torulaspora delbrueckii were the dominant species in fresh water, whereas Debaryomyces hansenii, Thrichosporon beigelii, Rhodoforula mucilaginosa and Kluyveromyces marxianus were the dominant species in sewage and Saccharomyces cerevisiae, Kluyveromyces marxianus and Trichosporon beigelii were the dominant species in wastewater from sugar-cane factory. Yeast human pathogens, Trichosporon beigelii, Rhodotorula mucilaginosa and Candida albicans were encountered in water samples indicating that water in El-Minia governorate is also polluted by some pathogenic yeasts.

  • PDF